The aim of this study was to longitudinally compare the clinical and radiological outcomes of anatomical total shoulder arthroplasty (aTSA) up to long-term follow-up, when using cemented keel, cemented peg, and hybrid cage peg glenoid components and the same humeral system. We retrospectively analyzed a multicentre, international clinical database of a single platform shoulder system to compare the short-, mid-, and long-term clinical outcomes associated with three designs of aTSA glenoid components: 294 cemented keel, 527 cemented peg, and 981 hybrid cage glenoids. Outcomes were evaluated at 4,746 postoperative timepoints for 1,802 primary aTSA, with a mean follow-up of 65 months (24 to 217).Aims
Methods
In this study we evaluated whether the Instability
Severity Index Score (ISIS) and the Western Ontario Shoulder Instability
Index (WOSI) could detect those patients at risk of failure following
arthroscopic Bankart repair. Between April 2008 and June 2010, the
ISIS and WOSI were recorded pre-operatively in 110 patients (87
male, 79%) with a mean age of 25.1 years (16 to 61) who underwent
this procedure for recurrent anterior glenohumeral instability. A telephone interview was performed two-years post-operatively
to determine whether patients had experienced a recurrent dislocation
and whether they had returned to pre-injury activity levels. In
all, six (5%) patients had an ISIS >
6 points (0 to 9). Of 100 (91%)
patients available two years post-operatively, six (6%) had a recurrent dislocation,
and 28 (28%) did not return to pre-injury activity. No patient who
dislocated had an ISIS >
6 (p = 1.0). There was no difference in
the mean pre-operative WOSI in those who had a re-dislocation and
those who did not (p = 0.99). The pre-operative WOSI was significantly
lower (p = 0.02) in those who did not return to pre-injury activity, whereas
the ISIS was not associated with return to pre-injury activity (p
= 0.13). In conclusion, neither the pre-operative ISIS nor WOSI predicted
recurrent dislocation within two years of arthroscopic Bankart repair.
Patients with a lower pre-operative WOSI were less likely to return
to pre-injury activity. Cite this article:
We report our experience with glenohumeral arthrodesis
as a salvage procedure for epilepsy-related recurrent shoulder instability.
A total of six patients with epilepsy underwent shoulder fusion
for recurrent instability and were followed up for a mean of 39 months
(12 to 79). The mean age at the time of surgery was 31 years (22
to 38). Arthrodesis was performed after a mean of four previous
stabilisation attempts (0 to 11) in all but one patient in whom
the procedure was used as a primary treatment. All patients achieved
bony union, with a mean time to fusion of 2.8 months (2 to 7). There
were no cases of re-dislocation. One revision was undertaken for
loosening of the metalwork, and then healed satisfactorily. An increase
was noted in the mean subjective shoulder value, which improved
from 37 (5 to 50) pre-operatively to 42 (20 to 70) post-operatively
although it decreased in two patients. The mean Oxford shoulder
instability score improved from 13 pre-operatively (7 to 21) to
24 post-operatively (13 to 36). In our series, glenohumeral arthrodesis
eliminated recurrent instability and improved functional outcome. Fusion
surgery should therefore be considered in this patient population.
However, since the majority of patients are young and active, they
should be comprehensively counselled pre-operatively given the functional
deficit that results from the procedure. Cite this article:
Medium-term results of the Discovery elbow replacement
are presented. We reviewed 51 consecutive primary Discovery total
elbow replacements (TERs) implanted in 48 patients. The mean age
of the patients was 69.2 years (49 to 92), there were 19 males and
32 females (37%:63%) The mean follow-up was 40.6 months (24 to 69).
A total of six patients were lost to follow-up. Statistically significant
improvements in range movement and Oxford Elbow Score were found
(p <
0.001). Radiolucent lines were much more common in, and
aseptic loosening was exclusive to, the humeral component. Kaplan–Meier
survivorship at five years was 92.2% (95% CI 74.5% to 96.4%) for
aseptic loosening. In four TERs, periprosthetic infection occurred
resulting in failure. A statistically significant association between
infection and increased BMI was found (p = 0.0268). Triceps failure
was more frequent after the Mayo surgical approach and TER performed
after previous trauma surgery. No failures of the implant were noted. Our comparison shows that the Discovery has early clinical results
that are similar to other semi-constrained TERs. We found continued
radiological surveillance with particular focus on humeral lucency
is warranted and has not previously been reported. Despite advances
in the design of total elbow replacement prostheses, rates of complication
remain high. Cite this article: