Despite the expansion of arthroscopic surgery
of the shoulder, the open deltopectoral approach to the shoulder
is still frequently used, for example in fracture fixation and shoulder
replacement. However, it is sometimes accompanied by unexpected
bleeding. The cephalic vein is the landmark for the deltopectoral
interval, yet its intimate relationship with the deltoid
This study investigates and defines the topographic
anatomy of the medial femoral circumflex
We describe a case of lumbosacral plexopathy caused by an isolated aneurysm of the common iliac
Aims. We aimed to quantify the relative contributions of the medial
femoral circumflex
The brachial
We studied 12 consecutive patients with facet joint dislocation in the cervical spine to assess the incidence, site and clinical sequelae of occlusion of the extracranial vertebral
1. Two cases of rupture of the axillary
Rupture of an aneurysm of the common iliac
We report a case in which the popliteal
Transarticular screws at the C1 to C2 level of the cervical spine provide rigid fixation, but there is a danger of injury to a vertebral
We have investigated iatrogenic popliteal artery
injuries (PAI) during non arthroplasty knee surgery regarding mechanism
of injury, treatment and outcomes, and to identify successful strategies
when injury occurs. In all, 21 iatrogenic popliteal
We performed superselective angiography in 28 hips in 25 patients with Perthes’ disease in order to study the blood supply of the lateral epiphyseal
Popliteal
We report a 30-year-old patient who was involved in a high-velocity road traffic accident and developed a left-sided hemiparesis, which was noted in the post-operative period following bilateral femoral intramedullary nailing. CT scanning of the brain revealed infarcts in the right frontal and parietal lobes in the distribution of the right middle cerebral
A case of complete rupture of the axillary
1. Complete rupture of the axillary
Vascular injuries after total hip arthroplasty are occasionally reported, but we have found only two cases of major arterial occlusion, and none at all involving the common femoral
The proximal humerus internal locking system is an internal fixation device consisting of a low-profile plate and locking screws, which is used for the fixation of three- and four-part fractures of the proximal humerus. We describe a case in which the screws cut out of the humeral head causing injury to the axillary
1. A case is described ofcomplete rupture ofthe second part of the axillary
Fractures of the proximal humerus with concomitant vascular injury are rare in children. We describe the presentation, diagnosis, and treatment of a fracture of the proximal humerus in association with an axillary