Advertisement for orthosearch.org.uk
Results 1 - 20 of 119
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 818 - 823
1 Sep 1994
Hems T Clutton R Glasby M

An experimental model was established to investigate the possibility of repairing cervical nerve roots avulsed from the spinal cord, as occurs in traction injuries of the brachial plexus. In five sheep the C6 root was avulsed and the ventral root was reattached using freeze-thawed muscle as a short graft (0.5 cm). Recovery was assessed after one year by electrophysiology and histology. Stimulation of the root produced muscle contractions in four out of five sheep. Action potentials were recorded distal to the grafts in all five sheep. Histological examination showed regenerated fibres in the ventral roots in all cases. These fibres could be traced distally to the brachial plexus. Our study confirms that motor fibres can regenerate out of the spinal cord into the ventral roots and reinnervate muscles, and suggests that reimplantation of avulsed roots is a surgical option in selected cases of traction injury of the brachial plexus


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 889 - 893
1 Sep 1990
Yamamuro T Shikata J Okumura H Kitsugi T Kakutani Y Matsui T Kokubo T

We prepared a prosthesis for the replacement of the lumbar vertebrae of sheep, using apatite- and wollastonite-containing glass-ceramic. The material is stronger than human cortical bone and has the special feature of chemical bonding to bone. Ten sheep underwent replacement of L3 and L4 vertebrae, without bone grafting. The animals were killed at intervals from three months to 27 months after operation, and the interface between the prosthesis and bone was examined radiologically, histologically and crystallographically. Bone bonding with the prosthesis had occurred in half the implants. It took at least one year for bonding to be complete, but an apatite layer on the surface of the prosthesis was observed as early as three months after the operation, suggesting the possibility of much earlier bone bonding if more rigid fixation of the prosthesis had been provided


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 910 - 917
1 Nov 1992
Kohn D Wirth C Reiss G Plitz W Maschek H Erhardt W Wulker N

In 20 skeletally mature female merino sheep, divided into four groups, we performed total medial meniscectomy, removal of the middle third of the patellar tendon, and tenotomy of the calcaneal tendon of the right hind leg. Group I (control) had no additional procedures. In the other three groups the medial meniscus was replaced by the middle third of the patellar tendon from the ipsilateral knee. The animals were killed at three (group II), six (group III), or 12 months (group IV) and the tendon-meniscus examined macroscopically, by light and scanning electron microscopy, and biomechanically. Remodelling of the tissue had taken place by 12 months but the failure stress and tensile modulus for the tendon-meniscus were lower than for the normal meniscus. Our evidence suggests that, in sheep, replacement of a meniscus by a tendon autograft may decrease the severity of the degenerative changes that occur after meniscectomy


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 246 - 253
1 Feb 2008
Coathup M Smith N Kingsley C Buckland T Dattani R Ascroft GP Blunn G

An experimental sheep model was used for impaction allografting of 12 hemiarthroplasty femoral components placed into two equal-sized groups. In group 1, a 50:50 mixture of ApaPore hydroxyapatite bone-graft substitute and allograft was used. In group 2, ApaPore and allograft were mixed in a 90:10 ratio. Both groups were killed at six months. Ground reaction force results demonstrated no significant differences (p > 0.05) between the two groups at 8, 16 and 24 weeks post-operatively, and all animals remained active. The mean bone turnover rates were significantly greater in group 1, at 0.00206 mm/day, compared to group 2 at 0.0013 mm/day (p < 0.05). The results for the area of new bone formation demonstrated no significant differences (p > 0.05) between the two groups. No significant differences were found between the two groups in thickness of the cement mantle (p > 0.05) and percentage ApaPore-bone contact (p > 0.05). The results of this animal study demonstrated that a mixture of ApaPore allograft in a 90:10 ratio was comparable to using a 50:50 mixture


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 463 - 469
1 May 1985
Law H Annan I McCarthy I Hughes S Stead A Camburn M Montgomery H

We have investigated the effect of currents induced by electromagnetic fields on the healing of the tibia of sheep after osteotomy, using objective and quantifiable criteria wherever possible. A battery-powered, induction apparatus was developed and was enclosed within the cast applied to the limb, so that the treated fractures received pulsed magnetic fields for 24 hours a day while the animals were freely mobile. In all, 13 sheep were treated and 13 were used as controls. The response was assessed by radiography of the limb and of the excised bone, by histology, including measurement of the areas of callus, fibrocallus and cortical bone, and by measurement of the uptake and extraction of bone-seeking mineral. All the bones healed and no statistically significant differences between the treated animals and the controls were discovered except (at only P less than 0.05) in the uptake of bone-seeking mineral; this increased more rapidly in treated animals over the two to three weeks after osteotomy, although at six weeks the uptake in both groups was the same


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 918 - 922
1 Nov 1992
Hems T Glasby M

An experimental model was established to investigate the possibility of repairing cervical nerve roots damaged above the dorsal root ganglion, as occurs in traction injuries of the brachial plexus. In four sheep the C6 root was divided and repaired within the dura using freeze-thawed muscle grafts. Recovery was assessed after eight months by electrophysiology and histology. Action potentials were recorded distal to the grafts in all four sheep, indicating regeneration of motor fibres. Histological examination showed regenerated fibres in the ventral roots below the grafts in all cases. These fibres could be traced distally to the brachial plexus. There was no evidence of recovery of dorsal roots


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 313 - 316
1 Mar 1985
Howard C McKibbin B Ralis Z

We have studied the use of filamentous polyglycolic acid (Dexon) for the induction of neotendon in the calcaneal tendon of sheep. Uniformly good results were obtained, with the formation of a thick neotendon. However, in a control group the power of spontaneous regeneration of the tendon was studied; it was found that, provided overlengthening of the gap was prevented, an equally good tendon resulted. It is concluded that this particular model is not an appropriate one for testing neotendon induction, despite its use for this purpose in the past. The favourable results of using filamentous polyglycolic acid as a tendon replacement suggest that it should be further investigated (in a more suitable model) since it may well have useful clinical applications


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 390 - 396
1 May 1988
Laws G Walton M

A method is described which produces an isolated Grade II injury in the medial collateral ligament of the sheep's knee. The untreated injury was followed in 32 animals for up to six weeks. Histology revealed progressive healing of the lesions by a cellular response mediated by fibrocytes rather than by the classically described inflammatory response. Mechanical testing showed that the tensile strength of the ligament was initially reduced to 13% of normal but that strength and compliance were regained after six weeks


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 605 - 613
1 Jul 1992
Amis A Camburn M Kempson S Radford W Stead A

We excised the anterior cruciate ligament from the left stifle of 24 sheep and replaced it by a polyester fibre implant routed 'over the top' of the femoral condyle and fixed, using grommets and screws. All the joints were sound, and the animals moved normally until they were killed at six, 12 and 24 months after operation. We found that the implants were always covered by host tissue, which matured into bundles with a histological appearance similar to the natural ligament. The implants were joined to the bones by organised fibrous tissue and there was no anchorage loosening. There was no synovitis, but the operated joints showed progressive cartilage degeneration. The reconstructed joints became less stable immediately after operation, but regained normal stability as the neoligaments developed. The neoligaments lost strength with time, despite tissue ingrowth. The good functional, biomechanical, and histological results justify clinical trials of this type of implant


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 411 - 415
1 Mar 2006
Challis MJ Gaston P Wilson K Jull GA Crawford R

The aim of this randomised, controlled in vivo study in an ovine model was to investigate the effect of cylic pneumatic pressure on fracture healing. We performed a transverse osteotomy of the right radius in 37 sheep. They were randomised to a control group or a treatment group where they received cyclic loading of the osteotomy by the application of a pressure cuff around the muscles of the proximal forelimb. Sheep from both groups were killed at four or six weeks. Radiography, ultrasonography, biomechanical testing and histomorphometry were used to assess the differences between the groups. The area of periosteal callus, peak torsional strength, fracture stiffness, energy absorbed over the first 10° of torsion and histomorphometric analysis all showed that the osteotomies treated with the cyclic pneumatic pressure at four weeks were not significantly different from the control osteotomies at six weeks


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1533 - 1538
1 Nov 2006
Meyer DC Lajtai G von Rechenberg B Pfirrmann CWA Gerber C

We released the infraspinatus tendons of six sheep, allowed retraction of the musculotendinous unit over a period of 40 weeks and then performed a repair. We studied retraction of the musculotendinous unit 35 weeks later using CT, MRI and macroscopic dissection. The tendon was retracted by a mean of 4.7 cm (3.8 to 5.1) 40 weeks after release and remained at a mean of 4.2 cm (3.3 to 4.7) 35 weeks after the repair. Retraction of the muscle was only a mean of 2.7 cm (2.0 to 3.3) and 1.7 cm (1.1 to 2.2) respectively at these two points. Thus, the musculotendinous junction had shifted distally by a mean of 2.5 cm (2.0 to 2.8) relative to the tendon. Sheep muscle showed an ability to compensate for approximately 60% of the tendon retraction in a hitherto unknown fashion. Such retraction may not be a quantitatively reliable indicator of retraction of the muscle and may overestimate the need for elongation of the musculotendinous unit during repair


The Journal of Bone & Joint Surgery British Volume
Vol. 55-B, Issue 2 | Pages 402 - 417
1 May 1973
Salama R Burwell RG Dickson IR

1. This paper reports a histological study of the fate of sheep and calf cancellous bone grafts impregnated with autologous red marrow of Wistar rats and implanted intramuscularly as composite xenograft-autografts for two to twelve weeks. It also includes some biochemical estimations of certain types of sheep and calf bone used to prepare these composite grafts. 2. Only one of 223 devitalised bone xenografts implanted without autologous marrow formed new bone; in contrast 216 of 223 transplanted with marrow formed new bone. 3. The new bone formed by the composite grafts is derived from the autologous marrow. There was no evidence for an inductive effect upon the marrow of the various types of xenograft bone studied as described previously for allograft bone (Burwell 1966). 4. The highest score of new bone formation was found in composite grafts based on fully deproteinised sheep iliac bone prepared at Oswestry. Statistically this score was significantly higher than those registered by composite grafts prepared from intact (frozen and freeze-dried), decalcified (frozen and freeze-dried) and Kiel sheep bone, and by Kiel and Oswestry calf bone (Table II). 5. The histological evidence reported suggests that the high score with the sheep Oswestry composite grafts is because Oswestry bone is feebly immunogenic, if at all; and that such feeble or absent immunogenicity permits more marrow cells to differentiate into osteoblasts and lay down new bone without impediment. 6. The lower scores of new bone formation in most of the undeproteinised composite grafts of sheep origin–intact frozen, intact freeze-dried and Kiel–are attributed to residual immunogenicity within the organic material of the donor bone, because each type evoked the formation of mature plasma cells. 7. The Kiel bone grafts appeared to evoke less of a plasma cell reaction and may be less immunogenic than the intact and decalcified bone xenografts. 8. The sheep Oswestry CXA's formed significantly more new bone than did the calf Oswestry CXA's. This difference may be due to the different physical properties of the bone obtained from old sheep compared with the bone obtained from a young calf


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 4 | Pages 598 - 602
1 Aug 1984
Peltonen J Karaharju E Alitalo I

Angular deformities of the distal radius of 15 sheep were induced by asymmetrical epiphysial distraction. Eleven sheep were between 10 and 20 weeks old; four were older than 24 weeks. Gradual distraction on the medial side of the limb caused partial separation of the epiphysis from the metaphysis, resulting in a valgus deformity. The distraction device was removed three to six weeks after insertion. Spontaneous correction of angulation with growth occurred in the younger sheep; but when the induced valgus angle exceeded 20 degrees correction was poor. In two sheep further distraction was applied on the lateral side and this produced complete correction. Premature closure of epiphyses did not occur after distraction and longitudinal growth of the bone remained normal. In the older sheep asymmetrical distraction succeeded in inducing angulation in only one case, and correction was poor


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 118 - 124
1 May 2024
Macheras GA Argyrou C Tzefronis D Milaras C Tsivelekas K Tsiamtsouris KG Kateros K Papadakis SA

Aims

Accurate diagnosis of chronic periprosthetic joint infection (PJI) presents a significant challenge for hip surgeons. Preoperative diagnosis is not always easy to establish, making the intraoperative decision-making process crucial in deciding between one- and two-stage revision total hip arthroplasty (THA). Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJI. We aimed to evaluate the utility of intraoperative calprotectin lateral flow immunoassay (LFI) in THA patients with suspected chronic PJI.

Methods

The study included 48 THAs in 48 patients with a clinical suspicion of PJI, but who did not meet European Bone and Joint Infection Society (EBJIS) PJI criteria preoperatively, out of 105 patients undergoing revision THA at our institution for possible PJI between November 2020 and December 2022. Intraoperatively, synovial fluid calprotectin was measured with LFI. Cases with calprotectin levels ≥ 50 mg/l were considered infected and treated with two-stage revision THA; in negative cases, one-stage revision was performed. At least five tissue cultures were obtained; the implants removed were sent for sonication.


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 911 - 914
1 Aug 2022
Prijs J Liao Z Ashkani-Esfahani S Olczak J Gordon M Jayakumar P Jutte PC Jaarsma RL IJpma FFA Doornberg JN

Artificial intelligence (AI) is, in essence, the concept of ‘computer thinking’, encompassing methods that train computers to perform and learn from executing certain tasks, called machine learning, and methods to build intricate computer models that both learn and adapt, called complex neural networks. Computer vision is a function of AI by which machine learning and complex neural networks can be applied to enable computers to capture, analyze, and interpret information from clinical images and visual inputs. This annotation summarizes key considerations and future perspectives concerning computer vision, questioning the need for this technology (the ‘why’), the current applications (the ‘what’), and the approach to unlocking its full potential (the ‘how’).

Cite this article: Bone Joint J 2022;104-B(8):911–914.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 421 - 425
1 Mar 2005
Blom AW Cunningham JL Hughes G Lawes TJ Smith N Blunn G Learmonth ID Goodship AE

This study investigates the use of porous biphasic ceramics as graft extenders in impaction grafting of the femur during revision hip surgery. Impaction grafting of the femur was performed in four groups of sheep. Group one received pure allograft, group two 50% allograft and 50% BoneSave, group three 50% allograft and 50% BoneSave type 2 and group four 10% allograft and 90% BoneSave as the graft material. Function was assessed using an index of pre- and post-operative peak vertical ground reaction force ratios. Changes in bone mineral density were measured by dual energy X ray absorptiometry (DEXA) scanning. Loosening and subsidence were assessed radiographically and by histological examination of the explanted specimens. There was no statistically significant difference between the four groups after 18 months of unrestricted functional loading for all outcome measures


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1568 - 1574
1 Nov 2005
Day RE Megson S Wood D

Allograft bone is widely used in orthopaedic surgery, but peri-operative infection of the graft remains a common and disastrous complication. The efficacy of systemic prophylactic antibiotics is unproven, and since the graft is avascular it is likely that levels of antibiotic in the graft are low. Using an electrical potential to accelerate diffusion of antibiotics into allograft bone, high levels were achieved in specimens of both sheep and human allograft. In human bone these ranged from 187.1 mg/kg in endosteal (. sd. 15.7) to 124.6 (. sd. 46.2) in periosteal bone for gentamicin and 31.9 (. sd. 8.9) in endosteal and 2.9 (. sd. 1.1) in periosteal bone for flucloxacillin. The antibiotics remained active against bacteria in vitro after iontophoresis and continued to elute from the allograft for up to two weeks. Structural allograft can be supplemented directly with antibiotics using iontophoresis. The technique is simple and inexpensive and offers a potential means of reducing the rate of peri-operative infection in allograft surgery. Iontophoresis into allograft bone may also be applicable to other therapeutic compounds


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 557 - 564
1 Apr 2009
Rumian AP Draper ERC Wallace AL Goodship AE

An understanding of the remodelling of tendon is crucial for the development of scientific methods of treatment and rehabilitation. This study tested the hypothesis that tendon adapts structurally in response to changes in functional loading. A novel model allowed manipulation of the mechanical environment of the patellar tendon in the presence of normal joint movement via the application of an adjustable external fixator mechanism between the patella and the tibia in sheep, while avoiding exposure of the patellar tendon itself. Stress shielding caused a significant reduction in the structural and material properties of stiffness (79%), ultimate load (69%), energy absorbed (61%), elastic modulus (76%) and ultimate stress (72%) of the tendon compared with controls. Compared with the material properties the structural properties exhibited better recovery after re-stressing with stiffness 97%, ultimate load 92%, energy absorbed 96%, elastic modulus 79% and ultimate stress 80%. The cross-sectional area of the re-stressed tendons was significantly greater than that of stress-shielded tendons. The remodelling phenomena exhibited in this study are consistent with a putative feedback mechanism under strain control. This study provides a basis from which to explore the interactions of tendon remodelling and mechanical environment


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1534 - 1538
1 Nov 2007
Hammer TO Wieling R Green JM Südkamp NP Schneider E Müller CA

This study investigated the quality and quantity of healing of a bone defect following intramedullary reaming undertaken by two fundamentally different systems; conventional, using non-irrigated, multiple passes; or suction/irrigation, using one pass. The result of a measured re-implantation of the product of reaming was examined in one additional group. We used 24 Swiss mountain sheep with a mean tibial medullary canal diameter between 8 mm and 9 mm. An 8 mm ‘napkin ring’ defect was created at the mid-diaphysis. The wound was either surgically closed or occluded. The medullary cavity was then reamed to 11 mm. The Reamer/Irrigator/Aspirator (RIA) System was used for the reaming procedure in groups A (RIA and autofilling) and B (RIA, collected reamings filled up), whereas reaming in group C (Synream and autofilling) was performed with the Synream System. The defect was allowed to auto-fill with reamings in groups A and C, but in group B, the defect was surgically filled with collected reamings. The tibia was then stabilised with a solid locking Unreamed Humerus Nail (UHN), 9.5 mm in diameter. The animals were killed after six weeks. After the implants were removed, measurements were taken to assess the stiffness, strength and callus formation at the site of the defect. There was no significant difference between healing after conventional reaming or suction/irrigation reaming. A significant improvement in the quality of the callus was demonstrated by surgically placing captured reamings into the defect using a graft harvesting system attached to the aspirator device. This was confirmed by biomechanical testing of stiffness and strength. This study suggests it could be beneficial to fill cortical defects with reaming particles in clinical practice, if feasible


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1635 - 1640
1 Dec 2008
Spence G Phillips S Campion C Brooks R Rushton N

Carbonate-substituted hydroxyapatite (CHA) is more osteoconductive and more resorbable than hydroxyapatite (HA), but the underlying mode of its action is unclear. We hypothesised that increased resorption of the ceramic by osteoclasts might subsequently upregulate osteoblasts by a coupling mechanism, and sought to test this in a large animal model. Defects were created in both the lateral femoral condyles of 12 adult sheep. Six were implanted with CHA granules bilaterally, and six with HA. Six of the animals in each group received the bisphosphonate zoledronate (0.05 mg/kg), which inhibits the function of osteoclasts, intra-operatively. After six weeks bony ingrowth was greater in the CHA implants than in HA, but not in the animals given zoledronate. Functional osteoclasts are necessary for the enhanced osteoconduction seen in CHA compared with HA