Advertisement for orthosearch.org.uk
Results 1 - 20 of 92
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 836 - 840
1 Aug 2003
Kooijman HJ Driessen APPM van Horn JR

We studied retrospectively the outcome of patellofemoral arthroplasty (PFA) using the Richards prosthesis in 51 patients (56 knees). Their mean age was 50 years (30 to 77). In 43 patients (45 knees), the American Knee Society score and the patients’ subjective judgement were assessed. Excellent or good results were obtained in 86% of cases at a mean follow-up of 17 years (15 to 21). Because of ongoing tibiofemoral osteoarthritis, two patients required a high tibial osteotomy and ten PFAs were converted to a total knee arthroplasty after a mean of 15.6 years (10 to 21). The PFAs were stable during follow-up with a loosening rate of only 2%. We conclude that a patellofemoral prosthesis is a good treatment option with successful long-term results in middle-aged patients with radiologically documented, isolated, patellofemoral osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 355 - 358
1 Apr 2001
Gill GS Joshi AB

We present the long-term results of the Kinematic Condylar Knee Arthroplasty followed in a prospective fashion. Between October 1982 and March 1988, 404 consecutive replacement arthroplasties were carried out on 335 patients. Of these, 354 knees had osteoarthritis, 45 rheumatoid arthritis and five other diagnoses. At the time of final follow-up 158 patients (188 knees) had died. No patient was lost to follow-up. The minimum follow-up for all living patients was ten years (10 to 17). The mean age at surgery was 68 years (30 to 92). There were seven complications (1.7%). Sixteen knees (3.9%) were revised, four because of infection. Survivorship was 99.4% (CI 97.9 to 99.8) at five years, 98.2% (CI 96.1 to 99.2) at ten years and 92.6% (CI 87.6 to 95.6) at 17 years


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 510 - 512
1 May 2001
Gill GS Joshi AB

We analysed the long-term results with a mean follow-up of 10.2 years, of 66 total knee replacements in 42 patients with rheumatoid arthritis. In all cases the posterior cruciate ligament was retained. There were only three complications (4.5%). Revision surgery was necessary in five knees (7.6%), including one (1.5%) with infection. At the final follow-up, 75.8% of knees were rated excellent clinically. Only 15% had an excellent function score. The survival rate of the implant was 90.7% at 19 years. The clinical, radiological and survivorship analysis shows that the posterior-cruciate-retaining knee arthroplasty performs well in rheumatoid arthritis


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 9 - 15
1 Oct 2015
Parratte S Ollivier M Lunebourg A Abdel MP Argenson J

Partial knee arthroplasty (PKA), either medial or lateral unicompartmental knee artroplasty (UKA) or patellofemoral arthroplasty (PFA) are a good option in suitable patients and have the advantages of reduced operative trauma, preservation of both cruciate ligaments and bone stock, and restoration of normal kinematics within the knee joint. However, questions remain concerning long-term survival. The goal of this review article was to present the long-term results of medial and lateral UKA, PFA and combined compartmental arthroplasty for multicompartmental disease. Medium- and long-term studies suggest reasonable outcomes at ten years with survival greater than 95% in UKA performed for medial osteoarthritis or osteonecrosis, and similarly for lateral UKA, particularly when fixed-bearing implants are used. Disappointing long-term outcomes have been observed with the first generation of patellofemoral implants, as well as early Bi-Uni (ie, combined medial and lateral UKA) or Bicompartmental (combined UKA and PFA) implants due to design and fixation issues. Promising short- and med-term results with the newer generations of PFAs and bicompartmental arthroplasties will require long-term confirmation.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):9–15.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 937 - 940
1 Jul 2012
Manopoulos P Havet E Pearce O Lardanchet JF Mertl P

This was a retrospective analysis of the medium- to long-term results of 46 TC3 Sigma revision total knee replacements using long uncemented stems in press-fit mode. Clinical and radiological analysis took place pre-operatively, at two years post-operatively, and at a mean follow-up of 8.5 years (4 to 12). The mean pre-operative International Knee Society (IKS) clinical score was 42 points (0 to 74), improving to 83.7 (52 to 100) by the final follow-up. The mean IKS score for function improved from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up. At the final follow-up 30 knees (65.2%) had an excellent result, seven (15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor result. There were two failures, one with anteroposterior instability and one with aseptic loosening. The TC3 revision knee system, when used with press-fit for long intramedullary stems and cemented femoral and tibial components, in both septic and aseptic revisions, results in a satisfactory clinical and radiological outcome, and has a good medium- to long-term survival rate


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 46 - 52
1 Jan 2019
León SA Mei XY Safir OA Gross AE Kuzyk PR

Aims

The aim of this study was to report the outcome of femoral condylar fresh osteochondral allografts (FOCA) with concomitant realignment osteotomy with a focus on graft survivorship, complications, reoperation, and function.

Patients and Methods

We identified 60 patients (16 women, 44 men) who underwent unipolar femoral condylar FOCA with concomitant realignment between 1972 and 2012. The mean age of the patients was 28.9 years (10 to 62) and the mean follow-up was 11.4 years (2 to 35). Failure was defined as conversion to total knee arthroplasty, revision allograft, or graft removal. Clinical outcome was evaluated using the modified Hospital for Special Surgery (mHSS) score.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1022 - 1026
1 Aug 2006
Langlais F Belot N Ropars M Lambotte JC Thomazeau H

We evaluated the long-term fixation of 64 press-fit cemented stems of constrained total knee prostheses in 32 young patients with primary malignant bone tumours. Initial stable fixation, especially in rotation, was achieved by precise fit of the stem into the reamed endosteum, before cementation. Complementary fixation, especially in migration and rotation, was obtained by pressurised antibiotic-loaded cement. The mean age at operation was 33 years (13 to 61). No patient was lost to follow-up; 13 patients died and the 19 survivors were examined at a mean follow-up of 12.5 years (4 to 21). Standard revision press-fit cemented stems were used on the side of the joint which was not involved with tumour (26 tibial and six femoral), on this side there was no loosening or osteolysis and stem survival was 100%. On the reconstruction side, custom-made press-fit stems were used and the survival rate, with any cause for revision as an end point, was 88%, but 97% for loosening or osteolysis. This longevity is similar to that achieved at 20 years with the Charnley-Kerboull primary total hip replacement with press-fit cemented femoral components.

We recommend this type of fixation when extensive reconstruction of the knee is required. It may also be suitable for older patients requiring revision of a total knee replacement or in difficult situations such as severe deformity and complex articular fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 185 - 189
1 Feb 2012
Lim H Bae J Park Y Park Y Park J Park J Suh D

The purpose of this study was to evaluate the long-term functional and radiological outcomes of arthroscopic removal of unstable osteochondral lesions with subchondral drilling in the lateral femoral condyle. We reviewed the outcome of 23 patients (28 knees) with stage III or IV osteochondritis dissecans lesions of the lateral femoral condyle at a mean follow-up of 14 years (10 to 19). The functional clinical outcomes were assessed using the Lysholm score, which improved from a mean of 38.1 (sd 3.5) pre-operatively to a mean of 87.3 (sd 5.4) at the most recent review (p = 0.034), and the Tegner activity score, which improved from a pre-operative median of 2 (0 to 3) to a median of 5 (3 to 7) at final follow-up (p = 0.021). The radiological degenerative changes were evaluated according to Tapper and Hoover’s classification and when compared with the pre-operative findings, one knee had grade 1, 22 knees had grade 2 and five knees had grade 3 degenerative changes. The overall outcomes were assessed using Hughston’s rating scale, where 19 knees were rated as good, four as fair and five as poor.

We found radiological evidence of degenerative changes in the third or fourth decade of life at a mean of 14 years after arthroscopic excision of the loose body and subchondral drilling for an unstable osteochondral lesion of the lateral femoral condyle. Clinical and functional results were more satisfactory.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1077 - 1080
1 Aug 2005
Sharma S Nicol F Hullin MG McCreath SW

We analysed the long-term clinical and radiological results of 63 uncemented Low Contact Stress total knee replacements in 47 patients with rheumatoid arthritis. At a mean follow-up of 12.9 years (10 to 16), 36 patients (49 knees) were still alive; three patients (five knees) were lost to follow-up. Revision was necessary in three knees (4.8%) and the rate of infection was 3.2%. The mean clinical and functional Knee Society scores were 90 (30 to 98) and 59 (25 to 90), respectively, at final follow-up and the mean active range of movement was 104° (55° to 120°). The survival rate was 94% at 16 years but 85.5% of patients lost to follow-up were considered as failures. Radiological evidence of impending failure was noted in one knee.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1317 - 1323
1 Oct 2007
Kim Y Yoon S Kim J

We compared the results of 146 patients who received an anatomic modular knee fixed-bearing total knee replacement (TKR) in one knee and a low contact stress rotating platform mobile-bearing TKR in the other. There were 138 women and eight men with a mean age of 69.8 years (42 to 80). The mean follow-up was 13.2 years (11.0 to 14.5). The patients were assessed clinically and radiologically using the rating systems of the Hospital for Special Surgery and the Knee Society at three months, six months, one year, and annually thereafter.

The assessment scores of both rating systems pre-operatively and at the final review did not show any statistically significant differences between the two designs of implant. In the anatomic modular knee group, one knee was revised because of aseptic loosening of the tibial component and one because of infection. In addition, three knees were revised because of wear of the polyethylene tibial bearing. In the low contact stress group, two knees were revised because of instability requiring exchange of the polyethylene insert and one because of infection.

The radiological analysis found no statistical difference in the incidence of radiolucent lines at the final review (Student’s t-test, p = 0.08), most of which occurred at tibial zone 1. The Kaplan-Meier survivorship for aseptic loosening of the anatomic modular knee and the low contact stress implants at 14.5 years was 99% and 100%, respectively, with a 95% confidence interval of 94% to 100% for both designs.

We found no evidence of the superiority of one design over the other at long-term follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 513 - 516
1 May 2001
Hoser C Fink C Brown C Reichkendler M Hackl W Bartlett J

We evaluated the outcome of partial lateral meniscectomy of 31 knees in 29 patients whose knees were otherwise normal. The mean follow-up was 10.3 years.

According to the Lysholm score, 14 knees were rated as excellent, four as good, five as fair and eight as poor, with a mean score of 80.5 points. Radiologically, only one lateral compartment was classified as grade 0, eight as grade 1, nine as grade 2, 11 as grade 3, and two as grade 4 according to Tapper and Hoover. No significant (p < 0.05) correlation was found between the amount of tissue resected and the subjective, clinical and radiological outcome.

Although early results of lateral meniscectomy may be satisfactory, we have demonstrated that in the long term there was a high incidence of degenerative changes, a high rate of reoperation (29%) and a relatively low functional outcome score.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 601 - 607
1 May 2016
McClelland D Barlow D Moores TS Wynn-Jones C Griffiths D Ogrodnik PJ Thomas PBM

In arthritis of the varus knee, a high tibial osteotomy (HTO) redistributes load from the diseased medial compartment to the unaffected lateral compartment.

We report the outcome of 36 patients (33 men and three women) with 42 varus, arthritic knees who underwent HTO and dynamic correction using a Garches external fixator until they felt that normal alignment had been restored. The mean age of the patients was 54.11 years (34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3 to 10) post-operatively. Radiographs, gait analysis and visual analogue scores for pain were measured pre- and post-operatively, at one year and at medium-term follow-up (mean six years; 2 to 10). Failure was defined as conversion to knee arthroplasty.

Pre-operative gait analysis divided the 42 knees into two equal groups with high (17 patients) or low (19 patients) adductor moments. After correction, a statistically significant (p < 0.001, t-test,) change in adductor moment was achieved and maintained in both groups, with a rate of failure of three knees (7.1%), and 89% (95% confidence interval (CI) 84.9 to 94.7) survivorship at medium-term follow-up.

At final follow-up, after a mean of 15.9 years (12 to 20), there was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of adductor moment group, with a mean time to conversion to knee arthroplasty of 9.5 years (3 to 18; 95% confidence interval ± 2.5).

HTO remains a useful option in the medium-term for the treatment of medial compartment osteoarthritis of the knee but does not last in the long-term.

Cite this article: Bone Joint J 2016;98-B:601–7.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 478 - 485
1 Apr 2013
Naveed MA Ackroyd CE Porteous AJ

We present the ten- to 15-year follow-up of 31 patients (34 knees), who underwent an Elmslie-Trillat tibial tubercle osteotomy for chronic, severe patellar instability, unresponsive to non-operative treatment. The mean age of the patients at the time of surgery was 31 years (18 to 46) and they were reviewed post-operatively, at four years (2 to 8) and then at 12 years (10 to 15). All patients had pre-operative knee radiographs and Cox and Insall knee scores. Superolateral portal arthroscopy was performed per-operatively to document chondral damage and after the osteotomy to assess the stability of the patellofemoral joint. A total of 28 knees (82%) had a varying degree of damage to the articular surface. At final follow-up 25 patients (28 knees) were available for review and underwent clinical examination, radiographs of the knee, and Cox and Insall scoring. Six patients who had no arthroscopic chondral abnormality showed no or only early signs of osteoarthritis on final radiographs; while 12 patients with lower grade chondral damage (grade 1 to 2) showed early to moderate signs of osteoarthritis and six out of ten knees with higher grade chondral damage (grade 3 to 4) showed marked evidence of osteoarthritis; four of these had undergone a knee replacement. In the 22 patients (24 knees) with complete follow-up, 19 knees (79.2%) were reported to have a good or excellent outcome at four years, while 15 knees (62.5%) were reported to have the same at long-term follow-up. The functional and radiological results show that the extent of pre-operatively sustained chondral damage is directly related to the subsequent development of patellofemoral osteoarthritis.

Cite this article: Bone Joint J 2013;95-B:478–85.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 861 - 864
1 Aug 2002
Nakagawa K Wada Y Minamide M Tsuchiya A Moriya H

We examined an39 patients (45 knees) who had undergone Elmslie-Trillat procedure for recurrent or habitual dislocation of the patella with a follow-up of more than ten years. The mean age at the time of surgery was 18.4 years; the mean follow-up was 161 months (120 to 238). Using Fulkerson’s functional knee score, 41 knees (91%) had an excellent or good result at a mean follow-up of 45 months, and this was maintained in 29 (64%) at the final review.

The main cause of deterioration in the clinical results was the onset or worsening of patellofemoral joint pain, not patellar instability.


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1025 - 1032
1 Aug 2020
Hampton M Mansoor J Getty J Sutton PM

Aims. Total knee arthroplasty is an established treatment for knee osteoarthritis with excellent long-term results, but there remains controversy about the role of uncemented prostheses. We present the long-term results of a randomized trial comparing an uncemented tantalum metal tibial component with a conventional cemented component of the same implant design. Methods. Patients under the age of 70 years with symptomatic osteoarthritis of the knee were randomized to receive either an uncemented tantalum metal tibial monoblock component or a standard cemented modular component. The mean age at time of recruitment to the study was 63 years (50 to 70), 46 (51.1%) knees were in male patients, and the mean body mass index was 30.4 kg/m. 2. (21 to 36). The same cruciate retaining total knee system was used in both groups. All patients received an uncemented femoral component and no patients had their patella resurfaced. Patient outcomes were assessed preoperatively and postoperatively using the modified Oxford Knee Score, Knee Society Score, and 12-Item Short-Form Health Survey questionnaire (SF-12) score. Radiographs were analyzed using the American Knee Society Radiograph Evaluation score. Operative complications, reoperations, or revision surgery were recorded. A total of 90 knees were randomized and at last review 77 knees were assessed. In all, 11 patients had died and two were lost to follow-up. Results. At final review all patients were between 11 and 15 years following surgery. In total, 41 of the knees were cemented and 36 uncemented. There were no revisions in the cemented group and one revision in the uncemented group for fracture. The uncemented group reported better outcomes with both statistically and clinically significant (p = 0.001) improvements in knee-specific Oxford and Knee Society scores compared with the cemented group. The global SF-12 scores demonstrated no statistical difference (p = 0.812). Uncemented knees had better radiological analysis compared with the cemented group (p < 0.001). Conclusion. Use of an uncemented trabecular metal tibial implant can afford better long-term clinical outcomes when compared to cemented tibial components of a matched design. However, both have excellent survivorship up to 15 years after implantation. Cite this article: Bone Joint J 2020;102-B(8):1025–1032


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1033 - 1040
1 Aug 2020
Kennedy JA Mohammad HR Yang I Mellon SJ Dodd CAF Pandit HG Murray DW

Aims. To report mid- to long-term results of Oxford mobile bearing domed lateral unicompartmental knee arthroplasty (UKA), and determine the effect of potential contraindications on outcome. Methods. A total of 325 consecutive domed lateral UKAs undertaken for the recommended indications were included, and their functional and survival outcomes were assessed. The effects of age, weight, activity, and the presence of full-thickness erosions of cartilage in the patellofemoral joint on outcome were evaluated. Results. Median follow-up was seven years (3 to 14), and mean age at surgery was 65 years (39 to 90). Median Oxford Knee Score (OKS) was 43 (interquartile range (IQR) 37 to 47), with 260 (80%) achieving a good or excellent score (OKS > 34). Revisions occurred in 34 (10%); 14 (4%) were for dislocation, of which 12 had no recurrence following insertion of a new bearing, and 12 (4%) were revised for medial osteoarthritis (OA). Ten-year survival was 85% (95% confidence interval (CI) 79 to 90, at risk 72). Age, weight, activity, and patellofemoral erosions did not have a significant effect on the clinical outcome or survival. Conclusion. Domed lateral UKA provides a good alternative to total knee arthroplasty (TKA) in the management of lateral compartment OA. Although dislocation is relatively easy to treat successfully, the dislocation rate of 4% is high. It is recommended that the stability of the bearing is assessed intraoperatively. If the bearing can easily be displaced, the fixed rather than the mobile bearing version of the Oxford lateral tibial component should be inserted instead. Younger age, heavier weight, high activity, and patellofemoral erosions did not detrimentally affect outcome, so should not be considered contraindications. Cite this article: Bone Joint J 2020;102-B(8):1033–1040


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1162 - 1167
1 Sep 2018
Metcalfe AJ Ahearn N Hassaballa MA Parsons N Ackroyd CE Murray JR Robinson JR Eldridge JD Porteous AJ

Aims. This study reports on the medium- to long-term implant survivorship and patient-reported outcomes for the Avon patellofemoral joint (PFJ) arthroplasty. Patients and Methods. A total of 558 Avon PFJ arthroplasties in 431 patients, with minimum two-year follow-up, were identified from a prospective database. Patient-reported outcomes and implant survivorship were analyzed, with follow-up of up to 18 years. Results. Outcomes were recorded for 483 implants (368 patients), representing an 86% follow-up rate. The median postoperative Oxford Knee Score (0 to 48 scale) was 35 (interquartile range (IQR) 25.5 to 43) and the median Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC, 0 to 100 scale) was 35 (IQR 25 to 53) at two years. There were 105 revisions, 61 (58%) for progression of osteoarthritis. All documented revisions were to primary knee systems without augmentation. The implant survival rate was 77.3% (95% confidence interval (CI) 72.4 to 81.7, number at risk 204) at ten years and 67.4% (95% CI 72.4 to 81.7 number at risk 45) at 15 years. Regression analysis of explanatory data variable showed that cases performed in the last nine years had improved survival compared with the first nine years of the cohort, but the individual operating surgeon had the strongest effect on survivorship. Conclusion. Satisfactory long-term results can be obtained with the Avon PFJ arthroplasty, with maintenance of patient-reported outcome measures (PROMs), satisfactory survival, and low rates of loosening and wear. Cite this article: Bone Joint J 2018;100-B:1162–7


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 855 - 863
1 May 2021
Koster LA Meinardi JE Kaptein BL Van der Linden - Van der Zwaag E Nelissen RGHH

Aims

The objective of this study was to compare the two-year migration pattern and clinical outcomes of a total knee arthroplasty (TKA) with an asymmetrical tibial design (Persona PS) and a well-proven TKA with a symmetrical tibial design (NexGen LPS).

Methods

A randomized controlled radiostereometric analysis (RSA) trial was conducted including 75 cemented posterior-stabilized TKAs. Implant migration was measured with RSA. Maximum total point motion (MTPM), translations, rotations, clinical outcomes, and patient-reported outcome measures (PROMs) were assessed at one week postoperatively and at three, six, 12, and 24 months postoperatively.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1050 - 1055
1 Aug 2016
Karachalios T Varitimidis S Bargiotas K Hantes M Roidis N Malizos KN

Aims. The Advance Medial-Pivot total knee arthroplasty (TKA) was designed to reflect contemporary data regarding the kinematics of the knee. We wished to examine the long-term results obtained with this prosthesis by extending a previous evaluation. Patients and Methods. We retrospectively evaluated prospectively collected data from 225 consecutive patients (41 men and 184 women; mean age at surgery 71 years, 52 to 84) who underwent 284 TKAs with a mean follow-up of 13.4 years (11 to 15). Implant failure, complication rate, clinical (both subjective and objective) and radiological outcome were assessed. Pre- and post-operative clinical and radiographic data were available at regular intervals for all patients. A total of ten patients (4.4%; ten TKAs) were lost to follow-up. Results. Survival analysis at 15 years showed a cumulative success rate of 97.3% (95% confidence interval (CI) 96.7 to 97.9) for revision for any reason, of 96.4% (95% CI 95.2 to 97.6) for all operations, and 98.8% (95% CI 98.2 to 99.4) for aseptic loosening as an end point. Three TKAs (1.06%) were revised due to aseptic loosening, two (0.7%) due to infection, one (0.35%) due to instability and one (0.35%) due to a traumatic dislocation. All patients showed a statistically significant improvement on the Knee Society Score (p = 0.001), Western Ontario and McMaster University Osteoarthritis Index (p = 0.001), Short Form-12 (p = 0.01), and Oxford Knee Score (p = 0.01). A total of 207 patients (92%) were able to perform age appropriate activities with a mean flexion of the knee of 117° (85° to 135°) at final follow-up. Conclusion. This study demonstrates satisfactory functional and radiographic long-term results for this implant. Cite this article: Bone Joint J 2016;98-B:1050–5


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 840 - 845
1 May 2021
Rossi SMP Perticarini L Clocchiatti S Ghiara M Benazzo F

Aims

In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up.

Methods

A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis.