Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1352 - 1361
1 Dec 2022
Trovarelli G Pala E Angelini A Ruggieri P

Aims

We performed a systematic literature review to define features of patients, treatment, and biological behaviour of multicentric giant cell tumour (GCT) of bone.

Methods

The search terms used in combination were “multicentric”, “giant cell tumour”, and “bone”. Exclusion criteria were: reports lacking data, with only an abstract; papers not reporting data on multicentric GCT; and papers on multicentric GCT associated with other diseases. Additionally, we report three patients treated under our care.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 838 - 845
1 Jun 2013
Oliveira VC van der Heijden L van der Geest ICM Campanacci DA Gibbons CLMH van de Sande MAJ Dijkstra PDS

Giant cell tumours (GCTs) of the small bones of the hands and feet are rare. Small case series have been published but there is no consensus about ideal treatment. We performed a systematic review, initially screening 775 titles, and included 12 papers comprising 91 patients with GCT of the small bones of the hands and feet. The rate of recurrence across these publications was found to be 72% (18 of 25) in those treated with isolated curettage, 13% (2 of 15) in those treated with curettage plus adjuvants, 15% (6 of 41) in those treated by resection and 10% (1 of 10) in those treated by amputation. We then retrospectively analysed 30 patients treated for GCT of the small bones of the hands and feet between 1987 and 2010 in five specialised centres. The primary treatment was curettage in six, curettage with adjuvants (phenol or liquid nitrogen with or without polymethylmethacrylate (PMMA)) in 18 and resection in six. We evaluated the rate of complications and recurrence as well as the factors that influenced their functional outcome. At a mean follow-up of 7.9 years (2 to 26) the rate of recurrence was 50% (n = 3) in those patients treated with isolated curettage, 22% (n = 4) in those treated with curettage plus adjuvants and 17% (n = 1) in those treated with resection (p = 0.404). The only complication was pain in one patient, which resolved after surgical removal of remnants of PMMA. We could not identify any individual factors associated with a higher rate of complications or recurrence. The mean post-operative Musculoskeletal Tumor Society scores were slightly higher after intra-lesional treatment including isolated curettage and curettage plus adjuvants (29 (20 to 30)) compared with resection (25 (15 to 30)) (p = 0.091). Repeated curettage with adjuvants eventually resulted in the cure for all patients and is therefore a reasonable treatment for both primary and recurrent GCT of the small bones of the hands and feet. Cite this article: Bone Joint J 2013;95-B:838–45


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1410 - 1416
1 Oct 2013
Gebert C Wessling M Gosheger G Aach M Streitbürger A Henrichs MP Dirksen U Hardes J

To date, all surgical techniques used for reconstruction of the pelvic ring following supra-acetabular tumour resection produce high complication rates. We evaluated the clinical, oncological and functional outcomes of a cohort of 35 patients (15 men and 20 women), including 21 Ewing’s sarcomas, six chondrosarcomas, three sarcomas not otherwise specified, one osteosarcoma, two osseous malignant fibrous histiocytomas, one synovial cell sarcoma and one metastasis. The mean age of the patients was 31 years (8 to 79) and the latest follow-up was carried out at a mean of 46 months (1.9 to 139.5) post-operatively.

We undertook a functional reconstruction of the pelvic ring using polyaxial screws and titanium rods. In 31 patients (89%) the construct was encased in antibiotic-impregnated polymethylmethacrylate. Preservation of the extremities was possible for all patients. The survival rate at three years was 93.9% (95% confidence interval (CI) 77.9 to 98.4), at five years it was 82.4% (95% CI 57.6 to 93.4). For the 21 patients with Ewing’s sarcoma it was 95.2% (95% CI 70.7 to 99.3) and 81.5% (95% CI 52.0 to 93.8), respectively. Wound healing problems were observed in eight patients, deep infection in five and clinically asymptomatic breakage of the screws in six. The five-year implant survival was 93.3% (95% CI 57.8 to 95.7). Patients were mobilised at a mean of 3.5 weeks (1 to 7) post-operatively. A post-operative neurological defect occurred in 12 patients. The mean Musculoskeletal Tumor Society score at last available follow-up was 21.2 (10 to 27).

This reconstruction technique is characterised by simple and oncologically appropriate applicability, achieving high primary stability that allows early mobilisation, good functional results and relatively low complication rates.

Cite this article: Bone Joint J 2013;95-B:1410–16.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1078 - 1082
1 Aug 2009
Kang HG Roh YW Kim HS

We have developed a hollow perforated cannulated screw. One or more of these was implanted percutaneously in 11 patients with an osteolytic metastasis in the femoral neck and multiple metastases elsewhere. They were supplemented by one or two additional standard 6.5 mm cannulated screws in nine patients. Polymethylmethacrylate bone cement was injected through the screw into the neck of the femur using small syringes, as in vertebroplasty. The mean amount of cement injected was 23.2 ml (17 to 30). Radiotherapy was started on the fourth post-operative day and chemotherapy, on average, was resumed a day later.

Good structural stability and satisfactory relief from pain were achieved in all the patients. This technique may be useful in the palliation of metastases in the femoral neck.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 142 - 145
1 Jan 2010
Spencer SJ Holt G Clarke JV Mohammed A Leach WJ Roberts JLB

The humerus is a common site for skeletal metastases in the adult. Surgical stabilisation of such lesions is often necessary to relieve pain and restore function. These procedures are essentially palliative and should therefore provide effective relief from pain for the remainder of the patient’s life without the need for further surgical intervention.

We report a retrospective analysis of 35 patients (37 nails) with symptomatic metastases in the shaft of the humerus which were treated by locked, antegrade nailing. There were 27 true fractures (73.0%) and ten painful deposits (27.0%). Relief from pain was excellent in four (11.4%), good in 29 (82.9%) and fair in two (5.7%) on discharge. Function was improved in all but one patient. One case of palsy of the radial nerve was noted. The mean postoperative survival was 7.1 months (0.2 to 45.5) which emphasises the poor prognosis in this group of patients. There were no failures of fixation and no case in which further surgery was required.

Antegrade intramedullary nailing is an effective means of stabilising the humerus for the palliative treatment of metastases. It relieves pain and restores function to the upper limb with low attendant morbidity.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 361 - 365
1 Mar 2007
von Steyern FV Kristiansson I Jonsson K Mannfolk P Heineg̊rd D Rydholm A

We reviewed nine patients at a mean period of 11 years (6 to 16) after curettage and cementing of a giant-cell tumour around the knee to determine if there were any long-term adverse effects on the cartilage. Plain radiography, MRI, delayed gadolinium-enhanced MRI of the cartilage and measurement of the serum level of cartilage oligomeric matrix protein were carried out. The functional outcome was evaluated using the Lysholm knee score.

Each patient was physically active and had returned to their previous occupation. Most participated in recreational sports or exercise.

The mean Lysholm knee score was 92 (83 to 100). Only one patient was found to have cartilage damage adjacent to the cement. This patient had a history of intra-articular fracture and local recurrence, leading to degenerative changes.

Interpretation of the data obtained from delayed gadolinium-enhanced MRI of the cartilage was difficult, with variation in the T1 values which did not correlate with the clinical or radiological findings. We did not find it helpful in the early diagnosis of degeneration of cartilage. We also found no obvious correlation between the serum cartilage oligomeric matrix protein level and the radiological and MR findings, function, time after surgery and the age of the patient.

In summary, we found no evidence that the long-term presence of cement close to the knee joint was associated with the development of degenerative osteoarthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 790 - 795
1 Jun 2006
Ahlmann ER Menendez LR Kermani C Gotha H

We reviewed retrospectively the results in 211 consecutive patients who had undergone limb salvage for bone neoplasia with endoprosthetic reconstruction of the proximal femur (96), distal femur (78), proximal tibia (30) and total femur (7). Their mean age was 50 years (11 to 86) and the mean follow-up period was 37.3 months (1 to 204). A total of 35 (16.6%) prostheses failed. Overall, implant survival was 78% (95% confidence interval (CI) 0.29 to 0.54) at five years, 60% (95% CI 0.93 to 2.35) at ten years and 60% (95% CI 1.27 to 3.88) at 15 years. Survivorship of the limb was 97.6% (95% CI 1.73 to 3.35) at ten years. The gender, age, diagnosis and location of the tumour were not prognostic variables for failure. Modular endoprosthetic replacement in the lower limb is a durable long-term reconstructive option, with the implants generally outlasting the patient.