Aims. The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires. Patients and Methods. This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications. Results. Overall, 151/290 of patients (52%) completed the six months of follow-up, leaving 83 patients in the single-wire group and 68 patients in the dual-wire group. In the modified intention-to-treat analysis set, mean DASH scores six months after surgery were 3.8 (. sd. 7.0) and 4.4 (. sd. 9.4), respectively. With multiple imputation (n = 288), mean DASH scores were estimated at 6.3 (. sd. 8.7) and 7.0 (. sd. 10.0).
The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.Aims
Methods
The aim of this study was to assess and compare active rotation of the forearm in normal subjects after the application of a short-arm cast (SAC) in the semisupination position and a long-arm cast (LAC) in the neutral position. A clinical study was also conducted to compare the functional outcomes of using a SAC in the semisupination position with those of using a LAC in the neutral position in patients who underwent arthroscopic triangular fibrocartilage complex (TFCC) foveal repair. A total of 40 healthy right-handed volunteers were recruited. Active pronation and supination of the forearm were measured in each subject using a goniometer. In the retrospective clinical study, 40 patients who underwent arthroscopic foveal repair were included. The wrist was immobilized postoperatively using a SAC in the semisupination position (approximately 45°) in 16 patients and a LAC in 24. Clinical outcomes were assessed using grip strength and patient-reported outcomes. The degree of disability caused by cast immobilization was also evaluated when the cast was removed.Aims
Methods
In the UK, fasciectomy for Dupuytren’s contracture is generally performed under general or regional anaesthetic, with an arm tourniquet and in a hospital setting. We have changed our practice to use local anaesthetic with adrenaline, no arm tourniquet, and perform the surgery in a community setting. We present the outcome of a consecutive series of 30 patients. Prospective data were collected for 30 patients undergoing open fasciectomy on 36 digits (six having two digits affected), over a one-year period and under the care of two surgeons. In total, 10 ml to 20 ml volume of 1% lidocaine with 1:100,000 adrenaline was used. A standard postoperative rehabilitation regime was used. Preoperative health scores, goniometer measurements of metacarpophalangeal (MCP), proximal interphalangeal (PIP) contractures, and Unité Rheumatologique des Affections de la Main (URAM) scores were measured pre- and postoperatively at six and 12 weeks.Aims
Methods
We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves.Aims
Methods
The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging. A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.Aims
Methods
Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture. Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The observers were asked to determine the presence of a scaphoid or other fracture and to classify the scaphoid fracture based on the Herbert classification system. Fleiss kappa statistics were used to calculate the interobserver agreement for the diagnosis of a fracture. Intraclass correlation coefficients (ICCs) were used to assess the agreement for the classification of scaphoid fracture.Aims
Methods
The aims of this study were: firstly, to investigate the influence
of the thickness of cartilage at the sigmoid notch on the inclination
of the distal radioulnar joint (DRUJ), and secondly, to compare
the sensitivity and specificity of MRI with plain radiographs for
the assessment of the inclination of the articular surface of the
DRUJ in the coronal plane. Contemporaneous MRI images and radiographs of 100 wrists from
98 asymptomatic patients (mean age 43 years, (16 to 67); 52 male,
53%) with no history of a fracture involving the wrist or surgery
to the wrist, were reviewed. The thickness of the cartilage at the
sigmoid notch, inclination of the DRUJ and Tolat Type of each DRUJ
were determined. Aims
Patients and Methods
Our purpose was to determine the quality of current randomised
controlled trials (RCTs) in hand surgery using standardised metrics. Based on five-year mean impact factors, we selected the six journals
that routinely publish studies of upper extremity surgery. Using
a journal-specific search query, 62 RCTs met our inclusion criteria.
Then three blinded reviewers used the Jadad and revised Coleman Methodology
Score (RCMS) to assess the quality of the manuscripts.Aims
Materials and Methods
We compared the ceiling effects of two patient-rating
scores, the Disability of the Arm, Shoulder and Hand (DASH) and
Patient-Rated Wrist Evaluation (PRWE), and a physician-rating score,
the Modified Mayo Wrist Score (MMWS) in assessing the outcome of
surgical treatment of an unstable distal radial fracture. A total
of 77 women with a mean age of 64.2 years (50 to 88) who underwent
fixation using a volar locking plate for an unstable distal radial fracture
between 2011 and 2013 were enrolled in this study. All completed
the DASH and PRWE questionnaires one year post-operatively and were
assessed using the MMWS by the senior author. The ceiling effects
in the outcome data assessed for each score were estimated. The data assessed with both patient-rating scores, the DASH and
PRWE, showed substantial ceiling effects, whereas the data assessed
with MMWS showed no ceiling effect. Researchers should be aware of a possible ceiling effect in the
assessment of the outcome of the surgical treatment of distal radial
fractures using patient-rating scores. It could also increase the
likelihood of a type II error. Cite this article:
Arthritis of the wrist is a painful disabling
condition that has various causes and presentations. The traditional treatment
has been a total wrist fusion at a price of the elimination of movement.
However, forms of treatment which allow the preservation of movement
are now preferred. Modern arthroplasties of the wrist are still
not sufficiently robust to meet the demands of many patients, nor
do they restore normal kinematics of the wrist. A preferable compromise
may be selective excision and partial fusion of the wrist using
knowledge of the aetiology and pattern of degenerative change to
identify which joints can be sacrificed and which can be preserved. This article provides an overview of the treatment options available
for patients with arthritis of the wrist and an algorithm for selecting
an appropriate surgical strategy. Cite this article:
Damage to the cartilage of the distal radioulnar
joint frequently leads to pain and limitation of movement, therefore repair
of this joint cartilage would be highly desirable. The purpose of
this study was to investigate the fixation of scaffold in cartilage
defects of this joint as part of matrix-assisted regenerative autologous
cartilage techniques. Two techniques of fixation of collagen scaffolds,
one involving fibrin glue alone and one with fibrin glue and sutures, were
compared in artificially created cartilage defects of the distal
radioulnar joint in a human cadaver. After being subjected to continuous
passive rotation, the methods of fixation were evaluated for cover
of the defect and pull out force. No statistically significant differences were found between the
two techniques for either cover of the defect or integrity of the
scaffold. However, a significantly increased mean pull out force
was found for the combined procedure, 0.665 N (0.150 to 1.160) This suggests that although successful fixation of a collagen
type I/III scaffold in a distal radioulnar joint cartilage defect
is feasible with both forms of fixation, fixation with glue and
sutures is preferable. Cite this article:
We report a new surgical technique of open carpal
tunnel release with subneural reconstruction of the transverse carpal
ligament and compare this with isolated open and endoscopic carpal
tunnel release. Between December 2007 and October 2011, 213 patients with carpal
tunnel syndrome (70 male, 143 female; mean age 45.6 years; 29 to
67) were recruited from three different centres and were randomly
allocated to three groups: group A, open carpal tunnel release with
subneural reconstruction of the transverse carpal ligament (n =
68); group B, isolated open carpal tunnel release (n = 92); and
group C, endoscopic carpal tunnel release (n = 53). At a mean final follow-up of 24 months (22 to 26), we found no
significant difference between the groups in terms of severity of
symptoms or lateral grip strength. Compared with groups B and C,
group A had significantly better functional status, cylindrical
grip strength and pinch grip strength. There were significant differences
in Michigan Hand Outcome scores between groups A and B, A and C,
and B and C. Group A had the best functional status, cylindrical
grip strength, pinch grip strength and Michigan Hand Outcome score. Subneural reconstruction of the transverse carpal ligament during
carpal tunnel decompression maximises hand strength by stabilising
the transverse carpal arch. Cite this article: