Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1182 - 1186
1 Sep 2018
Werner BS Chaoui J Walch G

Aims. Scapular notching is a frequently observed radiographic phenomenon in reverse shoulder arthroplasty (RSA), signifying impingement of components. The purposes of this study were to evaluate the effect of glenoid component size and glenosphere type on impingement-free range of movement (ROM) for extension and internal and external rotation in a virtual RSA model, and to determine the optimal configuration to reduce the incidence of friction-type scapular notching. Materials and Methods. Preoperative CT scans obtained in 21 patients (three male, 18 female) with primary osteoarthritis were analyzed using modelling software. Two concurrent factors were tested for impingement-free ROM and translation of the centre of rotation: glenosphere diameter (36 mm vs 39 mm) and type (centred, 2 mm inferior eccentric offset, 10° inferior tilt). Results. Glenosphere size was most predictive of increased extension and external rotation, whereas lateralization of the centre of rotation was the most predictive factor for internal rotation. A larger diameter of glenosphere combined with a 10° tilted configuration demonstrated superior values for extension and external rotation, whereas the eccentric component improved internal rotation by a mean 8.9° (standard deviation 2.7°) compared with a standard concentric glenosphere. Conclusion. Glenosphere configuration can be modified to increase range of movement in RSA. Friction-type scapular notching was most effectively reduced by use of a large-diameter glenosphere with 10° inferior tilt. Cite this article: Bone Joint J 2018;100-B:1182–6


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims

This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA).

Methods

From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 389 - 399
15 Mar 2023
Makaram NS Nicholson JA Yapp LZ Gillespie M Shah CP Robinson CM

Aims

The open Latarjet procedure is a widely used treatment for recurrent anterior instability of the shoulder. Although satisfactory outcomes are reported, factors which influence a patient’s experience are poorly quantified. The aim of this study was to evaluate the effect of a range of demographic factors and measures of the severity of instability on patient-reported outcome measures in patients who underwent an open Latarjet procedure at a minimum follow-up of two years.

Methods

A total of 350 patients with anterior instability of the shoulder who underwent an open Latarjet procedure between 2005 and 2018 were reviewed prospectively, with the collection of demographic and psychosocial data, preoperative CT, and complications during follow-up of two years. The primary outcome measure was the Western Ontario Shoulder Instability Index (WOSI), assessed preoperatively, at two years postoperatively, and at mid-term follow-up at a mean of 50.6 months (SD 24.8) postoperatively. The secondary outcome measure was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score. The influence of the demographic details of the patients, measurements of the severity of instability, and the complications of surgery were assessed in a multivariate analysis.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 718 - 724
1 Apr 2021
Cavalier M Johnston TR Tran L Gauci M Boileau P

Aims

The aim of this study was to identify risk factors for recurrent instability of the shoulder and assess the ability to return to sport in patients with engaging Hill-Sachs lesions treated with arthroscopic Bankart repair and Hill-Sachs remplissage (ABR-HSR).

Methods

This retrospective study included 133 consecutive patients with a mean age of 30 years (14 to 69) who underwent ABR-HSR; 103 (77%) practiced sports before the instability of the shoulder. All had large/deep, engaging Hill-Sachs lesions (Calandra III). Patients were divided into two groups: A (n = 102) with minimal or no (< 10%) glenoid bone loss, and B (n = 31) with subcritical (10% to 20%) glenoid loss. A total of 19 patients (14%) had undergone a previous stabilization, which failed. The primary endpoint was recurrent instability, with a secondary outcome of the ability to return to sport.


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 232 - 238
1 Feb 2020
Javed S Hadi S Imam MA Gerogiannis D Foden P Monga P

Aims

Accurate measurement of the glenoid version is important in performing total shoulder arthroplasty (TSA). Our aim was to evaluate the Ellipse method, which involves formally defining the vertical mid-point of the glenoid prior to measuring the glenoid version and comparing it with the ‘classic’ Friedman method.

Methods

This was a retrospective study which evaluated 100 CT scans for patients who underwent a primary TSA. The glenoid version was measured using the Friedman and Ellipse methods by two senior observers. Statistical analyses were performed using the paired t-test for significance and the Bland-Altman plot for agreement.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 610 - 616
1 May 2018
Giannicola G Bullitta G Rotini R Murena L Blonna D Iapicca M Restuccia G Merolla G Fontana M Greco A Scacchi M Cinotti G

Aims

The aim of the study was to analyze the results of primary tendon reinsertion in acute and chronic distal triceps tendon ruptures (DTTRs) in the general population.

Patients and Methods

A total of 28 patients were operated on for primary DTTR reinsertions, including 21 male patients and seven female patients with a mean age of 45 years (14 to 76). Of these patients, 23 sustained an acute DTTR and five had a chronic injury. One patient had a non-simultaneous bilateral DTTR. Seven patients had DTTR-associated ipsilateral fracture or dislocation. Comorbidities were present in four patients. Surgical treatment included transosseous and suture-anchors reinsertion in 22 and seven DTTRs, respectively. The clinical evaluation was performed using Mayo Elbow Performance Score (MEPS), the modified American Shoulder and Elbow Surgeons Score (m-ASES), the Quick Disabilities of the Arm, Shoulder and Hand score (QuickDASH), and the Medical Research Council (MRC) Scale.


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 318 - 323
1 Mar 2018
Raiss P Alami G Bruckner T Magosch P Habermeyer P Boileau P Walch G

Aims

The aim of this study was to analyze the results of reverse shoulder arthroplasty (RSA) in patients with type 1 sequelae of a fracture of the proximal humerus in association with rotator cuff deficiency or severe stiffness of the shoulder.

Patients and Methods

A total of 38 patients were included: 28 women and ten men. Their mean age at the time of arthroplasty was 73 years (54 to 91). Before the RSA, 18 patients had been treated with open reduction and internal fixation following a fracture. A total of 22 patients had a rotator cuff tear and 11 had severe stiffness of the shoulder with < 0° of external rotation. The mean follow-up was 4.3 years (1.5 to 10). The Constant score and the range of movement of the shoulder were recorded preoperatively and at final follow-up.

Preoperatively, radiographs in two planes were performed, as well as CT or arthro-CT scans; radiographs were also performed at final follow-up.


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 485 - 492
1 Apr 2018
Gauci MO Bonnevialle N Moineau G Baba M Walch G Boileau P

Aims

Controversy about the use of an anatomical total shoulder arthroplasty (aTSA) in young arthritic patients relates to which is the ideal form of fixation for the glenoid component: cemented or cementless. This study aimed to evaluate implant survival of aTSA when used in patients aged < 60 years with primary glenohumeral osteoarthritis (OA), and to compare the survival of cemented all-polyethylene and cementless metal-backed glenoid components.

Materials and Methods

A total of 69 consecutive aTSAs were performed in 67 patients aged < 60 years with primary glenohumeral OA. Their mean age at the time of surgery was 54 years (35 to 60). Of these aTSAs, 46 were undertaken using a cemented polyethylene component and 23 were undertaken using a cementless metal-backed component. The age, gender, preoperative function, mobility, premorbid glenoid erosion, and length of follow-up were comparable in the two groups. The patients were reviewed clinically and radiographically at a mean of 10.3 years (5 to 12, sd 26) postoperatively. Kaplan–Meier survivorship analysis was performed with revision as the endpoint.