Aims. Carpal malalignment after a distal radial fracture occurs due to loss of volar
Aims. To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour. Methods. A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared. Results. Patient-Rated Wrist and Hand Evaluation (PRWHE) scores, abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) scores, and pain improved similarly and significantly in both groups. Wrist motion improved significantly in the Motec group only, and forearm rotation in the ReMotion group only. Cobalt (Co) and chromium (Cr) blood ion levels were significantly higher in the metal-on-metal (MoM) Motec group than in the metal-on-polyethylene (MoP) ReMotion group. Mean total translation was 0.65 mm (95% confidence interval (CI) 0.26 to 1.12) and 0.27 mm (95% CI 0.14 to 0.47) for the ReMotion carpal and radial components, and 0.32 mm (95% CI 0.22 to 0.45) and 0.26 mm (95% CI 0.20 to 0.34) for the Motec metacarpal and radial components, respectively. Apart from dorsal and volar
Patients with midcarpal instability are difficult to manage. It is a rare condition, and few studies have reported the outcomes of surgical treatment. No prospective or retrospective study has reported the results of arthroscopic palmar capsuloligamentous suturing. Our aim was to report the results of a prospective study of arthroscopic suture of this ligament complex in patients with midcarpal instability. This prospective single-centre study was undertaken between March 2012 and May 2022. The primary outcome was to evaluate the functional outcomes of arthroscopic palmar midcarpal suture. The study included 12 patients, eight male and four female, with a mean age of 27.5 years (19 to 42). They were reviewed at three months, six months, and one year postoperatively.Aims
Methods
Aims. We conducted a study to determine whether radiological parameters
correlate with patient reported functional outcome, health-related
quality of life and physical measures of function in patients with
a fracture of the distal radius. Patients and Methods. The post-operative palmar
Aims. The degree of displacement of a fracture of the distal radius
is an important factor which can be assessed using simple radiographic
measurements. Our aim was to investigate the reliability and reproducibility
of these measurements and to determine if they should be used clinically. Patients and Methods. A 10% sample was randomly generated from 3670 consecutive adult
patients who had presented to University Hospitals of Leicester
NHS Trust between 2007 and 2010 with a fracture of the distal radius.
Radiographs of the 367 patients were assessed by two independent
reviewers. Four measurements of displacement of the fracture were recorded
and the inter-observer correlation assessed using the intra-class
correlation coefficient. Results. Inter-observer correlation was high (>
0.8) for three of the
four measurements. Repeat measurements of a further randomly generated
10% sample (37) were made four weeks later to assess intra-observer
agreement, which was again high (>
0.8) for the same three parameters
(radial height, radial inclination and dorsal/palmar tilt). Correlation was
poor for articular step and gap. Conclusion. Radiographic assessment of radial angle, radial inclination and
dorsal/palmar
A conventional arthroscopic capsuloligamentous repair is a reliable surgical solution in most patients with scapholunate instability. However, this repair does not seem to be sufficient for more advanced injuries. The aim of this study was to evaluate the functional results of a wide arthroscopic dorsal capsuloligamentous repair (WADCLR) in the management of severe scapholunate instability. This was a prospective single-centre study undertaken between March 2019 and May 2021. The primary outcome was the evaluation of the reduction of the radiological deformity and the functional outcomes after WADCLR. A secondary outcome was the evaluation of the effectiveness of this technique in patients with the most severe instability (European Wrist Arthroscopy Society (EWAS) stage 5). The patients were reviewed postoperatively at three, six, and 12 months.Aims
Methods
There is no level I evidence dealing with the optimal period of immobilization for patients with a displaced distal radial fracture following closed reduction. A shorter period might lead to a better functional outcome due to less stiffness and pain. The aim of this study was to investigate whether this period could be safely reduced from six to four weeks. This multicentre randomized controlled trial (RCT) included adult patients with a displaced distal radial fracture, who were randomized to be treated with immobilization in a cast for four or six weeks following closed reduction. The primary outcome measure was the Patient-Rated Wrist Evaluation (PRWE) score after follow-up at one year. Secondary outcomes were the abbreviated version of the Disability of Arm, Shoulder and Hand (QuickDASH) score after one year, the functional outcome at six weeks, 12 weeks, and six months, range of motion (ROM), the level of pain after removal of the cast, and complications.Aims
Methods
We performed a retrospective study to determine
the effect of osteoporosis on the functional outcome of osteoporotic
distal radial fractures treated with a volar locking plate. Between
2009 and 2012 a total of 90 postmenopausal women with an unstable
fracture of the distal radius treated with a volar locking plate
were studied. Changes in the radiological parameters of 51 patients
with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 (. sd. 0.56))
were not significantly different from those in 39 patients without
osteoporosis (group 2, mean age 61.1, mean T-score –1.72 (. sd. 0.57)).
The mean Disabilities of the Arm, Shoulder and Hand (DASH) score
at final follow-up was 11.5 (. sd. 12.2) in group 1 and 10.5
(. sd. 13.25) in group 2. The mean modified Mayo wrist score
at final follow-up was 79.0 (. sd. 14.04) in group 1 and 82.6
(. sd. 13.1) in group 2. However, this difference was not
statistically significant (p = 0.35 for DASH score, p = 0.2 for
modified Mayo wrist score). Univariable and multivariable logistic regression
analysis showed that only the step-off of the radiocarpal joint
was related to both a poor DASH and modified Mayo wrist score. Pearson’s
correlation coefficient showed a weak negative relationship only
between the
T-score and the change in volar
The primary aim of this study was to describe patient satisfaction and health-related quality of life (HRQoL) following corrective osteotomy for a symptomatic malunion of the distal radius. We retrospectively identified 122 adult patients from a single centre over an eight-year period who had undergone corrective osteotomy for a symptomatic malunion of the distal radius. The primary long-term outcome was the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes included the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, the EQ-5D-5L score, complications, and the Net Promoter Score (NPS). Multivariate regression analysis was used to determine factors associated with the PRWE score.Aims
Methods
Patients with a triangular fibrocartilage complex (TFCC) injury report ulnar-sided wrist pain and impaired function. The surgical procedure of TFCC reinsertion aims to improve function in patients with this injury in whom conservative treatment has failed. The purpose of this study was to investigate the outcomes of open TFCC reinsertion. The study involved 274 patients who underwent open repair of the TFCC between December 2013 and December 2018. The patients completed the Patient-Rated Wrist Evaluation (PRWE) questionnaire, and scored pain and function using a visual analogue scale (VAS). Range of motion (ROM) was assessed by experienced hand therapists.Aims
Methods
The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear. Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables.Aims
Methods
Positive ulnar variance is an established risk factor for idiopathic
ulnar impaction syndrome (UIS). However, not all patients with positive
ulnar variance develop symptomatic UIS and other factors, including
the morphology of the lunate, may be involved. The aim of this study
was to clarify the relationship between lunate morphology and idiopathic
UIS. A cohort of 95 patients with idiopathic UIS (UIS group) was compared
with 95 asymptomatic controls with positive ulnar variance. The
shape of the lunate was measured using the capitate-triquetrum distance
(CTD), ulnar coverage ratio (UCR), radiolunate distance and radiolunate
angle. The association of radiographic parameters and lunate types
with the development of UIS was investigated in univariable and
multivariable analyses. Receiver operating characteristic curves
were used to estimate a cutoff for any statistically significant
variables.Aims
Patients and Methods
This article is a systematic review of the published
literature about the biomechanics, functional outcome and complications
of intramedullary nailing of fractures of the distal radius. We searched the Medline and EMBASE databases and included all
studies which reported the outcome of intramedullary (IM) nailing
of fractures of the distal radius. Data about functional outcome,
range of movement (ROM), strength and complications, were extracted.
The studies included were appraised independently by both authors
using a validated quality assessment scale for non-controlled studies
and the CONSORT statement for randomised controlled trials (RCTs). The search strategy revealed 785 studies, of which 16 were included
for full paper review. These included three biomechanical studies,
eight case series and five randomised controlled trials (RCTs). The biomechanical studies concluded that IM nails were at least
as strong as locking plates. The clinical studies reported that
IM nailing gave a comparable ROM, functional outcome and grip strength
to other fixation techniques. However, the mean complication rate of intramedullary nailing
was 17.6% (0% to 50%). This is higher than the rates reported in
contemporary studies for volar plating. It raises concerns about
the role of intramedullary nailing, particularly when comparative
studies have failed to show that it has any major advantage over
other techniques. Further adequately powered RCTs comparing the
technique to both volar plating and percutaneous wire fixation are needed. Cite this article:
There is no consensus on the benefit of arthroscopically
assisted reduction of the articular surface combined with fixation
using a volar locking plate for the treatment of intra-articular
distal radial fractures. In this study we compared the functional
and radiographic outcomes of fluoroscopically and arthroscopically
guided reduction of these fractures. Between February 2009 and May 2013, 74 patients with unilateral
unstable intra-articular distal radial fractures were randomised
equally into the two groups for treatment. The mean age of these
74 patients was 64 years (24 to 92). We compared functional outcomes
including active range of movement of the wrist, grip strength and Disabilities
of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic
outcomes that included gap, step, radial inclination, volar angulation
and ulnar variance. There were no significant differences between the techniques
with regard to functional outcomes or radiographic parameters. The
mean gap and step in the fluoroscopic and arthroscopic groups were
comparable at 0.9 mm (standard deviation Arthroscopic reduction conferred no advantage over conventional
fluoroscopic guidance in achieving anatomical reduction of intra-articular
distal radial fractures when using a volar locking plate. Cite this article:
The osteoinductive properties of demineralised
bone matrix have been demonstrated in animal studies. However, its therapeutic
efficacy has yet to be proven in humans. The clinical properties
of AlloMatrix, an injectable calcium-based demineralised bone matrix
allograft, were studied in a prospective randomised study of 50
patients with an isolated unstable distal radial fracture treated
by reduction and Kirschner (K-) wire fixation. A total of 24 patients
were randomised to the graft group (13 men and 11 women, mean age
42.3 years (20 to 62)) and 26 to the no graft group (8 men and 18
women, mean age 45.0 years (17 to 69)). At one, three, six and nine weeks, and six and 12 months post-operatively,
patients underwent radiological evaluation, assessments for range
of movement, grip and pinch strength, and also completed the Disabilities
of Arm, Shoulder and Hand questionnaire. At one and six weeks and
one year post-operatively, bone mineral density evaluations of both
wrists were performed. No significant difference in wrist function and speed of recovery,
rate of union, complications or bone mineral density was found between
the two groups. The operating time was significantly higher in the
graft group (p = 0.004). Radiologically, the reduction parameters
remained similar in the two groups and all AlloMatrix extraosseous leakages
disappeared after nine weeks. This prospective randomised controlled trial did not demonstrate
a beneficial effect of AlloMatrix demineralised bone matrix in the
treatment of this category of distal radial fractures treated by
K-wire fixation. Cite this article:
The aims of this study were to assess the efficacy
of a newly designed radiological technique (the radial groove view)
for the detection of protrusion of screws in the groove for the
extensor pollicis longus tendon (EPL) during plating of distal radial
fractures. We also aimed to determine the optimum position of the
forearm to obtain this view. We initially analysed the anatomy of
the EPL groove by performing three-dimensional CT on 51 normal forearms.
The mean horizontal angle of the groove was 17.8° (14° to 23°).
We found that the ideal position of the fluoroscopic beam to obtain
this view was 20° in the horizontal plane and 5° in the sagittal
plane. We then intra-operatively assessed the use of the radial groove
view for detecting protrusion of screws in the EPL groove in 93
fractures that were treated by volar plating. A total of 13 protruding
screws were detected. They were changed to shorter screws and these
patients underwent CT scans of the wrist immediately post-operatively.
There remained one screw that was protruding. These findings suggest
that the use of the radial groove view intra-operatively is a good
method of assessing the possible protrusion of screws into the groove
of EPL when plating a fracture of the distal radius. Cite this article: