Retrieval studies have shown that the use of fully congruent meniscal bearings reduces wear in knee replacements. We report the outcome of 143 knees with anteromedial osteoarthritis and normal anterior cruciate ligaments treated by
Satisfactory selection criteria are essential for the successful outcome of unicompartmental knee arthroplasty (UCA). We report the frequency of revision of the Oxford medial
When the Oxford unicompartmental meniscal bearing arthroplasty is used in the lateral compartment of the knee, 10% of the bearings dislocate. A radiological review was carried out to establish if dislocation was related to surgical technique. The postoperative radiographs of 46 lateral
We have made a retrospective comparison between the results of 49 high tibial osteotomies and 42
We determined the outcome of 56 ‘Oxford’
A retrospective review of medial compartment arthroplasty in 22 patients (22 knees) is reported. The operations were performed between 1973 and 1978. Eighty-six per cent were rated good or excellent using the knee rating system devised by the Hospital for Special Surgery, New York. Excellent or good results were achieved in six patients who had previously had a high tibial osteotomy. At the time of follow-up significant loosening had not occurred, although progression of patellofemoral disease was noted. This study supports the promising results reported for
Since 1974, we have made a prospective study in Bristol of the results of unicompartmental knee replacement using the St Georg sledge prosthesis. A total of 115 knees in 100 patients have been followed up for 2 to 12 years (mean, 4 years 9 months). Results have assessed both by the Bristol knee score and by survivorship studies on the total series of 138 knees. Results were excellent or good in 86% and fair or poor in 14%. The survivorship study (based on a definition of failure which included significant pain or a dissatisfied patient or the need for revision) showed a cumulative success rate of 76.4% at six years, with no further failures after that time. Seven knees have been revised, in most cases for deterioration of the contralateral compartment. The operation is recommended as a satisfactory and durable form of treatment for osteoarthritis affecting a single tibiofemoral compartment.
Aims. There has been a recent resurgence in interest in combined partial knee arthroplasty (PKA) as an alternative to total knee arthroplasty (TKA). The varied terminology used to describe these procedures leads to confusion and ambiguity in communication between surgeons, allied health professionals, and patients. A standardized classification system is required for patient safety, accurate clinical record-keeping, clear communication, correct coding for appropriate remuneration, and joint registry data collection. Materials and Methods. An advanced PubMed search was conducted, using medical subject headings (MeSH) to identify terms and abbreviations used to describe knee arthroplasty procedures. The search related to TKA, unicompartmental (UKA), patellofemoral (PFA), and combined PKA procedures. Surveys were conducted of orthopaedic surgeons, trainees, and biomechanical engineers, who were asked which of the descriptive terms and abbreviations identified from the literature search they found most intuitive and appropriate to describe each procedure. The results were used to determine a popular consensus. Results. Survey participants preferred “bi-unicondylar arthroplasty” (Bi-UKA) to describe ipsilateral medial and lateral
Medial tibial plateaux excised during 46
In a systematic review, reports from national registers and clinical studies were identified and analysed with respect to revision rates after joint replacement, which were calculated as revisions per 100 observed component years. After primary hip replacement, a mean of 1.29 revisions per 100 observed component years was seen. The results after primary total knee replacement are 1.26 revisions per 100 observed component years, and 1.53 after medial
The options for treatment of the young active patient with isolated symptomatic osteoarthritis of the medial compartment and pre-existing deficiency of the anterior cruciate ligament are limited. The potential longevity of the implant and levels of activity of the patient may preclude total knee replacement, and tibial osteotomy and unicompartmental knee arthroplasty are unreliable because of the ligamentous instability. Unicompartmental knee arthroplasties tend to fail because of wear or tibial loosening resulting from eccentric loading. Therefore, we combined reconstruction of the anterior cruciate ligament with
We present a comparison of the results of the Oxford unicompartmental knee arthroplasty in patients younger and older than 60 years of age. The ten-year all-cause survival of the <
60 years of age group (52) was 91% (95% confidence interval (CI) 12), while in the ≥ 60 years of age group (512), the figure was 96% (95% CI 3). For the younger group, the mean Hospital for Special Surgery score at ten-year follow-up (n = 21) was 94 of 100, compared with a mean of 86 of 100 for the older group (n = 135). The results show that the Oxford
Twenty patients underwent simultaneous bilateral medial unicompartmental knee arthroplasty. Pre-operative hip-knee-ankle alignment and valgus stress radiographs were used to plan the desired post-operative alignment of the limb in accordance with established principles for
This randomised trial evaluated the outcome of
a single design of
The Oxford medial unicompartmental knee replacement was designed to reproduce normal mobility and forces in the knee, but its detailed effect on the patellofemoral joint has not been studied previously. We have examined the effect on patellofemoral mechanics of the knee by simultaneously measuring patellofemoral kinematics and forces in 11 cadaver knee specimens in a supine leg-extension rig. Comparison was made between the intact normal knee and sequential unicompartmental and total knee replacement. Following medial mobile-bearing
We describe 88 knees (79 patients) with lateral unicompartmental osteoarthritis which had been treated by the St Georg Sled prosthesis. At a mean follow-up of nine years (2 to 21) 15 knees had revision surgery, nine for progression of arthritis, six for loosening, four for breakage of a component and four for more than one reason. Six patients complained of moderate or severe pain at the final follow-up. Only five knees were lost to follow-up in the 21-year period. We performed survivorship analysis on the group using revision for any cause as the endpoint. At ten years the cumulative survival rate was 83%, and at 15 years, when ten knees were still at risk, it was 74%. Based on our clinical results and survival rate the St Georg Sled may be considered to be a suitable
Osteoarthritis of the medial compartment of the knee often shows a specific pattern of anterior wear. Review of our revisions from a series of medial metal-backed Brigham unicondylar knee replacements performed between 1983 and 1989 showed that this wear pattern was common on the tibial polyethylene surface. We reviewed these cases retrospectively to compare the pattern of preoperative erosion with the wear of the prosthesis. In all 14 knees with severe anterior wear in a
We reviewed two similar groups of patients with medial osteoarthritis of the knee treated by