Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 965 - 968
1 Jul 2005
Stannard JP Singhania AK Lopez-Ben RR Anderson ER Farris RC Volgas DA McGwin GR Alonso JE

We report the incidence and location of deep-vein thrombosis in 312 patients who had sustained high-energy, skeletal trauma. They were investigated using magnetic resonance venography and Duplex ultrasound.

Despite thromboprophylaxis, 36 (11.5%) developed venous thromboembolic disease with an incidence of 10% in those with non-pelvic trauma and 12.2% in the group with pelvic trauma. Of patients who developed deep-vein thrombosis, 13 of 27 in the pelvic group (48%) and only one of nine in the non-pelvic group (11%) had a definite pelvic deep-vein thrombosis. When compared with magnetic resonance venography, ultrasound had a false-negative rate of 77% in diagnosing pelvic deep-vein thrombosis. Its value in the pelvis was limited, although it was more accurate than magnetic resonance venography in diagnosing clots in the lower limbs. Additional screening may be needed to detect pelvic deep-vein thrombosis in patients with pelvic or acetabular fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1117 - 1122
1 Aug 2005
Fuchs S Heyse T Rudofsky G Gosheger G Chylarecki C

There is a high risk of venous thromboembolism when patients are immobilised following trauma. The combination of low-molecular-weight heparin (LMWH) with graduated compression stockings is frequently used in orthopaedic surgery to try and prevent this, but a relatively high incidence of thromboembolic events remains. Mechanical devices which perform continuous passive motion imitate contractions and increase the volume and velocity of venous flow.

In this study 227 trauma patients were randomised to receive either treatment with the Arthroflow device and LMWH or only with the latter. The Arthroflow device passively extends and plantarflexes the feet. Patients were assessed initially by venous-occlusion plethysmography, compression ultrasonography and continuous wave Doppler, which were repeated weekly without knowledge of the category of randomisation. Those who showed evidence of deep-vein thrombosis underwent venography for confirmation. The incidence of deep-vein thrombosis was 25% in the LMWH group compared with 3.6% in those who had additional treatment with the Arthroflow device (p < 0.001). There were no substantial complications or problems of non-compliance with the Arthroflow device. Logistic regression analysis of the risk factors of deep-vein thrombosis showed high odds ratios for operation (4.1), immobilisation (4.3), older than 40 years of age (2.8) and obesity (2.2).