Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims. The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. Methods. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals. Results. The spiral and oblique fracture patterns withstood simulated weight-bearing with minimal displacement. The multifragmented model had early implant failure with breaking of the distal locking screws. The spiral fracture model shortened by a mean of 0.3 mm (SD 0.2), and developed a mean coronal angulation of 2.0° (SD 1.9°) and a mean sagittal angulation of 1.2° (SD 1.1°). On average, 88% of the shortening, 74% of the change in coronal alignment, and 75% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. The oblique fracture model shortened by a mean of 0.2 mm (SD 0.1) and developed a mean coronal angulation of 2.4° (SD 1.6°) and a mean sagittal angulation of 2.6° (SD 1.4°). On average, 44% of the shortening, 39% of the change in coronal alignment, and 79% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. Conclusion. For spiral and oblique fracture patterns, simulated weight-bearing resulted in a clinically acceptable degree of displacement. Most displacement occurred early in the test period, and the rate of displacement decreased over time. Based on this model, we offer evidence that early weight-bearing appears safe for well reduced oblique and spiral fractures, but not in multifragmented patterns that have poor bone contact. Cite this article: Bone Joint J 2021;103-B(2):294–298


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1107 - 1112
1 Aug 2012
Bugler KE Watson CD Hardie AR Appleton P McQueen MM Court-Brown CM White TO

Techniques for fixation of fractures of the lateral malleolus have remained essentially unchanged since the 1960s, but are associated with complication rates of up to 30%. The fibular nail is an alternative method of fixation requiring a minimal incision and tissue dissection, and has the potential to reduce the incidence of complications. We reviewed the results of 105 patients with unstable fractures of the ankle that were fixed between 2002 and 2010 using the Acumed fibular nail. The mean age of the patients was 64.8 years (22 to 95), and 80 (76%) had significant systemic medical comorbidities. Various different configurations of locking screw were assessed over the study period as experience was gained with the device. Nailing without the use of locking screws gave satisfactory stability in only 66% of cases (4 of 6). Initial locking screw constructs rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable. Overall, seven patients had loss of fixation of the fracture and there were five post-operative wound infections related to the distal fibula. This lead to the development of the current technique with a screw across the syndesmosis in addition to a distal locking screw. In 21 patients treated with this technique there have been no significant complications and only one superficial wound infection. Good fracture reduction was achieved in all of these patients. The mean physical component Short-Form 12, Olerud and Molander score, and American Academy of Orthopaedic Surgeons Foot and Ankle outcome scores at a mean of six years post-injury were 46 (28 to 61), 65 (35 to 100) and 83 (52 to 99), respectively. There have been no cases of fibular nonunion. Nailing of the fibula using our current technique gives good radiological and functional outcomes with minimal complications, and should be considered in the management of patients with an unstable ankle fracture.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 817 - 822
1 Jun 2014
Al-Nammari SS Dawson-Bowling S Amin A Nielsen D

Conventional methods of treating ankle fractures in the elderly are associated with high rates of complication. We describe the results of treating these injuries in 48 frail elderly patients with a long calcaneotalotibial nail. The mean age of the group was 82 years (61 to 96) and 41 (85%) were women. All were frail, with multiple medical comorbidities and their mean American Society of Anaesthesiologists score was 3 (3 to 4). None could walk independently before their operation. All the fractures were displaced and unstable; the majority (94%, 45 of 48) were low-energy injuries and 40% (19 of 48) were open. . The overall mortality at six months was 35%. Of the surviving patients, 90% returned to their pre-injury level of function. The mean pre- and post-operative Olerud and Molander questionnaire scores were 62 and 57 respectively. Complications included superficial infection (4%, two of 48); deep infection (2%, one of 48); a broken or loose distal locking screw (6%, three of 48); valgus malunion (4%, two of 48); and one below-knee amputation following an unsuccessful vascular operation. There were no cases of nonunion, nail breakage or peri-prosthetic fracture. . A calcaneotalotibial nail is an excellent device for treating an unstable fracture of the ankle in the frail elderly patient. It allows the patient to mobilise immediately and minimises the risk of bone or wound problems. A long nail which crosses the isthmus of the tibia avoids the risk of peri-prosthetic fracture associated with shorter devices. Cite this article: Bone Joint J 2014; 96-B:817–22


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 456 - 461
1 Mar 2021
Sasaki G Watanabe Y Yasui Y Nishizawa M Saka N Kawano H Miyamoto W

Aims

To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes.

Methods

A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1138 - 1143
1 Sep 2019
MacDonald DRW Caba-Doussoux P Carnegie CA Escriba I Forward DP Graf M Johnstone AJ

Aims

The aim of this study was to compare the incidence of anterior knee pain after antegrade tibial nailing using suprapatellar and infrapatellar surgical approaches

Patients and Methods

A total of 95 patients with a tibial fracture requiring an intramedullary nail were randomized to treatment using a supra- or infrapatellar approach. Anterior knee pain was assessed at four and six months, and one year postoperatively, using the Aberdeen Weightbearing Test – Knee (AWT-K) score and a visual analogue scale (VAS) score for pain. The AWT-K is an objective patient-reported outcome measure that uses weight transmitted through the knee when kneeling as a surrogate for anterior knee pain.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 951 - 957
1 Jul 2017
Poole WEC Wilson DGG Guthrie HC Bellringer SF Freeman R Guryel E Nicol SG

Aims

Fractures of the distal femur can be challenging to manage and are on the increase in the elderly osteoporotic population. Management with casting or bracing can unacceptably limit a patient’s ability to bear weight, but historically, operative fixation has been associated with a high rate of re-operation. In this study, we describe the outcomes of fixation using modern implants within a strategy of early return to function.

Patients and Methods

All patients treated at our centre with lateral distal femoral locking plates (LDFLP) between 2009 and 2014 were identified. Fracture classification and operative information including weight-bearing status, rates of union, re-operation, failure of implants and mortality rate, were recorded.


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 385 - 389
1 Mar 2014
Attal R Maestri V Doshi HK Onder U Smekal V Blauth M Schmoelz W

Using human cadaver specimens, we investigated the role of supplementary fibular plating in the treatment of distal tibial fractures using an intramedullary nail. Fibular plating is thought to improve stability in these situations, but has been reported to have increased soft-tissue complications and to impair union of the fracture. We proposed that multidirectional locking screws provide adequate stability, making additional fibular plating unnecessary. A distal tibiofibular osteotomy model performed on matched fresh-frozen lower limb specimens was stabilised with reamed nails using conventional biplanar distal locking (CDL) or multidirectional distal locking (MDL) options with and without fibular plating. Rotational stiffness was assessed under a constant axial force of 150 N and a superimposed torque of ± 5 Nm. Total movement, and neutral zone and fracture gap movement were analysed.

In the CDL group, fibular plating improved stiffness at the tibial fracture site, albeit to a small degree (p = 0.013). In the MDL group additional fibular plating did not increase the stiffness. The MDL nail without fibular plating was significantly more stable than the CDL nail with an additional fibular plate (p = 0.008).

These findings suggest that additional fibular plating does not improve stability if a multidirectional distal locking intramedullary nail is used, and is therefore unnecessary if not needed to aid reduction.

Cite this article: Bone Joint J 2014;96-B:385–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 385 - 390
1 Mar 2012
Thompson RN Phillips JRA McCauley SHJ Elliott JRM Moran CG

We performed a retrospective review of all patients admitted to two large University Hospitals in the United Kingdom over a 24-month period from January 2008 to January 2010 to identify the incidence of atypical subtrochanteric and femoral shaft fractures and their relationship to bisphosphonate treatment. Of the 3515 patients with a fracture of the proximal femur, 156 fractures were in the subtrochanteric region. There were 251 femoral shaft fractures. The atypical fracture pattern was seen in 27 patients (7%) with 29 femoral shaft or subtrochanteric fractures. A total of 22 patients with 24 atypical fractures were receiving bisphosphonate treatment at the time of fracture. Prodromal pain was present in nine patients (11 fractures); 11 (50%) of the patients on bisphosphonates suffered 12 spontaneous fractures, and healing of these fractures was delayed in a number of patients. This large dual-centre review has established the incidence of atypical femoral fractures at 7% of the study population, 81% of whom had been on bisphosphonate treatment for a mean of 4.6 years (0.04 to 12.1).

This study does not advocate any change in the use of bisphosphonates to prevent fragility fractures but attempts to raise awareness of this possible problem so symptomatic patients will be appropriately investigated. However, more work is required to identify the true extent of this new and possibly increasing problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 68 - 75
1 Jan 2005
Miedel R Ponzer S Törnkvist H Söderqvist A Tidermark J

We studied 217 patients with an unstable trochanteric or subtrochanteric fracture who had been randomly allocated to treatment by either internal fixation with a standard Gamma nail (SGN) or a Medoff sliding plate (MSP, biaxial dynamisation mode). Their mean age was 84 years (65 to 99) and they were reviewed at four and 12 months after surgery. Assessments of outcome included general complications, technical failures, revision surgery, activities of daily living (ADL), hip function (Charnley score) and the health-related quality of life (HRQOL, EQ-5D).

The rate of technical failure in patients with unstable trochanteric fractures was 6.5% (6/93) (including intra-operative femoral fractures) in the SGN group and 5.2% (5/96) in the MSP group. In patients with subtrochanteric fractures, there were no failures in the SGN group (n = 16) and two in the MSP group (n = 12). In the SGN group, there were intra-operative femoral fractures in 2.8% (3/109) and no post-operative fractures. There was a reduced need for revision surgery in the SGN group compared with the MSP group (8.3%; 9/108; p = 0.072). The SGN group also showed a lower incidence of severe general complications (p < 0.05) and a trend towards a lower incidence of wound infections (p = 0.05). There were no differences between the groups regarding the outcome of ADL, hip function or the HRQOL. The reduction in the HRQOL (EQ-5Dindexscore) was significant in both groups compared with that before the fracture (p < 0.005).

Our findings indicate that the SGN showed good results in both trochanteric and subtrochanteric fractures. The limited number of intra-operative femoral fractures did not influence the outcome or the need for revision surgery. Moreover, the SGN group had a reduced number of serious general complications and wound infections compared with the MSP group. The MSP in the biaxial dynamisation mode had a low rate of failure in trochanteric fractures but an unacceptably high rate when used in the biaxial dynamisation mode in subtrochanteric fractures.

The negative influence of an unstable trochanteric or subtrochanteric fracture on the quality of life was significant regardless of the surgical method.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 385 - 387
1 Mar 2009
Pichler W Grechenig W Tesch NP Weinberg AM Heidari N Clement H

Percutaneous stabilisation of tibial fractures by locking plates has become an accepted form of osteosynthesis. A potential disadvantage of this technique is the risk of damage to the neurovascular bundles in the anterior and peroneal compartments. Our aim in this anatomical study was to examine the relationship of the deep peroneal nerve to a percutaneously-inserted Less Invasive Stabilisation System tibial plate in the lower limbs of 18 cadavers. Screws were inserted through stab incisions. The neurovascular bundle was dissected to reveal its relationship to the plate and screws.

In all cases, the deep peroneal nerve was in direct contact with the plate between the 11th and the 13th holes. In ten specimens the nerve crossed superficial to the plate, in six it was interposed between the plate and the bone and in the remaining two specimens it coursed at the edge of the plate.

Percutaneous insertion of plates with more than ten holes is not recommended because of the risk of injury to the neurovascular structures. When longer plates are required we suggest distal exposure so that the neurovascular bundle may be displayed and protected.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1206 - 1209
1 Sep 2007
Moonot P Ashwood N Hamlet M

Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) (t-test, p = 0.8443). There was one case each of nonunion, malunion and a broken screw in the elderly population.

This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1495 - 1497
1 Nov 2007
Jones BG Mehin R Young D

Intramedullary tibial nailing was performed in ten paired cadavers and the insertion of a medial-to-lateral proximal oblique locking screw was simulated in each specimen. Anatomical dissection was undertaken to determine the relationship of the common peroneal nerve to the cross-screw.

The common peroneal nerve was contacted directly in four tibiae and the cross-screw was a mean of 2.6 mm (1.0 to 10.7) away from the nerve in the remaining 16. Iatrogenic injury to the common peroneal nerve by medial-to-lateral proximal oblique locking screws is therefore a significant risk during tibial nailing.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 102 - 107
1 Jan 2009
Zenke Y Sakai A Oshige T Moritani S Nakamura T

A total of 118 consecutive patients with a fracture of the distal radius were treated with a volar locking plate; 50 patients had no ulnar styloid fracture, 41 had a basal ulnar styloid fracture, and 27 had a fracture of the tip of the ulnar styloid. There were no significant differences in radiological and clinical results among the three groups. The outcome was good and was independent of the presence of a fracture of the ulnar styloid. A total of five patients (4.2%) had persistent ulnar-sided wrist pain at final follow-up. Nonunion of the ulnar styloid fracture did not necessarily lead to ulnar wrist pain. Patients with persistent ulnar pain had a higher mean initial ulnar variance and increased post-operative loss of ulnar variance.

The presence of an associated ulnar styloid fracture of the ulnar styloid does not adversely affect the outcome in patients with a fracture of the distal radius treated by volar plating.