We reviewed three infants with destructive osteomyelitis involving the proximal tibial
We describe three cases of infantile tibia vara
resulting from an atraumatic slip of the proximal tibial epiphysis
upon the metaphysis. There appears to be an association between
this condition and severe obesity. Radiologically, the condition
is characterised by a dome-shaped metaphysis, an open growth plate
and disruption of the continuity between the lateral borders of
the
We reviewed the clinical and radiological results of six patients who had sustained traumatic separation of the distal
Three cases of a rare complication of Salter Type II fracture-separations of the distal tibial
We have reviewed 12 cases of fracture-separation of the distal humeral
Ischaemia resulting from increased joint pressure may play a role in the pathogenesis of necrosis of the femoral head
Six mechanisms which may produce fracture-separation of the proximal humeral
We have previously reported cryoablation-assisted joint-sparing surgery for osteosarcoma with epiphyseal involvement. However, it is not clear whether this is a comparable alternative to conventional joint arthroplasty in terms of oncological and functional outcomes. A total of 22 patients who had localized osteosarcoma with epiphyseal involvement around the knee and underwent limb salvage surgery were allocated to joint preservation (JP) group and joint arthroplasty (JA) group. Subjects were followed with radiographs, Musculoskeletal Tumor Society (MSTS) score, and clinical evaluations at one, three, and five years postoperatively.Aims
Methods
We report a case of neonatal separation of the distal humeral
A rare form of injury to the distal tibial growth plate is described. Only two patients with such an injury have been reported previously. The injury, rotational displacement of the distal tibial
We have reviewed the notes and radiographs of 57 patients with fractures of the proximal humeral
In immature long bones, radical excision of malignant tumours of the metaphysis may necessitate sacrifice of the adjacent
Fracture separation of the capital femoral epiphysis occurring during attempted closed reduction of a traumatic dislocation of the hip is described in two adolescents. Although this complication is extremely rare, the prognosis of fracture separation with dislocation of the
Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis). Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system.Aims
Methods
Osteochondrosis juvenilis is caused by a dysfunction of endochondral ossification. Several epiphyses and apophyses can be affected, but osteochondrosis juvenilis of the medial malleolus has not been reported. We describe a 12-year-old boy with bilateral pes planovalgus who was affected by this condition. Conservative management was successful. The presentation, aetiology and treatment are described and the importance of including it in the differential diagnosis is discussed.
We present our experience of the modified Dunn
procedure in combination with a Ganz surgical dislocation of the hip
to treat patients with severe slipped capital femoral epiphysis
(SCFE). The aim was to prospectively investigate whether this technique
is safe and reproducible. We assessed the degree of reduction, functional
outcome, rate of complications, radiological changes and range of
movement in the hip. There were 28 patients with a mean follow-up
of 38.6 months (24 to 84). The lateral slip angle was corrected
by a mean of 50.9° (95% confidence interval 44.3 to 57.5). The mean
modified Harris hip score at the final follow-up was 89.1 ( Cite this article: