Advertisement for orthosearch.org.uk
Results 1 - 20 of 35
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 419 - 421
1 May 1996
Apergis E Dimitrakopoulos K Chorianopoulos K Theodoratos G

Only a few cases of palmar carpal subluxation associated with an ulnovolar fragment from the distal radius have been reported previously. We report a case which was treated operatively six months after the injury


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1196 - 1200
1 Nov 2023
Parker MJ Chatterjee R Onsa M Cawley S Gurusamy K

Aims

The aim of this study was to report the three-year follow-up for a series of 400 patients with a displaced intracapsular fracture of the hip, who were randomized to be treated with either a cemented polished tapered hemiarthroplasty or an uncemented hydroxyapatite-coated hemiarthroplasty.

Methods

The mean age of the patients was 85 years (58 to 102) and 273 (68%) were female. Follow-up was undertaken by a nurse who was blinded to the hemiarthroplasty that was used, at intervals for up to three years from surgery. The short-term follow-up of these patients at a mean of one year has previously been reported.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1020 - 1029
1 Sep 2023
Trouwborst NM ten Duis K Banierink H Doornberg JN van Helden SH Hermans E van Lieshout EMM Nijveldt R Tromp T Stirler VMA Verhofstad MHJ de Vries JPPM Wijffels MME Reininga IHF IJpma FFA

Aims

The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures.

Methods

A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 151 - 159
1 Feb 2013
Duckworth AD McQueen MM Ring D

Most fractures of the radial head are stable undisplaced or minimally displaced partial fractures without an associated fracture of the elbow or forearm or ligament injury, where stiffness following non-operative management is the primary concern. Displaced unstable fractures of the radial head are usually associated with other fractures or ligament injuries, and restoration of radiocapitellar contact by reconstruction or prosthetic replacement of the fractured head is necessary to prevent subluxation or dislocation of the elbow and forearm. In fractures with three or fewer fragments (two articular fragments and the neck) and little or no metaphyseal comminution, open reduction and internal fixation may give good results. However, fragmented unstable fractures of the radial head are prone to early failure of fixation and nonunion when fixed. Excision of the radial head is associated with good long-term results, but in patients with instability of the elbow or forearm, prosthetic replacement is preferred. This review considers the characteristics of stable and unstable fractures of the radial head, as well as discussing the debatable aspects of management, in light of the current best evidence. Cite this article: Bone Joint J 2013;95-B:151–9


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1347 - 1351
1 Oct 2007
Maquieira GJ Espinosa N Gerber C Eid K

The generally-accepted treatment for large, displaced fractures of the glenoid associated with traumatic anterior dislocation of the shoulder is operative repair. In this study, 14 consecutive patients with large (> 5 mm), displaced (> 2 mm) anteroinferior glenoid rim fractures were treated non-operatively if post-reduction radiographs showed a centred glenohumeral joint. After a mean follow-up of 5.6 years (2.8 to 8.4), the mean Constant score and subjective shoulder value were 98% (90% to 100%) and 97% (90% to 100%), respectively. There were no redislocations or subluxations, and the apprehension test was negative. All fragments healed with an average intra-articular step of 3.0 mm (0.5 to 11). No patient had symptoms of osteoarthritis, which was mild in two shoulders and moderate in one. Traumatic anterior dislocation of the shoulder, associated with a large displaced glenoid rim fracture can be successfully treated non-operatively, providing the glenohumeral joint is concentrically reduced on the anteroposterior radiograph


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1063 - 1069
1 Jun 2021
Amundsen A Brorson S Olsen BS Rasmussen JV

Aims

There is no consensus on the treatment of proximal humeral fractures. Hemiarthroplasty has been widely used in patients when non-surgical treatment is not possible. There is, despite extensive use, limited information about the long-term outcome. Our primary aim was to report ten-year patient-reported outcome after hemiarthroplasty for acute proximal humeral fractures. The secondary aims were to report the cumulative revision rate and risk factors for an inferior patient-reported outcome.

Methods

We obtained data on 1,371 hemiarthroplasties for acute proximal humeral fractures from the Danish Shoulder Arthroplasty Registry between 2006 and 2010. Of these, 549 patients (40%) were alive and available for follow-up. The Western Ontario Osteoarthritis of the Shoulder (WOOS) questionnaire was sent to all patients at nine to 14 years after primary surgery. Revision rates were calculated using the Kaplan-Meier method. Risk factors for an inferior WOOS score were analyzed using the linear regression model.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 746 - 754
1 Apr 2021
Schnetzke M El Barbari J Schüler S Swartman B Keil H Vetter S Gruetzner PA Franke J

Aims

Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation.

Methods

A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days).


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1229 - 1241
14 Sep 2020
Blom RP Hayat B Al-Dirini RMA Sierevelt I Kerkhoffs GMMJ Goslings JC Jaarsma RL Doornberg JN

Aims

The primary aim of this study was to address the hypothesis that fracture morphology might be more important than posterior malleolar fragment size in rotational type posterior malleolar ankle fractures (PMAFs). The secondary aim was to identify clinically important predictors of outcome for each respective PMAF-type, to challenge the current dogma that surgical decision-making should be based on fragment size.

Methods

This observational prospective cohort study included 70 patients with operatively treated rotational type PMAFs, respectively: 23 Haraguchi Type I (large posterolateral-oblique), 22 Type II (two-part posterolateral and posteromedial), and 25 (avulsion-) Type III. There was no standardized protocol on how to address the PMAFs and CT-imaging was used to classify fracture morphology and quality of postoperative syndesmotic reduction. Quantitative 3D-CT (Q3DCT) was used to assess the quality of fracture reduction, respectively: the proportion of articular involvement; residual intra-articular: gap, step-off, and 3D-displacement; and residual gap and step-off at the fibular notch. These predictors were correlated with the Foot and Ankle Outcome Score (FAOS) at two-years follow-up.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 918 - 924
1 Jul 2020
Rosslenbroich SB Heimann K Katthagen JC Koesters C Riesenbeck O Petersen W Raschke MJ Schliemann B

Aims

There is a lack of long-term data for minimally invasive acromioclavicular (AC) joint repair. Furthermore, it is not clear if good early clinical results can be maintained over time. The purpose of this study was to report long-term results of minimally invasive AC joint reconstruction (MINAR) and compare it to corresponding short-term data.

Methods

We assessed patients with a follow-up of at least five years after minimally invasive flip-button repair for high-grade AC joint dislocation. The clinical outcome was evaluated using the Constant score and a questionnaire. Ultrasound determined the coracoclavicular (CC) distance. Results of the current follow-up were compared to the short-term results of the same cohort.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 964 - 972
1 Jul 2017
Duckworth AD Clement ND McEachan JE White TO Court-Brown CM McQueen MM

Aims

The aim of this prospective randomised controlled trial was to compare non-operative and operative management for acute isolated displaced fractures of the olecranon in patients aged ≥ 75 years.

Patients and Methods

Patients were randomised to either non-operative management or operative management with either tension-band wiring or fixation with a plate. They were reviewed at six weeks, three and six months and one year after the injury. The primary outcome measure was the Disabilities of the Arm, Shoulder and Hand (DASH) score at one year.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 693 - 702
1 Jun 2018
Jayakumar P Overbeek CL Vranceanu A Williams M Lamb S Ring D Gwilym S

Aims

Outcome measures quantifying aspects of health in a precise, efficient, and user-friendly manner are in demand. Computer adaptive tests (CATs) may overcome the limitations of established fixed scales and be more adept at measuring outcomes in trauma. The primary objective of this review was to gain a comprehensive understanding of the psychometric properties of CATs compared with fixed-length scales in the assessment of outcome in patients who have suffered trauma of the upper limb. Study designs, outcome measures and methodological quality are defined, along with trends in investigation.

Materials and Methods

A search of multiple electronic databases was undertaken on 1 January 2017 with terms related to “CATs”, “orthopaedics”, “trauma”, and “anatomical regions”. Studies involving adults suffering trauma to the upper limb, and undergoing any intervention, were eligible. Those involving the measurement of outcome with any CATs were included. Identification, screening, and eligibility were undertaken, followed by the extraction of data and quality assessment using the Consensus-Based Standards for the Selection of Health Measurement Instruments (COSMIN) criteria. The review is reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria and reg

istered (PROSPERO: CRD42016053886).


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 95 - 100
1 Jan 2018
Evers J Fischer M Zderic I Wähnert D Richards RG Gueorguiev B Raschke MJ Ochman S

Aims

The aim of this study was to investigate the effect of a posterior malleolar fragment (PMF), with < 25% ankle joint surface, on pressure distribution and joint-stability. There is still little scientific evidence available to advise on the size of PMF, which is essential to provide treatment. To date, studies show inconsistent results and recommendations for surgical treatment date from 1940.

Materials and Methods

A total of 12 cadaveric ankles were assigned to two study groups. A trimalleolar fracture was created, followed by open reduction and internal fixation. PMF was fixed in Group I, but not in Group II. Intra-articular pressure was measured and cyclic loading was performed.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1665 - 1676
1 Dec 2017
Stinton SB Graham PL Moloney NA Maclachlan LR Edgar DW Pappas E

Aims

To synthesise the literature and perform a meta-analysis detailing the longitudinal recovery in the first two years following a distal radius fracture (DRF) managed with volar plate fixation.

Materials and Methods

Three databases were searched to identify relevant articles. Following eligibility screening and quality assessment, data were extracted and outcomes were assimilated at the post-operative time points of interest. A state-of-the-art longitudinal mixed-effects meta-analysis model was employed to analyse the data.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1693 - 1697
1 Dec 2015
Keightley AJ Nawaz SZ Jacob JT Unnithan A Elliott DS Khaleel A

This study aimed to determine the long-term functional, clinical and radiological outcomes in patients with Schatzker IV to VI fractures of the tibial plateau treated with an Ilizarov frame. Clinical, functional and radiological assessment was carried out at a minimum of one year post-operatively. A cohort of 105 patients (62 men, 43 women) with a mean age of 49 years (15 to 87) and a mean follow-up of 7.8 years (1 to 19) were reviewed. There were 18 type IV, 10 type V and 77 type VI fractures. All fractures united with a mean time to union of 20.1 weeks (10.6 to 42.3). No patient developed a deep infection. The median range of movement (ROM) of the knee was 110o and the median Iowa score was 85.

Our study demonstrates good long-term functional outcome with no deep infection; spanning the knee had no detrimental effect on the ROM or functional outcome.

High-energy fractures of the tibial plateau may be treated effectively with a fine wire Ilizarov fixator.

Cite this article: Bone Joint J 2015;97-B:1693–7.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 1004 - 1006
1 Jul 2015
Middleton SD McNiven N Griffin EJ Anakwe RE Oliver CW

We define the long-term outcomes and rates of further operative intervention following displaced Bennett’s fractures treated with Kirschner (K-) wire fixation between 1996 and 2009. We retrospectively identified 143 patients (127 men and 16 women) with a mean age at the time of injury of 33.2 years (18 to 75). Electronic records were examined and patients were invited to complete the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire in addition to a satisfaction questionnaire. The time since injury was a mean of 11.5 years (3.4 to 18.5). In total 11 patients had died, one had developed dementia and 12 patients were lost to follow-up. This left 119 patients available for recruitment. Of these, 57 did not respond, leaving a study group of 62 patients. Patients reported excellent functional outcomes and high levels of satisfaction at follow-up. Median satisfaction was 94% (interquartile range 91.5 to 97.5) and the mean DASH score was 3.0 (0 to 38). None of the patients had undergone salvage procedures and none of the responders had changed occupation or sporting activities. Long-term patient reported outcomes following displaced Bennett’s fractures treated by closed reduction and K-wire fixation show excellent functional results and a high level of patient satisfaction. The rate of infection is low and similar to other surgical procedures with percutaneous K-wires.

Cite this article: Bone Joint J 2015;97-B:1004–6.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1126 - 1131
1 Aug 2015
Nortunen S Flinkkilä T Lantto I Kortekangas T Niinimäki J Ohtonen P Pakarinen H

We prospectively assessed the diagnostic accuracy of the gravity stress test and clinical findings to evaluate the stability of the ankle mortise in patients with supination–external rotation-type fractures of the lateral malleolus without widening of the medial clear space. The cohort included 79 patients with a mean age of 44 years (16 to 82). Two surgeons assessed medial tenderness, swelling and ecchymosis and performed the external rotation (ER) stress test (a reference standard). A diagnostic radiographer performed the gravity stress test.

For the gravity stress test, the positive likelihood ratio (LR) was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate change from the pre-test probability. Medial tenderness, both alone and in combination with swelling and/or ecchymosis, indicated a small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47), whereas swelling and ecchymosis indicated only minimal changes (positive LR, 1.41 to 1.65; negative LR, 0.38 to 0.47).

In conclusion, when gravity stress test results are in agreement with clinical findings, the result is likely to predict stability of the ankle mortise with an accuracy equivalent to ER stress test results. When clinical examination suggests a medial-side injury, however, the gravity stress test may give a false negative result.

Cite this article: Bone Joint J 2015; 97-B:1126–31.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1107 - 1112
1 Aug 2012
Bugler KE Watson CD Hardie AR Appleton P McQueen MM Court-Brown CM White TO

Techniques for fixation of fractures of the lateral malleolus have remained essentially unchanged since the 1960s, but are associated with complication rates of up to 30%. The fibular nail is an alternative method of fixation requiring a minimal incision and tissue dissection, and has the potential to reduce the incidence of complications.

We reviewed the results of 105 patients with unstable fractures of the ankle that were fixed between 2002 and 2010 using the Acumed fibular nail. The mean age of the patients was 64.8 years (22 to 95), and 80 (76%) had significant systemic medical comorbidities. Various different configurations of locking screw were assessed over the study period as experience was gained with the device. Nailing without the use of locking screws gave satisfactory stability in only 66% of cases (4 of 6). Initial locking screw constructs rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable. Overall, seven patients had loss of fixation of the fracture and there were five post-operative wound infections related to the distal fibula. This lead to the development of the current technique with a screw across the syndesmosis in addition to a distal locking screw. In 21 patients treated with this technique there have been no significant complications and only one superficial wound infection. Good fracture reduction was achieved in all of these patients. The mean physical component Short-Form 12, Olerud and Molander score, and American Academy of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean of six years post-injury were 46 (28 to 61), 65 (35 to 100) and 83 (52 to 99), respectively. There have been no cases of fibular nonunion.

Nailing of the fibula using our current technique gives good radiological and functional outcomes with minimal complications, and should be considered in the management of patients with an unstable ankle fracture.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 109 - 114
1 Jan 2015
Haller JM Holt DC McFadden ML Higgins TF Kubiak EN

The aim of this study was to report the incidence of arthrofibrosis of the knee and identify risk factors for its development following a fracture of the tibial plateau. We carried out a retrospective review of 186 patients (114 male, 72 female) with a fracture of the tibial plateau who underwent open reduction and internal fixation. Their mean age was 46.4 years (19 to 83) and the mean follow-up was16.0 months (6 to 80).

A total of 27 patients (14.5%) developed arthrofibrosis requiring a further intervention. Using multivariate regression analysis, the use of a provisional external fixator (odds ratio (OR) 4.63, 95% confidence interval (CI) 1.26 to 17.7, p = 0.021) was significantly associated with the development of arthrofibrosis. Similarly, the use of a continuous passive movement (CPM) machine was associated with significantly less development of arthrofibrosis (OR = 0.32, 95% CI 0.11 to 0.83, p = 0.024). The effect of time in an external fixator was found to be significant, with each extra day of external fixation increasing the odds of requiring manipulation under anaesthesia (MUA) or quadricepsplasty by 10% (OR = 1.10, p = 0.030). High-energy fracture, surgical approach, infection and use of tobacco were not associated with the development of arthrofibrosis. Patients with a successful MUA had significantly less time to MUA (mean 2.9 months; sd 1.25) than those with an unsuccessful MUA (mean 4.86 months; sd 2.61, p = 0.014). For those with limited movement, therefore, performing an MUA within three months of the injury may result in a better range of movement.

Based our results, CPM following operative fixation for a fracture of the tibial plateau may reduce the risk of the development of arthrofibrosis, particularly in patients who also undergo prolonged provisional external fixation.

Cite this article: Bone Joint J 2015;97-B:109–14.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 646 - 651
1 May 2014
Mutch J Laflamme GY Hagemeister N Cikes A Rouleau DM

In this study, we describe a morphological classification for greater tuberosity fractures of the proximal humerus. We divided these fractures into three types: avulsion, split and depression. We retrospectively reviewed all shoulder radiographs showing isolated greater tuberosity fractures in a Level I trauma centre between July 2007 and July 2012. We identified 199 cases where records and radiographs were reviewed and included 79 men and 120 women with a mean age of 58 years (23 to 96). The morphological classification was applied to the first 139 cases by three reviewers on two occasions using the Kappa statistic and compared with the AO and Neer classifications. The inter- and intra-observer reliability of the morphological classification was 0.73 to 0.77 and 0.69 to 0.86, respectively. This was superior to the Neer (0.31 to 0.35/0.54 to 0.63) and AO (0.30 to 0.32/0.59 to 0.65) classifications. The distribution of avulsion, split and depression type fractures was 39%, 41%, and 20%, respectively. This classification of greater tuberosity fractures is more reliable than the Neer or AO classifications. These distinct fracture morphologies are likely to have implications in terms of pathophysiology and surgical technique.

Cite this article: Bone Joint J 2014;96-B:646–51.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1557 - 1566
1 Nov 2012
Jameson SS Kyle J Baker PN Mason J Deehan DJ McMurtry IA Reed MR

United Kingdom National Institute for Health and Clinical Excellence guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractures of the femoral neck in cognitively intact patients, who were independently mobile prior to the injury. This study aimed to analyse the risk factors associated with revision of the implant and mortality following THR, and to quantify risk. National Joint Registry data recording a THR performed for acute fracture of the femoral neck between 2003 and 2010 were analysed. Cox proportional hazards models were used to investigate the extent to which risk of revision was related to specific covariates. Multivariable logistic regression was used to analyse factors affecting peri-operative mortality (< 90 days). A total of 4323 procedures were studied. There were 80 patients who had undergone revision surgery at the time of censoring (five-year revision rate 3.25%, 95% confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients died within 90 days. After adjusting for patient and surgeon characteristics, an increased risk of revision was associated with the use of cementless prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021). Revision was independent of bearing surface and head size. The risk of mortality within 90 days was significantly increased with higher American Society of Anesthesiologists (ASA) grade (grade 3: odds ratio (OR) 4.04, p < 0.001; grade 4/5: OR 20.26, p < 0.001; both compared with grades 1/2) and older age (≥ 75 years: OR 1.65, p = 0.025), but reduced over the study period (9% relative risk reduction per year).

THR is a good option in patients aged < 75 years and with ASA 1/2. Cementation of the femoral component does not adversely affect peri-operative mortality but improves survival of the implant in the mid-term when compared with cementless femoral components. There are no benefits of using head sizes > 28 mm or bearings other than metal-on-polyethylene. More research is required to determine the benefits of THR over hemiarthroplasty in older patients and those with ASA grades > 2.