The Oswestry-Bristol Classification (OBC) is an MRI-specific assessment tool to grade trochlear dysplasia. The aim of this study is to validate clinically the OBC by demonstrating its use in selecting treatments that are safe and effective. The OBC and the patellotrochlear index were used as part of the Oswestry Patellotrochlear Algorithm (OPTA) to guide the surgical treatment of patients with patellar instability. Patients were assigned to one of four treatment groups: medial patellofemoral ligament reconstruction (MPFLr); MPFLr + tibial tubercle distalization (TTD); trochleoplasty; or trochleoplasty + TTD. A prospective analysis of a longitudinal patellofemoral database was performed. Between 2012 and 2018, 202 patients (233 knees) with a mean age of 24.2 years (SD 8.1), with recurrent patellar instability were treated by two fellowship-trained consultant sports/knee surgeons at The Robert Jones and Agnes Hunt Orthopaedic Hospital. Clinical efficacy of each treatment group was assessed by Kujala, International Knee Documentation Committee (IKDC), and EuroQol five-dimension questionnaire (EQ-5D) scores at baseline, and up to 60 months postoperatively. Their safety was assessed by complication rate and requirement for further surgery. The pattern of clinical outcome over time was analyzed using mixed regression modelling.Aims
Methods
We have previously demonstrated raised cobalt and chromium levels in patients with larger diameter femoral heads, following metal-on-polyethylene uncemented total hip arthroplasty. Further data have been collected, to see whether these associations have altered with time and to determine the long-term implications for these patients and our practice. Patients from our previous study who underwent Trident-Accolade primary total hip arthroplasties using a metal-on-polyethylene bearing in 2009 were reviewed. Patients were invited to have their cobalt and chromium levels retested, and were provided an Oxford Hip Score. Serum ion levels were then compared between groups (28 mm, 36 mm, and 40 mm heads) and over time.Aims
Methods
Trochlear dysplasia is a significant risk factor for patellofemoral instability. The Dejour classification is currently considered the standard for classifying trochlear dysplasia, but numerous studies have reported poor reliability on both plain radiography and MRI. The severity of trochlear dysplasia is important to establish in order to guide surgical management. We have developed an MRI-specific classification system to assess the severity of trochlear dysplasia, the Oswestry-Bristol Classification (OBC). This is a four-part classification system comprising normal, mild, moderate, and severe to represent a normal, shallow, flat, and convex trochlear, respectively. The purpose of this study was to assess the inter- and intraobserver reliability of the OBC and compare it with that of the Dejour classification. Four observers (two senior and two junior orthopaedic surgeons) independently assessed 32 CT and axial MRI scans for trochlear dysplasia and classified each according to the OBC and the Dejour classification systems. Assessments were repeated following a four-week interval. The inter- and intraobserver agreement was determined by using Fleiss’ generalization of Cohen’s kappa statistic and S-statistic nominal and linear weights.Aims
Methods
We undertook a randomised clinical trial to compare
treatment times and failure rates between above- and below-knee
Ponseti casting groups. Eligible children with idiopathic clubfoot,
treated using the Ponseti method, were randomised to either below-
or above-knee plaster of Paris casting. Outcome measures were total
treatment time and the occurrence of failure, defined as two slippages
or a treatment time above eight weeks. A total of 26 children (33 feet) were entered into the trial.
The above-knee group comprised 17 feet in 13 children (ten boys
and three girls, median age 13 days (1 to 40)) and the below-knee
group comprised 16 feet in 13 children (ten boys and three girls,
median age 13 days (5 to 20)). Because of six failures (37.5%) in
the below-knee group, the trial was stopped early for ethical reasons.
The rate of failure was significantly higher in the below-knee group
(p = 0.039). The median treatment times of six weeks in the below-knee
and four weeks in the above-knee group differed significantly (p
= 0.01). This study demonstrates that the use of a below-knee plaster
of Paris cast in conjunction with the Ponseti technique leads to
unacceptably high failure rates and significantly longer treatment
times. Therefore, this technique is not recommended. Cite this article:
The revised Tokuhashi, Tomita and modified Bauer
scores are commonly used to make difficult decisions in the management
of patients presenting with spinal metastases. A prospective cohort
study of 199 consecutive patients presenting with spinal metastases,
treated with either surgery and/or radiotherapy, was used to compare
the three systems. Cox regression, Nagelkerke’s R2 and
Harrell’s concordance were used to compare the systems and find their
best predictive items. The three systems were equally good in terms
of overall prognostic performance. Their most predictive items were
used to develop the Oswestry Spinal Risk Index (OSRI), which has
a similar concordance, but a larger coefficient of determination
than any of these three scores. A bootstrap procedure was used to
internally validate this score and determine its prediction optimism. The OSRI is a simple summation of two elements: primary tumour
pathology (PTP) and general condition (GC): OSRI = PTP + (2 – GC). This simple score can predict life expectancy accurately in patients
presenting with spinal metastases. It will be helpful in making
difficult clinical decisions without the delay of extensive investigations. Cite this article:
The use of impaction bone grafting during revision arthroplasty of the hip in the presence of cortical defects has a high risk of post-operative fracture. Our laboratory study addressed the effect of extramedullary augmentation and length of femoral stem on the initial stability of the prosthesis and the risk of fracture. Cortical defects in plastic femora were repaired using either surgical mesh without extramedullary augmentation, mesh with a strut graft or mesh with a plate. After bone impaction, standard or long-stem Exeter prostheses were inserted, which were tested by cyclical loading while measuring defect strain and migration of the stem. Compared with standard stems without extramedullary augmentation, defect strains were 31% lower with longer stems, 43% lower with a plate and 50% lower with a strut graft. Combining extramedullary augmentation with a long stem showed little additional benefit (p = 0.67). The type of repair did not affect the initial stability. Our results support the use of impaction bone grafting and extramedullary augmentation of diaphyseal defects after mesh containment.
The role of bone-graft extenders in impaction revision surgery is becoming increasingly important. Tricalcium phosphate and hydroxyapatite have been shown to be both biocompatible and osteoconductive, yet many surgeons remain reluctant to use them. The difficulty in handling bone-graft extenders can be partly alleviated by using porous particles and adding clotted blood. In an Our findings showed that pure allograft bone particles had significantly higher cohesion than when mixed with extender (p <
0.001). Washing had no effect on cohesion. The addition of clotted blood significantly increased the cohesion of both pure bone (p <
0.019) and mixes with pure bone and with porous graft extender (p <
0.044).
Nomograms derived from mathematical analysis indicate that the level of malunion is the most important determinant of changes in the moment arm of the knee, the plane of the ankle and alterations in limb length. Testing in five patients undergoing reconstruction showed a mean error of postoperative limb length of 2.2 mm (
We describe a technique for measuring the Stiffness of regenerate bone after leg lengthening. This allows early identification of slow healing by reference to normal patterns. We determined the time of removal of the fixator from clinical and radiological information independent of the stiffness result. In a series of 30 leg lengthenings there were no refractures when the tibial stiffness had reached 15 Nm/° or the femoral stiffness 20 Nm/°. Three refractures occurred at lower stiffness values. The technique is simple to perform, will allow a reduction in plain radiography and is recommended for routine postoperative management.