Advertisement for orthosearch.org.uk
Results 1 - 20 of 48
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 3 - 9
1 Jun 2020
Yang J Parvizi J Hansen EN Culvern CN Segreti JC Tan T Hartman CW Sporer SM Della Valle CJ

Aims. The aim of this study was to determine if a three-month course of microorganism-directed oral antibiotics reduces the rate of failure due to further infection following two-stage revision for chronic prosthetic joint infection (PJI) of the hip and knee. Methods. A total of 185 patients undergoing a two-stage revision in seven different centres were prospectively enrolled. Of these patients, 93 were randomized to receive microorganism-directed oral antibiotics for three months following reimplantation; 88 were randomized to receive no antibiotics, and four were withdrawn before randomization. Of the 181 randomized patients, 28 were lost to follow-up, six died before two years follow-up, and five with culture negative infections were excluded. The remaining 142 patients were followed for a mean of 3.3 years (2.0 to 7.6) with failure due to a further infection as the primary endpoint. Patients who were treated with antibiotics were also assessed for their adherence to the medication regime and for side effects to antibiotics. Results. Nine of 72 patients (12.5%) who received antibiotics failed due to further infection compared with 20 of 70 patients (28.6%) who did not receive antibiotics (p = 0.012). Five patients (6.9%) in the treatment group experienced adverse effects related to the administered antibiotics severe enough to warrant discontinuation. Conclusion. This multicentre randomized controlled trial showed that a three-month course of microorganism-directed, oral antibiotics significantly reduced the rate of failure due to further infection following a two-stage revision of total hip or knee arthroplasty for chronic PJI. Cite this article: Bone Joint J 2020;102-B(6 Supple A):3–9


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 171 - 174
1 Feb 2005
Hoad-Reddick DA Evans CR Norman P Stockley I

All major studies have incorporated the use of prolonged courses of parenteral or oral antibiotic therapy in the management of two-stage revision of an infected total knee arthroplasty. We present a series of 59 consecutive patients, all with microbiologically-proven deep infection of a total knee arthroplasty, in whom a prolonged course of antibiotic therapy was not routinely used. The mean follow-up was 56.4 months (24 to 114). Of the 38 patients who underwent a staged exchange, infection was successfully eradicated in 34 (89%) but recurrent or persistent infection was present in four (11%). Our rate of cure for infection is similar to that reported elsewhere. We conclude that a prolonged course of antibiotic therapy seems not to alter the incidence of recurrent or persistent infection. The costs of the administration of antibiotics are high and such a regime may be unnecessary


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 123 - 125
1 Nov 2012
Munro JT Garbuz DS Masri BA Duncan CP

Antibiotic impregnated articulating spacers are used in two-stage revision total knee arthroplasty to deliver local antibiotic therapy while preserving function. We have observed infection control in greater than 95% of cases with functional outcomes approaching those seen in revision for aseptic loosening. Higher failure has been observed with methicillin resistant organisms.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1373 - 1379
1 Aug 2021
Matar HE Bloch BV Snape SE James PJ

Aims. Single-stage revision total knee arthroplasty (rTKA) is gaining popularity in treating chronic periprosthetic joint infections (PJIs). We have introduced this approach to our clinical practice and sought to evaluate rates of reinfection and re-revision, along with predictors of failure of both single- and two-stage rTKA for chronic PJI. Methods. A retrospective comparative cohort study of all rTKAs for chronic PJI between 1 April 2003 and 31 December 2018 was undertaken using prospective databases. Patients with acute infections were excluded; rTKAs were classified as single-stage, stage 1, or stage 2 of two-stage revision. The primary outcome measure was failure to eradicate or recurrent infection. Variables evaluated for failure by regression analysis included age, BMI, American Society of Anesthesiologists grade, infecting organisms, and the presence of a sinus. Patient survivorship was also compared between the groups. Results. A total of 292 consecutive first-time rTKAs for chronic PJI were included: 82 single-stage (28.1%); and 210 two-stage (71.9%) revisions. The mean age was 71 years (27 to 90), with 165 females (57.4%), and a mean BMI of 30.9 kg/m. 2. (20 to 53). Significantly more patients with a known infecting organism were in the single-stage group (93.9% vs 80.47%; p = 0.004). The infecting organism was identified preoperatively in 246 cases (84.2%). At a mean follow-up of 6.3 years (2.0 to 17.6), the failure rate was 6.1% in the single-stage, and 12% in the two-stage groups. All failures occurred within four years of treatment. The presence of a sinus was an independent risk factor for failure (odds ratio (OR) 4.97; 95% confidence interval (CI) 1.593 to 15.505; p = 0.006), as well as age > 80 years (OR 5.962; 95% CI 1.156 to 30.73; p = 0.033). The ten-year patient survivorship rate was 72% in the single-stage group compared with 70.5% in the two-stage group. This difference was not significant (p = 0.517). Conclusion. Single-stage rTKA is an effective strategy with a high success rate comparable to two-stage approach in appropriately selected patients. Cite this article: Bone Joint J 2021;103-B(8):1373–1379


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 807 - 812
1 Aug 2000
Haddad FS Masri BA Campbell D McGraw RW Beauchamp CP Duncan CP

The PROSTALAC functional spacer is made of antibiotic-loaded acrylic cement but has a small metal-on-polythene articular surface. We have used it as an interim spacer in two-stage exchange arthroplasty for infected total knee replacement. PROSTALAC allows continuous rehabilitation between stages as it maintains good alignment and stability of the knee and a reasonable range of movement. It also helps to maintain the soft-tissue planes, which facilitates the second-stage procedure.

We reviewed 45 consecutive patients, treated over a period of nine years. The mean follow-up was for 48 months (20 to 112). At final review, there was no evidence of infection in 41 patients (91%); only one had a recurrent infection with the same organism. There was improvement in the Hospital for Special Surgery knee score between stages and at final review. The range of movement was maintained between stages. Complications were primarily related to the extensor mechanism and stability of the knee between stages. Both of these problems decreased with refinement of the design of the implant.

The rate of cure of the infection in our patients was similar to that using other methods. Movement of the knee does not appear to hinder control of infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1011 - 1015
1 Aug 2006
Hart WJ Jones RS

We present a series of 48 patients with infected total knee replacements managed by the use of articulating cement spacers and short-term parenteral antibiotic therapy in the postoperative period. All patients had microbiological and/or histological confirmation of infection at the first stage of their revision. They all underwent re-implantation and had a mean follow-up of 48.5 months (26 to 85).

Infection was successfully eradicated in 42 of the 48 patients (88%). Six had persistent infection which led to recurrence of symptoms and further surgery was successful in eliminating infection in four patients. These rates of success are similar to those of other comparable series. We conclude that protracted courses of intravenous antibiotic treatment may not be necessary in the management of the infected total knee replacement.

In addition, we analysed the microbiological, histological and serological results obtained at the time of re-implantation of the definitive prosthesis, but could not identify a single test which alone would accurately predict a successful outcome.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1286 - 1293
1 Dec 2023
Yang H Cheon J Jung D Seon J

Aims

Fungal periprosthetic joint infections (PJIs) are rare, but their diagnosis and treatment are highly challenging. The purpose of this study was to investigate the clinical outcomes of patients with fungal PJIs treated with two-stage exchange knee arthroplasty combined with prolonged antifungal therapy.

Methods

We reviewed our institutional joint arthroplasty database and identified 41 patients diagnosed with fungal PJIs and treated with two-stage exchange arthroplasty after primary total knee arthroplasty (TKA) between January 2001 and December 2020, and compared them with those who had non-fungal PJIs during the same period. After propensity score matching based on age, sex, BMI, American Society of Anesthesiologists grade, and Charlson Comorbidity Index, 40 patients in each group were successfully matched. The surgical and antimicrobial treatment, patient demographic and clinical characteristics, recurrent infections, survival rates, and relevant risk factors that affected joint survivorship were analyzed. We defined treatment success as a well-functioning arthroplasty without any signs of a PJI, and without antimicrobial suppression, at a minimum follow-up of two years from the time of reimplantation.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 852 - 860
1 Jul 2020
Zamora T Garbuz DS Greidanus NV Masri BA

Aims. Our objective is to describe our early and mid-term results with the use of a new simple primary knee prosthesis as an articulating spacer in planned two-stage management for infected knee arthroplasty. As a second objective, we compared outcomes between the group with a retained first stage and those with a complete two-stage revision. Methods. We included 47 patients (48 knees) with positive criteria for infection, with a minimum two-year follow-up, in which a two-stage approach with an articulating spacer with new implants was used. Patients with infection control, and a stable and functional knee were allowed to retain the initial first-stage components. Outcomes recorded included: infection control rate, reoperations, final range of motion (ROM), and quality of life assessment (QoL) including Western Ontario and McMaster Universities osteoarthritis index, Knee Injury and Osteoarthritis Outcome Score, Oxford Knee Score, 12-Item Short-Form Health Survey questionnaire, and University of California Los Angeles (UCLA) activity score and satisfaction score. These outcomes were evaluated and compared to additional cohorts of patients with retained first-stage interventions and those with a complete two-stage revision. Mean follow-up was 3.7 years (2.0 to 6.5). Results. Eight knees failed directly related to lack of infection control (16%), and two patients (two knees) died within the first year for causes not directly related, giving an initial success rate of 79% (38/48). Secondary success rate after a subsequent procedure was 91% (44/48 knees). From the initially retained spacers, four knees (22%) required a second-stage revision for continuous symptoms and one (5%) for an acute infection. There were no significant differences regarding the failure rate due to infection, ROM, and QoL assessment between patients with a retained first-stage procedure and those who underwent a second-stage operation. Conclusion. Our protocol of two-stage exchange for infected knee arthroplasties with an articulating spacer and using new primary knee implants achieves adequate infection control. Retained first-stage operations achieve comparable results in selected cases, with no difference in infection control, ROM, and QoL assessment in comparison to patients with completed two-stage revision surgery. Cite this article: Bone Joint J 2020;102-B(7):852–860


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 759 - 764
1 Jun 2014
Tibrewal S Malagelada F Jeyaseelan L Posch F Scott G

Peri-prosthetic infection is amongst the most common causes of failure following total knee replacement (TKR). In the presence of established infection, thorough joint debridement and removal of all components is necessary following which new components may be implanted. This can be performed in one or two stages; two-stage revision with placement of an interim antibiotic-loaded spacer is regarded by many to be the standard procedure for eradication of peri-prosthetic joint infection. . We present our experience of a consecutive series of 50 single-stage revision TKRs for established deep infection performed between 1979 and 2010. There were 33 women and 17 men with a mean age at revision of 66.8 years (42 to 84) and a mean follow-up of 10.5 years (2 to 24). The mean time between the primary TKR and the revision procedure was 2.05 years (1 to 8). Only one patient required a further revision for recurrent infection, representing a success rate of 98%. Nine patients required further revision for aseptic loosening, according to microbiological testing of biopsies taken at the subsequent surgery. Three other patients developed a further septic episode but none required another revision. These results suggest that a single-stage revision can produce comparable results to a two-stage revision. Single-stage revision offers a reduction in costs as well as less morbidity and inconvenience for patients. Cite this article: Bone Joint J 2014;96-B:759–64


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims

Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis).

Methods

Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 386 - 393
1 Mar 2022
Neufeld ME Liechti EF Soto F Linke P Busch S Gehrke T Citak M

Aims

The outcome of repeat septic revision after a failed one-stage exchange for periprosthetic joint infection (PJI) in total knee arthroplasty (TKA) remains unknown. The aim of this study was to report the infection-free and all-cause revision-free survival of repeat septic revision after a failed one-stage exchange, and to determine whether the Musculoskeletal Infection Society (MSIS) stage is associated with subsequent infection-related failure.

Methods

We retrospectively reviewed all repeat septic revision TKAs which were undertaken after a failed one-stage exchange between 2004 and 2017. A total of 33 repeat septic revisions (29 one-stage and four two-stage) met the inclusion criteria. The mean follow-up from repeat septic revision was 68.2 months (8.0 months to 16.1 years). The proportion of patients who had a subsequent infection-related failure and all-cause revision was reported and Kaplan-Meier survival for these endpoints was determined. Patients were categorized according to the MSIS staging system, and the association with subsequent infection was analyzed.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 688 - 691
1 Jul 2004
Blom AW Brown J Taylor AH Pattison G Whitehouse S Bannister GC

The aim of our study was to determine the current incidence and outcome of infected total knee arthroplasty (TKA) in our unit comparing them with our earlier audit in 1986, which had revealed infection rates of 4.4% after 471 primary TKAs and 15% after 23 revision TKAs at a mean follow-up of 2.8 years. In the interim we introduced stringent antibiotic prophylaxis, and the routine use of occlusive clothing within vertical laminar flow theatres and 0.05% chlorhexidine lavage during arthroplasty surgery. We followed up 931 primary TKAs and 69 revision TKAs for a mean of 6.5 years (5 to 8). Patients were traced by postal questionnaire, telephone interview or examination of case notes of the deceased. Nine (1%) of the patients who underwent primary TKA, and four (5.8%) of those who underwent revision TKA developed deep infection. Two of nine patients (22.2%) who developed infection after primary TKA were successfully treated without further surgery. All four of the patients who had infection after revision TKA had a poor outcome with one amputation, one chronic discharging sinus and two arthrodeses. Patients who underwent an arthrodesis had comparable Oxford knee scores to those who underwent a two-stage revision. Although infection rates have declined with the introduction of prophylactic measures, and more patients are undergoing TKA, the outcome of infected TKA has improved very little


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 13 - 17
1 Jun 2021
Park KJ Chapleau J Sullivan TC Clyburn TA Incavo SJ

Aims

Infection complicating primary total knee arthroplasty (TKA) is a common reason for revision surgery, hospital readmission, patient morbidity, and mortality. Increasing incidence of methicillin-resistant Staphylococcus aureus (MRSA) is a particular concern. The use of vancomycin as prophylactic agent alone or in combination with cephalosporin has not demonstrated lower periprosthetic joint infection (PJI) rates, partly due to timing and dosing of intravenous (IV) vancomycin administration, which have proven important factors in effectiveness. This is a retrospective review of a consecutive series of primary TKAs examining incidence of PJI, adverse reactions, and complications using IV versus intraosseous (IO) vancomycin at 30-day, 90-day, and one-year follow-up.

Methods

A retrospective review of 1,060 patients who underwent TKA between May 2016 to July 2020 was performed. There were 572 patients in the IV group and 488 in the IO group, with minimal 30 days of follow-up. Patients were followed up at regularly scheduled intervals (two, six, and 12 weeks). No differences between groups for age, sex, BMI, or baseline comorbidities existed. The IV group received an IV dose of 15 mg/kg vancomycin given over an hour preceding skin incision. The IO group received a 500 mg dose of vancomycin mixed in 150 ml of normal saline, injected into proximal tibia after tourniquet inflation, before skin incision. All patients received an additional dose of first generation cephalosporin. Evaluation included preoperative and postoperative serum creatinine values, tourniquet time, and adverse reactions attributable to vancomycin.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 150 - 157
1 Jun 2021
Anderson LA Christie M Blackburn BE Mahan C Earl C Pelt CE Peters CL Gililland J

Aims

Porous metaphyseal cones can be used for fixation in revision total knee arthroplasty (rTKA) and complex TKAs. This metaphyseal fixation has led to some surgeons using shorter cemented stems instead of diaphyseal engaging cementless stems with a potential benefit of ease of obtaining proper alignment without being beholden to the diaphysis. The purpose of this study was to evaluate short term clinical and radiographic outcomes of a series of TKA cases performed using 3D-printed metaphyseal cones.

Methods

A retrospective review of 86 rTKAs and nine complex primary TKAs, with an average age of 63.2 years (SD 8.2) and BMI of 34.0 kg/m2 (SD 8.7), in which metaphyseal cones were used for both femoral and tibial fixation were compared for their knee alignment based on the type of stem used. Overall, 22 knees had cementless stems on both sides, 52 had cemented stems on both sides, and 15 had mixed stems. Postoperative long-standing radiographs were evaluated for coronal and sagittal plane alignment. Adjusted logistic regression models were run to assess malalignment hip-knee-ankle (HKA) alignment beyond ± 3° and sagittal alignment of the tibial and femoral components ± 3° by stem type.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 840 - 845
1 May 2021
Rossi SMP Perticarini L Clocchiatti S Ghiara M Benazzo F

Aims

In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up.

Methods

A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 151 - 157
1 Jun 2020
Gil D Atici AE Connolly RL Hugard S Shuvaev S Wannomae KK Oral E Muratoglu OK

Aims

We propose a state-of-the-art temporary spacer, consisting of a cobalt-chrome (CoCr) femoral component and a gentamicin-eluting ultra-high molecular weight polyethylene (UHMWPE) tibial insert, which can provide therapeutic delivery of gentamicin, while retaining excellent mechanical properties. The proposed implant is designed to replace conventional spacers made from bone cement.

Methods

Gentamicin-loaded UHMWPE was prepared using phase-separated compression moulding, and its drug elution kinetics, antibacterial, mechanical, and wear properties were compared with those of conventional gentamicin-loaded bone cement.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 158 - 164
1 Jun 2021
Hernandez NM Hinton ZW Wu CJ Ryan SP Bolognesi MP

Aims

Tibial cones are often utilized in revision total knee arthroplasty (TKA) with metaphyseal defects. Because there are few studies evaluating mid-term outcomes with a sufficient cohort, the purpose of this study was to evaluate tibial cone survival and complications in revision TKAs with tibial cones at minimum follow-up of five years.

Methods

A retrospective review was completed from September 2006 to March 2015, evaluating 67 revision TKAs (64 patients) that received one specific porous tibial cone during revision TKA. The final cohort was composed of 62 knees (59 patients) with five years of clinical follow-up or reoperation. The mean clinical follow-up of the TKAs with minimum five-year clinical follow-up was 7.6 years (5.0 to 13.3). Survivorship analysis was performed with the endpoints of tibial cone revision for aseptic loosening, tibial cone revision for any reason, and reoperation. We also evaluated periprosthetic joint infection (PJI), risk factors for failure, and performed a radiological review.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 98 - 104
1 Jan 2021
van Ooij B Sierevelt IN van der Vis HM Hoornenborg D Haverkamp D

Aims

For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA.

Methods

A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 123 - 128
1 Jun 2020
Martin JR Geary MB Ransone M Macknet D Fehring K Fehring T

Aims

Aseptic loosening of the tibial component is a frequent cause of failure in primary total knee arthroplasty (TKA). Management options include an isolated tibial revision or full component revision. A full component revision is frequently selected by surgeons unfamiliar with the existing implant or who simply wish to “start again”. This option adds morbidity compared with an isolated tibial revision. While isolated tibial revision has a lower morbidity, it is technically more challenging due to difficulties with exposure and maintaining prosthetic stability. This study was designed to compare these two reconstructive options.

Methods

Patients undergoing revision TKA for isolated aseptic tibial loosening between 2012 and 2017 were identified. Those with revision implants or revised for infection, instability, osteolysis, or femoral component loosening were excluded. A total of 164 patients were included; 88 had an isolated tibial revision and 76 had revision of both components despite only having a loose tibial component. The demographics and clinical and radiological outcomes were recorded.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 170 - 175
1 Jun 2020
Chalmers BP Matrka AK Sems SA Abdel MP Sierra RJ Hanssen AD Pagnano MW Mabry TM Perry KI

Aims

Arthrodesis is rarely used as a salvage procedure for patients with a chronically infected total knee arthroplasty (TKA), and little information is available about the outcome. The aim of this study was to assess the reliability, durability, and safety of this procedure as the definitive treatment for complex, chronically infected TKA, in a current series of patients.

Methods

We retrospectively identified 41 patients (41 TKAs) with a complex infected TKA, who were treated between 2002 and 2016 using a deliberate, two-stage knee arthrodesis. Their mean age was 64 years (34 to 88) and their mean body mass index (BMI) was 39 kg/m2 (25 to 79). The mean follow-up was four years (2 to 9). The extensor mechanism (EM) was deficient in 27 patients (66%) and flap cover was required in 14 (34%). Most patients were host grade B (56%) or C (29%), and limb grade 3 (71%), according to the classification of McPherson et al. A total of 12 patients (29%) had polymicrobial infections and 20 (49%) had multi-drug resistant organisms; fixation involved an intramedullary nail in 25 (61%), an external fixator in ten (24%), and dual plates in six (15%).