Advertisement for orthosearch.org.uk
Results 1 - 16 of 16
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1669 - 1673
1 Dec 2014
Van der Merwe JM Haddad FS Duncan CP

The Unified Classification System (UCS) was introduced because of a growing need to have a standardised universal classification system of periprosthetic fractures. It combines and simplifies many existing classification systems, and can be applied to any fracture around any partial or total joint replacement occurring during or after operation. Our goal was to assess the inter- and intra-observer reliability of the UCS in association with knee replacement when classifying fractures affecting one or more of the femur, tibia or patella. We used an international panel of ten orthopaedic surgeons with subspecialty fellowship training and expertise in adult hip and knee reconstruction (‘experts’) and ten residents of orthopaedic surgery in the last two years of training (‘pre-experts’). They each received 15 radiographs for evaluation. After six weeks they evaluated the same radiographs again but in a different order. . The reliability was assessed using the Kappa and weighted Kappa values. The Kappa values for inter-observer reliability for the experts and the pre-experts were 0.741 (95% confidence interval (CI) 0.707 to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted Kappa values for intra-observer reliability for the experts and pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI 0.815 to 0.942) respectively. The UCS has substantial inter-observer reliability and ‘near perfect’ intra-observer reliability when used for periprosthetic fractures in association with knee replacement in the hands of experienced and inexperienced users. Cite this article: Bone Joint J 2014;96-B:1669–73


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 464 - 471
1 Apr 2022
Veerman K Raessens J Telgt D Smulders K Goosen JHM

Aims

Debridement, antibiotics, and implant retention (DAIR) is a widely accepted form of surgical treatment for patients with an early periprosthetic joint infection (PJI) after primary arthroplasty. The outcome of DAIR after revision arthroplasty, however, has not been reported. The aim of this study was to report the success rate of DAIR after revision arthroplasty with a follow-up of two years.

Methods

This retrospective study, conducted at the Sint Maartenskliniek, Nijmegen, the Netherlands, included 88 patients who underwent DAIR within 90 days of revision total hip or total knee arthroplasty between 2012 and 2019. Details of the surgical procedures and PJI were collected. Univariate analysis and a subgroup analysis of the culture-positive group were performed. Kaplan-Meier survivorship curves were constructed.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 850 - 858
1 Sep 1998
Schai PA Thornhill TS Scott RD

A consecutive series of 235 total knee arthroplasties using the PFC system was followed prospectively for at least ten years in 186 patients. The operation was for osteoarthritis in 150 knees, for rheumatoid arthritis in 83, and for Paget’s disease and femoral osteonecrosis in one knee each. At the latest review 56 patients had died, fi ve were too ill to assess and three could not be traced. The PFC knee replacement utilised was a nonconforming posterior-cruciate-retaining prosthesis with a polyethylene insert which is fl at in the sagittal plane. The patella was resurfaced using a metal-backed component in 170 cases, but later in the series we used an all-polyethylene component in 22 knees; 43 patellae were not resurfaced. The survival without need for reoperation for any reason was 90% at ten years. Nineteen revisions were component-related due to failure of nine metal-backed patellae, nine polyethylene inserts, and one unresurfaced patella; two reoperations were for synovectomy (one for recurrent haemarthrosis and one for recurrent rheumatoid synovitis) and three were for metastatic joint infection. There were no revisions for aseptic loosening of femoral or tibial components, or the all-polyethylene patellar replacement. The PFC system provides good and predictable results in tricompartmental arthritis of the knee. Loosening appeared to be negligible, but there were wear-related problems in 8%. The change from a metal-backed patella and an increase in the contact area of the tibial insert should provide further improvement by minimising wear


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 32 - 38
1 Jan 2021
Li R Li X Ni M Fu J Xu C Chai W Chen J

Aims

The aim of this study was to further evaluate the accuracy of ten promising synovial biomarkers (bactericidal/permeability-increasing protein (BPI), lactoferrin (LTF), neutrophil gelatinase-associated lipocalin (NGAL), neutrophil elastase 2 (ELA-2), α-defensin, cathelicidin LL-37 (LL-37), human β-defensin (HBD-2), human β-defensin 3 (HBD-3), D-dimer, and procalcitonin (PCT)) for the diagnosis of periprosthetic joint infection (PJI), and to investigate whether inflammatory joint disease (IJD) activity affects their concentration in synovial fluid.

Methods

We included 50 synovial fluid samples from patients with (n = 25) and without (n = 25) confirmed PJI from an institutional tissue bank collected between May 2015 and December 2016. We also included 22 synovial fluid samples aspirated from patients with active IJD presenting to Department of Rheumatology, the first Medical Centre, Chinese PLA General Hospital. Concentrations of the ten candidate biomarkers were measured in the synovial fluid samples using standard enzyme-linked immunosorbent assays (ELISA). The diagnostic accuracy was evaluated by receiver operating characteristic (ROC) curves.


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 960 - 969
1 Aug 2019
Odgaard A Laursen MB Gromov K Troelsen A Kristensen PW Schrøder H Madsen F Overgaard S

Aims

The aim of this study was to give estimates of the incidence of component incompatibility in hip and knee arthroplasty and to test the effect of an online, real-time compatibility check.

Materials and Methods

Intraoperative barcode registration of arthroplasty implants was introduced in Denmark in 2013. We developed a compatibility database and, from May 2017, real-time compatibility checking was implemented and became part of the registration. We defined four classes of component incompatibility: A-I, A-II, B-I, and B-II, depending on an assessment of the level of risk to the patient (A/B), and on whether incompatibility was knowingly accepted (I/II).


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 235 - 239
1 Mar 1997
Takahashi T Wada Y Yamamoto H

We measured the pressure distribution across the tibiofemoral and patellofemoral joints during total knee arthroplasty (TKA) using Fuji pressure-sensitive film (Prescale) in 51 patients (63 joints) comparing the results with those in 21 patients in whom Prescale was not used. We classified the stress-distribution patterns in the tibiofemoral joints into four types: normal, varus-valgus instability, rotational malalignment, and a combination of instability and malrotation. The medial ligaments were then released according to the information obtained from these patterns. The conformity ratio of the contact area between repeated trials was 87.0%. Pressure distribution across the patellofemoral joints was also considered. There was a significant decrease in the mean valgus stress angle in the Prescale group compared with the control group (p < 0.01). Release of the lateral retinaculum according to the results showed no significant differences in subluxation of the patella between the released group and the group which did not appear to need this procedure


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 349 - 358
1 Mar 2016
Akiyama K Nakata K Kitada M Yamamura M Ohori T Owaki H Fuji T

Aims

We investigated changes in the axial alignment of the ipsilateral hip and knee after total hip arthroplasty (THA).

Patients and Methods

We reviewed 152 patients undergoing primary THA (163 hips; 22 hips in men, 141 hips in women) without a pre-operative flexion contracture. The mean age was 64 years (30 to 88). The diagnosis was osteoarthritis (OA) in 151 hips (primary in 18 hips, and secondary to dysplasia in 133) and non-OA in 12 hips. A posterolateral approach with repair of the external rotators was used in 134 hips and an anterior approach in 29 hips. We measured changes in leg length and offset on radiographs, and femoral anteversion, internal rotation of the hip and lateral patellar tilt on CT scans, pre- and post-operatively.


The Bone & Joint Journal
Vol. 99-B, Issue 1_Supple_A | Pages 60 - 64
1 Jan 2017
Lange J Haas SB

Valgus knee deformity can present a number of unique surgical challenges for the total knee arthroplasty (TKA) surgeon. Understanding the typical patterns of bone and soft-tissue pathology in the valgus arthritic knee is critical for appropriate surgical planning. This review aims to provide the knee arthroplasty surgeon with an understanding of surgical management strategies for the treatment of valgus knee arthritis.

Lateral femoral and tibial deficiencies, contracted lateral soft tissues, attenuated medial soft tissues, and multiplanar deformities may all be present in the valgus arthritic knee. A number of classifications have been reported in order to guide surgical management, and a variety of surgical strategies have been described with satisfactory clinical results. Depending on the severity of the deformity, a variety of TKA implant designs may be appropriate for use.

Regardless of an operating surgeon’s preferred surgical strategy, adherence to a step-wise approach to deformity correction is advised.

Cite this article: Bone Joint J 2017;99-B(1 Supple A):60–4.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1176 - 1182
1 Sep 2017
Berger P Van Cauter M Driesen R Neyt J Cornu O Bellemans J

Aims

The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS).

Patients and Methods

A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 89 - 94
1 Jan 2016
Cherian JJ Jauregui JJ Leichliter AK Elmallah RK Bhave A Mont MA

The purpose of this study was to evaluate the effect of various non-operative modalities of treatment (transcutaneous electrical nerve stimulation (TENS); neuromuscular electrical stimulation (NMES); insoles and bracing) on the pain of osteoarthritis (OA) of the knee.

We conducted a systematic review according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines to identify the therapeutic options which are commonly adopted for the management of osteoarthritis (OA) of the knee.

The outcome measurement tools used in the different studies were the visual analogue scale and The Western Ontario and McMaster Universities Arthritis Index pain index: all pain scores were converted to a 100-point scale.

A total of 30 studies met our inclusion criteria: 13 on insoles, seven on TENS, six on NMES, and four on bracing. The standardised mean difference (SMD) in pain after treatment with TENS was 1.796, which represented a significant reduction in pain. The significant overall effect estimate for NMES on pain was similar to that of TENS, with a SMD of 1.924. The overall effect estimate of insoles on pain was a SMD of 0.992. The overall effect of bracing showed a significant reduction in pain of 1.34.

Overall, all four non-operative modalities of treatment were found to have a significant effect on the reduction of pain in OA of the knee.

This study shows that non-operative physical modalities of treatment are of benefit when treating OA of the knee. However, much of the literature reviewed evaluates studies with follow-up of less than six months: future work should aim to evaluate patients with longer follow-up.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):89–94.


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 201 - 208
1 Feb 2016
Kingsbury SR Dube B Thomas CM Conaghan PG Stone MH

Aims

Increasing demand for total hip and knee arthroplasty (THA/TKA) and associated follow-up has placed huge demands on orthopaedic services. Feasible follow-up mechanisms are therefore essential.

Methods

We conducted an audit of clinical follow-up decision-making for THA/TKA based on questionnaire/radiograph review compared with local practice of Arthroplasty Care Practitioner (ACP)-led outpatient follow-up. In all 599 patients attending an ACP-led THA/TKA follow-up clinic had a pelvic/knee radiograph, completed a pain/function questionnaire and were reviewed by an ACP. An experienced orthopaedic surgeon reviewed the same radiographs and questionnaires, without patient contact or knowledge of the ACP’s decision. Each pathway classified patients into: urgent review, annual monitoring, routine follow-up or discharge.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 862 - 866
1 Jun 2010
Hay GC Kampshoff J Kuster MS

The lateral subvastus approach combined with an osteotomy of the tibial tubercle is a recognised, but rarely used approach for total knee replacement (TKR). A total of 32 patients undergoing primary TKR was randomised into two groups, in one of which the lateral subvastus approach combined with a tibial tubercle osteotomy and in the other the medial parapatellar approach were used. The patients were assessed radiologically and clinically using measurement of the range of movement, a visual analogue patient satisfaction score, the Western Ontario McMasters University Osteoarthritis Index and the American Knee Society score. Four patients were lost to the complete follow-up at two years.

At two years there were no significant differences between the groups in any of the parameters for clinical outcome. In the lateral approach group there was one complication due to displacement of the tibial tubercle osteotomy and two osteotomies took more than six months to unite. In the medial approach group, one patient had a partial tear of the quadriceps. There was a significantly greater incidence of lateral patellar subluxation in the medial approach group (3 of 12) compared with the lateral approach group (0 of 16) (p = 0.034), but without any apparent clinical detriment.

We conclude that the lateral approach with tibial tubercle osteotomy is a safe technique with an outcome comparable with that of the medial parapatellar approach for TKR, but the increased surgical time and its specific complications do not support its routine use. It would seem to be more appropriate to reserve this technique for patients in whom problems with patellar tracking are anticipated.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 263 - 269
1 Feb 2014
Batta V Coathup MJ Parratt MT Pollock RC Aston WJ Cannon SR Skinner JA Briggs TW Blunn GW

We reviewed the outcome of 69 uncemented, custom-made, distal femoral endoprosthetic replacements performed in 69 patients between 1994 and 2006. There were 31 women and 38 men with a mean age at implantation of 16.5 years (5 to 37). All procedures were performed for primary malignant bone tumours of the distal femur. At a mean follow-up of 124.2 months (4 to 212), 53 patients were alive, with one patient lost to follow-up. All nine implants (13.0%) were revised due to aseptic loosening at a mean of 52 months (8 to 91); three implants (4.3%) were revised due to fracture of the shaft of the prosthesis and three patients (4.3%) had a peri-prosthetic fracture. Bone remodelling associated with periosteal cortical thinning adjacent to the uncemented intramedullary stem was seen in 24 patients but this did not predispose to failure. All aseptically loose implants in this series were diagnosed to be loose within the first five years.

The results from this study suggest that custom-made uncemented distal femur replacements have a higher rate of aseptic loosening compared to published results for this design when used with cemented fixation. Loosening of uncemented replacements occurs early indicating that initial fixation of the implant is crucial.

Cite this article: Bone Joint J 2014;96-B:263–9.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 122 - 126
1 Jan 2013
McWilliams AB Douglas SL Redmond AC Grainger AJ O’Connor PJ Stewart TD Stone MH

The results of hip and knee replacement surgery are generally regarded as positive for patients. Nonetheless, they are both major operations and have recognised complications. We present a review of relevant claims made to the National Health Service Litigation Authority. Between 1995 and 2010 there were 1004 claims to a value of £41.5 million following hip replacement surgery and 523 claims to a value of £21 million for knee replacement. The most common complaint after hip surgery was related to residual neurological deficit, whereas after knee replacement it was related to infection. Vascular complications resulted in the highest costs per case in each group.

Although there has been a large increase in the number of operations performed, there has not been a corresponding relative increase in litigation. The reasons for litigation have remained largely unchanged over time after hip replacement. In the case of knee replacement, although there has been a reduction in claims for infection, there has been an increase in claims for technical errors. There has also been a rise in claims for non-specified dissatisfaction. This information is of value to surgeons and can be used to minimise the potential mismatch between patient expectation, informed consent and outcome.

Cite this article: Bone Joint J 2013;95-B:122–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 413 - 418
1 Mar 2010
Rothwell AG Hooper GJ Hobbs A Frampton CM

We analysed data from the Oxford hip and knee questionnaires collected by the New Zealand Joint Registry at six months and five years after joint replacement, to determine if there was any relationship between the scores and the risk of early revision. Logistic regression of the six-month scores indicated that for every one-unit decrease in the Oxford score, the risk of revision within two years increased by 9.7% for total hip replacement (THR), 9.9% for total knee replacement (TKR) and 12.0% for unicompartmental knee replacement (UKR). Our findings showed that 70% of the revisions within two years for TKR and 67% for THR and UKR would have been captured by monitoring the lowest 22%, 28% and 28%, respectively, of the Oxford scores. When analysed using the Kalairajah classification a score of < 27 (poor) was associated with a risk of revision within two years of 7.6% for THR, 7.0% for TKR and 24.3% for UKR, compared with risks of 0.7%, 0.7% and 1.8%, respectively, for scores > 34 (good or excellent).

Our study confirms that the Oxford hip and knee scores at six months are useful predictors of early revision after THR and TKR and we recommend their use for the monitoring of the outcome and potential failure in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 229 - 233
1 Feb 2009
Kempshall PJ Metcalfe A Forster MC

As part of the government’s initiative to reduce waiting times for major joint surgery in Wales, the Cardiff and Vale NHS Trust sent 224 patients (258 knees) to the NHS Treatment Centre in Weston-Super-Mare for total knee replacement. The Kinemax total knee replacement system was used in all cases. The cumulative survival rate at three years was 79.2% (95% confidence interval (CI) 69.2 to 86.8) using re-operation for any cause as an endpoint and 85.3% (95% CI 75.9 to 91.8) using aseptic revision as an endpoint. This is significantly worse than that recorded in the published literature. These poor results have resulted in a significant impact on our service.