We evaluated the oncological and functional outcome
of 18 patients, whose malignant bone tumours were excised with the
assistance of navigation, and who were followed up for more than
three years. There were 11 men and seven women, with a mean age
of 31.8 years (10 to 57). There were ten operations on the pelvic
ring and eight joint-preserving limb salvage procedures. The resection
margins were free of tumour in all specimens. The tumours, which
were stage IIB in all patients, included osteosarcoma, high-grade
chondrosarcoma, Ewing’s sarcoma, malignant fibrous histiocytoma
of bone, and adamantinoma. The overall three-year survival rate
of the 18 patients was 88.9% (95% confidence interval (CI) 75.4
to 100). The three-year survival rate of the patients with pelvic malignancy
was 80.0% (95% CI 55.3 to 100), and of the patients with metaphyseal
malignancy was 100%. The event-free survival was 66.7% (95% CI 44.9
to 88.5). Local recurrence occurred in two patients, both of whom
had a pelvic malignancy. The mean Musculoskeletal Tumor Society
functional score was 26.9 points at a mean follow-up of 48.2 months
(22 to 79). We suggest that navigation can be helpful during surgery for
musculoskeletal tumours; it can maximise the accuracy of resection
and minimise the unnecessary sacrifice of normal tissue by providing
precise intra-operative three-dimensional radiological information.
We used a knee-sparing distal femoral endoprosthesis in young patients with malignant bone tumours of the distal femur in whom it was possible to resect the tumour and to preserve the distal femoral condyles. The proximal shaft of the endoprosthesis had a coated hydroxyapatite collar, while the distal end had hydroxyapatite-coated extracortical plates to secure it to the small residual femoral condylar fragment. We reviewed the preliminary results of this endoprosthesis in eight patients with primary bone tumours of the distal femur. Their mean age at surgery was 17.years (14 to 21). The mean follow-up was 24 months (20 to 31). At final follow-up the mean flexion at the knee was 102° (20° to 120°) and the mean Musculoskeletal Tumour Society score was 80% (57% to 96.7%). There was excellent osteointegration at the prosthesis-proximal bone interface with formation of new bone around the hydroxyapatite collar. The prosthesis allowed preservation of the knee and achieved a good functional result. Formation of new bone and remodelling at the interface make the implant more secure. Further follow-up is required to determine the long-term structural integrity of the prosthesis.
Massive endoprostheses using a cemented intramedullary stem are widely used to allow early resumption of activity after surgery for tumours. The survival of the prosthesis varies with the anatomical site, the type of prosthesis and the mode of fixation. Revision surgery is required in many cases because of aseptic loosening. Insertion of a second cemented endoprosthesis may be difficult because of the poor quality of the remaining bone, and loosening recurs quickly. We describe a series of 14 patients with triplate fixation in difficult revision or joint-sparing tumour surgery with a minimum follow-up of four years. The triplate design incorporated well within a remodelled cortex to achieve osseomechanical integration with all patients regaining their original level of function within five months. Our preliminary results suggest that this technique may provide an easy, biomechanically friendly alternative to insertion of a further device with an intramedullary stem, which has a shorter lifespan in revision or joint-sparing tumour surgery. A short segment of bone remaining after resection of a tumour will not accept an intramedullary stem, but may be soundly fixed using this method.