Advertisement for orthosearch.org.uk
Results 1 - 20 of 699
Results per page:
The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 72 - 80
1 Jan 2025
Blyth MJG Clement ND Choo XY Doonan J MacLean A Jones BG

Aims. The aim of this study was to perform an incremental cost-utility analysis and assess the impact of differential costs and case volume on the cost-effectiveness of robotic arm-assisted medial unicompartmental knee arthroplasty (rUKA) compared to manual (mUKA). Methods. Ten-year follow-up of patients who were randomized to rUKA (n = 64) or mUKA (n = 65) was performed. Patients completed the EuroQol five-dimension health questionnaire preoperatively, at three months, and one, two, five, and ten years postoperatively, which was used to calculate quality-adjusted life years (QALY) gained and the incremental cost-effectiveness ratio (ICER). Costs for the index and additional surgery and healthcare costs were calculated. Results. mUKA had a lower survival for reintervention (84.8% (95% CI 76.2 to 93.4); p = 0.001), all-cause revision (88.9% (95% CI 81.3 to 96.5); p = 0.007) and aseptic revision (91.9% (95% CI 85.1 to 98.7); p = 0.023) when compared to the rUKA group at ten years, which was 100%. The rUKA group had a greater QALY gain per patient (mean difference 0.186; p = 0.651). Overall rUKA was the dominant intervention, being cost-saving and more effective with a greater health-related quality of life gain. On removal of infected reinterventions (n = 2), the ICER was £757 (not discounted) and £481 (discounted). When including all reintervention costs, rUKA was cost-saving when more than 100 robotic cases were performed per year. When removing the infected cases, rUKA was cost-saving when undertaking more than 800 robotic cases per year. Conclusion. rUKA had lower reintervention and revision risks at ten years, which was cost-saving and associated with a greater QALY gain, and was the dominant procedure. When removing the cost of infection, which could be a random event, rUKA was a cost-effective intervention with an ICER (£757) which was lower than the willingness-to-pay threshold (£20,000). Cite this article: Bone Joint J 2025;107-B(1):72–80


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 541 - 548
1 May 2022
Zhang J Ng N Scott CEH Blyth MJG Haddad FS Macpherson GJ Patton JT Clement ND

Aims. This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA). Methods. Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta-­Analysis statement. Search terms included “robotic”, “unicompartmental”, “knee”, and “arthroplasty”. Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis. Results. A total of 179 articles were identified from initial screening, of which 14 articles satisfied the inclusion criteria and were included for analysis. The papers analyzed include one on learning curve, five on implant positioning, six on functional outcomes, five on complications, six on survivorship, and three on cost. The learning curve was six cases for operating time and zero for precision. There was consistent evidence of more precise implant positioning with MAKO RAUKA. Meta-analysis demonstrated lower overall complication rates associated with MAKO RAUKA (OR 2.18 (95% confidence interval (CI) 1.06 to 4.49); p = 0.040) but no difference in re-intervention, infection, Knee Society Score (KSS; mean difference 1.64 (95% CI -3.00 to 6.27); p = 0.490), or Western Ontario and McMaster Universities Arthritis Index (WOMAC) score (mean difference -0.58 (95% CI -3.55 to 2.38); p = 0.700). MAKO RAUKA was shown to be a cost-effective procedure, but this was directly related to volume. Conclusion. MAKO RAUKA was associated with improved precision of component positioning but was not associated with improved PROMs using the KSS and WOMAC scores. Future longer-term studies should report functional outcomes, potentially using scores with minimal ceiling effects and survival to assess whether the improved precision of MAKO RAUKA results in better outcomes. Cite this article: Bone Joint J 2022;104-B(5):541–548


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 961 - 970
1 Sep 2023
Clement ND Galloway S Baron YJ Smith K Weir DJ Deehan DJ

Aims. The primary aim was to assess whether robotic total knee arthroplasty (rTKA) had a greater early knee-specific outcome when compared to manual TKA (mTKA). Secondary aims were to assess whether rTKA was associated with improved expectation fulfilment, health-related quality of life (HRQoL), and patient satisfaction when compared to mTKA. Methods. A randomized controlled trial was undertaken, and patients were randomized to either mTKA or rTKA. The primary objective was functional improvement at six months. Overall, 100 patients were randomized, 50 to each group, of whom 46 rTKA and 41 mTKA patients were available for review at six months following surgery. There were no differences between the two groups. Results. There was no difference between rTKA and mTKA groups at six months according to the Western Ontario and McMaster Universities osteoarthritis index (WOMAC) functional score (mean difference (MD) 3.8 (95% confidence interval (CI) -5.6 to 13.1); p = 0.425). There was a greater improvement in the WOMAC pain score at two months (MD 9.5 (95% CI 0.6 to 18.3); p = 0.037) in the rTKA group, although by six months no significant difference was observed (MD 6.7 (95% CI -3.6 to 17.1); p = 0.198). The rTKA group were more likely to achieve a minimal important change in their WOMAC pain score when compared to the mTKA group at two months (n = 36 (78.3%) vs n = 24 (58.5%); p = 0.047) and at six months (n = 40 (87.0%) vs n = 29 (68.3%); p = 0.036). There was no difference in satisfaction between the rTKA group (97.8%; n = 45/46) and the mTKA group (87.8%; n = 36/41) at six months (p = 0.096). There were no differences in EuroQol five-dimension questionnaire (EQ-5D) utility gain (p ≥ 0.389) or fulfilment of patient expectation (p ≥ 0.054) between the groups. Conclusion. There were no statistically significant or clinically meaningful differences in the change in WOMAC function between mTKA and rTKA at six months. rTKA was associated with a higher likelihood of achieving a clinically important change in knee pain at two and six months, but no differences in knee-specific function, patient satisfaction, health-related quality of life, or expectation fulfilment were observed. Cite this article: Bone Joint J 2023;105-B(9):961–970


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1009 - 1020
1 Jun 2021
Ng N Gaston P Simpson PM Macpherson GJ Patton JT Clement ND

Aims. The aims of this systematic review were to assess the learning curve of semi-active robotic arm-assisted total hip arthroplasty (rTHA), and to compare the accuracy, patient-reported functional outcomes, complications, and survivorship between rTHA and manual total hip arthroplasty (mTHA). Methods. Searches of PubMed, Medline, and Google Scholar were performed in April 2020 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “hip”, and “arthroplasty”. The criteria for inclusion were published clinical research articles reporting the learning curve for rTHA (robotic arm-assisted only) and those comparing the implantation accuracy, functional outcomes, survivorship, or complications with mTHA. Results. There were 501 articles initially identified from databases and references. Following full text screening, 17 articles that satisfied the inclusion criteria were included. Four studies reported the learning curve of rTHA, 13 studies reported on implant positioning, five on functional outcomes, ten on complications, and four on survivorship. The meta-analysis showed a significantly greater number of cases of acetabular component placement in the safe zone compared with the mTHA group (95% confidence interval (CI) 4.10 to 7.94; p < 0.001) and that rTHA resulted in a significantly better Harris Hip Score compared to mTHA in the short- to mid-term follow-up (95% CI 0.46 to 5.64; p = 0.020). However, there was no difference in infection rates, dislocation rates, overall complication rates, and survival rates at short-term follow-up. Conclusion. The learning curve of rTHA was between 12 and 35 cases, which was dependent on the assessment goal, such as operating time, accuracy, and team working. Robotic arm-assisted total hip arthroplasty was associated with improved accuracy of component positioning and functional outcome, however no difference in complication rates or survival were observed at short- to mid-term follow-up. Overall, there remains an absence of high-quality level I evidence and cost analysis comparing rTHA and mTHA. Cite this article: Bone Joint J 2021;103-B(6):1009–1020


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1449 - 1456
1 Sep 2021
Kazarian GS Lieberman EG Hansen EJ Nunley RM Barrack RL

Aims

The goal of the current systematic review was to assess the impact of implant placement accuracy on outcomes following total knee arthroplasty (TKA).

Methods

A systematic review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines using the Ovid Medline, Embase, Cochrane Central, and Web of Science databases in order to assess the impact of the patient-reported outcomes measures (PROMs) and implant placement accuracy on outcomes following TKA. Studies assessing the impact of implant alignment, rotation, size, overhang, or condylar offset were included. Study quality was assessed, evidence was graded (one-star: no evidence, two-star: limited evidence, three-star: moderate evidence, four-star: strong evidence), and recommendations were made based on the available evidence.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 256 - 261
1 Feb 2018
Kim W Lee JS Chung HW

Aims. Adjuvant treatment after intralesional curettage for atypical cartilaginous tumours (ACTs) of long bones is widely accepted for extending surgical margins. However, evaluating the isolated effect of adjuvant treatment is difficult, and it is unclear whether not using such adjuvants provides poor oncological outcomes. Hence, we analyzed whether intralesional curettage without cryosurgery or chemical adjuvants provides poor oncological outcomes in patients with an ACT. Patients and Methods. A total of 24 patients (nine men, 15 women) (mean age 45 years; 18 to 62) were treated for ACTs of long bones and followed up for a median of 66 months (interquartile range 50 to 84). All patients were treated with extensive manual curettage and limited burring. Bone cement and grafts were used to fill bone defects in 16 and eight patients, respectively. No chemical adjuvants or cryosurgery were used. Results. No local recurrence was detectable on plain radiographs and MRI or CT images. At the last follow-up, there were no distant metastases or disease-specific deaths. No procedure-related complications or postoperative fractures developed. Conclusion. Intralesional curettage without cryosurgery or chemical adjuvants may provide excellent oncological outcomes for patients with ACTs of long bones, without the risk of complications related to adjuvant use. Our investigation suggests thorough curettage alone is a reasonable treatment option for ACT. However, we acknowledge the limited size of our investigation warrants a multicentre collaborative study to confirm our findings. Cite this article: Bone Joint J 2018;100-B:256–61


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 150 - 150
1 Jan 2002
Laurance M


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 622 - 622
1 May 2002
Spicer DDM


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 465 - 465
1 Apr 2002
Spicer DDM


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 154 - 155
1 Jan 2000
Marston RA


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 3 | Pages 566 - 566
1 Aug 1971
Hicks JH


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 1 | Pages 201 - 201
1 Feb 1970
Newman PH


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 623 - 623
1 May 2004
Horan F


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 152 - 152
1 Jan 2003
Rowley DI


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 344 - 344
1 Mar 1997
Taylor B


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 169 - 169
1 Jan 1996
Laurence M


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 2 | Pages 403 - 404
1 May 1970
Bonnin JG


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1087 - 1087
1 Nov 1999
Klenerman L


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 154 - 154
1 Jan 2001
Johnson J


The Bone & Joint Journal
Vol. 107-B, Issue 1 | Pages 124 - 132
1 Jan 2025
Thompson P Khattak M Joseph PJ Perry DC Cootes TF Lindner C

Aims. The aims of this study were to develop an automatic system capable of calculating four radiological measurements used in the diagnosis and monitoring of cerebral palsy (CP)-related hip disease, and to demonstrate that these measurements are sufficiently accurate to be used in clinical practice. Methods. We developed a machine-learning system to automatically measure Reimer’s migration percentage (RMP), acetabular index (ACI), head shaft angle (HSA), and neck shaft angle (NSA). The system automatically locates points around the femoral head and acetabulum on pelvic radiographs, and uses these to calculate measurements. The system was evaluated on 1,650 pelvic radiographs of children with CP (682 females and 968 males, mean age 8.3 years (SD 4.5)). Each radiograph was manually measured by five clinical experts. Agreement between the manual clinical measurements and the automatic system was assessed by mean absolute deviation (MAD) from the mean manual measurement, type 1 and type 2 intraclass correlation coefficients (ICCs), and a linear mixed-effects model (LMM) for assessing bias. Results. The MAD scores were 5.7% (SD 8.5%) for RMP, 4.3° (SD 5.4°) for ACI, 5.0° (SD 5.2°) for NSA, and 5.7° (SD 6.1°) for HSA. Overall ICCs quantifying the agreement between the mean manual measurement and the automatic results were 0.91 for RMP, 0.66 for ACI, 0.85 for NSA, and 0.73 for HSA. The LMM showed no statistically significant bias. Conclusion. The results showed excellent agreement between the manual and automatic measurements for RMP, good agreement for NSA, and moderate agreement for HSA and ACI. The performance of the system is sufficient for application in clinical practice to support the assessment of hip migration based on RMP. The system has the potential to save clinicians time and to improve patient care by enabling more comprehensive, consistent, and reliable monitoring of hip migration in children with CP. Cite this article: Bone Joint J 2025;107-B(1):124–132