Advertisement for orthosearch.org.uk
Results 1 - 20 of 40
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1049 - 1053
1 Aug 2009
Braunstein V Kirchhoff C Ockert B Sprecher CM Korner M Mutschler W Wiedemann E Biberthaler P

In 100 patients the fulcrum axis which is the line connecting the anterior tip of the coracoid and the posterolateral angle of the acromion, was used to position true anteroposterior radiographs of the shoulder. This method was then compared with the conventional radiological technique in a further 100 patients. Three orthopaedic surgeons counted the number of images without overlap between the humeral head and glenoid and calculated the amount of the glenoid surface visible in each radiograph. The analysis was repeated for intraobserver reliability. The learning curves of both techniques were studied. The amount of free visible glenoid space was significantly higher using the fulcrum-axis method (64 vs 31) and the comparable glenoid size increased significantly (8.56 vs 6.47). Thus the accuracy of the anteroposterior radiographs of the shoulder is impaired by using this technique. The intra and interobserver reliability showed a high consistency. No learning curve was observed for either technique


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1470 - 1477
1 Nov 2007
Balg F Boileau P

There is no simple method available to identify patients who will develop recurrent instability after an arthroscopic Bankart procedure and who would be better served by an open operation. We carried out a prospective case-control study of 131 consecutive unselected patients with recurrent anterior shoulder instability who underwent this procedure using suture anchors. At follow-up after a mean of 31.2 months (24 to 52) 19 (14.5%) had recurrent instability. The following risk factors were identified: patient age under 20 years at the time of surgery; involvement in competitive or contact sports or those involving forced overhead activity; shoulder hyperlaxity; a Hill-Sachs lesion present on an anteroposterior radiograph of the shoulder in external rotation and/or loss of the sclerotic inferior glenoid contour. These factors were integrated in a 10-point pre-operative instability severity index score and tested retrospectively on the same population. Patients with a score over 6 points had an unacceptable recurrence risk of 70% (p < 0.001). On this basis we believe that an arthroscopic Bankart repair is contraindicated in these patients, to whom we now suggest a Bristow-Latarjet procedure instead


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1335 - 1340
1 Oct 2009
Kontakis GM Tosounidis TI Christoforakis Z Hadjipavlou AG

We reviewed the outcome of 28 patients who had been treated using the Aequalis fracture prosthesis for an acute fracture of the proximal humerus at a mean follow-up of 39.3 months (24 to 63). The mean age of the patients at the time of the fracture was 66.3 years (38 to 80). The mean Constant score was 68.2 (37 to 84) for the operated shoulder, which represented 89.5% of the mean score for the uninjured side (p < 0.001). The quality of the reconstruction as shown on the immediate post-operative radiographs was categorised into three types, anatomical, acceptable, and unacceptable, depending on the position of the tuberosities relative to the prosthetic head and the humeral shaft. Anatomical reconstruction was associated with a higher mean Constant score as well as higher mean values of anterior forward elevation, abduction and external rotation than the other types, but the differences were not statistically significant (p > 0.231). A total of 18 patients had active anterior elevation ≥150°. Their mean active abduction and external rotation were 163.6° and 31.3°, respectively. In seven of the 28 patients, the mean active anterior elevation, abduction and external rotation were 130.7°, 129.2° and 22.8°, respectively. In all, 12 patients were very satisfied with the results, 12 were satisfied, two were dissatisfied and two were disappointed; 26 reported no or only mild pain while only two had moderate pain. In five patients proximal migration of the humeral head was shown on the anteroposterior radiographs of the shoulder. No evidence of loosening was found in any prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 416 - 419
1 Apr 2000
Kido T Itoi E Konno N Sano A Urayama M Sato K

We investigated the function of biceps in 18 patients (19 shoulders) with lesions of the rotator cuff. Their mean age was 59 years. Another series of 18 patients (19 shoulders) with normal rotator cuffs as seen on MRI acted as a control group. Their mean age was 55 years. A brace was used to maintain contraction of biceps during elevation. Anteroposterior radiographs were obtained with the arm elevated at 0°, 45° and 90° with and without contraction of biceps. The distance between the centre of the head of the humerus and the glenoid was compared in the two groups. We found that in the group with tears there was significantly greater proximal migration of the head of the humerus at 0° and 45° of elevation without contraction of biceps but depression of the head of the humerus at 0°, 45° and 90° when biceps was functioning. We conclude that biceps is an active depressor of the head of the humerus in shoulders with lesions of the rotator cuff


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 83 - 87
1 Jan 2002
Nagels J Valstar ER Stokdijk M Rozing PM

The incidence of loosening of a cemented glenoid componentin total shoulder arthroplasty, detected by means of radiolucent lines or positional shift of the component on true anteroposterior radiographs, has been reported to be between 0% and 44%. Radiolucent lines are, however, difficult to detect and to interpret because of the mobility of the shoulder girdle and the obliquity of the glenoid which hinder standardisation of radiographs. We examined radiolucencies around cemented glenoid components in 48 patients, with a mean follow-up of 5.3 years, and found progressive changes to be present predominantly at the inferior pole of the component. This may hold a clue for the mechanism of loosening of this implant. In five patients we performed an additional analysis of loosening of the glenoid component using digital roentgen stereophotogrammetric analysis (RSA). After three years, three of the five implants had loosened (migration 1.2 to 5.5 mm). In only one, with gross loosening, were the radiological signs consistent with the RSA findings. When traditional radiographs are used for assessment, the rate of early loosening is underestimated. We recommend that RSA be used for this


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1403 - 1409
1 Oct 2010
Pape G Zeifang F Bruckner T Raiss P Rickert M Loew M

Fractures of the proximal humerus can lead to malalignment of the humeral head, necrosis and post-traumatic osteoarthritis. In such cases surface replacement might be a promising option.

A total of 28 shoulders with glenohumeral arthritis subsequent to a fracture underwent surface replacement arthroplasty of the humeral head in patients with a mean age of 60 years (35 to 83). On the basis of the inclination of the impacted head, post-traumatic arthritis was divided into three types: type 1, an impacted fracture of the head in an anatomical position (seven cases); type 2, a valgus impacted fracture (13 cases); type 3, a varus impacted fracture (eight cases). The outcome was measured by means of the Constant score.

According to the Boileau classification of the sequelae of fractures of the proximal humerus, all 28 patients had a final result of intra-capsular category 1. The mean Constant score for the 28 shoulders increased from 23.2 points (2 to 45) pre-operatively to 55.1 points (20 to 89) at a mean of 31 months (24 to 66) post-operatively. Valgus impacted fractures had significantly better results (p < 0.039).

Surface replacement arthroplasty can provide good results for patients with post-traumatic osteoarthritis of the shoulder. Their use avoids post-operative complications of the humeral shaft, such as peri-prosthetic fractures. Further surgery can be undertaken more easily as the bone stock is preserved.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1329 - 1335
1 Oct 2007
Lunn JV Castellanos-Rosas J Walch G

We retrospectively identified 18 consecutive patients with synovial chrondromatosis of the shoulder who had arthroscopic treatment between 1989 and 2004. Of these, 15 were available for review at a mean follow-up of 5.3 years (2.3 to 16.5). There were seven patients with primary synovial chondromatosis, but for the remainder, the condition was a result of secondary causes. The mean Constant score showed that pain and activities of daily living were the most affected categories, being only 57% and 65% of the values of the normal side. Surgery resulted in a significant improvement in the mean Constant score in these domains from 8.9 (4 to 15) to 11.3 (2 to 15) and from 12.9 (5 to 20) to 18.7 (11 to 20), respectively (unpaired t-test, p = 0.04 and p < 0.0001, respectively). Movement and strength were not significantly affected. Osteoarthritis was present in eight patients at presentation and in 11 at the final review. Recurrence of the disease with new loose bodies occurred in two patients from the primary group at an interval of three and 12 years post-operatively. In nine patients, loose bodies were also present in the bicipital groove; seven of these underwent an open bicipital debridement and tenodesis.

We found that arthroscopic debridement of the glenohumeral joint and open debridement and tenodesis of the long head of biceps, when indicated, are safe and effective in relieving symptoms at medium-term review.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1382 - 1389
1 Oct 2012
Sewell MD Kang SN Al-Hadithy N Higgs DS Bayley I Falworth M Lambert SM

There is little information about the management of peri-prosthetic fracture of the humerus after total shoulder replacement (TSR). This is a retrospective review of 22 patients who underwent a revision of their original shoulder replacement for peri-prosthetic fracture of the humerus with bone loss and/or loose components. There were 20 women and two men with a mean age of 75 years (61 to 90) and a mean follow-up 42 months (12 to 91): 16 of these had undergone a previous revision TSR. Of the 22 patients, 12 were treated with a long-stemmed humeral component that bypassed the fracture. All their fractures united after a mean of 27 weeks (13 to 94). Eight patients underwent resection of the proximal humerus with endoprosthetic replacement to the level of the fracture. Two patients were managed with a clam-shell prosthesis that retained the original components. The mean Oxford shoulder score (OSS) of the original TSRs before peri-prosthetic fracture was 33 (14 to 48). The mean OSS after revision for fracture was 25 (9 to 31). Kaplan-Meier survival using re-intervention for any reason as the endpoint was 91% (95% confidence interval (CI) 68 to 98) and 60% (95% CI 30 to 80) at one and five years, respectively.

There were two revisions for dislocation of the humeral head, one open reduction for modular humeral component dissociation, one internal fixation for nonunion, one trimming of a prominent screw and one re-cementation for aseptic loosening complicated by infection, ultimately requiring excision arthroplasty. Two patients sustained nerve palsies.

Revision TSR after a peri-prosthetic humeral fracture associated with bone loss and/or loose components is a salvage procedure that can provide a stable platform for elbow and hand function. Good rates of union can be achieved using a stem that bypasses the fracture. There is a high rate of complications and function is not as good as with the original replacement.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 664 - 667
1 May 2013
Rashid A Christofi T Thomas M

Lateral clavicular physeal injuries in adolescents are frequently misinterpreted as acromioclavicular dislocations. There are currently no clear guidelines for the management of these relatively rare injuries. Non-operative treatment can result in a cosmetic deformity, warranting resection of the non-remodelled original lateral clavicle. However, fixation with Kirschner (K)-wires may be associated with infection and/or prominent metalwork. We report our experience with a small series of such cases.

Between October 2008 and October 2011 five patients with lateral clavicular physeal fractures (types III, IV and V) presented to our unit. There were four boys and one girl with a mean age of 12.8 years (9 to 14). Four fractures were significantly displaced and treated operatively using a tension band suture technique. One grade III fracture was treated conservatively. The mean follow-up was 26 months (6 to 42).

All patients made an uncomplicated recovery. The mean time to discharge was three months. The QuickDASH score at follow-up was 0 for each patient. No patient developed subsequent growth disturbances.

We advocate the surgical treatment of significantly displaced Grade IV and V fractures to avoid cosmetic deformity. A tension band suture technique avoids the problems of retained metalwork and the need for a secondary procedure. Excellent clinical and radiological results were seen in all our patients.

Cite this article: Bone Joint J 2013;95-B:664–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1615 - 1619
1 Dec 2007
Piskin A Tomak Y Sen C Tomak L

Cubitus varus and valgus are the most common complications of supracondylar and lateral condylar fractures. Various combinations of osteotomy and fixation have been described to correct these deformities but each is associated with significant complications. In this study, we used distraction osteogenesis and Ilizarov frame fixation to treat 24 elbows in 23 patients with cubitus varus or valgus. Their clinical outcome was evaluated using the protocol of Bellemore et al. The mean time to follow-up was 18.3 months (10 to 36) and the mean time to frame removal was 13.5 weeks (8 to 20). The mean carrying angle was corrected from −18.7° (−10° to −30°) to 6.1° (2° to 10°) in patients with cubitus varus and from 36.5° (25° to 45°) to 9.4° (4° to 15°) in patients with cubitus valgus. There were 18 excellent and six good results.

The Ilizarov method with gradual distraction is a safe, stable, adjustable and versatile method of treating deformities at the elbow without the problems of an unsightly scar or limited range of movement, and gives a good clinical and radiological outcome. Tardy ulnar nerve palsy should be treated first by anterior transposition.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 460 - 465
1 Apr 2008
Strickland JP Sperling JW Cofield RH

While frequently discussed as a standard treatment for the management of an infected shoulder replacement, there is little information on the outcome of two-stage re-implantation.

We examined the outcome of 17 consecutive patients (19 shoulders) who were treated between 1995 and 2004 with a two-stage re-implantation for the treatment of a deep-infection after shoulder replacement. All 19 shoulders were followed for a minimum of two years or until the time of further revision surgery. The mean clinical follow-up was for 35 months (24 to 80). The mean radiological follow-up was 27 months (7 to 80). There were two excellent results, four satisfactory and 13 unsatisfactory. In 12 of the 19 shoulders (63%) infection was considered to be eradicated. The mean pain score improved from 4.2 (3 to 5 (out of 5)) to 1.8 (1 to 4). The mean elevation improved from 42° (0° to 140°) to 89° (0° to 165°), mean external rotation from 30° (0° to 90°) to 43° (0° to 90°), and mean internal rotation from the sacrum to L5. There were 14 complications.

Our study suggests that two-stage re-implantation for an infected shoulder replacement is associated with a high rate of unsatisfactory results, marginal success at eradicating infection and a high complication rate.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 194 - 199
1 Feb 2008
Sosna A Pokorny D Hromádka R Jahoda D Barták V Pinskerová V

The results of proximal humeral replacement following trauma are substantially worse than for osteoarthritis or rheumatoid arthritis. The stable reattachment of the lesser and greater tuberosity fragments to the rotator cuff and the restoration of shoulder biomechanics are difficult. In 1992 we developed a prosthesis designed to improve fixation of the tuberosity fragments in comminuted fractures of the proximal humerus. The implant enables fixation of the fragments to the shaft of the prosthesis and the diaphyseal fragment using screws, washers and a special toothed plate. Between 1992 and 2003 we used this technique in 50 of 76 patients referred to our institution for shoulder reconstruction after trauma. In the remaining 26, reconstruction with a prosthesis and nonabsorbable sutures was performed, as the tuberosity fragments were too small and too severely damaged to allow the use of screws and the toothed plate.

The Constant score two years post-operatively was a mean of 12 points better in the acute trauma group and 11 points better in the late post-traumatic group than in the classical suture group.

We recommend this technique in patients where the tuberosity fragments are large enough to allow fixation with screws, washers and a toothed plate.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 935 - 941
1 Jul 2013
Moor BK Bouaicha S Rothenfluh DA Sukthankar A Gerber C

We hypothesised that a large acromial cover with an upwardly tilted glenoid fossa would be associated with degenerative rotator cuff tears (RCTs), and conversely, that a short acromion with an inferiorly inclined glenoid would be associated with glenohumeral osteoarthritis (OA). This hypothesis was tested using a new radiological parameter, the critical shoulder angle (CSA), which combines the measurements of inclination of the glenoid and the lateral extension of the acromion (the acromion index).

The CSA was measured on standardised radiographs of three groups: 1) a control group of 94 asymptomatic shoulders with normal rotator cuffs and no OA; 2) a group of 102 shoulders with MRI-documented full-thickness RCTs without OA; and 3) a group of 102 shoulders with primary OA and no RCTs noted during total shoulder replacement. The mean CSA was 33.1° (26.8° to 38.6°) in the control group, 38.0° (29.5° to 43.5°) in the RCT group and 28.1° (18.6° to 35.8°) in the OA group. Of patients with a CSA > 35°, 84% were in the RCT group and of those with a CSA < 30°, 93% were in the OA group.

We therefore concluded that primary glenohumeral OA is associated with significantly smaller degenerative RCTs with significantly larger CSAs than asymptomatic shoulders without these pathologies. These findings suggest that individual quantitative anatomy may imply biomechanics that are likely to induce specific types of degenerative joint disorders.

Cite this article: Bone Joint J 2013;95-B:935–41.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 668 - 672
1 May 2013
Abdel MP Hattrup SJ Sperling JW Cofield RH Kreofsky CR Sanchez-Sotelo J

Instability after arthroplasty of the shoulder is difficult to correct surgically. Soft-tissue procedures and revision surgery using unconstrained anatomical components are associated with a high rate of failure. The purpose of this study was to determine the results of revision of an unstable anatomical shoulder arthroplasty to a reverse design prosthesis. Between 2004 and 2007, 33 unstable anatomical shoulder arthroplasties were revised to a reverse design. The mean age of the patients was 71 years (53 to 86) and their mean follow-up was 42 months (25 to 71). The mean time to revision was 26 months (4 to 164). Pain scores improved significantly (pre-operative visual analogue scale (VAS) of 7.2 (sd 1.6); most recent VAS 2.2 (sd 1.9); p = 0.001). There was a statistically significant increase in mean active forward elevation from 40.2° (sd 27.3) to 97.0° (sd 36.2) (p = 0.001). There was no significant difference in internal (p = 0.93) or external rotation (p = 0.40). Radiological findings included notching in five shoulders (15%) and heterotopic ossification of the inferior capsular region in three (9%). At the last follow-up 31 shoulders (94%) were stable. The remaining two shoulders dislocated at 2.5 weeks and three months post-operatively, respectively. According to the Neer rating system, there were 13 excellent (40%), ten satisfactory (30%) and ten unsatisfactory results (30%). Revision of hemiarthroplasty or anatomical total shoulder replacement for instability using a reverse design prosthesis gives good short-term results.

Cite this article: Bone Joint J 2013;95-B:668–72.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1260 - 1264
1 Sep 2012
Raiss P Lin A Mizuno N Melis B Walch G

A total of 12 epileptic patients (14 shoulders) with recurrent seizures and anterior dislocations of the shoulder underwent a Latarjet procedure and were reviewed at a mean of 8.3 years (1 to 20) post-operatively. Mean forward flexion decreased from 165° (100° to 180°) to 160° (90° to 180°) (p = 0.5) and mean external rotation from 54° (10° to 90°) to 43° (5° to 75°) (p = 0.058). The mean Rowe score was 76 (35 to 100) at the final follow-up. Radiologically, all shoulders showed a glenoid-rim defect and Hill-Sachs lesions pre-operatively. Osteo-arthritic changes of the glenohumeral joint were observed in five shoulders (36%) pre-operatively and in eight shoulders (57%) post-operatively. Re-dislocation during a seizure occurred in six shoulders (43%). Five of these patients underwent revision surgery using a bone buttress from the iliac crest and two of these patients re-dislocated due to a new seizure.

Due to the unacceptably high rate of re-dislocation after surgery in these patients, the most important means of reducing the incidence of further dislocation is the medical management of the seizures. The Latarjet procedure should be reserved for the well-controlled patient with epilepsy who has recurrent anterior dislocation of the shoulder during activities of daily living.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 721 - 731
1 Jun 2013
Sewell MD Al-Hadithy N Le Leu A Lambert SM

The sternoclavicular joint (SCJ) is a pivotal articulation in the linked system of the upper limb girdle, providing load-bearing in compression while resisting displacement in tension or distraction at the manubrium sterni. The SCJ and acromioclavicular joint (ACJ) both have a small surface area of contact protected by an intra-articular fibrocartilaginous disc and are supported by strong extrinsic and intrinsic capsular ligaments. The function of load-sharing in the upper limb by bulky periscapular and thoracobrachial muscles is extremely important to the longevity of both joints. Ligamentous and capsular laxity changes with age, exposing both joints to greater strain, which may explain the rising incidence of arthritis in both with age. The incidence of arthritis in the SCJ is less than that in the ACJ, suggesting that the extrinsic ligaments of the SCJ provide greater stability than the coracoclavicular ligaments of the ACJ.

Instability of the SCJ is rare and can be difficult to distinguish from medial clavicular physeal or metaphyseal fracture-separation: cross-sectional imaging is often required. The distinction is important because the treatment options and outcomes of treatment are dissimilar, whereas the treatment and outcomes of ACJ separation and fracture of the lateral clavicle can be similar. Proper recognition and treatment of traumatic instability is vital as these injuries may be life-threatening. Instability of the SCJ does not always require surgical intervention. An accurate diagnosis is required before surgery can be considered, and we recommend the use of the Stanmore instability triangle. Most poor outcomes result from a failure to recognise the underlying pathology.

There is a natural reluctance for orthopaedic surgeons to operate in this area owing to unfamiliarity with, and the close proximity of, the related vascular structures, but the interposed sternohyoid and sternothyroid muscles are rarely injured and provide a clear boundary to the medial retroclavicular space, as well as an anatomical barrier to unsafe intervention.

This review presents current concepts of instability of the SCJ, describes the relevant surgical anatomy, provides a framework for diagnosis and management, including physiotherapy, and discusses the technical challenges of operative intervention.

Cite this article: Bone Joint J 2013;95-B:721–31.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 336 - 342
1 Mar 2008
Cuff DJ Virani NA Levy J Frankle MA Derasari A Hines B Pupello DR Cancio M Mighell M

We retrospectively reviewed 21 patients (22 shoulders) who presented with deep infection after surgery to the shoulder, 17 having previously undergone hemiarthroplasty and five open repair of the rotator cuff. Nine shoulders had undergone previous surgical attempts to eradicate their infection. The diagnosis of infection was based on a combination of clinical suspicion (16 shoulders), positive frozen sections (> 5 polymorphonuclear leukocytes per high-power field) at the time of revision (15 shoulders), positive intra-operative cultures (18 shoulders) or the pre-operative radiological appearances. The patients were treated by an extensive debridement, intravenous antibiotics, and conversion to a reverse shoulder prosthesis in either a single- (10 shoulders) or a two-stage (12 shoulders) procedure.

At a mean follow-up of 43 months (25 to 66) there was no evidence of recurrent infection. All outcome measures showed statistically significant improvements. Mean abduction improved from 36.1° (sd 27.8) pre-operatively to 75.7° (sd 36.0) (p < 0.0001), the mean forward flexion from 43.1° (sd 33.5) to 79.5° (sd 43.2) (p = 0.0003), and mean external rotation from 10.2° (sd 18.7) to 25.4° (sd 23.5) (p = 0.0037). There was no statistically significant difference in any outcome between the single-stage and the two-stage group.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1341 - 1346
1 Oct 2006
Gille J Ince A González O Katzer A Loehr JF

This study reviews the predisposing features, the clinical, and laboratory findings at the time of diagnosis and the results of single-stage revision of prosthetic replacement of the elbow for infection.

Deep infection occurred in six of 305 (1.9%) primary total elbow replacements. The mean follow-up after revision was 6.8 years (6 months to 16 years) and the mean age at the time of revision was 62.7 years (56 to 74). All six cases with infection had rheumatoid arthritis and had received steroid therapy. The infective organism was Staphylococcus aureus. Four of the six elbows had a developed radiolucency around one component or the other. Successful single-stage exchange arthroplasty was carried out with antibiotic-loaded cement in five of the six cases. In one, the revision prosthesis had to be removed following recurrence of the infection. The functional result was good in three elbows, fair in one, poor in one and fair in the resection arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 932 - 936
1 Jul 2011
Mahmoud M Koptan W

Ununited fractures of the scaphoid with extensive bone resorption are usually treated by bone grafting and internal fixation, using either an open or a minimally invasive technique. We studied the feasibility of percutaneous fixation without bone grafting in a consecutive series of 27 patients with established nonunion of an undisplaced fracture of the scaphoid and extensive local resorption of bone. They were treated by a single surgeon with rigid fixation alone, using a headless cannulated screw inserted through a volar percutaneous technique. Clinical examination, standard radiographs and CT confirmed that the fracture had united in all patients at a mean of 11.6 weeks (8 to 16), and that their functional scores had improved.

We concluded that extensive resorption at the fracture site is not an absolute indication for bone grafting, and that percutaneous fixation alone will eventually produce healing of ununited undisplaced fractures of the scaphoid regardless of the size of the gap.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 78 - 83
1 Jan 2006
Sneftrup SB Jensen SL Johannsen HV Søjbjerg JO

We studied retrospectively the results of revision arthroplasty of the elbow using a linked Coonrad-Morrey implant in 23 patients (24 elbows) after a mean follow-up period of 55 months. According to the Mayo Elbow Performance Score, 19 elbows were satisfactory, nine were excellent and ten good. The median total score had improved from 35 points (20 to 75) before the primary arthroplasty to 85 points (40 to 100) at the latest follow-up. There was a marked relief of pain, but the range of movement showed no overall improvement. Two patients had a second revision because of infection and two for aseptic loosening. The estimated five-year survival rate of the prosthesis was 83.1% (95% confidence interval 61.1 to 93.3). Revision elbow arthroplasty using the Coonrad-Morrey implant provided satisfactory results but with complications occurring in 13 cases.