Advertisement for orthosearch.org.uk
Results 1 - 20 of 26
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 284 - 293
1 Mar 2023
Li Y Zhang X Ji B Wulamu W Yushan N Guo X Cao L

Aims

Gram-negative periprosthetic joint infection (PJI) has been poorly studied despite its rapidly increasing incidence. Treatment with one-stage revision using intra-articular (IA) infusion of antibiotics may offer a reasonable alternative with a distinct advantage of providing a means of delivering the drug in high concentrations. Carbapenems are regarded as the last line of defense against severe Gram-negative or polymicrobial infection. This study presents the results of one-stage revision using intra-articular carbapenem infusion for treating Gram-negative PJI, and analyzes the characteristics of bacteria distribution and drug sensitivity.

Methods

We retrospectively reviewed 32 patients (22 hips and 11 knees) who underwent single-stage revision combined with IA carbapenem infusion between November 2013 and March 2020. The IA and intravenous (IV) carbapenem infusions were administered for a single Gram-negative infection, and IV vancomycin combined with IA carbapenems and vancomycin was applied for polymicrobial infection including Gram-negative bacteria. The bacterial community distribution, drug sensitivity, infection control rate, functional recovery, and complications were evaluated. Reinfection or death caused by PJI was regarded as a treatment failure.


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 464 - 471
1 Apr 2022
Veerman K Raessens J Telgt D Smulders K Goosen JHM

Aims

Debridement, antibiotics, and implant retention (DAIR) is a widely accepted form of surgical treatment for patients with an early periprosthetic joint infection (PJI) after primary arthroplasty. The outcome of DAIR after revision arthroplasty, however, has not been reported. The aim of this study was to report the success rate of DAIR after revision arthroplasty with a follow-up of two years.

Methods

This retrospective study, conducted at the Sint Maartenskliniek, Nijmegen, the Netherlands, included 88 patients who underwent DAIR within 90 days of revision total hip or total knee arthroplasty between 2012 and 2019. Details of the surgical procedures and PJI were collected. Univariate analysis and a subgroup analysis of the culture-positive group were performed. Kaplan-Meier survivorship curves were constructed.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 53 - 58
1 Jan 2022
Tai DBG Wengenack NL Patel R Berbari EF Abdel MP Tande AJ

Aims

Fungal and mycobacterial periprosthetic joint infections (PJI) are rare events. Clinicians are wary of missing these diagnoses, often leading to the routine ordering of fungal and mycobacterial cultures on periprosthetic specimens. Our goal was to examine the utility of these cultures and explore a modern bacterial culture technique using bacterial blood culture bottles (BCBs) as an alternative.

Methods

We performed a retrospective review of patients diagnosed with hip or knee PJI between 1 January 2010 and 31 December 2019, at the Mayo Clinic in Rochester, Minnesota, USA. We included patients aged 18 years or older who had fungal, mycobacterial, or both cultures performed together with bacterial cultures. Cases with positive fungal or mycobacterial cultures were reviewed using the electronic medical record to classify the microbiological findings as representing true infection or not.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 39 - 45
1 Jan 2021
Fang X Cai Y Mei J Huang Z Zhang C Yang B Li W Zhang W

Aims

Metagenomic next-generation sequencing (mNGS) is useful in the diagnosis of infectious disease. However, while it is highly sensitive at identifying bacteria, it does not provide information on the sensitivity of the organisms to antibiotics. The purpose of this study was to determine whether the results of mNGS can be used to guide optimization of culture methods to improve the sensitivity of culture from intraoperative samples.

Methods

Between July 2014 and October 2019, patients with suspected joint infection (JI) from whom synovial fluid (SF) was obtained preoperatively were enrolled. Preoperative aspirated SF was analyzed by conventional microbial culture and mNGS. In addition to samples taken for conventional microbial culture, some samples were taken for intraoperative culture to optimize the culture method according to the preoperative mNGS results. The demographic characteristics, medical history, laboratory examination, mNGS, and culture results of the patients were recorded, and the possibility of the optimized culture methods improving diagnostic efficiency was evaluated.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 522 - 529
1 Mar 2021
Nichol T Callaghan J Townsend R Stockley I Hatton PV Le Maitre C Smith TJ Akid R

Aims

The aim of this study was to develop a single-layer hybrid organic-inorganic sol-gel coating that is capable of a controlled antibiotic release for cementless hydroxyapatite (HA)-coated titanium orthopaedic prostheses.

Methods

Coatings containing gentamicin at a concentration of 1.25% weight/volume (wt/vol), similar to that found in commercially available antibiotic-loaded bone cement, were prepared and tested in the laboratory for: kinetics of antibiotic release; activity against planktonic and biofilm bacterial cultures; biocompatibility with cultured mammalian cells; and physical bonding to the material (n = 3 in all tests). The sol-gel coatings and controls were then tested in vivo in a small animal healing model (four materials tested; n = 6 per material), and applied to the surface of commercially pure HA-coated titanium rods.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 908 - 915
1 May 2021
O’Donnell JA Wu M Cochrane NH Belay E Myntti MF James GA Ryan SP Seyler TM

Aims

Periprosthetic joint infections (PJIs) are among the most devastating complications after joint arthroplasty. There is limited evidence on the efficacy of different antiseptic solutions on reducing biofilm burden. The purpose of the present study was to test the efficacy of different antiseptic solutions against clinically relevant microorganisms in biofilm.

Methods

We conducted an in vitro study examining the efficacy of several antiseptic solutions against clinically relevant microorganisms. We tested antiseptic irrigants against nascent (four-hour) and mature (three-day) single-species biofilm created in vitro using a drip-flow reactor model.


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1341 - 1348
3 Oct 2020
Scholten R Hannink G Willemsen K Mascini EM Somford MP Schreurs BW van Susante JLC

Aims

Preoperative nasal Staphylococcus aureus screening and eradication reduces surgical site infections (SSIs) but its impact on reducing early prosthetic joint infection (PJI) remains controversial. This study aims to assess the effect of preoperative nasal S. aureus screening and eradication on the incidence of early PJI in general and S. aureus-induced early PJI.

Methods

All primary total hip arthroplasties (THA) and total knee arthroplasties (TKA) performed from January 2006 to April 2018 were retrospectively reviewed for the incidence of early PJI. Demographic parameters, risk factors for PJI (American Society of Anaesthesiologists classification, body mass index, smoking status, and diabetes mellitus) and implant types were collected. A preoperative screening and eradication protocol for nasal colonization of S. aureus was introduced in October 2010. The incidence of early PJI was compared before and after the implementation of the protocol. Missing data were imputed via multiple imputation by chained equations. Inverse probability weighting was used to account for differences between patients in both groups. Weighted univariate logistic regression was used to evaluate the incidence of early PJI for both groups.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 329 - 335
1 Mar 2020
Fink B Schuster P Braun R Tagtalianidou E Schlumberger M

Aims

Biopsy of the periprosthetic tissue is an important diagnostic tool for prosthetic joint infection (PJI) as it enables the detection of the responsible microorganism with its sensitivity to antibiotics. We aimed to investigate how often the bacteria identified in the tissue analysis differed between samples obtained from preoperative biopsy and intraoperative revision surgery in cases of late PJI; and whether there was a therapeutic consequence.

Methods

A total of 508 patients who required revision surgery of total hip arthroplasty (THA) (n = 231) or total knee arthroplasty (TKA) (n = 277) because of component loosening underwent biopsy before revision surgery. The tissue samples collected at biopsy and during revision surgery were analyzed according to the criteria of the Musculoskeletal Infection Society (MSIS).


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1256 - 1258
1 Sep 2005
Al-Maiyah M Hill D Bajwa A Slater S Patil P Port A Gregg PJ

We have investigated the contaminating bacteria in primary hip arthroplasty and their sensitivity to the prophylactic antibiotics currently in use. Impressions (627) of the gloved hands of the surgical team in 50 total hip arthroplasties were obtained on blood agar. The gloves were changed after draping, at intervals of 20 minutes thereafter, and before using cement. Changes were also undertaken whenever a visible puncture was detected. The culture plates were incubated at 37°C for 48 hours. Isolates were identified and tested for sensitivity to flucloxacillin, which is a recognised indicator of sensitivity to cefuroxime. They were also tested against other agents depending upon their appearance on Gram staining. We found contamination in 57 (9%) impressions and 106 bacterial isolates. Coagulase-negative staphylococci were seen most frequently (68.9%), but we also isolated Micrococcus (12.3%), diphtheroids (9.4%), Staphylococcus aureus (6.6%) and Escherichia coli (0.9%). Of the coagulase-negative staphylococci, only 52.1% were sensitive to flucloxacillin and therefore to cefuroxime. We believe that it is now appropriate to review the relevance of prophylaxis with cefuroxime and to consider the use of other agents


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1345 - 1351
1 Oct 2018
Kuo F Lu Y Wu C You H Lee G Lee MS

Aims

The aim of this study was to compare the results of 16S/28S rRNA sequencing with the erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, and synovial fluid analysis in the diagnosis of prosthetic joint infection (PJI).

Patients and Methods

Between September 2015 and August 2016, 214 consecutive patients were enrolled. In the study population, there were 25 patients with a PJI and 189 controls. Of the PJI patients, 14 (56%) were women, and the mean age at the time of diagnosis was 65 years (38 to 83). The ESR and CRP levels were measured, and synovial fluid specimens were collected prospectively. Synovial fluid was subjected to reverse transcription polymerase chain reaction (RT-PCR)/sequence analysis targeting the 16S/28S rRNA, and to conventional culture. Laboratory personnel who were blind to the clinical information performed all tests. The diagnosis of PJI was based on the criteria of the Musculoskeletal Infection Society.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 103 - 107
1 Jan 2000
Pekkarinen J Alho A Lepistö J Ylikoski M Ylinen P Paavilainen T

We have reviewed retrospectively 68 revisions of the femoral component in arthroplasties of the hip in 65 patients, using impaction bone grafting, at a median of three years (1 month to 6 years). We employed the cemented Exeter X-Change technique in 36 patients and the uncemented Bi-Metric allografting method in 32. The 37 bone defects were grade 3 or grade 4 on the Endo-Klinik classification. The Mayo hip score improved from a mean of 32 (. sd. ± 18) to 62 (. sd. ± 15). Most (25) of the 34 complications occurred in grade-3 and grade-4 defects; nine were intraoperative diaphyseal fractures and eight fractures of the greater trochanter. All the fractures united. The risk of intraoperative fracture was prevented by supporting the bone with wires in 16 hips, with reinforcement mesh in 18 and by a plate in six. Early migration of the stem of more than 10 mm during the first year indicated rotational instability; it occurred in three cases. In difficult revision cases with large defects of the femoral bone, bone-impaction techniques carry a high risk of complications


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 749 - 754
1 Jun 2018
Partridge DG Winnard C Townsend R Cooper R Stockley I

Aims

The aim of this study was to establish the diagnostic accuracy of culture of joint aspirate with and without saline injection-reaspiration.

Patients and Methods

This is a retrospective analysis of 580 hip and knee aspirations in patients who were deemed to have a moderate to high risk of infection, and who subsequently proceeded to revision arthroplasty over a period of 12 years. It was carried out at a large quaternary referral centre where preoperative aspiration is routine.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1482 - 1489
1 Nov 2017
Jacobs AME Bénard M Meis JF van Hellemondt G Goosen JHM

Aims

Positive cultures are not uncommon in cases of revision total knee and hip arthroplasty (TKA and THA) for presumed aseptic causes. The purpose of this study was to assess the incidence of positive intra-operative cultures in presumed aseptic revision of TKA and THA, and to determine whether the presence of intra-operative positive cultures results in inferior survival in such cases.

Patients and Methods

A retrospective cohort study was assembled with 679 patients undergoing revision knee (340 cases) or hip arthroplasty (339 cases) for presumed aseptic causes. For all patients three or more separate intra-operative cultures were obtained. Patients were diagnosed with a previously unsuspected prosthetic joint infection (PJI) if two or more cultures were positive with the same organism. Records were reviewed for demographic details, pre-operative laboratory results and culture results. The primary outcome measure was infection-free implant survival at two years.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 66 - 72
1 Jan 2017
Sigmund IK Holinka J Gamper J Staats K Böhler C Kubista B Windhager R

Aims

The diagnosis of periprosthetic joint infection (PJI) remains demanding due to limitations of all the available diagnostic tests. The synovial fluid marker, α-defensin, is a promising adjunct for the assessment of potential PJI. The purpose of this study was to investigate the qualitative assessment of α-defensin, using Synovasure to detect or exclude periprosthetic infection in total joint arthroplasty.

Patients and Methods

We studied 50 patients (28 women, 22 men, mean age 65 years; 20 to 89) with a clinical indication for revision arthroplasty who met the inclusion criteria of this prospective diagnostic study. The presence of α-defensin was determined using the qualitative Synovasure test and compared with standard diagnostic methods for PJI. Based on modified Musculoskeletal Infection Society (MSIS) criteria, 13 cases were categorised as septic and 36 as aseptic revisions. One test was inconclusive.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 917 - 920
1 Jul 2017
Bloch BV Shah A Snape SE Boswell TCJ James PJ

Aims

Infection following total hip or knee arthroplasty is a serious complication. We noted an increase in post-operative infection in cases carried out in temporary operating theatres. We therefore compared those cases performed in standard and temporary operating theatres and examined the deep periprosthetic infection rates.

Patients and methods

A total of 1223 primary hip and knee arthroplasties were performed between August 2012 and June 2013. A total of 539 (44%) were performed in temporary theatres. The two groups were matched for age, gender, body mass index and American Society of Anesthesiologists grade.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 73 - 77
1 Jan 2017
Frew NM Cannon T Nichol T Smith TJ Stockley I

Aims

Vancomycin is commonly added to acrylic bone cement during revision arthroplasty surgery. Proprietary cement preparations containing vancomycin are available, but are significantly more expensive. We investigated whether the elution of antibiotic from ‘home-made’ cement containing vancomycin was comparable with more expensive commercially available vancomycin impregnated cement.

Materials and Methods

A total of 18 cement discs containing either proprietary CopalG+V; or ‘home-made’ CopalR+G with vancomycin added by hand, were made. Each disc contained the same amount of antibiotic (0.5 g gentamycin, 2 g vancomycin) and was immersed in ammonium acetate buffer in a sealed container. Fluid from each container was sampled at eight time points over a two-week period. The concentrations of gentamicin and vancomycin in the fluid were analysed using high performance liquid chromatography mass spectrometry.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1062 - 1068
1 Aug 2016
Singh G Deutloff N Maertens N Meyer H Awiszus F Feuerstein B Roessner A Lohmann CH

Aims

Tissue responses to debris formed by abrasion of polymethylmethacrylate (PMMA) spacers at two-stage revision arthroplasty for prosthetic joint infection are not well described. We hypothesised that PMMA debris induces immunomodulation in periprosthetic tissues.

Patients and Methods

Samples of tissue were taken during 35 two-stage revision arthroplasties (nine total hip and 26 total knee arthroplasties) in patients whose mean age was 67 years (44 to 85). Fourier transform infrared microscopy was used to confirm the presence of PMMA particles. Histomorphometry was performed using Sudan Red and Haematoxylin-Eosin staining. CD-68, CD-20, CD-11(c), CD-3 and IL-17 antibodies were used to immunophenotype the inflammatory cells. All slides were scored semi-quantitatively using the modified Willert scoring system.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1519 - 1524
1 Nov 2015
Salih S Paskins A Nichol T Smith T Hamer A

We investigated whether the indentation of bone cement spacers used in revision of infected joint arthroplasty with a MacDonald dissector increased the elution of antibiotic in vitro. A total of 24 cement discs containing either 0.17 g (0.88% w/w), 0.25 g (1.41% w/w), or 0.33 g (1.75% w/w) gentamicin of constant size were made. Of these, 12 were indented with the dissector. Each disc was immersed in ammonium acetate buffer in a sealed container, and fluid from each container was sampled at zero, one, three, six, 24, 48 and 72 hours and at one, and two weeks. The concentration of gentamicin in the fluid was analysed using high performance liquid chromatography mass spectrometry.

The fluid sampled at 72 hours from the indented discs containing 0.17 g gentamicin (0.88% w/w) contained a mean of 113 mcg/ml (90.12 to 143.5) compared with 44.5 mcg/ml (44.02 to 44.90) in the fluid sampled from the plain discs (p = 0.012). In discs containing 0.33 g gentamicin (1.75% w/w), the concentration eluted from the indented discs at 72 hours was a mean of 316 mcg/ml (223 to 421) compared with a mean of 118 mcg/ml (100 to 140) from the plain discs (p < 0.001).

At two weeks, these significant differences persisted. At nine weeks the indented discs eluted a greater concentration for all gentamicin doses, but the difference was only significant for the discs containing 0.17 g (0.88% w/w, p = 0.006). However if the area under the curve is taken as a measure of the total antibiotic eluted, the indented discs eluted more gentamicin than the plain discs for the 0.17 g (0.88% w/w, p = 0.031), the 0.25 g (1.41% w/w, p < 0.001) and the 0.33 g (1.75% w/w, p < 0.001) discs.

When preparing antibiotic spacers for use in staged revision arthroplasty surgery we recommend indenting the spacer with a MacDonald dissector to increase the elution of antibiotic.

Cite this article: Bone Joint J 2015;97-B:1519–24.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 678 - 682
1 May 2013
Holinka J Pilz M Kubista B Presterl E Windhager R

The aim of this study was to evaluate whether coating titanium discs with selenium in the form of sodium selenite decreased bacterial adhesion of Staphylococcus aureus and Staph. epidermidis and impeded osteoblastic cell growth.

In order to evaluate bacterial adhesion, sterile titanium discs were coated with increasing concentrations of selenium and incubated with bacterial solutions of Staph. aureus (ATCC 29213) and Staph. epidermidis (DSM 3269) and stained with Safranin-O. The effect of selenium on osteoblastic cell growth was also observed. The adherence of MG-63 cells on the coated discs was detected by staining with Safranin-O. The proportion of covered area was calculated with imaging software.

The tested Staph. aureus strain showed a significantly reduced attachment on titanium discs with 0.5% (p = 0.011) and 0.2% (p = 0.02) selenium coating. Our test strain from Staph. epidermidis showed a highly significant reduction in bacterial adherence on discs coated with 0.5% (p = 0.0099) and 0.2% (p = 0.002) selenium solution. There was no inhibitory effect of the selenium coating on the osteoblastic cell growth.

Selenium coating is a promising method to reduce bacterial attachment on prosthetic material.

Cite this article: Bone Joint J 2013;95-B:678–82.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 6 | Pages 824 - 827
1 Jun 2011
Wanner S Gstöttner M Meirer R Hausdorfer J Fille M Stöckl B

Biofilm-associated infections in wounds or on implants are difficult to treat. Eradication of the bacteria is nearly always impossible, despite the use of specific antibiotics. The bactericidal effects of high-energy extracorporeal shock waves on Staphylococcus aureus have been reported, but the effect of low-energy shock waves on staphylococci and staphylococcal biofilms has not been investigated. In this study, biofilms grown on stainless steel washers were examined by electron microscopy. We tested ten experimental groups with Staph. aureus-coated washers and eight groups with Staph. epidermidis.

The biofilm-cultured washers were exposed to low-energy shock waves at 0.16 mJ/mm2 for 500 impulses. The washers were then treated with cefuroxime, rifampicin and fosfomycin, both alone and in combination. All tests were carried out in triplicate. Viable cells were counted to determine the bactericidal effect.

The control groups of Staph. aureus and Staph. epidermidis revealed a cell count of 6 × 108 colony-forming units/ml. Complete eradication was achieved using the combination of antibiotic therapy (single antibiotic in Staph. aureus, a combination in Staph. epidermidis) and shock wave application (p < 0.01).

We conclude that shock waves combined with antibiotics could be tested in an in vitro model of infection.