In approximately 20% of patients with ankle fractures, there
is an concomitant injury to the syndesmosis which requires stabilisation,
usually with one or more syndesmotic screws. The aim of this review
is to evaluate whether removal of the syndesmotic screw is required
in order for the patient to obtain optimal functional recovery. A literature search was conducted in Medline, Embase and the
Cochrane Library for articles in which the syndesmotic screw was
retained. Articles describing both removal and retaining of syndesmotic
screws were included. Excluded were biomechanical studies, studies
not providing patient related outcome measures, case reports, studies
on skeletally immature patients and reviews. No restrictions regarding
year of publication and language were applied.Aims
Materials and Methods
Aims. This study aimed to compare the outcomes of two different postoperative management approaches following
Aims. Patients with diabetes are at increased risk of wound complications
after open reduction and internal fixation of unstable ankle fractures.
A fibular nail avoids large surgical incisions and allows anatomical
reduction of the mortise. Patients and Methods. We retrospectively reviewed the results of fluoroscopy-guided
reduction and percutaneous fibular nail fixation for unstable Weber
type B or C fractures in 24 adult patients with type 1 or type 2
diabetes. The re-operation rate for wound dehiscence or other indications
such as amputation, mortality and functional outcomes was determined. Results. Two patients developed lateral side wound infection, one of whom
underwent wound debridement. Three other patients required re-operation
for removal of symptomatic hardware. No patient required a below-knee
amputation. Six patients died during the study period for unrelated
reasons. At a median follow-up of 12 months (7 to 38) the mean Short Form-36
Mental Component Score and Physical Component Score were 53.2 (95% confidence
intervals (CI) 48.1 to 58.4) and 39.3 (95% CI 32.1 to 46.4), respectively.
The mean Visual Analogue Score for pain was 3.1 (95% 1.4 to 4.9).
The mean Ankle Osteoarthritis Scale total score was 32.9 (95% CI
16.0 to 49.7). Conclusion. Fluoroscopy-guided reduction and fibular nail fixation of unstable
ankle fractures in patients with diabetes was associated with a
low incidence of wound and overall complications, while providing
effective
The aim of this study was to investigate whether on-demand removal (ODR) is noninferior to routine removal (RR) of syndesmotic screws regarding functional outcome. Adult patients (aged above 17 years) with traumatic syndesmotic injury, surgically treated within 14 days of trauma using one or two syndesmotic screws, were eligible (n = 490) for inclusion in this randomized controlled noninferiority trial. A total of 197 patients were randomized for either ODR (retaining the syndesmotic screw unless there were complaints warranting removal) or RR (screw removed at eight to 12 weeks after syndesmotic fixation), of whom 152 completed the study. The primary outcome was functional outcome at 12 months after screw placement, measured by the Olerud-Molander Ankle Score (OMAS).Aims
Methods
The aim of this study was to evaluate the functional outcome in patients undergoing implant removal (IR) after fracture fixation below the level of the knee. All adult patients (18 to 75 years) undergoing IR after fracture fixation below the level of the knee between November 2014 and September 2016 were included as part of the WIFI (Wound Infections Following Implant Removal Below the Knee) trial, performed in 17 teaching hospitals and two university hospitals in The Netherlands. In this multicentre prospective cohort, the primary outcome was the difference in functional status before and after IR, measured by the Lower Extremity Functional Scale (LEFS), with a minimal clinically important difference of nine points.Aims
Patients and Methods
Total ankle arthroplasty (TAA) surgery is complex and attracts a wide variety of complications. The literature lacks consistency in reporting adverse events and complications. The aim of this article is to provide a comprehensive analysis of each of these complications from a literature review, and to compare them with rates from our Unit, to aid clinicians with the process of informed consent. A total of 278 consecutive total ankle arthroplasties (251 patients), performed by four surgeons over a six-year period in Wrightington Hospital (Wigan, United Kingdom) were prospectively reviewed. There were 143 men and 108 women with a mean age of 64 years (41 to 86). The data were recorded on each follow-up visit. Any complications either during initial hospital stay or subsequently reported on follow-ups were recorded, investigated, monitored, and treated as warranted. Literature search included the studies reporting the outcomes and complications of TAA implants.Aims
Patients and Methods
Injuries to the foot in athletes are often subtle
and can lead to a substantial loss of function if not diagnosed
and treated appropriately. For these injuries in general, even after
a diagnosis is made, treatment options are controversial and become
even more so in high level athletes where limiting the time away
from training and competition is a significant consideration. In this review, we cover some of the common and important sporting
injuries affecting the foot including updates on their management
and outcomes. Cite this article:
Open reduction and internal fixation of high-energy pilon fractures are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. A total of 17 consecutive patients with pilon fractures of AO/OTA type 43-B3 (n = 1), type C2 (n = 12) and type C3 (n = 4) were treated by indirect reduction by capsuloligamentotaxis and stabilisation using an ankle-spanning Ilizarov fixator. The calcaneal ring was removed at a mean of 3.7 weeks (3 to 6). A total of 16 patients were available for follow-up at a mean of 29 months (23 to 43). The mean time to healing was 15.8 weeks (13 to 23). Nine patients had pin-track infections but none had deep infection or osteomyelitis. Four patients (25%) had malunion. Fair, good or excellent ankle scores were found in 14 patients. External fixation with a ring fixator achieves stable reduction of the fractured fragments without additional trauma to soft tissues. With minimum complications and good healing results, the Ilizarov apparatus is particularly useful for high-energy pilon fractures.