Aims. Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head
Aims. Corticosteroid injections are often used to manage glenohumeral arthritis in patients who may be candidates for future total shoulder arthroplasty (TSA) or reverse shoulder arthroplasty (rTSA). In the conservative management of these patients, corticosteroid injections are often provided for symptomatic relief. The purpose of this study was to determine if the timing of corticosteroid injections prior to
Aims. The aim of this study was to characterize the influence of social deprivation on the rate of complications, readmissions, and revisions following primary total shoulder arthroplasty (TSA), using the Social Deprivation Index (SDI). The SDI is a composite measurement, in percentages, of seven demographic characteristics: living in poverty, with < 12 years of education, single-parent households, living in rented or overcrowded housing, households without a car, and unemployed adults aged < 65 years. Methods. Patients aged ≥ 40 years, who underwent primary
Aims. The impact of tobacco use on readmission and medical and surgical complications has been documented in hip and knee arthroplasty. However, there remains little information about the effect of smoking on the outcome after total shoulder arthroplasty (TSA). We hypothesized that active smokers are at an increased risk of poor medical and surgial outcomes after
Aims. Few studies have compared survivorship of total shoulder arthroplasty (TSA) with hemiarthroplasty (HA). This observational study compared survivorship of
Aims. Shoulder arthroplasty using short humeral components is becoming increasingly popular. Some such components have been associated with relatively high rates of adverse radiological findings. The aim of this retrospective review was to evaluate the radiological humeral bone changes and mechanical failure rates with implantation of a short cementless humeral component in anatomical (TSA) and reverse shoulder arthroplasty (RSA). Patients and Methods. A total of 100 shoulder arthroplasties (35
We assessed the age-related differences in the
use of total shoulder arthroplasty (TSA) and outcomes, and associated
time-trends using the United States Nationwide Inpatient Sample
(NIS) between 1998 and 2010. Age was categorised as <
50, 50
to 64, 65 to 79 and ≥ 80 years. Time-trends in the use of
Aims. Depression can significantly affect quality of life and is associated
with higher rates of medical comorbidities and increased mortality
following surgery. Although depression has been linked to poorer
outcomes following orthopaedic trauma, total joint arthroplasty
and spinal surgery, we wished to examine the impact of depression
in elective total shoulder arthroplasty (TSA) as this has not been
previously explored. . Patients and Methods. The United States Nationwide Inpatient Sample (NIS) was used
to identify patients undergoing elective
Aims. The aim of this study was to evaluate the differences in revision and complication rates, functional outcomes, and radiological outcomes between cemented and press-fit humeral stems in primary anatomical total shoulder arthroplasty (TSA). Materials and Methods. A comprehensive systematic review and meta-analysis was conducted searching for studies that included patients who underwent primary anatomical
Aims. The aim of the present study was to compare the 30- and 90-day
re-admission rates and complication rates of outpatient and inpatient
total shoulder arthroplasty (TSA). Patients and Methods. The United States Medicare Standard Analytical Files database
was questioned to identify patients who had undergone outpatient
or inpatient
Aims. The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up. Methods. Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening. Results. Mean OSS at mean follow-up of 6.67 years (5.0 to 10.74) was 40.12 (9 to 48), with no statistically significant difference between those implanted for a non-OA indication and those for OA (p = 0.056) or time-dependent deterioration between two years and five years (p = 0.206). Ranges of motion significantly improved compared with preoperative findings and were maintained between two and five years with a mean external rotation of 38° (SD 18.1, 0 to 100) and forward elevation of 152° (SD 29.9, 90 to 180). Of those components with radiographs suitable for analysis (n = 83), 23 (28%) were found to have a least one humeral radiolucent line, which were predominantly incomplete, less than 2 mm, and in a single anatomical zone. No humeral components were loose. A radiolucent line was present around 22 (15%) of glenoid components, and 15 (10%) of components had failed. Rotator cuff failure was found in 21 (15%) components. The mean time to either glenoid or rotator cuff failure was greater than three years following implantation. Survivorship was 96.4% (95% CI 91.6 to 98.5, number at risk 128) at five years, and 94.3% (95% CI 88.2 to 97.3, number at risk 76) at seven years, both of which compare favourably with best results taken from available registries. Conclusion. Functional and radiological outcomes of the Eclipse stemless
Aims. Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes. Methods. In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score. Results. At two years, median translation along the x-, y-, and z-axis was -0.12 mm (interquartile range (IQR) -0.18 to 0.02), -0.17 mm (IQR -0.27 to -0.09), and 0.09 mm (IQR 0.02 to 0.31). Median rotation around the x-, y-, and z-axis was 0.12° (IQR -0.50 to 0.57), -0.98° (IQR -1.83 to 1.23), and 0.09° (IQR -0.76 to 0.30). Overall, 20 prostheses stabilized within 12 months postoperatively. Four prostheses showed continuous migration between 12 and 24 months. At two-year follow-up, with the exception of one revised prosthesis, all clinical scores improved significantly (median VAS difference at rest: -3.0 (IQR -1.5 to -6.0); OSS 22.0 (IQR 15.0 to 25.0); CMS 29.5 (IQR 15.0 to 35.75); and DASH -30.0 (IQR -20.6 to -41.67) (all p < 0.001)) with the exception of one revised prosthesis. Conclusion. In conclusion, we found that 20 out of 24 implants stabilized within 12 months postoperatively. The significance of continuous migration in four implants is unclear and future research on the predictive value of early migration for future loosening in
Aims. Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method. Methods. This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary
Aims. The aims of this study were to investigate any possible relationship
between a preoperative sensitivity to pain and the degree of pain
at rest and on exertion with postoperative function in patients
who underwent stemless total shoulder arthroplasty (TSA). Patients and Methods. In this prospective study, we included 63 patients who underwent
stemless
Aims . Few studies have evaluated the relationship between patients’
pre-operative expectations and the outcome of orthopaedic procedures.
Our aim was to determine the effect of expectations on the outcome
after primary anatomical total shoulder arthroplasty (TSA). We hypothesised
that patients with greater expectations would have better outcomes. . Patients and Methods. Patients undergoing primary anatomical
Aims. To investigate the impact of the Charlson and Elixhauser comorbidity indices on patient-reported outcomes measures (PROMs) following shoulder arthroplasty. Methods. Patients undergoing total shoulder arthroplasty (TSA), reverse shoulder arthroplasty (RSA), or hemiarthroplasty (HA) from 2016 to 2018 were identified, along with the Charlson and Elixhauser comorbidities listed as their secondary diagnoses in the electronic medical records. Patients were matched to our institution’s registry to obtain their PROMs, including shoulder-specific (American Shoulder and Elbow Society (ASES) and Shoulder Activity Scale (SAS)) and general health scales (12-Item Short Form Survey (SF-12) and Patient-Reported Outcomes Measurement Information System-Pain Interference). Linear regression models adjusting for age and sex were used to evaluate the association between increasing number of comorbidities and PROM scores. A total of 1,817 shoulder arthroplasties were performed: 1,017 (56%)
Aims. Patient-specific glenoid guides (PSGs) claim an improvement in
accuracy and reproducibility of the positioning of components in
total shoulder arthroplasty (TSA). The results have not yet been
confirmed in a prospective clinical trial. Our aim was to assess
whether the use of PSGs in patients with osteoarthritis of the shoulder
would allow accurate and reliable implantation of the glenoid component. Patients and Methods. A total of 17 patients (three men and 14 women) with a mean age
of 71 years (53 to 81) awaiting
Aims. We evaluated clinical and radiographic outcomes of total shoulder
arthroplasty (TSA) using the second-generation Trabecular Metal
(TM) Glenoid component. The first generation component was withdrawn
in 2005 after a series of failures were reported. Between 2009 and
2012, 40 consecutive patients with unilateral
Aims. Promising medium-term results from total shoulder arthroplasty
(TSA) have been reported for the treatment of primary osteoarthritis
in young and middle-aged patients. The aim of this study was to
evaluate the long-term functional and radiological outcome of TSA
in the middle-aged patient. Patients and Methods. The data of all patients from the previous medium-term study
were available. At a mean follow-up of 13 years (8 to 17), we reviewed
21 patients (12 men, nine women, 21 shoulders) with a mean age of
55 years (37 to 60). The Constant-Murley score (CS) with its subgroups
and subjective satisfaction were measured. Radiological signs of implant
loosening were analysed. Results. Two shoulders (two patients) were revised and in two shoulders
of two different patients, revision surgery was recommended. The
mean CS increased from 23.3 (10 to 45) pre-operatively to 56.5 (26
to 81; p <
0.0001), but with a decrease in CS from 62.8 (38 to
93) to 56.5 (26 to 81) between medium- and long-term follow-up (p
= 0.01). Without revision surgery, 18 patients (95%) rated their
result as good or very good. The mean radiolucent line score for the glenoid components increased
from 1.8 (0 to 6) to 8.2 (2 to 18) between medium- and long-term
follow-up (p <
0.001). . Conclusion.
Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA. MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated.Aims
Methods