Advertisement for orthosearch.org.uk
Results 1 - 20 of 28
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 76 - 81
1 Jan 2005
Pajarinen J Lindahl J Michelsson O Savolainen V Hirvensalo E

We treated 108 patients with a pertrochanteric femoral fracture using either the dynamic hip screw or the proximal femoral nail in this prospective, randomised series. We compared walking ability before fracture, intra-operative variables and return to their residence. Patients treated with the proximal femoral nail (n = 42) had regained their pre-operative walking ability significantly (p = 0.04) more often by the four-month review than those treated with the dynamic hip screw (n = 41). Peri-operative or immediate post-operative measures of outcome did not differ between the groups, with the exception of operation time. The dynamic hip screw allowed a significantly greater compression of the fracture during the four-month follow-up, but consolidation of the fracture was comparable between the two groups. Two major losses of reduction were observed in each group, resulting in a total of four revision operations. Our results suggest that the use of the proximal femoral nail may allow a faster postoperative restoration of walking ability, when compared with the dynamic hip screw


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 652 - 654
1 Jul 2000
Tornetta P Tiburzi D

Retrograde femoral nailing is gaining in popularity. We report a prospective, randomised comparison of antegrade and retrograde procedures in 68 patients with 69 fractures of the femoral shaft. All nails were inserted after appropriate reaming. There was no difference in operating time, blood loss, technical complications, size of nail or reamer, or transfusion requirements. There were more problems of length and rotation using a retrograde technique on a radiolucent table than with an antegrade approach on a fracture table. All fractures in both groups healed and there was no difference in the time taken to achieve union. Although retrograde nailing is a promising technique the skills required need practice. A longer period of follow-up is necessary to determine whether there are long-term problems in the knee after such surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 485 - 489
1 May 1998
Clatworthy MG Clark DI Gray DH Hardy AE

We performed a randomised, prospective trial to evaluate the use of unreamed titanium nails for femoral fractures. Of 48 patients with 50 femoral fractures 45 were followed to union; 23 with an unreamed and 22 with a reamed nail. The study was stopped early because of a high rate of implant failure.

The fractures in the unreamed group were slower to unite (39.4 weeks) than those in the reamed group (28.5 weeks; p = 0.007). The time to union was over nine months in 57% of the unreamed group and in 18% of the reamed group.

In the unreamed group 14 secondary procedures were required in ten patients to enhance healing compared with three in three patients in the reamed group. Six implants (13%) failed, three in each group. Four of these six fractures showed evidence of delayed union.

To achieve quicker union and fewer implant failures we recommend the use of reamed nails of at least 12 mm in diameter for female patients and 13 mm in males.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 114 - 121
1 Jan 2014
Pekmezci M McDonald E Buckley J Kandemir U

We investigated a new intramedullary locking nail that allows the distal interlocking screws to be locked to the nail. We compared fixation using this new implant with fixation using either a conventional nail or a locking plate in a laboratory simulation of an osteoporotic fracture of the distal femur. A total of 15 human cadaver femora were used to simulate an AO 33-A3 fracture pattern. Paired specimens compared fixation using either a locking or non-locking retrograde nail, and using either a locking retrograde nail or a locking plate. The constructs underwent cyclical loading to simulate single-leg stance up to 125 000 cycles. Axial and torsional stiffness and displacement, cycles to failure and modes of failure were recorded for each specimen. When compared with locking plate constructs, locking nail constructs had significantly longer mean fatigue life (75 800 cycles (. sd. 33 900) vs 12 800 cycles (. sd. 6100); p = 0.007) and mean axial stiffness (220 N/mm (. sd. 80) vs 70 N/mm (. sd. 18); p = 0.005), but lower mean torsional stiffness (2.5 Nm/° (. sd. 0.9) vs 5.1 Nm/° (. sd. 1.5); p = 0.008). In addition, in the nail group the mode of failure was either cut-out of the distal screws or breakage of nails, and in the locking plate group breakage of the plate was always the mode of failure. Locking nail constructs had significantly longer mean fatigue life than non-locking nail constructs (78 900 cycles (. sd. 25 600) vs 52 400 cycles (. sd. 22 500); p = 0.04). The new locking retrograde femoral nail showed better stiffness and fatigue life than locking plates, and superior fatigue life to non-locking nails, which may be advantageous in elderly patients. Cite this article: Bone Joint J 2014;96-B:114–21


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 449 - 454
15 Mar 2023
Zhang C Wang C Duan N Zhou D Ma T

Aims

The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN).

Methods

The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 4 - 8
1 Jan 1997
Krettek C Miclau T Blauth M Lindsey RW Donow C Tscherne H

Rotational deformity following intramedullary nailing may cause symptoms and require surgical correction by osteotomy. Reamed, locked intramedullary nailing may be performed, but concern about cortical blood supply and potential pulmonary dysfunction from reaming have led many surgeons to limit this and use smaller diameter nails. Slotted nails are commonly used but are less stiff in torsion than the newer unslotted nails, particularly at the lower diameters. We report two cased of recurrent femoral rotational deformity after using statically interlocked slotted intramedullary nails to correct existing femoral rotational deformities. These patients show that small diameter statically interlocked femoral nails with diminished bone-nail contact must be stiff enough in rotation to avoid potential recurrence


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 86 - 94
1 Jan 2004
Schipper IB Steyerberg EW Castelein RM van der Heijden FHWM den Hoed PT Kerver AJH van Vugt AB

The proximal femoral nail (PFN) is a recently introduced intramedullary system, designed to improve treatment of unstable trochanteric fractures of the hip. In a multicentre prospective clinical study, the intra-operative use, complications and outcome of treatment using the PFN (n = 211) were compared with those using the gamma nail (GN) (n = 213). The intra-operative blood loss was lower with the PFN (220 ml v 287 ml, p = 0.001). Post-operatively, more lateral protrusion of the hip screws of the PFN (7.6%) was documented, compared with the gamma nail (1.6%, p = 0.02). Most local complications were related to suboptimal reduction of the fracture and/or positioning of the implant. Functional outcome and consolidation were equal for both implants. Generally, the results of treatment of unstable trochanteric fractures were comparable for the PFN and GN. The pitfalls and complications were similar, and mainly surgeon- or fracture-related, rather than implant-related


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 775 - 781
1 Apr 2021
Mellema JJ Janssen S Schouten T Haverkamp D van den Bekerom MPJ Ring D Doornberg JN

Aims

This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)).

Methods

A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 442 - 448
1 Mar 2021
Nikolaou VS Masouros P Floros T Chronopoulos E Skertsou M Babis GC

Aims

The aim of this study was to investigate the hypothesis that a single dose of tranexamic acid (TXA) would reduce blood loss and transfusion rates in elderly patients undergoing surgery for a subcapital or intertrochanteric (IT) fracture of the hip.

Methods

In this single-centre, randomized controlled trial, elderly patients undergoing surgery for a hip fracture, either hemiarthroplasty for a subcapital fracture or intramedullary nailing for an IT fracture, were screened for inclusion. Patients were randomly allocated to a study group using a sealed envelope. The TXA group consisted of 77 patients, (35 with a subcapital fracture and 42 with an IT fracture), and the control group consisted of 88 patients (29 with a subcapital fracture and 59 with an IT fracture). One dose of 15 mg/kg of intravenous (IV) TXA diluted in 100 ml normal saline (NS,) or one dose of IV placebo 100 ml NS were administered before the incision was made. The haemoglobin (Hb) concentration was measured before surgery and daily until the fourth postoperative day. The primary outcomes were the total blood loss and the rate of transfusion from the time of surgery to the fourth postoperative day.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1082 - 1087
1 Aug 2020
Yiğit Ş Arslan H Akar MS Şahin MA

Aims

Osteopetrosis (OP) is a rare hereditary disease that causes reduced bone resorption and increased bone density as a result of osteoclastic function defect. Our aim is to review the difficulties, mid-term follow-up results, and literature encountered during the treatment of OP.

Methods

This is a retrospective and observational study containing data from nine patients with a mean age of 14.1 years (9 to 25; three female, six male) with OP who were treated in our hospital between April 2008 and October 2018 with 20 surgical procedures due to 17 different fractures. Patient data included age, sex, operating time, length of stay, genetic type of the disease, previous surgery, fractures, complications, and comorbidity.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims

Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity.

Methods

A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 394 - 399
1 Mar 2020
Parker MJ Cawley S

Aims

A lack of supporting clinical studies have been published to determine the ideal length of intramedullary nail in fixation of trochanteric fractures of the hip. Nevertheless, there has been a trend to use shorter intramedullary nails for the internal fixation of trochanteric hip fractures. Our aim was to determine if the length of nail affected the outcome.

Methods

We randomized 229 patients with a trochanteric hip fracture between two implants: a ‘standard’ nail of 220 mm and a shorter nail of 175 mm, which had decreased proximal angulation (4° vs 7°) and a reduced diameter at the level of the lesser trochanter. Patients were followed up for one year by a nurse blinded to the type of implant used to determine if there were differences in mobility and pain with two nail designs. Pain was assessed on a scale of 1 (none) to 8 (severe and constant) and mobility on a scale of 1 (full mobility) to 9 (immobile).


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1408 - 1415
1 Nov 2019
Hull PD Chou DTS Lewis S Carrothers AD Queally JM Allison A Barton G Costa ML

Aims

The aim of this study was to assess the feasibility of conducting a full-scale, appropriately powered, randomized controlled trial (RCT) comparing internal fracture fixation and distal femoral replacement (DFR) for distal femoral fractures in older patients.

Patients and Methods

Seven centres recruited patients into the study. Patients were eligible if they were greater than 65 years of age with a distal femoral fracture, and if the surgeon felt that they were suitable for either form of treatment. Outcome measures included the patients’ willingness to participate, clinicians’ willingness to recruit, rates of loss to follow-up, the ability to capture data, estimates of standard deviation to inform the sample size calculation, and the main determinants of cost. The primary clinical outcome measure was the EuroQol five-dimensional index (EQ-5D) at six months following injury.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1122 - 1128
1 Sep 2019
Yombi JC Putineanu DC Cornu O Lavand’homme P Cornette P Castanares-Zapatero D

Aims

Low haemoglobin (Hb) at admission has been identified as a risk factor for mortality for elderly patients with hip fractures in some studies. However, this remains controversial. This study aims to analyze the association between Hb level at admission and mortality in elderly patients with hip fracture undergoing surgery.

Patients and Methods

All consecutive patients (prospective database) admitted with hip fracture operated in a tertiary hospital between 2012 and 2016 were analyzed. We collected patient characteristics, time to surgery, duration and type of surgery, comorbidities, Hb at admission, nadir of Hb after surgery, the use and amount of red blood cells (RBCs) transfusion products, postoperative complications, and death. The main outcome measures were mortality at 30 days, 90 days, 180 days, and one year after surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 673 - 678
1 Jul 1998
Yang KH Han DY Park HW Kang HJ Park JH

We report retrospective and prospective studies to identify the causes of fracture of the femoral neck associated with femoral shaft nailing on the same side. Of a total of 14 neck fractures in a series of 152 shaft nailings, eight were not visible on the initial pelvic radiographs. We used CT scans before and after operation, and fluoroscopy during the procedure in our prospective series, and reviewed abdominal CT scans retrospectively with the window set to bone level. Six of the eight undisplaced fractures were shown to have been present before operation, but two were iatrogenic. We recommend the preoperative use of CT scans of the femoral neck in high-risk patients such as those with associated fractures of the acetabulum, the distal femur or the patella. Early diagnosis will allow better general management and early fixation of the neck fracture


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 634 - 639
1 May 2018
Davda K Heidari N Calder P Goodier D

Aims

The management of a significant bony defect following excision of a diaphyseal atrophic femoral nonunion remains a challenge. We present the outcomes using a combined technique of acute femoral shortening, stabilized with a long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis with a temporary monolateral fixator.

Patients and Methods

Eight men and two women underwent the ‘rail and nail’ technique between 2008 and 2016. Proximal locking of the nail and removal of the external fixator was undertaken once the length of the femur had been restored and prior to full consolidation of the regenerate.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 817 - 822
1 Jun 2014
Al-Nammari SS Dawson-Bowling S Amin A Nielsen D

Conventional methods of treating ankle fractures in the elderly are associated with high rates of complication. We describe the results of treating these injuries in 48 frail elderly patients with a long calcaneotalotibial nail.

The mean age of the group was 82 years (61 to 96) and 41 (85%) were women. All were frail, with multiple medical comorbidities and their mean American Society of Anaesthesiologists score was 3 (3 to 4). None could walk independently before their operation. All the fractures were displaced and unstable; the majority (94%, 45 of 48) were low-energy injuries and 40% (19 of 48) were open.

The overall mortality at six months was 35%. Of the surviving patients, 90% returned to their pre-injury level of function. The mean pre- and post-operative Olerud and Molander questionnaire scores were 62 and 57 respectively. Complications included superficial infection (4%, two of 48); deep infection (2%, one of 48); a broken or loose distal locking screw (6%, three of 48); valgus malunion (4%, two of 48); and one below-knee amputation following an unsuccessful vascular operation. There were no cases of nonunion, nail breakage or peri-prosthetic fracture.

A calcaneotalotibial nail is an excellent device for treating an unstable fracture of the ankle in the frail elderly patient. It allows the patient to mobilise immediately and minimises the risk of bone or wound problems. A long nail which crosses the isthmus of the tibia avoids the risk of peri-prosthetic fracture associated with shorter devices.

Cite this article: Bone Joint J 2014; 96-B:817–22.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1073 - 1078
1 Aug 2008
Little NJ Verma V Fernando C Elliott DS Khaleel A

We compared the outcome of patients treated for an intertrochanteric fracture of the femoral neck with a locked, long intramedullary nail with those treated with a dynamic hip screw (DHS) in a prospective randomised study.

Each patient who presented with an extra-capsular hip fracture was randomised to operative stabilisation with either a long intramedullary Holland nail or a DHS. We treated 92 patients with a Holland nail and 98 with a DHS. Pre-operative variables included the Mini Mental test score, patient mobility, fracture pattern and American Society of Anesthesiologists grading. Peri-operative variables were anaesthetic time, operating time, radiation time and blood loss. Post-operative variables were time to mobilising with a frame, wound infection, time to discharge, time to fracture union, and mortality.

We found no significant difference in the pre-operative variables. The mean anaesthetic and operation times were shorter in the DHS group than in the Holland nail group (29.7 vs 40.4 minutes, p < 0.001; and 40.3 vs 54 minutes, p < 0.001, respectively). There was an increased mean blood loss within the DHS group versus the Holland nail group (160 ml vs 78 ml, respectively, p < 0.001). The mean time to mobilisation with a frame was shorter in the Holland nail group (DHS 4.3 days, Holland nail 3.6 days, p = 0.012). More patients needed a post-operative blood transfusion in the DHS group (23 vs seven, p = 0.003) and the mean radiation time was shorter in this group (DHS 0.9 minutes vs Holland nail 1.56 minutes, p < 0.001). The screw of the DHS cut out in two patients, one of whom underwent revision to a Holland nail. There were no revisions in the Holland nail group. All fractures in both groups were united when followed up after one year.

We conclude that the DHS can be implanted more quickly and with less exposure to radiation than the Holland nail. However, the resultant blood loss and need for transfusion is greater. The Holland nail allows patients to mobilise faster and to a greater extent. We have therefore adopted the Holland nail as our preferred method of treating intertrochanteric fractures of the hip.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 658 - 664
1 May 2014
Teo BJX Koh JSB Goh SK Png MA Chua DTC Howe TS

Management of bisphosphonate-associated subtrochanteric fractures remains opinion- or consensus-based. There are limited data regarding the outcomes of this fracture.

We retrospectively reviewed 33 consecutive female patients with a mean age of 67.5 years (47 to 91) who were treated surgically between May 2004 and October 2009. The mean follow-up was 21.7 months (0 to 53). Medical records and radiographs were reviewed to determine the post-operative ambulatory status, time to clinical and radiological union and post-fixation complications such as implant failure and need for second surgery.

The predominant fixation method was with an extramedullary device in 23 patients. 25 (75%) patients were placed on wheelchair mobilisation or no weight-bearing initially. The mean time to full weight-bearing was 7.1 months (2.2 to 29.7). The mean time for fracture site pain to cease was 6.2 months (1.2 to 17.1). The mean time to radiological union was 10.0 months (2.2 to 27.5). Implant failure was seen in seven patients (23%, 95 confidence interval (CI) 11.8 to 40.9). Revision surgery was required in ten patients (33%, 95 CI 19.2 to 51.2).

A large proportion of the patients required revision surgery and suffered implant failure. This fracture is associated with slow healing and prolonged post-operative immobility.

Cite this article: Bone Joint J 2014;96-B:658–64.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1406 - 1409
1 Oct 2013
Wähnert D Lange JH Schulze M Gehweiler D Kösters C Raschke MJ

The augmentation of fixation with bone cement is increasingly being used in the treatment of severe osteoporotic fractures. We investigated the influence of bone quality on the mechanics of augmentation of plate fixation in a distal femoral fracture model (AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral models were randomly assigned to either an augmented or a non-augmented group. Fixation was performed using a locking compression plate. In the augmented group additionally 1 ml of bone cement was injected into the screw hole before insertion of the screw. Biomechanical testing was performed in axial sinusoidal loading. Augmentation significantly reduced the cut-out distance in the osteoporotic models by about 67% (non-augmented mean 0.30 mm (sd 0.08) vs augmented 0.13 mm (sd 0.06); p = 0.017). There was no statistical reduction in this distance following augmentation in the non-osteoporotic models (non-augmented mean 0.15 mm (sd 0.02) vs augmented 0.15 mm (sd 0.07); p = 0.915). In the osteoporotic models, augmentation significantly increased stability (p = 0.017).

Cite this article: Bone Joint J 2013;95-B:1406–9.