Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1557 - 1566
1 Nov 2012
Jameson SS Kyle J Baker PN Mason J Deehan DJ McMurtry IA Reed MR

United Kingdom National Institute for Health and Clinical Excellence guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractures of the femoral neck in cognitively intact patients, who were independently mobile prior to the injury. This study aimed to analyse the risk factors associated with revision of the implant and mortality following THR, and to quantify risk. National Joint Registry data recording a THR performed for acute fracture of the femoral neck between 2003 and 2010 were analysed. Cox proportional hazards models were used to investigate the extent to which risk of revision was related to specific covariates. Multivariable logistic regression was used to analyse factors affecting peri-operative mortality (< 90 days). A total of 4323 procedures were studied. There were 80 patients who had undergone revision surgery at the time of censoring (five-year revision rate 3.25%, 95% confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients died within 90 days. After adjusting for patient and surgeon characteristics, an increased risk of revision was associated with the use of cementless prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021). Revision was independent of bearing surface and head size. The risk of mortality within 90 days was significantly increased with higher American Society of Anesthesiologists (ASA) grade (grade 3: odds ratio (OR) 4.04, p < 0.001; grade 4/5: OR 20.26, p < 0.001; both compared with grades 1/2) and older age (≥ 75 years: OR 1.65, p = 0.025), but reduced over the study period (9% relative risk reduction per year). THR is a good option in patients aged < 75 years and with ASA 1/2. Cementation of the femoral component does not adversely affect peri-operative mortality but improves survival of the implant in the mid-term when compared with cementless femoral components. There are no benefits of using head sizes > 28 mm or bearings other than metal-on-polyethylene. More research is required to determine the benefits of THR over hemiarthroplasty in older patients and those with ASA grades > 2


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 987 - 996
1 Aug 2022

Aims

The aim of this study was to describe the demographic details of patients who sustain a femoral periprosthetic fracture (PPF), the epidemiology of PPFs, PPF characteristics, and the predictors of PPF types in the UK population.

Methods

This is a multicentre retrospective cohort study including adult patients presenting to hospital with a new PPF between 1 January 2018 and 31 December 2018. Data collected included: patient characteristics, comorbidities, anticoagulant use, social circumstances, level of mobility, fracture characteristics, Unified Classification System (UCS) type, and details of the original implant. Descriptive analysis by fracture location was performed, and predictors of PPF type were assessed using mixed-effects logistic regression models.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 894 - 901
1 Jul 2022
Aebischer AS Hau R de Steiger RN Holder C Wall CJ

Aims

The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR).

Methods

Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1223 - 1231
1 Sep 2017
Tucker A Donnelly KJ McDonald S Craig J Foster AP Acton JD

Aims

We reviewed all patients who sustained a fracture of the hip and were treated in Northern Ireland over a period of 15 years to identify trends in incidence, the demographics of the patients, the rates of mortality, the configuration of the fracture and the choice of implant.

Patients and Methods

Since 01 January 2001 data about every fracture of the hip sustained in an adult have been collected centrally in Northern Ireland. All adults with such a fracture between 2000 and 2015 were included in the study. Temporal changes in their demographics, the mode of treatment, and outcomes including mortality were analysed.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 658 - 664
1 May 2011
Karantana A Boulton C Bouliotis G Shu KSS Scammell BE Moran CG

We examined prospectively collected data from 6782 consecutive hip fractures and identified 327 fractures in 315 women aged ≤65 years. We report on their demographic characteristics, treatment and outcome and compare them with a cohort of 4810 hip fractures in 4542 women aged > 65 years.

The first significant increase in age-related incidence of hip fracture was at 45, rather than 50, which is when screening by the osteoporosis service starts in most health areas. Hip fractures in younger women are sustained by a population at risk as a result of underlying disease. Mortality of younger women with hip fracture was 46 times the background mortality of the female population. Smoking had a strong influence on the relative risk of ‘early’ (≤ 65 years of age) fracture.

Lag screw fixation was the most common method of operative treatment. General complication rates were low, as were re-operation rates for cemented prostheses. Kaplan-Meier implant survivorship of displaced intracapsular fractures treated by reduction and lag screw fixation was 71% (95% confidence interval 56 to 81) at five years. The best form of treatment remains controversial.