We evaluated the maturation of grafted bone in
cases of successful fusion after a one- or two-level posterior lumbar interbody
fusion (PLIF) using interbody carbon cages. We carried out a five-year
prospective longitudinal radiological evaluation of patients using
plain radiographs and CT scans. One year after surgery, 117 patients
with an early successful fusion were selected for inclusion in the
study. Radiological evaluation of interbody bone fusion was graded
on a 4-point scale. The mean grades of all radiological and CT assessments
increased in the five years after surgery, and differences compared
to the previous time interval were statistically significant for
three or four years after surgery. Because the grafted bone continues
to mature for three years after surgery, the success of a fusion
should not be assessed until at least three years have elapsed.
There were no significant differences in the longitudinal patterns
of grafted bone maturity between iliac bone and local bone. However,
iliac bone grafting may remodel faster than local bone.
To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time. We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated.Aims
Methods
To assess the extent of osteointegration in two designs of shoulder
resurfacing implants. Bony integration to the Copeland cylindrical
central stem design and the Epoca RH conical-crown design were compared. Implants retrieved from six patients in each group were pair-matched.
Mean time to revision surgery of Copeland implants was 37 months
(standard deviation (Aims
Patients and Methods
In developmental dysplasia of the hip (DDH),
a bone defect is often observed superior to the acetabulum after
the reconstruction at the level of the true acetabulum during total
hip replacement (THR). However, the essential amount of uncemented
acetabular component coverage required for a satisfactory outcome
remains controversial. The purpose of this study was to assess the
stability and function of acetabular components with a lack of coverage >
30% (31% to 50%). A total of 760 DDH patients underwent THR with
acetabular reconstruction at the level of the true floor. Lack of
coverage above the acetabular component of >
30% occurred in 56
patients. Intra-operatively, autogenous morcellised bone grafts
were used to fill the uncovered portion. Other than two screws inserted through
the acetabular shell, no additional structural supports were used
in these hips. In all, four patients were lost to follow-up. Therefore,
52 patients (52 hips, 41 women and 11 men) with a mean age of 60.1
years (42 to 78) were available for this study at a mean of 4.8
years (3 to 7). There were no instances of prosthesis revision or
marked loosening during the follow-up. The Harris hip score improved
from a mean of 40.7 points ( Cite this article: