Aims. The aim of the study was to analyze the results of primary tendon
reinsertion in acute and chronic distal
Aims. Reconstruction after osteoarticular resection of the proximal ulna for tumours is technically difficult and little has been written about the options that are available. We report a series of four patients who underwent radial neck to humeral trochlea transposition arthroplasty following proximal ulnar osteoarticular resection. Methods. Between July 2020 and July 2022, four patients with primary bone tumours of the ulna underwent radial neck to humeral trochlea transposition arthroplasty. Their mean age was 28 years (12 to 41). The functional outcome was assessed using the range of motion (ROM) of the elbow, rotation of the forearm and stability of the elbow, the Musculoskeletal Tumor Society score (MSTS), and the nine-item abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH-9) score. Results. All patients were available for follow-up at a mean of 33 months (25 to 43) and were disease-free. The mean flexion arc was 0° to 105°. Three patients had complications. One had neuropraxia of the ulnar nerve. The symptoms resolved after three months. In one patient, the screw used for fixation of the
1. Six cases of malunited anterior Monteggia fracture have been treated, five of them successfully, by open reduction and reconstruction of the orbicular ligament by turning down a slip from the
In children cubitus varus is common after malunion of a supracondylar fracture of the humerus. Later problems such as tardy ulnar nerve palsy, snapping of the lateral
Seven children with chronic post-traumatic dislocation of the radial head were treated by open reduction and ligament reconstruction by a
Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered. Cite this article:
The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection. From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.Aims
Methods
The aim of this study was to develop and internally validate a prognostic nomogram to predict the probability of gaining a functional range of motion (ROM ≥ 120°) after open arthrolysis of the elbow in patients with post-traumatic stiffness of the elbow. We developed the Shanghai Prediction Model for Elbow Stiffness Surgical Outcome (SPESSO) based on a dataset of 551 patients who underwent open arthrolysis of the elbow in four institutions. Demographic and clinical characteristics were collected from medical records. The least absolute shrinkage and selection operator regression model was used to optimize the selection of relevant features. Multivariable logistic regression analysis was used to build the SPESSO. Its prediction performance was evaluated using the concordance index (C-index) and a calibration graph. Internal validation was conducted using bootstrapping validation.Aims
Methods
Two cases of unusual snapping at the elbow are described. In both, the medial head of the triceps was found to be separated from the main muscle belly. During flexion of the elbow, the medial head dislocated over the medial epicondyle, producing a characteristic snapping phenomenon. Both cases were of long standing and had been asymptomatic for years. The first clinical symptoms were those of an ulnar neuropathy. In order to restore the normal position of the medial head of the
The aim of this study was to report the mid-term clinical outcome
of cemented unlinked J-alumina ceramic elbow (JACE) arthroplasties
when used in patients with rheumatoid arthritis (RA). We retrospectively reviewed 87 elbows, in 75 patients with RA,
which was replaced using a cemented JACE total elbow arthroplasty
(TEA) between August 2003 and December 2012, with a follow-up of
96%. There were 72 women and three men, with a mean age of 62 years
(35 to 79). The mean follow-up was nine years (2 to 14). The clinical condition
of each elbow before and after surgery was assessed using the Mayo
Elbow Performance Index (MEPI, 0 to 100 points). Radiographic loosening
was defined as a progressive radiolucent line of >1 mm that was
completely circumferential around the prosthesis.Aims
Patients and Methods
To prevent insufficiency of the triceps after
total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar
approach. This study evaluates the clinical results and post-operative
alignment of the prosthesis using this approach. We reviewed 25 elbows in 23 patients. There were five men and
18 women with a mean age of 69 years (54 to 83). There were 18 elbows
with rheumatoid arthritis, six with a fracture or pseudoarthrosis
and one elbow with osteoarthritis. Post-operative complications included one intra-operative fracture,
one elbow with heterotopic ossification, one transient ulnar nerve
palsy, and one elbow with skin necrosis, but no elbow was affected
by insufficiency of the triceps. Patients were followed for a mean of 42 months (24 to 77). The
mean post-operative Japanese Orthopaedic Association Elbow Score
was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8
(65 to 100). The mean post-operative flexion/extension of the elbow
was 135°/-8°. The Manual Muscle Testing score of the triceps was
5 in 23 elbows and 2 in two elbows (one patient). The mean alignment
of the implants examined by 3D-CT was 2.8° pronation (standard deviation
( The triceps-sparing ulnar approach allows satisfactory alignment
of the implants, is effective in preventing post-operative triceps
insufficiency, and gives satisfactory short-term results. Cite this article: 2015;97-B:1096–1101.
In order to achieve satisfactory reduction of
complex distal humeral fractures, adequate exposure of the fracture fragments
and the joint surface is required. Several surgical exposures have
been described for distal humeral fractures. We report our experience
using the anconeus pedicle olecranon flip osteotomy approach. This
involves detachment of the triceps along with a sliver of olecranon,
which retains the anconeus pedicle. We report the use of this approach
in ten patients (six male, four female) with a mean age of 38.4
years (28 to 51). The mean follow-up was 15 months (12 to 18) with
no loss to follow-up. Elbow function was graded using the Mayo Score.
The results were excellent in four patients, good in five and fair
in one patient. The mean time to both fracture and osteotomy union
was 10.6 weeks (8 to 12) and 7.1 weeks (6 to 8), respectively. We
found this approach gave reliably good exposure for these difficult
fractures enabling anatomical reduction and bicondylar plating without
complications. Cite this article:
Treatment of an infected total elbow replacement
(TER) is often successful in eradicating or suppressing the infection.
However, the extensor mechanism may be compromised by both the infection
and the surgery. The goal of this study was to assess triceps function
in patients treated for deep infection complicating a TER. Between
1976 and 2007 a total of 217 TERs in 207 patients were treated for
infection of a TER at our institution. Superficial infections and
those that underwent resection arthroplasty were excluded, leaving
93 TERs. Triceps function was assessed by examination and a questionnaire.
Outcome was measured using the Mayo Elbow Performance Score (MEPS). Triceps weakness was identified in 51 TERs (49 patients, 55%).
At a mean follow-up of five years (0.8 to 34), the extensor mechanism
was intact in 13 patients, with the remaining 38 having bone or
soft-tissue loss. The mean MEPS was 70 points (5 to 100), with a
mean functional score of 18 (0 to 25) of a possible 25 points. Infection following TER can often be eradicated; however, triceps
weakness occurs in more than half of the patients and may represent
a major functional problem. Cite this article:
We report our experience of performing an elbow
hemiarthroplasty in the treatment of comminuted distal humeral fractures
in the elderly patients. A cohort of 42 patients (three men and 39 women, mean age 72;
56 to 84) were reviewed at a mean of 34.3 months (24 to 61) after
surgery. Functional outcome was measured with the Mayo Elbow Performance
Score (MEPS) and range of movement. The disabilities of the arm,
shoulder and hand questionnaire (DASH) was used as a patient rated
evaluation. Complications and ulnar nerve function were recorded.
Plain radiographs were obtained to assess prosthetic loosening,
olecranon wear and heterotopic bone formation. The mean extension deficit was 23.5° (0° to 60°) and mean flexion
was 126.8° (90° to 145°) giving a mean arc of 105.5° (60° to 145°).
The mean MEPS was 90 (50 to 100) and a mean DASH score of 20 (0
to 63). Four patients had additional surgery for limited range of
movement and one for partial instability. One elbow was revised
due to loosening, two patients had sensory ulnar nerve symptoms,
and radiographic signs of mild olecranon wear was noted in five
patients. Elbow hemiarthroplasty for comminuted intra-articular distal
humeral fractures produces reliable medium-term results with functional
outcome and complication rates, comparable with open reduction and
internal fixation and total elbow arthroplasty. Cite this article:
Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when using a tension-band technique to stabilise the bone. Physiological cyclical loading simulating passive elbow movement (15 N) and using the arms to push up from a chair (450 N) were applied using an Instron materials testing machine whilst monitoring the osteotomy site with a video extensometer. Each osteotomy was repaired by one of four materials, namely, Stainless Steel Wire (7), No 2 Ethibond (3), No 5 Ethibond (5), or No 2 FiberWire (7). There were no failures (movement of >
2 mm) with stainless steel wire or FiberWire and no significant difference in the movements measured across the site of the osteotomy (p = 0.99). The No. 2 Ethibond failed at 450 N and two of the five of No. 5 Ethibond sutures had a separation of >
2 mm at 450 N. FiberWire as the tension band in this model held the reduction as effectively as stainless steel wire and may reduce the incidence of discomfort from the hardware. On the basis of our findings we suggest that a clinical trial should be undertaken
We assessed the long-term (more than ten-year) outcomes of the
Kudo type-5 elbow prosthesis in patients with rheumatoid arthritis
(RA). We reviewed 41 elbows (Larsen Grade IV, n = 21; Grade V, n =
20) in 31 patients with RA who had undergone a Kudo type-5 total
elbow arthroplasty (TEA) between 1994 and 2003, and had been followed
up for more than ten years. The humeral component was cementless
and the all-polyethylene ulnar component cemented in every patient. Clinical
outcome was assessed using the Mayo elbow performance score. We
calculated the revision rate and evaluated potential risk factors
for revision. The duration of follow-up was a mean 141 months (120
to 203).Aims
Materials and Methods
We describe a consecutive series of five patients with bone or soft-tissue sarcomas of the elbow and intra-articular extension treated by complex soft tissue, allograft bone and prosthetic joint replacement after wide extra-articular