Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 254 - 258
1 Feb 2013
Park S Noh H Kam M

We analysed retrospectively the risk factors leading to femoral overgrowth after flexible intramedullary nailing in 43 children (mean age 7.1 years (3.6 to 12.0)) with fractures of the shaft of the femur. We reviewed their demographic data, mechanism of injury, associated injuries, the type and location of the fractures, the nail–canal diameter (NCD) ratios and femoral overgrowth at a mean follow-up of 40.7 months (25.2 to 92.7). At that time, the children were divided into two groups, those with femoral overgrowth of < 1 cm (Group 1), and those with overgrowth of ≥ 1 cm (Group 2). The mean femoral overgrowth of all patients was 0.6 cm at final follow-up. Overgrowth of ≥ 1 cm was noted in 11 children (25.6%). The NCD ratio was significantly lower in Group 2 than in Group 1, with an odds ratio of 30.0 (p = 0.003). We believe that a low NCD ratio is an indicator of an unstable configuration with flexible intramedullary nailing, and have identified an association between a low NCD ratio and femoral overgrowth resulting in leg-length discrepancy after flexible intramedullary nailing in paediatric femoral shaft fractures. Cite this article: Bone Joint J 2013;95-B:254–8


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1056 - 1061
1 Aug 2020
Gordon JE Anderson JT Schoenecker PL Dobbs MB Luhmann SJ Hoernschemeyer DG

Aims

Current American Academy of Orthopaedic Surgeons (AAOS) guidelines for treating femoral fractures in children aged two to six years recommend early spica casting although some individuals have recommended intramedullary stabilization in this age group. The purpose of this study was to compare the treatment and family burden of care of spica casting and flexible intramedullary nailing in this age group.

Methods

Patients aged two to six years old with acute, non-pathological femur fractures were prospectively enrolled at one of three tertiary children’s hospitals. Either early closed reduction with spica cast application or flexible intramedullary nailing was accomplished under general anaesthesia. The treatment method was selected after discussion of the options by the surgeon with the family. Data were prospectively collected on patient demographics, fracture characteristics, complications, pain medication, and union. The Impact on Family Scale was obtained at the six-week follow-up visit. In all, 75 patients were included in the study: 39 in the spica group and 36 in the nailing group. The mean age of the spica group was 2.71 (2.0 to 6.9) years and the mean age of the nailing group was 3.16 (2.0 to 6.9) years.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 491 - 496
1 Apr 2019
Li NY Kalagara S Hersey A Eltorai AEM Daniels AH Cruz Jr AI

Aims

The aim of this study was to utilize a national paediatric inpatient database to determine whether obesity influences the operative management and inpatient outcomes of paediatric limb fractures.

Patients and Methods

The Kids’ Inpatient Database (KID) was used to evaluate children between birth and 17 years of age, from 1997 and 2012, who had undergone open and closed treatment of humeral, radial and ulna, femoral, tibial, and ankle fractures. Demographics, hospital charges, lengths of stay (LOS), and complications were analyzed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 713 - 718
1 May 2012
Kaiser MM Zachert G Wendlandt R Eggert R Stratmann C Gros N Schulze-Hessing M Rapp M

Elastic stable intramedullary nailing (ESIN) is generally acknowledged to be the treatment of choice for displaced diaphyseal femoral fractures in children over the age of three years, although complication rates of up to 50% are described. Pre-bending the nails is recommended, but there are no published data to support this. Using synthetic bones and a standardised simulated fracture, we performed biomechanical testing to determine the influence on the stability of the fracture of pre-bending the nails before implantation. Standard ESIN was performed on 24 synthetic femoral models with a spiral fracture. In eight cases the nails were inserted without any pre-bending, in a further eight cases they were pre-bent to 30° and in the last group of eight cases they were pre-bent to 60°. Mechanical testing revealed that pre-bending to 60° produced a significant increase in the stiffness or stability of the fracture. Pre-bending to 60° showed a significant positive influence on the stiffness compared with unbent nails. Pre-bending to 30° improved stiffness only slightly.

These findings validate the recommendations for pre-bending, but the degree of pre-bend should exceed 30°. Adopting higher degrees of pre-bending should improve stability in spiral fractures and reduce the complications of varus deformity and shortening.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 558 - 563
1 Apr 2015
Windolf M Fischer MF Popp AW Matthys R Schwieger K Gueorguiev B Hunter JB Slongo TF

End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure.

Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°.

In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007).

These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push–out can be effectively reduced by the use of end caps.

Cite this article: Bone Joint J 2015;97-B:558–63.