The aim of this study was to give estimates of the incidence of component incompatibility in hip and knee arthroplasty and to test the effect of an online, real-time compatibility check. Intraoperative barcode registration of arthroplasty implants was introduced in Denmark in 2013. We developed a compatibility database and, from May 2017, real-time compatibility checking was implemented and became part of the registration. We defined four classes of component incompatibility: A-I, A-II, B-I, and B-II, depending on an assessment of the level of risk to the patient (A/B), and on whether incompatibility was knowingly accepted (I/II).Aims
Materials and Methods
Radiographs of 100 randomly chosen femoral neck fractures were assessed by eight observers using Garden's classification. The radiographs were classified identically by all eight in only 22 cases. Another 45 cases were classified by some observers as undisplaced fractures (Stages 1 and 2) and by others as displaced fractures (Stages 3 and 4). Between the different observers the number of displaced fractures varied from 63 to 89. These results show that observers had a relatively poor ability to delineate the various stages of Garden's classification.