Aims. We performed a retrospective, comparative study of elderly patients
with an increased risk from anaesthesia who had undergone either
anterior screw fixation (ASF) or halo vest immobilisation (HVI)
for a type II
We have reviewed 81 patients with fractures of the odontoid process treated between May 1983 and July 1997, by anterior screw fixation. There were 29 patients with Anderson and D’Alonzo type-II fractures and 52 with type III. Roy-Camille’s classification identified the direction and instability of the fracture. Operative fixation was carried out on 48 men and 33 women with a mean age of 57 years. Associated injuries of the cervical spine were present in 15 patients, neurological signs in 13, and 18 had an Injury Severity Score of more than 15. Nine patients died and 11 were lost to follow-up. Of 61 patients, 56 (92%) achieved bony union at an average of 14.1 weeks. Two patients required a secondary posterior fusion after failure of the index operation. A full range of movement was restored in 43 patients; only six had a limitation of movement greater than 25%. We conclude that anterior screw fixation is effective and practicable in the treatment of fractures of the dens.
Fractures of the odontoid peg are common spinal
injuries in the elderly. This study compares the survivorship of
a cohort of elderly patients with an isolated fracture of the odontoid
peg versus that of patients who have sustained
a fracture of the hip or wrist. A six-year retrospective analysis
was performed on all patients aged >
65 years who were admitted
to our spinal unit with an isolated fracture of the odontoid peg.
A Kaplan–Meier table was used to analyse survivorship from the date
of fracture, which was compared with the survivorship of similar
age-matched cohorts of 702 consecutive patients with a fracture
of the hip and 221 consecutive patients with a fracture of the wrist. A total of 32 patients with an isolated
Rates of mortality as high as 25% to 30% have been described
following fractures of the odontoid in the elderly population. The
aim of this study was to examine whether easily identifiable variables
present on admission are associated with mortality. A consecutive series of 83 elderly patients with a fracture of
the odontoid following a low-impact injury was identified retrospectively.
Data that were collected included demographics, past medical history
and the results of blood tests on admission. Radiological investigations
were used to assess the Anderson and D’Alonzo classification and
displacement of the fracture. The mean age was 82.9 years (65 to
101). Most patients (66; 79.5%) had a type 2 fracture. An associated
neurological deficit was present in 11 (13.3%). All were treated
conservatively; 80 (96.4%) with a hard collar and three (3.6%) with
halo vest immobilisation.Aims
Patients and Methods
We reviewed the outcome of a retrospective case series of eight patients with atlantoaxial instability who had been treated by percutaneous anterior transarticular screw fixation and grafting under image-intensifier guidance between December 2005 and June 2008. The mean follow-up was 19 months (8 to 27). All eight patients had a solid C1–2 fusion. There were no breakages or displacement of screws. All the patients with pre-operative neck pain had immediate relief from their symptoms or considerable improvement. There were no major complications. Our preliminary clinical results suggest that percutaneous anterior transarticulation screw fixation is technically feasible, safe, useful and minimally invasive when using the appropriate instruments allied to intra-operative image intensification, and by selecting the correct puncture point, angle and depth of insertion.
There are many causes of paraspinal muscle weakness which give rise to the dropped-head syndrome. In the upper cervical spine the central portion of the spinal cord innervates the cervical paraspinal muscles. Dropped-head syndrome resulting from injury to the central spinal cord at this level has not previously been described. We report two patients who were treated acutely for this condition. Both presented with weakness in the upper limbs and paraspinal cervical musculature after a fracture of C2. Despite improvement in the strength of the upper limbs, the paraspinal muscle weakness persisted in both patients. One ultimately underwent cervicothoracic fusion to treat her dropped-head syndrome. While the cause of the dropped-head syndrome cannot be definitively ascribed to the injuries to the spinal cord, this pattern is consistent with the known patho-anatomical mechanisms of both injury to the central spinal cord and dropped-head syndrome.
Transarticular screw fixation with autograft
is an established procedure for the surgical treatment of atlantoaxial instability.
Removal of the posterior arch of C1 may affect the rate of fusion.
This study assessed the rate of atlantoaxial fusion using transarticular
screws with or without removal of the posterior arch of C1. We reviewed
30 consecutive patients who underwent atlantoaxial fusion with a
minimum follow-up of two years. In 25 patients (group A) the posterior
arch of C1 was not excised (group A) and in five it was (group B).
Fusion was assessed on static and dynamic radiographs. In selected
patients CT imaging was also used to assess fusion and the position
of the screws. There were 15 men and 15 women with a mean age of
51.2 years (23 to 77) and a mean follow-up of 7.7 years (2 to 11.6).
Stable union with a solid fusion or a stable fibrous union was achieved
in 29 patients (97%). In Group A, 20 patients (80%) achieved a solid
fusion, four (16%) a stable fibrous union and one (4%) a nonunion.
In Group B, stable union was achieved in all patients, three having
a solid fusion and two a stable fibrous union. There was no statistically
significant difference between the status of fusion in the two groups.
Complications were noted in 12 patients (40%); these were mainly
related to the screws, and included malpositioning and breakage.
The presence of an intact or removed posterior arch of C1 did not
affect the rate of fusion in patients with atlantoaxial instability
undergoing C1/C2 fusion using transarticular screws and autograft. Cite this article: