Advertisement for orthosearch.org.uk
Results 1 - 20 of 95
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 893 - 898
1 Jul 2008
Levy O Relwani J Zaman T Even T Venkateswaran B Copeland S

The aim of this study was to define the microcirculation of the normal rotator cuff during arthroscopic surgery and investigate whether it is altered in diseased cuff tissue. Blood flow was measured intra-operatively by laser Doppler flowmetry. We investigated six different zones of each rotator cuff during the arthroscopic examination of 56 consecutive patients undergoing investigation for impingement, cuff tears or instability; there were 336 measurements overall. The mean laser Doppler flowmetry flux was significantly higher at the edges of the tear in torn cuffs (43.1, 95% confidence interval (CI) 37.8 to 48.4) compared with normal cuffs (32.8, 95% CI 27.4 to 38.1; p = 0.0089). It was significantly lower across all anatomical locations in cuffs with impingement (25.4, 95% CI 22.4 to 28.5) compared with normal cuffs (p = 0.0196), and significantly lower in cuffs with impingement compared with torn cuffs (p < 0.0001). Laser Doppler flowmetry analysis of the rotator cuff blood supply indicated a significant difference between the vascularity of the normal and the pathological rotator cuff. We were unable to demonstrate a functional hypoperfusion area or so-called ‘critical zone’ in the normal cuff. The measured flux decreases with advancing impingement, but there is a substantial increase at the edges of rotator cuff tears. This might reflect an attempt at repair


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 633 - 638
1 May 2007
Matthews TJW Smith SR Peach CA Rees JL Urban JPG Carr AJ

We have undertaken an in vivo assessment of the tissue metabolism and cellular activity in torn tendons of the rotator cuff. Cellular oxygen consumption was measured in 13 patients undergoing mini-open repair of small, medium, large and massive full-thickness tears. Measurements were also taken from three control patients who were undergoing open stabilisation of the shoulder with grossly normal tendons. The level of oxygen and nitrous oxide was measured amperometrically using silver needle microelectrodes at the apex of the tear and 1.5 cm from its edge. With nitrous oxide indicating the degree of perfusion, oxygen consumption was calculated at each location to reflect cellular activity.

All of the torn tendons had lower levels of cellular activity than the control group. This activity was lower still in the tissue nearest to the edge of the tear with the larger tears showing the lowest activity. This indicated reduced levels of tissue metabolism and infers a reduction in tendon viability.

Our findings suggest that surgical repair of torn tendons of the rotator-cuff should include the more proximal, viable tissue, and may help to explain the high rate of re-rupture seen in larger tears.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 517 - 522
1 Apr 2013
Henry PDG Dwyer T McKee MD Schemitsch EH

Latissimus dorsi tendon transfer (LDTT) is technically challenging. In order to clarify the local structural anatomy, we undertook a morphometric study using six complete cadavers (12 shoulders). Measurements were made from the tendon to the nearby neurovascular structures with the arm in two positions: flexed and internally rotated, and adducted in neutral rotation. The tendon was then transferred and measurements were taken from the edge of the tendon to a reference point on the humeral head in order to assess the effect of a novel two-stage release on the excursion of the tendon. With the shoulder flexed and internally rotated, the mean distances between the superior tendon edge and the radial nerve, brachial artery, axillary nerve and posterior circumflex artery were 30 mm (26 to 34), 28 mm (17 to 39), 21 mm (12 to 28) and 15 mm (10 to 21), respectively. The mean distance between the inferior tendon edge and the radial nerve, brachial artery and profunda brachii artery was 18 mm (8 to 27), 22 mm (15 to 32) and 14 mm (7 to 21), respectively. Moving the arm to a neutral position reduced these distances. A mean of 15 mm (8 to 21) was gained from a standard soft-tissue release, and 32 mm (20 to 45) from an extensile release. These figures help to define further the structural anatomy of this region and the potential for transfer of the latissimus dorsi tendon. Cite this article: Bone Joint J 2013;95-B:517–22


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 517 - 522
1 Apr 2012
Jeon I Chun J Lee C Yoon J Kim P An K Morrey BF Shin H

The zona conoidea comprises the area of the lateral trochlear ridge of the humerus. The purpose of this study is to reintroduce this term ‘zona conoidea’ to the discussion of the human elbow and to investigate its significance in the development of osteoarthritis of the elbow. The upper extremities of 12 cadavers were prepared. With the forearm in neutral, pronation and supination, the distance between the bevel of the radial head and zona conoidea was inspected. A total of 12 healthy volunteers had a CT scan. The distance between the zona conoidea and the bevelled rim of the radial head was measured in these positions. In the anatomical specimens, early osteo-arthritic changes were identified in the posteromedial bevelled rim of the radial head, and the corresponding zona conoidea in supination. Measurement in the CT study showed that in full supination, the distance between the bevel of the radial head and the zona conoidea was at a minimum. This study suggests that the significant contact between the bevel of the radial head and the zona conoidea in supination is associated with the initiation of osteoarthritis of the elbow in this area


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 466 - 473
1 Apr 2008
Dawson J Doll H Boller I Fitzpatrick R Little C Rees J Jenkinson C Carr AJ

We developed a questionnaire to assess patient-reported outcome after surgery of the elbow from interviews with patients. Initially, 17 possible items with five response options were included. A prospective study of 104 patients (107 elbow operations) was carried out to analyse the underlying factor structure, dimensionality, internal and test-retest reliability, construct validity and responsiveness of the questionnaire items. This was compared with the Mayo Elbow performance score clinical scale, the Disabilities of the Arm, Shoulder and Hand questionnaire, and the Short-Form (SF-36) General Health Survey. In total, five questions were considered inappropriate, which resulted in the final 12-item questionnaire, which has been referred to as the Oxford elbow score. This comprises three unidimensional domains, ‘elbow function’, ‘pain’ and ‘social-psychological’; with each domain comprising four items with good measurement properties. This new 12-item Oxford elbow score is a valid measure of the outcome of surgery of the elbow


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 942 - 948
1 Jul 2011
Chaudhury S Holland C Vollrath F Carr AJ

This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis. Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity. Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p < 0.01). Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by conventional methods of tensile testing. These methods could be employed to investigate other musculoskeletal tissues. This pilot study provides some insight into mechanisms that might contribute to the failure of repair surgery, and with future application could help direct the most appropriate treatment for specific rotator cuff tears


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 780 - 782
1 Sep 1996
Söderberg TA

We report two cases of bilateral chronic exertional compartment syndrome (CCS) in the forearmand hand. Measurement of the intramuscular pressure was useful for diagnosis. These two cases illustrate that bilateral CCS should be suspected in patients complaining of bilateral exercise-induced pain in the anconeus muscle, the forearms, the thenar and hypothenar regions and in the first dorsal interosseous muscle. Fasciotomy relieved the pain in both cases


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 70 - 73
1 Jan 2004
Hattori Y Doi K Dhawan V Ikeda K Kaneko K Ohi R

The purpose of this study is to investigate the diagnostic value of evoked spinal cord potentials (ESCPs) and choline acetyltransferase (CAT) activity during exploration of injuries to the brachial plexus. We assessed 25 spinal roots in 19 patients. The results of the two investigations were consistent in all except two roots. Although assessment of ESCPs is easy and quick, it mainly records the nerve potentials along the sensory pathway. Although measurement of CAT activity needs a specimen of the nerve and the availability of a radioisotope laboratory, it gives direct information regarding the motor function of ventral spinal roots. These two techniques should be complementary to each other in order to achieve a more accurate diagnosis


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 852 - 855
1 Aug 2003
Melikyan EY Shahin E Miles J Bainbridge LC

The efficacy of extracorporeal shock-wave therapy for tennis elbow was investigated using a single fractionated dosage in a randomised, double-blind study. Outcomes were assessed using the Disabilities of Arm, Shoulder and Hand questionnaire, measurements of grip strength, levels of pain, analgesic usage and the rate of progression to surgery. Informed consent was obtained before patients were randomised to either the treatment or placebo group. In the final assessment, 74 patients (31 men and 43 women) with a mean age of 43.4 years (35 to 71), were included. None of the outcome measures showed a statistically significant difference between the treatment and control groups (p > 0.05). All patients improved significantly over time, regardless of treatment. Our study showed no evidence that extracorporeal shock-wave therapy for tennis elbow is better than placebo


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 614 - 618
1 May 2008
Ruch DS Shen J Chloros GD Krings E Papadonikolakis A

Contracture of the collateral ligaments is considered to be an important factor in post-traumatic stiffness of the elbow. We reviewed the results of isolated release of the medial collateral ligament in a series of 14 patients with post-traumatic loss of elbow flexion treated between 1998 and 2002. There were nine women and five men with a mean age of 45 years (17 to 76). They were reviewed at a mean follow-up of 25 months (9 to 48). The operation was performed through a longitudinal posteromedial incision centred over the ulnar nerve. After decompression of the ulnar nerve, release of the medial collateral ligament was done sequentially starting with the posterior bundle and the transverse component of the ligament, with measurement of the arc of movement after each step. If full flexion was not achieved the posterior half of the anterior bundle of the medial collateral ligament was released. At the latest follow-up, the mean flexion of the elbow improved significantly from 96° (85° to 115°) pre-operatively to 130° (110° to 150°) at final follow-up (p = 0.001). The mean extension improved significantly from 43° (5° to 90°) pre-operatively to 22° (5° to 40°) at final follow-up (p = 0.003). There was a significant improvement in the functional outcome. The mean Broberg and Morrey score increased from a mean of 54 points (29.5 to 85) pre-operatively to 87 points (57 to 99) at final follow-up (p < 0.001). All the patients had normal elbow stability. Our results indicate that partial surgical release of the medial collateral ligament is associated with improved range of movement of the elbow in patients with post-traumatic stiffness, but was less effective in controlling pain


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 229 - 232
1 Mar 1996
Conboy VB Morris RW Kiss J Carr AJ

We have analysed the Constant-Murley (1987) assessment for 25 patients with shoulder pathology. We found the score easy to use, with low inter- and intraobserver errors, but sufficiently imprecise in repeated measurements to give concern in its use for clinical follow-up of patients. We have calculated 95% confidence limits for a single assessment to be within 16 to 20 points in most cases. In addition, we found that all our subjects with instability as their main problem scored within five points of the maximum; this suggests that the scoring method may need to be revised for use on these patients


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1111 - 1115
1 Nov 2002
Horlock N Belcher HJCR

We randomly selected 39 patients undergoing excision of the trapezium for osteoarthritis of the first carpometacarpal joint into two groups, with mobilisation either at one or at four weeks after operation. The patients were reviewed at a median of six months (6 to 8). The clinical details, the severity of the disease and the preoperative clinical measurements of both groups were similar. Excision of the trapezium resulted in significant improvement in objective and subjective function. Comparison of the outcomes of the two groups showed no differences except that patients found early mobilisation significantly more convenient. Although there was no significant difference in the range of movement between the groups, there was a small loss of movement at the metacarpophalangeal joint in the late mobilisation group. Our findings show that simple excision of the trapezium is an effective procedure for patients with carpometacarpal osteoarthritis of the thumb and that prolonged splintage is neither necessary nor desirable


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 420 - 426
1 May 1999
Dawson J Fitzpatrick R Carr A

We have developed a 12-item questionnaire for completion by patients presenting with shoulder instability. A prospective study of 92 patients was undertaken involving two assessments, approximately six months apart, performed in an outpatient department. Each patient completed the new questionnaire and the SF36 form. An orthopaedic surgeon completed the Constant shoulder score and the Rowe assessment. The new questionnaire and the Rowe clinical score each achieved a large standardised effect size (≥0.8) and compared favourably with relevant items on the SF36. By contrast, the Constant score barely registered any effect, confirming that it may be relatively insensitive to changes in clinical status for this particular condition. The questionnaire provides a measurement of outcome for shoulder instability which is short, practical, reliable, valid and sensitive to changes of clinical importance


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 235 - 240
1 Mar 2001
Dias JJ Bhowal B Wildin CJ Thompson JR

The different attributes of the Patient Evaluation Measure (PEM) questionnaire were investigated in 80 patients with a fracture of the scaphoid. Assessments were made at 2, 8, 12, 26 and 52 weeks. Reliability was assessed by measurement of the internal consistency of the different questions in 275 completed PEM forms. Cronbach’s alpha, which needs to lie between 0.7 and 0.9, was 0.9 for the PEM. Pain, tenderness, swelling, wrist movement and grip strength correlated with the PEM score confirming the validity of the assessment. Changes in the different variables between visits correlated significantly with changes in the PEM score; its effect size and standardised response mean were comparable to those of grip strength and movement, confirming the responsiveness of this questionnaire. Gender, dominance and the side injured did not influence the scores. Older patients had a poorer outcome as assessed by the score which appeared to be a true effect and not age bias. Our study confirmed that the PEM is a reliable, valid and responsive instrument in assessing outcomes of disorders of the hand


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 680 - 683
1 Jul 2002
Kitoh H Kitakoji T Kurita K Katoh M Takamine Y

Lack of full extension of the elbow is a common abnormality in patients with achondroplasia. We studied 23 patients (41 elbows) clinically and radiologically. Extension of the elbow was assessed clinically and the angle of posterior bowing of the distal humerus was measured from lateral radiographs. There was limited extension of the elbow in 28 (68.3%) and the mean loss of extension was 13.1°. Posterior bowing of the humerus was seen in all elbows with a mean angle of 17.0°. There was a positive correlation between these two measurements. Posterior bowing greater than 20° caused a loss of full elbow extension. Posterior dislocation of the radial head was seen in nine elbows (22.0%). The mean loss of extension of the elbows was 28.7° which was significantly greater than that of these elbows in which the head was not dislocated (8.7°), although posterior bowing was not significantly different between these two groups (19.3° and 16.3°). Posterior bowing of the distal humerus is a principal cause of loss of extension of the elbow. Posterior dislocation of the radial head causes further limitation of movement in the more severely affected joints


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 519 - 525
1 Apr 2016
Lees DA Penny JB Baker P

Aims

The aim of this study was to compare the pain caused by the application of a tourniquet after exsanguination of the upper limb with that occurring after simple elevation.

Patients and Methods

We used 26 healthy volunteers (52 arms), each of whom acted as their own matched control.

The primary outcome measure was the total pain experienced by each volunteer while the tourniquet was inflated for 20 minutes. This was calculated as the area under the pain curve for each individual subject. Secondary outcomes were pain at each time point; the total pain experienced during the recovery phase; the ability to tolerate the tourniquet and the time for full recovery after deflation of the tourniquet.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 530 - 535
1 Apr 2013
Roche CP Marczuk Y Wright TW Flurin P Grey S Jones R Routman HD Gilot G Zuckerman JD

This study provides recommendations on the position of the implant in reverse shoulder replacement in order to minimise scapular notching and osteophyte formation. Radiographs from 151 patients who underwent primary reverse shoulder replacement with a single prosthesis were analysed at a mean follow-up of 28.3 months (24 to 44) for notching, osteophytes, the position of the glenoid baseplate, the overhang of the glenosphere, and the prosthesis scapular neck angle (PSNA).

A total of 20 patients (13.2%) had a notch (16 Grade 1 and four Grade 2) and 47 (31.1%) had an osteophyte. In patients without either notching or an osteophyte the baseplate was found to be positioned lower on the glenoid, with greater overhang of the glenosphere and a lower PSNA than those with notching and an osteophyte. Female patients had a higher rate of notching than males (13.3% vs 13.0%) but a lower rate of osteophyte formation (22.9% vs 50.0%), even though the baseplate was positioned significantly lower on the glenoid in females (p = 0.009) and each had a similar mean overhang of the glenosphere.

Based on these findings we make recommendations on the placement of the implant in both male and female patients to avoid notching and osteophyte formation.

Cite this article: Bone Joint J 2013;95-B:530–5.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 809 - 814
1 Jun 2013
Park HY Yoon JO Jeon IH Chung HW Kim JS

This study was performed to determine whether pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient to achieve bony union and restore alignment in scaphoid nonunion. A total of 65 patients who underwent cancellous bone graft and K-wire fixation were included in this study. The series included 61 men and four women with a mean age of 34 years (15 to 72) and mean delay to surgery of 28.7 months (3 to 240). The patients were divided into an unstable group (A) and stable group (B) depending on the pre-operative radiographs. Unstable nonunion was defined as a lateral intrascaphoid angle > 45°, or a radiolunate angle > 10°. There were 34 cases in group A and 31 cases in group B. Bony union was achieved in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B (p = 0.439). Comparison of the post-operative radiographs between the two groups showed no significant differences in lateral intrascaphoid angle (p = 0.657) and scaphoid length (p = 0.670) and height (p = 0.193). The radiolunate angle was significantly different (p = 0.020) but the mean value in both groups was < 10°. Comparison of the dorsiflexion and palmar flexion of movement of the wrist and the mean Mayo wrist score at the final clinical visit in each group showed no significant difference (p = 0.190, p = 0.587 and p = 0.265, respectively). Cancellous bone graft and K-wire fixation were effective in the treatment of stable and unstable scaphoid nonunion.

Cite this article: Bone Joint J 2013;95-B:809–14.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 935 - 941
1 Jul 2013
Moor BK Bouaicha S Rothenfluh DA Sukthankar A Gerber C

We hypothesised that a large acromial cover with an upwardly tilted glenoid fossa would be associated with degenerative rotator cuff tears (RCTs), and conversely, that a short acromion with an inferiorly inclined glenoid would be associated with glenohumeral osteoarthritis (OA). This hypothesis was tested using a new radiological parameter, the critical shoulder angle (CSA), which combines the measurements of inclination of the glenoid and the lateral extension of the acromion (the acromion index).

The CSA was measured on standardised radiographs of three groups: 1) a control group of 94 asymptomatic shoulders with normal rotator cuffs and no OA; 2) a group of 102 shoulders with MRI-documented full-thickness RCTs without OA; and 3) a group of 102 shoulders with primary OA and no RCTs noted during total shoulder replacement. The mean CSA was 33.1° (26.8° to 38.6°) in the control group, 38.0° (29.5° to 43.5°) in the RCT group and 28.1° (18.6° to 35.8°) in the OA group. Of patients with a CSA > 35°, 84% were in the RCT group and of those with a CSA < 30°, 93% were in the OA group.

We therefore concluded that primary glenohumeral OA is associated with significantly smaller degenerative RCTs with significantly larger CSAs than asymptomatic shoulders without these pathologies. These findings suggest that individual quantitative anatomy may imply biomechanics that are likely to induce specific types of degenerative joint disorders.

Cite this article: Bone Joint J 2013;95-B:935–41.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 952 - 959
1 Jul 2013
Cai X Yan S Giddins G

Most patients with a nightstick fracture of the ulna are treated conservatively. Various techniques of immobilisation or early mobilisation have been studied. We performed a systematic review of all published randomised controlled trials and observational studies that have assessed the outcome of these fractures following above- or below-elbow immobilisation, bracing and early mobilisation. We searched multiple electronic databases, related bibliographies and other studies. We included 27 studies comprising 1629 fractures in the final analysis. The data relating to the time to radiological union and the rates of delayed union and nonunion could be pooled and analysed statistically.

We found that early mobilisation produced the shortest radiological time to union (mean 8.0 weeks) and the lowest mean rate of nonunion (0.6%). Fractures treated with above- or below-elbow immobilisation and braces had longer mean radiological times to union (9.2 weeks, 9.2 weeks and 8.7 weeks, respectively) and higher mean rates of nonunion (3.8%, 2.1% and 0.8%, respectively). There was no statistically significant difference in the rate of non- or delayed union between those treated by early mobilisation and the three forms of immobilisation (p = 0.142 to p = 1.000, respectively). All the studies had significant biases, but until a robust randomised controlled trial is undertaken the best advice for the treatment of undisplaced or partially displaced nightstick fractures appears to be early mobilisation, with a removable forearm support for comfort as required.

Cite this article: Bone Joint J 2013;95-B:952–9.