Aims. The aim of this study was to investigate the difference in functional outcome after repair and non-repair of the pronator quadratus muscle in patients undergoing surgical treatment for a distal radial fracture with volar plating. Patients and Methods. A total of 72 patients with a distal radial fracture were included in this randomized
Aims. The aim of this study was to assess and compare active rotation of the forearm in normal subjects after the application of a short-arm cast (SAC) in the semisupination position and a long-arm cast (LAC) in the neutral position. A
We aimed to compare reoperations following distal radial fractures (DRFs) managed with early fixation versus delayed fixation following initial closed reduction (CR). We used administrative databases in Ontario, Canada, to identify DRF patients aged 18 years or older from 2003 to 2016. We used procedural and fee codes within 30 days to determine which patients underwent early fixation (≤ seven days) or delayed fixation following CR. We grouped patients in the delayed group by their time to definitive fixation (eight to 14 days, 15 to 21 days, and 22 to 30 days). We used intervention and diagnostic codes to identify reoperations within two years. We used multivariable regression to compare the association between early versus delayed fixation and reoperation for all patients and stratified by age (18 to 60 years and > 60 years).Aims
Methods
The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.Aims
Methods
It is not clear which type of casting provides the best initial treatment in adults with a distal radial fracture. Given that between 32% and 64% of adequately reduced fractures redisplace during immobilization in a cast, preventing redisplacement and a disabling malunion or secondary surgery is an aim of treatment. In this study, we investigated whether circumferential casting leads to fewer fracture redisplacements and better one-year outcomes compared to plaster splinting. In a pragmatic, open-label, multicentre, two-period cluster-randomized superiority trial, we compared these two types of casting. Recruitment took place in ten hospitals. Eligible patients aged ≥ 18 years with a displaced distal radial fracture, which was acceptably aligned after closed reduction, were included. The primary outcome measure was the rate of redisplacement within five weeks of immobilization. Secondary outcomes were the rate of complaints relating to the cast, clinical outcomes at three months, patient-reported outcome measures (PROMs) (using the numerical rating scale (NRS), the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores), and adverse events such as the development of compartment syndrome during one year of follow-up. We used multivariable mixed-effects logistic regression for the analysis of the primary outcome measure.Aims
Methods
This article is a systematic review of the published
literature about the biomechanics, functional outcome and complications
of intramedullary nailing of fractures of the distal radius. We searched the Medline and EMBASE databases and included all
studies which reported the outcome of intramedullary (IM) nailing
of fractures of the distal radius. Data about functional outcome,
range of movement (ROM), strength and complications, were extracted.
The studies included were appraised independently by both authors
using a validated quality assessment scale for non-controlled studies
and the CONSORT statement for randomised controlled trials (RCTs). The search strategy revealed 785 studies, of which 16 were included
for full paper review. These included three biomechanical studies,
eight case series and five randomised controlled trials (RCTs). . The biomechanical studies concluded that IM nails were at least
as strong as locking plates. The
The aim of the Scaphoid Waist Internal Fixation for Fractures Trial (SWIFFT) was to determine the optimal treatment for adults with a bicortical undisplaced or minimally displaced fracture of the waist of the scaphoid, comparing early surgical fixation with initial cast immobilization, with immediate fixation being offered to patients with nonunion. A cost-effectiveness analysis was conducted to assess the relative merits of these forms of treatment. The differences in costs to the healthcare system and quality-adjusted life years (QALYs) of the patients over the one-year follow-up of the trial in the two treatment arms were estimated using regression analysis.Aims
Methods
The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging. A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.Aims
Methods
The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires. This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications.Aims
Patients and Methods
The aim of this meta-analysis was to assess the safety and efficacy
of collagenase clostridium histolyticum compared with fasciectomy
and percutaneous needle fasciotomy (PNF) for Dupuytren’s disease. We systematically searched PubMed, EMBASE, LILACS, Web of Science,
Cochrane, Teseo and the ClinicalTrials.gov registry for clinical
trials and cohort or case-control studies which compared the clinical
outcomes and adverse effects of collagenase with those of fasciectomy
or PNF. Of 1345 articles retrieved, ten were selected. They described
the outcomes of 425 patients treated with collagenase and 418 treated
by fasciectomy or PNF. Complications were assessed using inverse-variance
weighted odds ratios (ORs). Clinical efficacy was assessed by differences
between the means for movement of the joint before and after treatment.
Dose adjustment was applied in all cases.Aims
Materials and Methods
We conducted a study to determine whether radiological parameters
correlate with patient reported functional outcome, health-related
quality of life and physical measures of function in patients with
a fracture of the distal radius. The post-operative palmar tilt and ulnar variance at six weeks
and 12 months were correlated with the Patient Rated Wrist Evaluation,
Disabilities of the Arm, Shoulder and Hand, and EuroQol scores,
grip strength, pinch strength and range of movement at three, six
and 12 months for 50 patients (mean age 57 years; 26 to 85) having surgical
fixation, with either percutaneous pinning or reconstruction with
a volar plate, for a fracture of the distal radius.Aims
Patients and Methods
Our purpose was to determine the quality of current randomised
controlled trials (RCTs) in hand surgery using standardised metrics. Based on five-year mean impact factors, we selected the six journals
that routinely publish studies of upper extremity surgery. Using
a journal-specific search query, 62 RCTs met our inclusion criteria.
Then three blinded reviewers used the Jadad and revised Coleman Methodology
Score (RCMS) to assess the quality of the manuscripts.Aims
Materials and Methods
We conducted an observational radiographic study
to determine the inter- and intra-observer reliability of the AO classification
of fractures of the distal radius. Plain posteroanterior and lateral
radiographs of 456 patients with an acute fracture of the distal
radius were classified by a consultant orthopaedic hand specialist
and two specialist trainees, and the k coefficient for the inter-
and intra-observer reliability of the type, group and subgroup classification
was calculated. Only the type of fracture (A, B or C) was found to provide substantial
intra-observer reliability (k type 0.65). The inclusion
of ‘group’ and ‘subgroup’ into the classification reduced the inter-observer
reliability to fair (kgroup 0.29, ksubgroup =
0.28) and the intra-observer reliability to moderate (kgroup 0.53,
ksubgroup 0.49). Disagreement was found to arise between
specific subgroups, which may be amenable to clarification. Cite this article:
Penetration of the dorsal screw when treating
distal radius fractures with volar locking plates is an avoidable complication
that causes lesions of the extensor tendon in between 2% and 6%
of patients. We examined axial fluoroscopic views of the distal
end of the radius to observe small amounts of dorsal screw penetration,
and determined the ideal angle of inclination of the x-ray beam
to the forearm when making this radiological view. Six volar locking plates were inserted at the wrists of cadavers.
The actual screw length was measured under direct vision through
a dorsal approach to the distal radius. Axial radiographs were performed
for different angles of inclination of the forearm at the elbow. Comparing axial radiological measurements and real screw length,
a statistically significant correlation could be demonstrated at
an angle of inclination between 5° and 20°. The ideal angle of inclination
required to minimise the risk of implanting over-long screws in
a dorsal horizon radiological view is 15°. Cite this article: