Advertisement for orthosearch.org.uk
Results 1 - 20 of 87
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1052 - 1059
1 Oct 2023
El-Sahoury JAN Kjærgaard K Ovesen O Hofbauer C Overgaard S Ding M

Aims. The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA). Methods. A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size. Results. A total of 116 patients participated, of whom 77 were male. The median ages of the vE-PE 32 mm and 36 mm groups were 65 (interquartile range (IQR) 57 to 67) and 63 years (IQR 56 to 66), respectively, and of the XLPE 32 mm and 36 mm groups were 64 (IQR 58 to 66) and 61 years (IQR 54 to 66), respectively. Mean total head penetration was significantly lower into vE-PE acetabular liner groups than into XLPE acetabular liner groups (-0.219 mm (95% confidence interval -0.348 to -0.090); p = 0.001). There were no differences in wear according to head size, acetabular component migration, or PROMs, except for UCLA. There were no cases of aseptic loosening or failures requiring revision at long-term follow-up. Conclusion. Significantly lower wear was observed in vE-PE acetabular liners than in XLPE acetabular liners. No difference in wear was observed between different head size or PROMs except for the UCLA at ten years. Cite this article: Bone Joint J 2023;105-B(10):1052–1059


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 542 - 546
1 Mar 2021
Milosevic S Andersen GØ Jensen MM Rasmussen MM Carreon L Andersen MØ Simony A

Aims. The aim of this study was to investigate the efficacy of coccygectomy in patients with persistent coccydynia and coccygeal instability. Methods. The Danish National Spine Registry, DaneSpine, was used to identify 134 consecutive patients who underwent surgery, performed by a single surgeon between 2011 and 2019. Routine demographic data, surgical variables, and patient-reported outcomes, including a visual analogue scale (VAS) (0 to 100) for pain, Oswestry Disability Index (ODI), EuroQol five-dimension questionnaire (EQ-5D), and the Physical Component Score (PCS) and Mental Component Score (MCS) of the 36-Item Short-Form Health Survey questionnaire (SF-36) were collected at baseline and one-year postoperatively. Results. A total of 112 (84%) patients with a minimum follow-up of one year had data available for analysis. Their mean age was 41.9 years, and 15 (13%) were males. At 12 months postoperatively, there were statistically significant improvements (p < 0.001) from baseline for the mean VAS for pain (70.99 to 35.34), EQ-5D (0.52 to 0.75), ODI (31.84 to 18.00), and SF-36 PCS (38.17 to 44.74). A total of 78 patients (70%) were satisfied with the outcome of treatment. Conclusion. Patients with persistent coccydynia and coccygeal instability resistant to nonoperative treatment may benefit from coccygectomy. Cite this article: Bone Joint J 2021;103-B(3):542–546


Aims. The aim is to assess the cost-effectiveness of patellofemoral arthroplasty (PFA) in comparison with total knee arthroplasty (TKA) for the treatment of isolated patellofemoral osteoarthritis (OA) based on prospectively collected data on health outcomes and resource use from a blinded, randomized, clinical trial. Methods. A total of 100 patients with isolated patellofemoral osteoarthritis were randomized to receive either PFA or TKA by experienced knee surgeons trained in using both implants. Patients completed patient-reported outcomes including EuroQol five-dimension questionnaire (EQ-5D) and 6-Item Short-Form Health Survey questionnaire (SF-6D) before the procedure. The scores were completed again after six weeks, three, six, and nine months, and again after one- and two-year post-surgery and yearly henceforth. Time-weighted outcome measures were constructed. Cost data were obtained from clinical registrations and patient-reported questionnaires. Incremental gain in health outcomes (quality-adjusted life-years (QALYs)) and incremental costs were compared for the two groups of patients. Net monetary benefit was calculated assuming a threshold value of €10,000, €35,000, and €50,000 per QALY and used to test the statistical uncertainty and central assumptions about outcomes and costs. Results. The PFA group had an incremental 12 month EQ-5D gain of 0.056 (95% confidence interval (CI) 0.01 to 0.10) and an incremental 12 month cost of minus €328 (95% CI 836 to 180). PFA therefore dominates TKA by providing better and cheaper outcomes than TKA. The net monetary benefit of PFA was €887 (95% CI 324 to 1450) with the €10,000 threshold, and it was consistently positive when different measures of outcomes and different cost assumptions were used. Conclusion. This study provides robust evidence that PFA from a one-year hospital management perspective is cheaper and provides better outcomes than TKA when applied to patients with isolated patellofemoral osteoarthritis and performed by experienced knee surgeons. Cite this article: Bone Joint J 2020;102-B(4):449–457


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1289 - 1296
1 Oct 2020
Amstutz HC Le Duff M

Aims. Hip resurfacing arthroplasty (HRA) is typically indicated for young and active patients. Due to the longevity of arthroplasty, these patients are likely to undergo revision surgery during their lifetime. There is a paucity of information on the long-term outcome of revision surgeries performed after failed HRA. The aim of our study was to provide survivorship data as well as clinical scores after HRA revisions. Methods. A total of 42 patients (43 hips) were revised after HRA at our centre to a variety of devices, including four HRA and 39 total hip arthroplasties (THAs). In addition to perioperative complications, University of California, Los Angeles (UCLA) hip scores and 12-Item Short-Form Health Survey questionnaire (SF-12) quality of life scores were collected at follow-up visits after the primary HRA and after revision surgery. Results. The mean follow-up time after revision surgery was 8.3 years (0.3 to 19.1). The mean UCLA pain and function scores post-revision were comparable with the best scores achieved by the patients after the index HRA, but UCLA activity scores were lower after revision. SF-12 physical component scores were comparable between timepoints, but the mental component score decreased after revision. Six patients underwent unilateral re-revision surgery at a mean follow-up time of 7.8 years (0.3 to 13.7). Using the time to any re-revision as endpoint, the Kaplan-Meier survivorship was 85.3% at 13 years. Conclusion. Patients undergoing revision after HRA can expect to achieve function and quality of life similar to their best after their primary surgery, while the risk of re-revision is low. Cite this article: Bone Joint J 2020;102-B(10):1289–1296


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 995 - 1001
1 Aug 2019
Nicholson JA Clement N Goudie E Robinson CM

Aims. The primary aim of this study was to establish the cost-effectiveness of the early fixation of displaced midshaft clavicle fractures. Patients and Methods. A cost analysis was conducted within a randomized controlled trial comparing conservative management (n = 92) versus early plate fixation (n = 86) of displaced midshaft clavicular fractures. The incremental cost-effectiveness ratio (ICER) was used to express the cost per quality-adjusted life-year (QALY). The Six-Dimension Short-Form Health Survey (SF-6D) score was used as the preference-based health index to calculate the cost per QALY at 12 months after the injury. Results. The mean 12-month SF-6D was 0.9522 (95% confidence interval (CI) 0.9355 to 0.9689) following conservative management and 0.9607 (95% CI 0.9447 to 0.9767) following fixation, giving an advantage for fixation of 0.0085, which was not statistically significant (p = 0.46). The mean cost per patient was £1322.69 for conservative management and £5405.32 for early fixation. This gave an ICER of £480 309.41 per QALY. For a threshold of £20 000 per QALY, the benefit of fixation would need to be present for 24 years to be cost-effective compared with conservative treatment. Linear regression analysis identified nonunion as the only factor to adversely influence the SF-6D at 12 months (p < 0.001). Conclusion. Routine plate fixation of displaced midshaft clavicular fractures is not cost-effective. Nonunion following conservative management has an increased morbidity with comparable expense to early fixation. This may suggest that a targeted approach of fixation in patients who are at higher risk of nonunion would be more cost-effective than the routine fixation of all displaced fractures. Cite this article: Bone Joint J 2019;101-B:995–1001


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 338 - 346
1 Feb 2021
Khow YZ Liow MHL Lee M Chen JY Lo NN Yeo SJ

Aims. This study aimed to identify the tibial component and femoral component coronal angles (TCCAs and FCCAs), which concomitantly are associated with the best outcomes and survivorship in a cohort of fixed-bearing, cemented, medial unicompartmental knee arthroplasties (UKAs). We also investigated the potential two-way interactions between the TCCA and FCCA. Methods. Prospectively collected registry data involving 264 UKAs from a single institution were analyzed. The TCCAs and FCCAs were measured on postoperative radiographs and absolute angles were analyzed. Clinical assessment at six months, two years, and ten years was undertaken using the Knee Society Knee score (KSKS) and Knee Society Function score (KSFS), the Oxford Knee Score (OKS), the 36-Item Short-Form Health Survey questionnaire (SF-36), and range of motion (ROM). Fulfilment of expectations and satisfaction was also recorded. Implant survivorship was reviewed at a mean follow-up of 14 years (12 to 16). Multivariate regression models included covariates, TCCA, FCCA, and two-way interactions between them. Partial residual graphs were generated to identify angles associated with the best outcomes. Kaplan-Meier analysis was used to compare implant survivorship between groups. Results. Significant two-way interaction effects between TCCA and FCCA were identified. Adjusted for each other and their interaction, a TCCA of between 2° and 4° and a FCCA of between 0° and 2° were found to be associated with the greatest improvements in knee scores and the probability of fulfilling expectations and satisfaction at ten years. Patients in the optimal group whose TCCA and FCCA were between 2° and 4°, and 0° and 2°, respectively, had a significant survival benefit at 15 years compared with the non-optimal group (optimal: survival = 100% vs non-optimal: survival = 92%, 95% confidence interval (CI) 88% to 96%). Conclusion. Significant two-way interactions between the TCCA and FCCA demonstrate the importance of evaluating the alignment of the components concomitantly in future studies. By doing so, we found that patients who concomitantly had both a TCCA of between 2° and 4° and a FCCA of between 0° and 2° had the best patient-reported outcome measures at ten years and better survivorship at 15 years. Cite this article: Bone Joint J 2021;103-B(2):338–346


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 845 - 851
1 Jul 2020
Goh GS Liow MHL Tay YWA Chen JY Xu S Pang H Tay DK Chia S Lo N Yeo S

Aims. While patients with psychological distress have poorer short-term outcomes after total knee arthroplasty (TKA), their longer-term function is unknown. We aimed to 1) assess the influence of preoperative mental health status on long-term functional outcomes, quality of life, and patient satisfaction; and 2) analyze the change in mental health after TKA, in a cohort of patients with no history of mental health disorder, with a minimum of ten years’ follow-up. Methods. Prospectively collected data of 122 patients undergoing primary unilateral TKA in 2006 were reviewed. Patients were assessed pre- and postoperatively at two and ten years using the Knee Society Knee Score (KSKS) and Function Score (KSFS); Oxford Knee Score (OKS); and the Mental (MCS) and Physical Component Summary (PCS) which were derived from the 36-Item Short-Form Health Survey questionnaire (SF-36). Patients were stratified into those with psychological distress (MCS < 50, n = 51) and those without (MCS ≥ 50, n = 71). Multiple regression was used to control for age, sex, BMI, Charlson Comorbidity Index (CCI), and baseline scores. The rate of expectation fulfilment and satisfaction was compared between patients with low and high MCS. Results. There was no difference in the mean KSKS, KSFS, OKS, and SF-36 PCS at two years or ten years after TKA. Equal proportions of patients in each group attained the minimal clinically important difference for each score. Psychologically distressed patients had a comparable rate of satisfaction (91.8% (47/51) vs 97.1% (69/71); p = 0.193) and fulfilment of expectations (89.8% vs 97.1%; p = 0.094). The proportion of distressed patients declined from 41.8% preoperatively to 29.8% at final follow-up (p = 0.021), and their mean SF-36 MCS improved by 10.4 points (p < 0.001). Conclusion. Patients with poor mental health undergoing TKA may experience long-term improvements in function and quality of life that are comparable to those experienced by their non-distressed counterparts. These patients also achieved a similar rate of satisfaction and expectation fulfilment. Undergoing TKA was associated with improvements in mental health in distressed patients, although this effect may be due to residual confounding. Cite this article: Bone Joint J 2020;102-B(7):845–851


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 376 - 385
1 Mar 2022
Gramlich Y Hofmann L Kress S Ruckes C Kemmerer M Klug A Hoffmann R Kremer M

Aims. This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant. Methods. A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life. Results. No differences in mean age (69 years, 40 to 86), mean age adapted Charlson Comorbidity Index (3.1 (SD 1.4)), mean BMI (29.2 kg/m. 2. (SD 5.8)), or number of other implants were observed between groups. Significant improvements in outcome scores and pain levels were achieved for all groups, and there was no difference in quality of life (12-Item Short-Form Health Survey questionnaire (SF-12)). Mean cobalt and chromium ion levels were significantly higher for the GenuX versus the BPKS hinged TKA (GenuX vs BPKS: cobalt: 16.3 vs 9.4 µg/l; chromium: 9.5 vs 5.2 µg/l). The TiN-coated implants did not appear to confer improvement in the metal ion levels. Metal ion concentrations above 7 µg/l were detected in 81%(29/36) of GenuX patients versus 41% (11/27) in the BPKS group. No GenuX patients had normal levels under 2 µg/l, versus 22% of BPKS patients. No significant reduction in outcome scores was observed regardless of the metal ion levels, whereas higher work-related activity was correlated with higher chromium concentrations. Conclusion. Hinged TKA, using MoM hinges, resulted in critically high cobalt and chromium ion concentrations. The BPKS hinged TKA showed significantly lower metal ion concentrations compared with the GenuX TKA. No benefits were observed using TiN coating. The different weightbearing mechanics might influence the wear of the component materials. Higher workloads and physical activity could influence chromium levels. Cite this article: Bone Joint J 2022;104-B(3):376–385


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1303 - 1310
3 Oct 2020
Kjærgaard K Ding M Jensen C Bragdon C Malchau H Andreasen CM Ovesen O Hofbauer C Overgaard S

Aims. The most frequent indication for revision surgery in total hip arthroplasty (THA) is aseptic loosening. Aseptic loosening is associated with polyethylene liner wear, and wear may be reduced by using vitamin E-doped liners. The primary objective of this study was to compare proximal femoral head penetration into the liner between a) two cross-linked polyethylene (XLPE) liners (vitamin E-doped (vE-PE)) versus standard XLPE liners, and b) two modular femoral head diameters (32 mm and 36 mm). Methods. Patients scheduled for a THA were randomized to receive a vE-PE or XLPE liner with a 32 mm or 36 mm metal head (four intervention groups in a 2 × 2 factorial design). Head penetration and acetabular component migration were measured using radiostereometric analysis at baseline, three, 12, 24, and 60 months postoperatively. The Harris Hip Score, University of California, Los Angeles (UCLA) Activity Score, EuroQol five-dimension questionnaire (EQ-5D), and 36-Item Short-Form Health Survey questionnaire (SF-36) were assessed at baseline, three, 12, 36, and 60 months. Results. Of 220 screened patients, 127 were included in this study. In all, 116 received the allocated intervention, and 94 had their results analyzed at five years. Head penetration was similar between liner materials and head sizes at five years, vE-PE versus XLPE was -0.084 mm (95% confidence interval (CI) -0.173 to 0.005; p = 0.064), and 32 mm versus 36 mm was -0.020 mm (95% CI -0.110 to 0.071; p = 0.671), respectively. No differences were found in acetabular component migration or in the patient-reported outcome measures. Conclusion. No significant difference in head penetration was found at five years between vE-PE and XLPE liners, nor between 32 mm and 36 mm heads. Cite this article: Bone Joint J 2020;102-B(10):1303–1310


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1526 - 1533
1 Dec 2019
Endler P Ekman P Berglund I Möller H Gerdhem P

Aims. Chronic low back pain due to degenerative disc disease is sometimes treated with fusion. We compared the outcome of three different fusion techniques in the Swedish Spine Register: noninstrumented posterolateral fusion (PLF), instrumented posterolateral fusion (IPLF), and interbody fusion (IBF). Patients and Methods. A total of 2874 patients who were operated on at one or two lumbar levels were followed for a mean of 9.2 years (3.6 to 19.1) for any additional lumbar spine surgery. Patient-reported outcome data were available preoperatively (n = 2874) and at one year (n = 2274), two years (n = 1958), and a mean of 6.9 years (n = 1518) postoperatively and consisted of global assessment and visual analogue scales of leg and back pain, Oswestry Disability Index, EuroQol five-dimensional index, 36-Item Short-Form Health Survey, and satisfaction with treatment. Statistical analyses were performed with competing-risks proportional hazards regression or analysis of covariance, adjusted for baseline variables. Results. The number of patients with additional surgery were 32/183 (17%) in the PLF group, 229/1256 (18%) in the IPLF group, and 439/1435 (31%) in the IBF group. With the PLF group as a reference, the hazard ratio for additional lumbar surgery was 1.16 (95% confidence interval (CI) 0.78 to 1.72) for the IPLF group and 2.13 (95% CI 1.45 to 3.12) for the IBF group. All patient-reported outcomes improved after surgery (p < 0.001) but were without statistically significant differences between the groups at the one-, two- and 6.9-year follow-ups (all p ≥ 0.12). Conclusion. The addition of interbody fusion to posterolateral fusion was associated with a higher risk for additional surgery and showed no advantages in patient-reported outcome. Cite this article: Bone Joint J 2019;101-B:1526–1533


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 912 - 917
1 Jul 2020
Tahir M Chaudhry EA Zimri FK Ahmed N Shaikh SA Khan S Choudry UK Aziz A Jamali AR

Aims. It has been generally accepted that open fractures require early skeletal stabilization and soft-tissue reconstruction. Traditionally, a standard gauze dressing was applied to open wounds. There has been a recent shift in this paradigm towards negative pressure wound therapy (NPWT). The aim of this study was to compare the clinical outcomes in patients with open tibial fractures receiving standard dressing versus NPWT. Methods. This multicentre randomized controlled trial was approved by the ethical review board of a public sector tertiary care institute. Wounds were graded using Gustilo-Anderson (GA) classification, and patients with GA-II to III-C were included in the study. To be eligible, the patient had to present within 72 hours of the injury. The primary outcome of the study was patient-reported Disability Rating Index (DRI) at 12 months. Secondary outcomes included quality of life assessment using 12-Item Short-Form Health Survey questionnaire (SF-12), wound infection rates at six weeks and nonunion rates at 12 months. Logistic regression analysis and independent-samples t-test were applied for secondary outcomes. Analyses of primary and secondary outcomes were performed using SPSS v. 22.0.1 and p-values of < 0.05 were considered significant. Results. A total of 486 patients were randomized between January 2016 and December 2018. Overall 206 (49.04%) patients underwent NPWT, while 214 (50.95%) patients were allocated to the standard dressing group. There was no statistically significant difference in DRI at 12 months between NPWT and standard dressing groups (mean difference 0.5; 95% confidence interval (CI) -0.08 to 1.1; p = 0.581). Regarding SF-12 scores at 12 months follow-up, there was no significant difference at any point from injury until 12 months (mean difference 1.4; 95% CI 0.7 to 1.9; p = 0.781). The 30-day deep infection rate was slightly higher in the standard gauze dressing group. The non-union odds were also comparable (odds ratio (OR) 0.90, 95% CI 0.56 to 1.45; p = 0.685). Conclusion. Our study concludes that NPWT therapy does not confer benefit over standard dressing technique for open fractures. The DRI, SF-12 scores, wound infection, and nonunion rates were analogous in both study groups. We suggest surgeons continue to use cheaper and more readily available standard dressings. Cite this article: Bone Joint J 2020;102-B(7):912–917


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 7 - 14
1 Jan 2019
Sorel JC Veltman ES Honig A Poolman RW

Aims. We performed a meta-analysis investigating the association between preoperative psychological distress and postoperative pain and function after total knee arthroplasty (TKA). Materials and Methods. Pubmed/Medline, Embase, PsycINFO, and the Cochrane library were searched for studies on the influence of preoperative psychological distress on postoperative pain and physical function after TKA. Two blinded reviewers screened for eligibility and assessed the risk of bias and the quality of evidence. We used random effects models to pool data for the meta-analysis. Results. Six prospective cohort studies, with a total of 1525 patients, were included. The random effects models showed significantly poorer outcomes in patients who preoperatively had elevated scores on the pain catastrophizing scale, worse 36-Item Short-Form Health Survey (SF-36) mental health score, symptoms of anxiety and/or depression, and somatization dysfunction. After 12 months, the standard mean difference for pain was −0.74 (95% confidence interval (CI) −1.04 to −0.44) and −0.56 (95% CI −0.80 to −0.32) for function. Conclusion. Preoperative pain catastrophizing, mental distress, symptoms of anxiety and/or depression, and somatoform disorders appear to adversely affect pain and function after TKA. Some patients undergoing TKA may therefore need psychological support to improve the outcome and quality of life


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 41 - 46
1 Jan 2019
Clement ND Howard TA Immelman RJ MacDonald D Patton JT Lawson GM Burnett R

Aims. The primary aim of this study was to compare the knee-specific functional outcome of patellofemoral arthroplasty with total knee arthroplasty (TKA) in the management of patients with patellofemoral osteoarthritis. Patients and Methods. A total of 54 consecutive Avon patellofemoral arthroplasties were identified and propensity-score-matched to a group of 54 patients undergoing a TKA with patellar resurfacing for patellofemoral osteoarthritis. The Oxford Knee Score (OKS), the 12-Item Short-Form Health Survey (SF-12), and patient satisfaction were collected at a mean follow up of 9.2 years (8 to 15). Survival was defined by revision or intention to revise. Results. There was no significant difference in the mean OKS (p > 0.60) or SF-12 scores (p > 0.28) between the groups. There was a lower rate of satisfaction at the final follow-up for the TKA group (78% vs 87%) but this was not statistically significant (odds ratio 0.56, p = 0.21). Length of stay was significantly shorter (p = 0.008) for the Avon group (difference 1.8 days, 95% confidence interval (CI) 0.4 to 3.2). The ten-year survival for the Avon group was 92.3% (95% CI 87.1 to 97.5) and for the TKA group was 100% (95% CI 93.8 to 100). This difference was not statistically significant (log-rank test, p = 0.10). Conclusion. Patients undergoing an Avon patellofemoral arthroplasty have a shorter length of stay, and a functional outcome and rate of satisfaction that is equal to that of TKA. The benefits of the Avon arthroplasty need to be balanced against the increased rate of revision when compared with TKA


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 768 - 778
1 Jul 2019
Galea VP Rojanasopondist P Ingelsrud LH Rubash HE Bragdon C Huddleston III JI Malchau H Troelsen A

Aims. The primary aim of this study was to quantify the improvement in patient-reported outcome measures (PROMs) following total hip arthroplasty (THA), as well as the extent of any deterioration through the seven-year follow-up. The secondary aim was to identify predictors of PROM improvement and deterioration. Patients and Methods. A total of 976 patients were enrolled into a prospective, international, multicentre study. Patients completed a battery of PROMs prior to THA, at three months post-THA, and at one, three, five, and seven-years post-THA. The Harris Hip Score (HHS), the 36-Item Short-Form Health Survey (SF-36) Physical Component Summary (PCS), the SF-36 Mental Component Summary (MCS), and the EuroQol five-dimension three-level (EQ-5D) index were the primary outcomes. Longitudinal changes in each PROM were investigated by piece-wise linear mixed effects models. Clinically significant deterioration was defined for each patient as a decrease of one half of a standard deviation (group baseline). Results. Improvements were noted in each PROM between the preoperative and one-year visits, with one-year values exceeding age-matched population norms. Patients with difficulty in self-care experienced less improvement in HHS (odds ratio (OR) 2.2; p = 0.003). Those with anxiety/depression experienced less improvement in PCS (OR -3.3; p = 0.002) and EQ-5D (OR -0.07; p = 0.005). Between one and seven years, obesity was associated with deterioration in HHS (1.5 points/year; p = 0.006), PCS (0.8 points/year; p < 0.001), and EQ-5D (0.02 points/year; p < 0.001). Preoperative difficulty in self-care was associated with deterioration in HHS (2.2 points/year; p < 0.001). Preoperative pain from other joints was associated with deterioration in MCS (0.8 points/year; p < 0.001). All aforementioned factors were associated with clinically significant deterioration in PROMs (p < 0.035), except anxiety/depression with regard to PCS (p = 0.060). Conclusion. The present study finds that patient factors affect the improvement and deterioration in PROMs over the medium term following THA. Special attention should be given to patients with risk factors for decreased PROMs, both preoperatively and during follow-up. Cite this article: Bone Joint J 2019;101-B:768–778


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1025 - 1032
1 Aug 2020
Hampton M Mansoor J Getty J Sutton PM

Aims. Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Methods. Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m. 2. (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up. Results. At final review all patients were between 11 and 15 years following surgery. In total, 41 of the knees were cemented and 36 uncemented. There were no revisions in the cemented group and one revision in the uncemented group for fracture. The uncemented group reported better outcomes with both statistically and clinically significant (p = 0.001) improvements in knee-specific Oxford and Knee Society scores compared with the cemented group. The global SF-12 scores demonstrated no statistical difference (p = 0.812). Uncemented knees had better radiological analysis compared with the cemented group (p < 0.001). Conclusion. Use of an uncemented trabecular metal tibial implant can afford better long-term clinical outcomes when compared to cemented tibial components of a matched design. However, both have excellent survivorship up to 15 years after implantation. Cite this article: Bone Joint J 2020;102-B(8):1025–1032


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1506 - 1510
1 Nov 2018
Parker B Petrou S Masters JPM Achana F Costa ML

Aims. The aim of this study was to estimate economic outcomes associated with deep surgical site infection (SSI) in patients with an open fracture of the lower limb. Patients and Methods. A total of 460 patients were recruited from 24 specialist trauma hospitals in the United Kingdom Major Trauma Network. Preference-based health-related quality-of-life outcomes, assessed using the EuroQol EQ-5D-3L and the 6-Item Short-Form Health Survey questionnaire (SF-6D), and economic costs (£, 2014/2015 prices) were measured using participant-completed questionnaires over the 12 months following injury. Descriptive statistics and multivariate regression analysis were used to explore the relationship between deep SSI and health utility scores, quality-adjusted life-years (QALYs), and health and personal social service (PSS) costs. Results. Deep SSI was associated with lower EQ-5D-3L derived QALYs (adjusted mean difference -0.102, 95% confidence interval (CI) -0.202 to 0.001, p = 0.047) and increased health and social care costs (adjusted mean difference £1950; 95% CI £1383 to £5285, p = 0.250) versus patients without deep SSI over the 12 months following injury. Conclusion. Deep SSI may lead to significantly impaired health-related quality of life and increased economic costs. Our economic estimates can be used to inform clinical and budgetary service planning and can act as reference data for future economic evaluations of preventive or treatment interventions. Cite this article: Bone Joint J 2018;100-B:1506–10


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 852 - 860
1 Jul 2020
Zamora T Garbuz DS Greidanus NV Masri BA

Aims. Our objective is to describe our early and mid-term results with the use of a new simple primary knee prosthesis as an articulating spacer in planned two-stage management for infected knee arthroplasty. As a second objective, we compared outcomes between the group with a retained first stage and those with a complete two-stage revision. Methods. We included 47 patients (48 knees) with positive criteria for infection, with a minimum two-year follow-up, in which a two-stage approach with an articulating spacer with new implants was used. Patients with infection control, and a stable and functional knee were allowed to retain the initial first-stage components. Outcomes recorded included: infection control rate, reoperations, final range of motion (ROM), and quality of life assessment (QoL) including Western Ontario and McMaster Universities osteoarthritis index, Knee Injury and Osteoarthritis Outcome Score, Oxford Knee Score, 12-Item Short-Form Health Survey questionnaire, and University of California Los Angeles (UCLA) activity score and satisfaction score. These outcomes were evaluated and compared to additional cohorts of patients with retained first-stage interventions and those with a complete two-stage revision. Mean follow-up was 3.7 years (2.0 to 6.5). Results. Eight knees failed directly related to lack of infection control (16%), and two patients (two knees) died within the first year for causes not directly related, giving an initial success rate of 79% (38/48). Secondary success rate after a subsequent procedure was 91% (44/48 knees). From the initially retained spacers, four knees (22%) required a second-stage revision for continuous symptoms and one (5%) for an acute infection. There were no significant differences regarding the failure rate due to infection, ROM, and QoL assessment between patients with a retained first-stage procedure and those who underwent a second-stage operation. Conclusion. Our protocol of two-stage exchange for infected knee arthroplasties with an articulating spacer and using new primary knee implants achieves adequate infection control. Retained first-stage operations achieve comparable results in selected cases, with no difference in infection control, ROM, and QoL assessment in comparison to patients with completed two-stage revision surgery. Cite this article: Bone Joint J 2020;102-B(7):852–860


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 695 - 701
1 Jun 2019
Yang H Wang S Lee K

Aims. The purpose of this study was to determine the functional outcome and implant survivorship of mobile-bearing total ankle arthroplasty (TAA) performed by a single surgeon. Patients and Methods. We reviewed 205 consecutive patients (210 ankles) who had undergone mobile-bearing TAA (205 patients) for osteoarthritis of the ankle between January 2005 and December 2015. Their mean follow-up was 6.4 years (2.0 to 13.4). Functional outcome was assessed using the Ankle Osteoarthritis Scale, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, 36-Item Short-Form Health Survey (SF-36) score, visual analogue scale, and range of movement. Implant survivorship and complications were also evaluated. Results. There were significant improvements in all functional outcome categories between the preoperative and final follow-up assessments (p < 0.001). Patients showed marked improvement in clinical outcomes in terms of pain, function, and quality of life. The overall implant survivorship was 91.7% at a mean follow-up of 6.4 years. In all, 33 major complications were identified with a 15.7% rate, resulting in 12 prosthesis failures (5.7%). Periprosthetic osteolysis (19 cases; 9.0%) was the most frequent complication. Conclusion. Mobile-bearing TAA resulted in improved functional outcomes, a low major complication rate, and excellent implant survivorship at a mean follow-up of 6.4 years. Cite this article: Bone Joint J 2019;101-B:695–701


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1534 - 1541
1 Dec 2019
Lagerbäck T Möller H Gerdhem P

Aims. The purpose of this study was to investigate the risk of additional surgery in the lumbar spine and to describe long-term changes in patient-reported outcomes after surgery for lumbar disc herniation in adolescents and young adults. Patients and Methods. We conducted a retrospective study design on prospectively collected data from a national quality register. The 4537 patients were divided into two groups: adolescents (≤ 18 years old, n = 151) and young adults (19 to 39 years old, n = 4386). The risk of additional lumbar spine surgery was surveyed for a mean of 11.4 years (6.0 to 19.3) in all 4537 patients. Long-term patient-reported outcomes were available at a mean of 7.2 years (5.0 to 10.0) in up to 2716 patients and included satisfaction, global assessment for leg and back pain, Oswestry Disability Index, visual analogue scale for leg and back pain, EuroQol five-dimension questionnaire (EQ-5D), and 36-Item Short-Form Health Survey (SF-36) Mental Component Summary and Physical Component Summary scores. Statistical analyses were performed with Cox proportional hazard regression, chi-squared test, McNemar’s test, Welch–Satterthwaite t-test, and Wilcoxon’s signed-rank test. Results. Any type of additional lumbar spine surgery was seen in 796 patients (18%). Surgery for lumbar disc herniation accounted for more than half of the additional surgeries. The risk of any additional surgery was 0.9 (95% confidence interval (CI) 0.6 to 1.4) and the risk of additional lumbar disc herniation surgery was 1.0 (0.6 to 1.7) in adolescents compared with the young adult group. Both age groups improved their patient-reported outcome data after surgery (all p < 0.001). Changes between short- (mean 1.9 years (1.0 to 2.0)) and long-term follow-up (mean 7.2 years (5.0 to 10.0)) were small. Conclusion. The risk of any additional lumbar spine surgery and additional lumbar disc herniation surgery was similar in adolescents and young adults. All patient-reported outcomes improved from preoperative to the short-term follow-up, while no likely clinically important differences between the short- and long-term follow-up were seen within both groups. Cite this article: Bone Joint J 2019;101-B:1534–1541


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1035 - 1041
1 Sep 2019
Markel DC Bou-Akl T Rossi MD Pizzimenti N Wu B Ren W

Aims. The aim of this study was to evaluate blood metal ion levels, leucocyte profiles, and serum cytokines in patients with a total hip arthroplasty (THA) involving modular dual-mobility components. Patients and Methods. A total of 39 patients were recruited, with clinical follow-up of up to two years. Outcome was assessed using the Harris Hip Score (HHS, the 12-Item Short-Form Health Survey (SF-12), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and a visual analogue scale (VAS) for pain. Blood concentrations of cobalt (Co), chromium (Cr), and serum cytokines were measured. Subpopulations of leucocytes were analyzed by flow cytometry. Results. The clinical performance was good. Blood Co levels (ref 1.0 µg/l) were mildly elevated in seven patients at three months, and two patients at two years’ follow-up. The preoperative Cr levels were normal except for one patient with a detectable Cr (1.2 µg/l). Cr levels were detectable in three patients at three months, two patients at one year, and three patients at two years’ follow-up. No patients had symptoms suggestive of failure. Although flow cytometry showed constant circulating leucocyte profiles, there was a significant reduction of serum interleukin (IL)-4, IL-5, and interferon gamma (IFNγ) postoperatively compared with the preoperative levels (p < 0.05). Conclusion. These results suggest that THA using modular dual-mobility components is safe. This allows an opportunity to use a large femoral head and a thick polyethylene bearing surface, which is especially useful in revision procedures or high-risk situations when added stability is required. Cite this article: Bone Joint J 2019;101-B:1035–1041