Aim. There is not adequate evidence to establish whether external
fixation (EF) of pelvic fractures leads to a reduced mortality.
We used the Japan Trauma Data Bank database to identify isolated
unstable
We have evaluated retrospectively the relationship of bony injuries seen on 106 consecutive MR scans in elderly patients of a mean age of 81.4 years (67 to 101) who were unable to bear weight after a low-energy injury. There were no visible fractures on plain radiographs of the hip but eight patients (7.5%) had fractures of the pubic ramus. In 43 patients (40.5%) MRI revealed a fracture of the femoral neck and in 26 (24.5%) there was a fracture of a pubic ramus. In 17 patients (16%) MRI showed an occult sacral fracture and all of these had a fracture of the pubic ramus. No patient with a fracture of the femoral neck had an associated fracture of the
We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the
We performed a systematic review of the literature
to evaluate the use and interpretation of generic and disease-specific
functional outcome instruments in the reporting of outcome after
the surgical treatment of disruptions of the
We reviewed 110 patients with an unstable fracture of the
Aims. The aim of this study was to describe the use of 3D-printed sacral endoprostheses to reconstruct the
A young woman sustained disruption of the anterior
We report the functional and socioeconomic long-term
outcome of patients with
Various techniques have been used for the fixation of the posterior pelvis, each with disadvantages specific to the technique. In this study, a new protocol involving the placement of posterior pelvic screws in the CT suite is described and evaluated. A total of 66 patients with unstable
With the development of systems of trauma care the management of pelvic disruption has evolved and has become increasingly refined. The goal is to achieve an anatomical reduction and stable fixation of the fracture. This requires adequate visualisation for reduction of the fracture and the placement of fixation. Despite the advances in surgical approach and technique, the functional outcomes do not always produce the desired result. New methods of percutaneous treatment in conjunction with innovative computer-based imaging have evolved in an attempt to overcome the existing difficulties. This paper presents an overview of the technical aspects of percutaneous surgery of the pelvis and acetabulum.
The anterior pelvic internal fixator is increasingly used for
the treatment of unstable, or displaced, injuries of the anterior
pelvic ring. The evidence for its use, however, is limited. The
aim of this paper is to describe the indications for its use, how
it is applied and its complications. We reviewed the case notes and radiographs of 50 patients treated
with an anterior pelvic internal fixator between April 2010 and
December 2015 at a major trauma centre in the United Kingdom. The
median follow-up time was 38 months (interquartile range 24 to 51).Aims
Patients and Methods
The aim of this study was to assess the accuracy
of placement of pelvic binders and to determine whether circumferential
compression at the level of the greater trochanters is the best
method of reducing a symphyseal diastasis. Patients were identified by a retrospective review of all pelvic
radiographs performed at a military hospital over a period of 30
months. We analysed any pelvic radiograph on which the buckle of
the pelvic binder was clearly visible. The patients were divided
into groups according to the position of the buckle in relation
to the greater trochanters: high, trochanteric or low. Reduction
of the symphyseal diastasis was measured in a subgroup of patients
with an open-book fracture, which consisted of an injury to the
symphysis and disruption of the posterior pelvic arch (AO/OTA 61-B/C). We identified 172 radiographs with a visible pelvic binder. Five
cases were excluded due to inadequate radiographs. In 83 (50%) the
binder was positioned at the level of the greater trochanters. A
high position was the most common site of inaccurate placement,
occurring in 65 (39%). Seventeen patients were identified as a subgroup
to assess the effect of the position of the binder on reduction
of the diastasis. The mean gap was 2.8 times greater (mean difference
22 mm) in the high group compared with the trochanteric group (p
<
0.01). Application of a pelvic binder above the level of the greater
trochanters is common and is an inadequate method of reducing pelvic
fractures and is likely to delay cardiovascular recovery in these
seriously injured patients.
Aims. This study aimed to analyze the correlation between transverse
process (TP) fractures of the fourth (L4) and fifth (L5) lumbar
vertebrae and biomechanical and haemodynamic stability in patients
with a
We describe the routine imaging practices of
Level 1 trauma centres for patients with severe
Aims. Iliac wing (Type I) and iliosacral (Type I/IV) pelvic resections for a primary bone tumour create a large segmental defect in the
To date, all surgical techniques used for reconstruction
of the
Aims. The aim of the study was to investigate the controversial issue
of whether the