Acute and chronic injuries of the interosseus membrane can result in longitudinal instability of the forearm. Reconstruction of the central band of the interosseus membrane can help to restore biomechanical stability. Different methods have been used to reconstruct the central band, including tendon grafts, bone-ligament-bone grafts, and synthetic grafts. This Idea, Development, Exploration, Assessment, and Long-term (IDEAL) phase 1 study aims to review the clinical results of reconstruction using a synthetic braided cross-linked graft secured at either end with an Endobutton to restore the force balance between the bones of the forearm. An independent retrospective review was conducted of a consecutive series of 21 patients with longitudinal instability injuries treated with anatomical central band reconstruction between February 2011 and July 2019. Patients with less than 12 months’ follow-up or who were treated acutely were excluded, leaving 18 patients in total. Preoperative clinical and radiological assessments were compared with prospectively gathered data using range of motion and the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) functional outcome score.Aims
Methods
The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA). Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.Aims
Methods
Bone defects are frequently observed in anterior shoulder instability. Over the last decade, knowledge of the association of bone loss with increased failure rates of soft-tissue repair has shifted the surgical management of chronic shoulder instability. On the glenoid side, there is no controversy about the critical glenoid bone loss being 20%. However, poor outcomes have been described even with a subcritical glenoid bone defect as low as 13.5%. On the humeral side, the Hill-Sachs lesion should be evaluated concomitantly with the glenoid defect as the two sides of the same bipolar lesion which interact in the instability process, as described by the glenoid track concept. We advocate adding remplissage to every Bankart repair in patients with a Hill-Sachs lesion, regardless of the glenoid bone loss. When critical or subcritical glenoid bone loss occurs in active patients (> 15%) or bipolar off-track lesions, we should consider anterior glenoid bone reconstructions. The techniques have evolved significantly over the last two decades, moving from open procedures to arthroscopic, and from screw fixation to metal-free fixation. The new arthroscopic techniques of glenoid bone reconstruction procedures allow precise positioning of the graft, identification, and treatment of concomitant injuries with low morbidity and faster recovery. Given the problems associated with bone resorption and metal hardware protrusion, the new metal-free techniques for Latarjet or free bone block procedures seem a good solution to avoid these complications, although no long-term data are yet available. Cite this article:
Rotator cuff tears are common in middle-aged and elderly patients. Despite advances in the surgical repair of rotator cuff tears, the rates of recurrent tear remain high. This may be due to the complexity of the tendons of the rotator cuff, which contributes to an inherently hostile healing environment. During the past 20 years, there has been an increased interest in the use of biologics to complement the healing environment in the shoulder, in order to improve rotator cuff healing and reduce the rate of recurrent tears. The aim of this review is to provide a summary of the current evidence for the use of forms of biological augmentation when repairing rotator cuff tears. Cite this article:
The aim of this study was to compare the characteristics and outcomes of L-shaped and reverse L-shaped rotator cuff tears. A total of 82 shoulders (81 patients) after arthroscopic rotator cuff repair were retrospectively enrolled. The mean age of the patients was 62 years (SD 6), 33 shoulders (40.2%) were in male patients, and 57 shoulders (69.5%) were the right shoulder. Of these, 36 shoulders had an L-shaped tear (group L) and 46 had a reverse L-shaped tear (group RL). Both groups were compared regarding characteristics, pre- and postoperative pain, and functional outcomes. Muscle status was assessed by preoperative MRI, and re-tear rates by postoperative ultrasonography or MRI.Aims
Methods
Patients with recurrent anterior dislocation of the shoulder commonly have an anterior osseous defect of the glenoid. Once the defect reaches a critical size, stability may be restored by bone grafting. The critical size of this defect under non-physiological loading conditions has previously been identified as 20% of the length of the glenoid. As the stability of the shoulder is load-dependent, with higher joint forces leading to a loss of stability, the aim of this study was to determine the critical size of an osseous defect that leads to further anterior instability of the shoulder under physiological loading despite a Bankart repair. Two finite element (FE) models were used to determine the risk of dislocation of the shoulder during 30 activities of daily living (ADLs) for the intact glenoid and after creating anterior osseous defects of increasing magnitudes. A Bankart repair was simulated for each size of defect, and the shoulder was tested under loading conditions that replicate Aims
Patients and Methods
Scapular notching is a frequently observed radiographic phenomenon
in reverse shoulder arthroplasty (RSA), signifying impingement of
components. The purposes of this study were to evaluate the effect
of glenoid component size and glenosphere type on impingement-free
range of movement (ROM) for extension and internal and external
rotation in a virtual RSA model, and to determine the optimal configuration
to reduce the incidence of friction-type scapular notching. Preoperative CT scans obtained in 21 patients (three male, 18
female) with primary osteoarthritis were analyzed using modelling
software. Two concurrent factors were tested for impingement-free
ROM and translation of the centre of rotation: glenosphere diameter
(36 mm Aims
Materials and Methods
The aim of this study was to assess hypertrophy of the extra-articular
tendon of the long head of biceps (LHB) in patients with a rotator
cuff tear. The study involved 638 shoulders in 334 patients (175 men, 159
women, mean age 62.6 years; 25 to 81) with unilateral symptomatic
rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon
in the bicipital groove was measured pre-operatively in both shoulders
using ultrasound. There were 154 asymptomatic rotator cuff tears
in the contralateral shoulder. Comparisons were made between those
with a symptomatic tear, an asymptomatic tear and those with no
rotator cuff tear. In the affected shoulders, the CSAs were compared
in relation to the location and size of the rotator cuff tear. Aims
Patients and Methods
Our aim was to describe the atypical pattern of increased fatty
degeneration in the infraspinatus muscle compared with the supraspinatus
in patients with a massive rotator cuff tear. We also wished to
describe the nerve conduction and electromyography findings in these
patients. A cohort of patients undergoing surgery for a massive rotator
cuff tear was identified and their clinical records obtained. Their
MRI images were reviewed to ascertain the degree of retraction of
the torn infraspinatus and supraspinatus muscles, and the degree
of fatty degeneration in both muscles was recorded. Nerve conduction studies
were also performed in those patients who showed more degeneration
in the infraspinatus than in the supraspinatus.Aims
Patients and Methods
Dislocation of the acromioclavicular joint is
a relatively common injury and a number of surgical interventions
have been described for its treatment. Recently, a synthetic ligament
device has become available and been successfully used, however,
like other non-native solutions, a compromise must be reached when
choosing non-anatomical locations for their placement. This cadaveric
study aimed to assess the effect of different clavicular anchorage points
for the Lockdown device on the reduction of acromioclavicular joint
dislocations, and suggest an optimal location. We also assessed
whether further stability is provided using a coracoacromial ligament
transfer (a modified Neviaser technique). The acromioclavicular
joint was exposed on seven fresh-frozen cadaveric shoulders. The
joint was reconstructed using the Lockdown implant using four different
clavicular anchorage points and reduction was measured. The coracoacromial
ligament was then transferred to the lateral end of the clavicle,
and the joint re-assessed. If the Lockdown ligament was secured
at the level of the conoid tubercle, the acromioclavicular joint
could be reduced anatomically in all cases. If placed medial or
2 cm lateral, the joint was irreducible. If the Lockdown was placed
1 cm lateral to the conoid tubercle, the joint could be reduced
with difficulty in four cases. Correct placement of the Lockdown
device is crucial to allow anatomical joint reduction. Even when the
Lockdown was placed over the conoid tubercle, anterior clavicle
displacement remained but this could be controlled using a coracoacromial
ligament transfer. Cite this article:
Determining and accurately restoring the flexion-extension
axis of the elbow is essential for functional recovery after total
elbow arthroplasty (TEA). We evaluated the effect of morphological
features of the elbow on variations of alignment of the components
at TEA. Morphological and positioning variables were compared by
systematic CT scans of 22 elbows in 21 patients after TEA. There were five men and 16 women, and the mean age was 63 years
(38 to 80). The mean follow-up was 22 months (11 to 44). The anterior offset and version of the humeral components were
significantly affected by the anterior angulation of the humerus
(p = 0.052 and p = 0.004, respectively). The anterior offset and
version of the ulnar components were strongly significantly affected
by the anterior angulation of the ulna (p <
0.001 and p <
0.001). The closer the anterior angulation of the ulna was to the joint,
the lower the ulnar anterior offset (p = 0.030) and version of the
ulnar component (p = 0.010). The distance from the joint to the
varus angulation also affected the lateral offset of the ulnar component
(p = 0.046). Anatomical variations at the distal humerus and proximal ulna
affect the alignment of the components at TEA. This is explained
by abutment of the stems of the components and is particularly severe
when there are substantial deformities or the deformities are close
to the joint. Cite this article:
To prevent insufficiency of the triceps after
total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar
approach. This study evaluates the clinical results and post-operative
alignment of the prosthesis using this approach. We reviewed 25 elbows in 23 patients. There were five men and
18 women with a mean age of 69 years (54 to 83). There were 18 elbows
with rheumatoid arthritis, six with a fracture or pseudoarthrosis
and one elbow with osteoarthritis. Post-operative complications included one intra-operative fracture,
one elbow with heterotopic ossification, one transient ulnar nerve
palsy, and one elbow with skin necrosis, but no elbow was affected
by insufficiency of the triceps. Patients were followed for a mean of 42 months (24 to 77). The
mean post-operative Japanese Orthopaedic Association Elbow Score
was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8
(65 to 100). The mean post-operative flexion/extension of the elbow
was 135°/-8°. The Manual Muscle Testing score of the triceps was
5 in 23 elbows and 2 in two elbows (one patient). The mean alignment
of the implants examined by 3D-CT was 2.8° pronation (standard deviation
( The triceps-sparing ulnar approach allows satisfactory alignment
of the implants, is effective in preventing post-operative triceps
insufficiency, and gives satisfactory short-term results. Cite this article: 2015;97-B:1096–1101.
We measured the tension in the interosseous membrane
in six cadaveric forearms using an Cite this article:
The aim of this review is to address controversies
in the management of dislocations of the acromioclavicular joint. Current
evidence suggests that operative rather than non-operative treatment
of Rockwood grade III dislocations results in better cosmetic and
radiological results, similar functional outcomes and longer time
off work. Early surgery results in better functional and radiological
outcomes with a reduced risk of infection and loss of reduction compared
with delayed surgery. Surgical options include acromioclavicular fixation, coracoclavicular
fixation and coracoclavicular ligament reconstruction. Although
non-controlled studies report promising results for arthroscopic
coracoclavicular fixation, there are no comparative studies with
open techniques to draw conclusions about the best surgical approach.
Non-rigid coracoclavicular fixation with tendon graft or synthetic
materials, or rigid acromioclavicular fixation with a hook plate,
is preferable to fixation with coracoclavicular screws owing to
significant risks of loosening and breakage. The evidence, although limited, also suggests that anatomical
ligament reconstruction with autograft or certain synthetic grafts
may have better outcomes than non-anatomical transfer of the coracoacromial
ligament. It has been suggested that this is due to better restoration
horizontal and vertical stability of the joint. Despite the large number of recently published studies, there
remains a lack of high-quality evidence, making it difficult to
draw firm conclusions regarding these controversial issues. Cite this article: