As adverse events related to metal on metal hip
arthroplasty have been better understood, there has been increased
interest in
Recently, the use of metal-on-metal articulations
in total hip arthroplasty (THA) has led to an increase in adverse
events owing to local soft-tissue reactions from metal ions and
wear debris. While the majority of these implants perform well,
it has been increasingly recognised that a small proportion of patients
may develop complications secondary to systemic cobalt toxicity
when these implants fail. However, distinguishing true toxicity
from benign elevations in cobalt ion levels can be challenging. . The purpose of this two part series is to review the use of cobalt
alloys in THA and to highlight the following related topics of interest:
mechanisms of cobalt ion release and their measurement, definitions
of pathological cobalt ion levels, and the pathophysiology, risk factors
and treatment of cobalt
Peri-tendinous injection of local anaesthetic,
both alone and in combination with corticosteroids, is commonly performed
in the treatment of tendinopathies. Previous studies have shown
that local anaesthetics and corticosteroids are chondrotoxic, but
their effect on tenocytes remains unknown. We compared the effects
of lidocaine and ropivacaine, alone or combined with dexamethasone,
on the viability of cultured bovine tenocytes. Tenocytes were exposed
to ten different conditions: 1) normal saline; 2) 1% lidocaine;
3) 2% lidocaine; 4) 0.2% ropivacaine; 5) 0.5% ropivacaine; 6) dexamethasone
(dex); 7) 1% lidocaine+dex; 8) 2% lidocaine+dex; 9) 0.2% ropivacaine+dex;
and 10) 0.5% ropivacaine+dex, for 30 minutes. After a 24-hour recovery
period, the viability of the tenocytes was quantified using the
CellTiter-Glo viability assay and fluorescence-activated cell sorting
(FACS) for live/dead cell counts. A 30-minute exposure to lidocaine
alone was significantly
Ketamine has been used in combination with a
variety of other agents for intra-articular analgesia, with promising results.
However, although it has been shown to be
The long-term effects of metal-on-metal arthroplasty are currently under scrutiny because of the potential biological effects of metal wear debris. This review summarises data describing the release, dissemination, uptake, biological activity, and potential
Some of the component metals of the alloys used for total joint prostheses are
The intra-articular administration of tranexamic acid (TXA) has
been shown to be effective in reducing blood loss in unicompartmental
knee arthroplasty and anterior cruciate reconstruction. The effects
on human articular cartilage, however, remains unknown. Our aim,
in this study, was to investigate any detrimental effect of TXA
on chondrocytes, and to establish if there was a safe dose for its
use in clinical practice. The hypothesis was that TXA would cause
a dose-dependent damage to human articular cartilage. The cellular morphology, adhesion, metabolic activity, and viability
of human chondrocytes when increasing the concentration (0 mg/ml
to 40 mg/ml) and length of exposure to TXA (0 to 12 hours) were
analyzed in a 2D model. This was then repeated, excluding cellular
adhesion, in a 3D model and confirmed in viable samples of articular cartilage.Aims
Materials and Methods
Aims. Intra-articular administration of antibiotics during primary total knee arthroplasty (TKA) may represent a safe, cost-effective strategy to reduce the risk of acute periprosthetic joint infection (PJI). Vancomycin with an aminoglycoside provides antimicrobial cover for most organisms isolated from acute PJI after TKA. However, the intra-articular doses required to achieve sustained therapeutic intra-articular levels while remaining below
This in vivo controlled laboratory
study was performed to evaluate various intra-articular clinical
injection regimes that might be less
Periprosthetic joint infection (PJI) is one of the most dreaded complications after arthroplasty surgery; thus numerous approaches have been undertaken to equip metal surfaces with antibacterial properties. Due to its antimicrobial effects, silver is a promising coating for metallic surfaces, and several types of silver-coated arthroplasty implants are in clinical use today. However, silver can also exert
Aims. To evaluate the effect of a single early high-dose vitamin D
supplement on fracture union in patients with hypovitaminosis D
and a long bone fracture. Patients and Methods. Between July 2011 and August 2013, 113 adults with a long bone
fracture were enrolled in a prospective randomised double-blind
placebo-controlled trial. Their serum vitamin D levels were measured
and a total of 100 patients were found to be vitamin D deficient
(<
20 ng/ml) or insufficient (<
30 ng/mL). These were then
randomised to receive a single dose of vitamin D. 3. orally
(100 000 IU) within two weeks of injury (treatment group, n = 50)
or a placebo (control group, n = 50). We recorded patient demographics,
fracture location and treatment, vitamin D level, time to fracture
union and complications, including vitamin D
Aims. In the absence of an identified organism, single-stage revision is contraindicated in prosthetic joint infection (PJI). However, no studies have examined the use of intra-articular antibiotics in combination with single-stage revision in these cases. In this study, we present the results of single-stage revision using intra-articular antibiotic infusion for treating culture-negative (CN) PJI. Methods. A retrospective analysis between 2009 and 2016 included 51 patients with CN PJI who underwent single-stage revision using intra-articular antibiotic infusion; these were compared with 192 culture-positive (CP) patients. CN patients were treated according to a protocol including intravenous vancomycin and a direct intra-articular infusion of imipenem and vancomycin alternately used in the morning and afternoon. In the CP patients, pathogen-sensitive intravenous (IV) antibiotics were administered for a mean of 16 days (12 to 21), and for resistant cases, additional intra-articular antibiotics were used. The infection healing rate, Harris Hip Score (HHS), and Hospital for Special Surgery (HSS) knee score were compared between CN and CP groups. Results. Of 51 CN patients, 46 (90.2%) required no additional medical treatment for recurrent infection at a mean of 53.2 months (24 to 72) of follow-up. Impaired kidney function occurred in two patients, and one patient had a local skin rash. No significant difference in the infection control rate was observed between CN and CP PJIs (90.2% (46/51) versus 94.3% (181/192); p = 0.297). The HHS of the CN group showed no substantial difference from that of CP cases (79 versus 81; p = 0.359). However, the CN group showed a mean HSS inferior to that of the CP group (76 versus 80; p = 0.027). Conclusion. Single-stage revision with direct intra-articular antibiotic infusion can be effective in treating CN PJI, and can achieve an infection control rate similar to that in CP patients. However, in view of systemic
Symptomatic cobalt
A silver-containing hydroxyapatite (Ag-HA) coating has been developed using thermal spraying technology. We evaluated the osteoconductivity of this coating on titanium (Ti) implants in rat tibiae in relation to bacterial infection in joint replacement. At 12 weeks, the mean affinity indices of bone formation of a Ti, an HA, a 3%Ag-HA and a 50%Ag-HA coating were 97.3%, 84.9%, 81.0% and 40.5%, respectively. The mean affinity indices of bone contact of these four coatings were 18.8%, 83.7%, 77.2% and 40.5%, respectively. The indices of bone formation and bone contact around the implant of the 3%Ag-HA coating were similar to those of the HA coating, and no significant differences were found between them (bone formation, p = 0.99; bone contact, p = 0.957). However, inhibition of bone formation was observed with the 50%Ag-HA coating. These results indicate that the 3%Ag-HA coating has low
Aims. Calcium sulphate (CaSO. 4. ) is a resorbable material
that can be used simultaneously as filler of a dead space and as
a carrier for the local application of antibiotics. Our aim was
to describe the systemic exposure and the wound fluid concentrations
of vancomycin in patients treated with vancomycin-loaded CaSO. 4. as
an adjunct to the routine therapy of bone and joint infections. Patients and Methods. A total of 680 post-operative blood and 233 wound fluid samples
were available for analysis from 94 implantations performed in 87
patients for various infective indications. Up to 6 g of vancomycin
were used. Non-compartmental pharmacokinetic analysis was performed
on the data from 37 patients treated for an infection of the hip. Results. The overall systemic exposure remained within a safe range, even
in patients with post-operative renal failure, none requiring removal
of the pellets. Local concentrations were approximately ten times
higher than with polymethylmethacrylate (PMMA) as a carrier, but
remained below reported cell
External fixation is widely used in orthopaedic
and trauma surgery. Infections around pin or wire sites, which are usually
localised, non-invasive, and are easily managed, are common. Occasionally,
more serious invasive complications such as necrotising fasciitis
(NF) and
Desmoid tumours are a rare fibroblastic proliferation of monoclonal origin, arising in deep soft-tissues. Histologically, they are characterized by locally aggressive behaviour and an inability to metastasize, and clinically by a heterogeneous and unpredictable course. Desmoid tumours can occur in any anatomical site, but commonly arise in the limbs. Despite their benign nature, they can be extremely disabling and sometimes life-threatening, causing severe pain and functional limitations. Their surgical management is complex and challenging, due to uncertainties surrounding the biological and clinical behaviour, rarity, and limited available literature. Resection has been the first-line approach for patients with a desmoid tumour but, during the last few decades, a shift towards a more conservative approach has occurred, with an initial ‘wait and see’ policy. Many medical and regional forms of treatment are also available for the management of this condition, and others have recently emerged with promising results. However, many areas of controversy remain, and further studies and global collaboration are needed to obtain prospective and randomized data, in order to develop an appropriate shared stepwise approach. Cite this article:
The recently published Prophylactic Antibiotic Regimens In Tumor Surgery (PARITY) trial found no benefit in extending antibiotic prophylaxis from 24 hours to five days after endoprosthetic reconstruction for lower limb bone tumours. PARITY is the first randomized controlled trial in orthopaedic oncology and is a huge step forward in understanding antibiotic prophylaxis. However, significant gaps remain, including questions around antibiotic choice, particularly in the UK, where cephalosporins are avoided due to concerns of Cite this article:
Gram-negative periprosthetic joint infection (PJI) has been poorly studied despite its rapidly increasing incidence. Treatment with one-stage revision using intra-articular (IA) infusion of antibiotics may offer a reasonable alternative with a distinct advantage of providing a means of delivering the drug in high concentrations. Carbapenems are regarded as the last line of defense against severe Gram-negative or polymicrobial infection. This study presents the results of one-stage revision using intra-articular carbapenem infusion for treating Gram-negative PJI, and analyzes the characteristics of bacteria distribution and drug sensitivity. We retrospectively reviewed 32 patients (22 hips and 11 knees) who underwent single-stage revision combined with IA carbapenem infusion between November 2013 and March 2020. The IA and intravenous (IV) carbapenem infusions were administered for a single Gram-negative infection, and IV vancomycin combined with IA carbapenems and vancomycin was applied for polymicrobial infection including Gram-negative bacteria. The bacterial community distribution, drug sensitivity, infection control rate, functional recovery, and complications were evaluated. Reinfection or death caused by PJI was regarded as a treatment failure.Aims
Methods