Advertisement for orthosearch.org.uk
Results 1 - 20 of 292
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1225 - 1233
1 Nov 2022
Png ME Petrou S Achten J Ooms A Lamb SE Hedley H Dias J Costa ML

Aims. The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. Methods. An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves. Results. In the base case analysis, surgical fixation with K-wire was more expensive (£29.65 (95% confidence interval (CI) -94.85 to 154.15)) and generated lower QALYs (0.007 (95% CI -0.03 to 0.016)) than moulded casting, but this difference was not statistically significant. The probability of K-wire being cost-effective at a £20,000 per QALY cost-effectiveness threshold was 24%. The cost-effectiveness results remained robust in the sensitivity analyses. Conclusion. The findings suggest that surgical fixation with K-wire is unlikely to be a cost-effective alternative to a moulded cast in adults, following manipulation of a fracture of the distal radius in a theatre setting. Cite this article: Bone Joint J 2022;104-B(11):1225–1233


Aims. The aim of this study was to compare the clinical effectiveness of Kirschner wire (K-wire) fixation with locking-plate fixation for patients with a dorsally displaced fracture of the distal radius in the five years after injury. Patients and Methods. We report the five-year follow-up of a multicentre, two-arm, parallel-group randomized controlled trial. A total of 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation were recruited from 18 trauma centres in the United Kingdom. Patients were excluded if the surface of the wrist joint was so badly displaced it required open reduction. In all, 448 patients were randomized to receive either K-wire fixation or locking-plate fixation. In the K-wire group, there were 179 female and 38 male patients with a mean age of 59.1 years (19 to 89). In the locking-plate group, there were 194 female and 37 male patients with a mean age of 58.3 years (20 to 89). The primary outcome measure was the patient-rated wrist evaluation (PRWE). Secondary outcomes were health-related quality of life using the EuroQol five-dimension three-level (EQ-5D-3L) assessment, and further surgery related to the index fracture. Results. At 12 months, 402/448 participants (90%) recruited into the main study provided PRWE scores. At year two, 294 participants (66%) provided scores; at year five, 198 participants (44%) provided scores. There was no clinically relevant difference in the PRWE at any point during the five-year follow-up; at five years, the PRWE score was 8.3 (12.5) in the wire group and 11.3 (15.6) in the plate group (95% confidence interval -6.99 to 0.99; p = 0.139). Nor was there a clinically relevant difference in health-related quality of life. Only three participants had further surgery in the five years after their injury (one in the wire group and two in the plate group). Conclusion. This follow-up study continues to show no evidence of a difference in wrist pain, wrist function, or quality of life for patients treated with wires versus locking plates in the five years following a dorsally displaced fracture of the distal radius. Cite this article: Bone Joint J 2019;101-B:978–983


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1263 - 1271
1 Oct 2019
Eisenschenk A Spitzmüller R Güthoff C Obladen A Kim S Henning E Dornberger JE Stengel D

Aims. The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires. Patients and Methods. This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications. Results. Overall, 151/290 of patients (52%) completed the six months of follow-up, leaving 83 patients in the single-wire group and 68 patients in the dual-wire group. In the modified intention-to-treat analysis set, mean DASH scores six months after surgery were 3.8 (. sd. 7.0) and 4.4 (. sd. 9.4), respectively. With multiple imputation (n = 288), mean DASH scores were estimated at 6.3 (. sd. 8.7) and 7.0 (. sd. 10.0). Upper (1 - 2α)) confidence limits consistently remained below the noninferiority margin of 3.0 points in the DASH instrument. While there was a statistically nonsignificant trend towards a higher rate of shortening and rotational malalignment in the single wire group, no statistically significant differences were observed across groups in any secondary outcome measure. Conclusion. A single thick K-wire is sufficient for intramedullary fixation of acute displaced subcapital fractures of the fifth metacarpal neck. The less technically demanding single-wire technique produces noninferior clinical and radiological outcomes compared with the dual-wire approach. Cite this article: Bone Joint J 2019;101-B:1263–1271


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1082 - 1089
1 Aug 2015
Tubeuf S Yu G Achten J Parsons NR Rangan A Lamb SE Costa ML

We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with dorsally-displaced fractures of the distal radius. . The cost effectiveness analysis (cost per quality-adjusted life year; QALY) was derived from a multi-centre, two-arm, parallel group, assessor-blind, randomised controlled trial which took place in 18 trauma centres in the United Kingdom. Data from 460 patients were available for analysis, which includes both a National Health Service cost perspective including costs of surgery, implants and healthcare resource use over a 12-month period after surgery, and a societal perspective, which includes the cost of time off work and the need for additional private care. . There was only a small difference in QALYs gained for patients treated with locking-plate fixation over those treated with K-wires. At a mean additional cost of £714 (95% confidence interval 588 to 865) per patient, locking-plate fixation presented an incremental cost effectiveness ratio (ICER) of £89 322 per QALY within the first 12 months of treatment. Sensitivity analyses were undertaken to assess the ICER of locking-plate fixation compared with K-wires. These were greater than £30 000. . Compared with locking-plate fixation, K-wire fixation is a ‘cost saving’ intervention, with similar health benefits. Cite this article: Bone Joint J 2015;97-B:1082–9


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 106 - 108
1 Jan 1998
Ngarmukos C Parkpian V Patradul A

We treated 110 fractures of the middle third of the clavicle in 108 patients aged between 14 and 66 years, by fixation with 2 mm Kirschner wires. The wire was introduced, using an air drill and a telescoping guide, from the medial into the lateral fragment. The medial end of the wire which perforated the anterior cortex of the medial fragment was bent backwards to prevent migration into the lung or mediastinum. In cases of nonunion and acute fracture in which a bone gap was present, bone graft was laid around the fracture site after internal fixation. All the fractures united. No wires broke but in three patients one migrated before union was achieved. Twenty-one patients failed to return for removal of the wire; nine of them had radiological evidence of union before they were lost to follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 858 - 861
1 Nov 1992
Casteleyn P Handelberg F Haentjens P

In a prospective trial, biodegradable polyglycolic acid rods were compared with Kirschner wires for fixation of wrist fractures (Frykman types I, II, V and VI). Fifteen patients were randomly assigned to each treatment group. There was no significant difference between the groups with regard to age, sex ratio and fracture type. Kapandji's pinning technique was used in all cases. There were no significant differences in the results obtained in both groups at final follow-up. At three months and six months the functional results of the Kirschner-wire group were, however, significantly better (p < 0.05), due to numerous transient complications from foreign-body reactions to the polyglycolic acid rods. The use of polyglycolic acid rods is therefore not recommended for the fixation of distal radial fractures


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 809 - 814
1 Jun 2013
Park HY Yoon JO Jeon IH Chung HW Kim JS

This study was performed to determine whether pure cancellous bone graft and Kirschner (K-) wire fixation were sufficient to achieve bony union and restore alignment in scaphoid nonunion. A total of 65 patients who underwent cancellous bone graft and K-wire fixation were included in this study. The series included 61 men and four women with a mean age of 34 years (15 to 72) and mean delay to surgery of 28.7 months (3 to 240). The patients were divided into an unstable group (A) and stable group (B) depending on the pre-operative radiographs. Unstable nonunion was defined as a lateral intrascaphoid angle > 45°, or a radiolunate angle > 10°. There were 34 cases in group A and 31 cases in group B. Bony union was achieved in 30 patients (88.2%) in group A, and in 26 (83.9%) in group B (p = 0.439). Comparison of the post-operative radiographs between the two groups showed no significant differences in lateral intrascaphoid angle (p = 0.657) and scaphoid length (p = 0.670) and height (p = 0.193). The radiolunate angle was significantly different (p = 0.020) but the mean value in both groups was < 10°. Comparison of the dorsiflexion and palmar flexion of movement of the wrist and the mean Mayo wrist score at the final clinical visit in each group showed no significant difference (p = 0.190, p = 0.587 and p = 0.265, respectively). Cancellous bone graft and K-wire fixation were effective in the treatment of stable and unstable scaphoid nonunion. Cite this article: Bone Joint J 2013;95-B:809–14


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 292 - 296
1 Mar 1992
Plaga B Royster R Donigian A Wright G Caskey P

We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 902 - 907
1 May 2021
Marson BA Ng JWG Craxford S Chell J Lawniczak D Price KR Ollivere BJ Hunter JB

Aims

The management of completely displaced fractures of the distal radius in children remains controversial. This study evaluates the outcomes of surgical and non-surgical management of ‘off-ended’ fractures in children with at least two years of potential growth remaining.

Methods

A total of 34 boys and 22 girls aged 0 to ten years with a closed, completely displaced metaphyseal distal radial fracture presented between 1 November 2015 and 1 January 2020. After 2018, children aged ten or under were offered treatment in a straight plaster or manipulation under anaesthesia with Kirschner (K-)wire stabilization. Case notes and radiographs were reviewed to evaluate outcomes. In all, 16 underwent treatment in a straight cast and 40 had manipulation under anaesthesia, including 37 stabilized with K-wires.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1478 - 1481
1 Nov 2009
Lee YH Kim JY Chung MS Baek GH Gong HS Lee SK

We treated 32 displaced mallet finger fractures by a two extension block Kirschner-wire technique. The clinical and radiological outcomes were evaluated at a mean follow-up of 49 months (25 to 84). The mean joint surface involvement was 38.4% (33% to 50%) and 18 patients (56%) had accompanying joint subluxation.

All 32 fractures united with a mean time to union of 6.2 weeks (5.1 to 8.2). Congruent joint surfaces and anatomical reduction were seen in all cases. The mean flexion of the distal interphalangeal joints was 83.1° (75° to 90°) and the mean extension loss was 0.9° (0° to 7°). No digit had a prominent dorsal bump or a recurrent mallet deformity.

We believe that this technique, when properly applied, produces satisfactory results both clinically and radiologically.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 746 - 746
1 Jul 1998
HOPKINSON-WOOLLEY JA CONSTANT CR


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 326 - 327
1 Mar 1988
Potter F Fiorini A Knox J Rajesh P


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 82 - 87
1 Jan 2023
Barrie A Kent B

Aims. Management of displaced paediatric supracondylar elbow fractures remains widely debated and actual practice is unclear. This national trainee collaboration aimed to evaluate surgical and postoperative management of these injuries across the UK. Methods. This study was led by the South West Orthopaedic Research Division (SWORD) and performed by the Supra Man Collaborative. Displaced paediatric supracondylar elbow fractures undergoing surgery between 1 January 2019 and 31 December 2019 were retrospectively identified and their anonymized data were collected via Research Electronic Data Capture (REDCap). Results. A total of 972 patients were identified across 41 hospitals. Mean age at injury was 6.3 years (1 to 15), 504 were male (52%), 583 involved the left side (60%), and 538 were Gartland type 3 fractures (55%). Median time from injury to theatre was 16 hours (interquartile range (IQR) 6.6 to 22), 300 patients (31%) underwent surgery on the day of injury, and 91 (9%) underwent surgery between 10:00 pm and 8:00 am. Overall, 910 patients (94%) had Kirschner (K)-wire) fixation and these were left percutaneous in 869 (95%), while 62 patients (6%) had manipulation under anaesthetic (MUA) and casting. Crossed K-wire configuration was used as fixation in 544 cases (59.5%). Overall, 208 of the fixation cases (61%) performed or supervised by a paediatric orthopaedic consultant underwent lateral-only fixation, whereas 153 (27%) of the fixation cases performed or supervised by a non-paediatric orthopaedic consultant used lateral-only fixation. In total, 129 percutaneous wires (16%) were removed in theatre. Of the 341 percutaneous wire fixations performed or supervised by a paediatric orthopaedic consultant, 11 (3%) underwent wire removal in theatre, whereas 118 (22%) of the 528 percutaneous wire fixation cases performed or supervised by a non-paediatric orthopaedic consultant underwent wire removal in theatre. Four MUA patients (6%) and seven K-wire fixation patients (0.8%) required revision surgery within 30 days for displacement. Conclusion. The treatment of supracondylar elbow fractures in children varies across the UK. Patient cases where a paediatric orthopaedic consultant was involved had an increased tendency for lateral only K-wire fixation and for wire removal in clinic. Low rates of displacement requiring revision surgery were identified in all fixation configurations. Cite this article: Bone Joint J 2023;105-B(1):82–87


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 946 - 952
1 Aug 2022
Wu F Zhang Y Liu B

Aims. This study aims to report the outcomes in the treatment of unstable proximal third scaphoid nonunions with arthroscopic curettage, non-vascularized bone grafting, and percutaneous fixation. Methods. This was a retrospective analysis of 20 patients. All cases were delayed presentations (n = 15) or failed nonoperatively managed scaphoid fractures (n = 5). Surgery was performed at a mean duration of 27 months (7 to 120) following injury with arthroscopic debridement and arthroscopic iliac crest autograft. Fracture fixation was performed percutaneously with Kirschner (K)-wires in 12 wrists, a headless screw in six, and a combination of a headless screw and single K-wire in two. Clinical outcomes were assessed using grip strength, patient-reported outcome measures, and wrist range of motion (ROM) measurements. Results. Intraoperatively, established avascular necrosis of the proximal fragment was identified in ten scaphoids. All fractures united within 16 weeks, confirmed by CT. At a mean follow-up of 31 months (12 to 64), there were significant improvements in the Patient-Rated Wrist Evaluation, Mayo Wrist Score, abbreviated Disabilities of the Arm, Shoulder and Hand score, wrist ROM, grip strength, and the patients’ subjective pain score. No peri- or postoperative complications were encountered. Conclusion. Our data indicate that arthroscopic bone grafting and fixation with cancellous autograft is a viable method in the treatment of proximal third scaphoid nonunions, regardless of the vascularity of the proximal fragment. Cite this article: Bone Joint J 2022;104-B(8):946–952


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1550 - 1556
1 Dec 2019
Mc Colgan R Dalton DM Cassar-Gheiti AJ Fox CM O’Sullivan ME

Aims. The aim of this study was to examine trends in the management of fractures of the distal radius in Ireland over a ten-year period, and to determine if there were any changes in response to the English Distal Radius Acute Fracture Fixation Trial (DRAFFT). Patients and Methods. Data was grouped into annual intervals from 2008 to 2017. All adult inpatient episodes that involved emergency surgery for fractures of the distal radius were included. Results. In 2008 Kirschner-wire (K-wire) fixation accounted for 59% of operations for fractures of the distal radius, and plate fixation for 21%. In 2017, the rate of K-wire fixation had fallen to 30%, and the proportion of patients who underwent plate fixation had risen to 62%. Conclusion. There is an increasing trend towards open reduction and internal fixation for fractures of the distal radius in Ireland. This has been accompanied by a decrease in popularity for K-wire fixation. DRAFFT did not appear to influence trends in the management of fractures of the distal radius in Ireland. Cite this article: Bone Joint J 2019;101-B:1550–1556


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 387 - 395
1 Mar 2018
Ganeshalingam R Donnan A Evans O Hoq M Camp M Donnan L

Aims. Displaced fractures of the lateral condyle of the humerus are frequently managed surgically with the aim of avoiding nonunion, malunion, disturbances of growth and later arthritis. The ideal method of fixation is however not known, and treatment varies between surgeons and hospitals. The aim of this study was to compare the outcome of two well-established forms of surgical treatment, Kirschner wire (K-wire) and screw fixation. Patients and Methods. A retrospective cohort study of children who underwent surgical treatment for a fracture of the lateral condyle of the humerus between January 2005 and December 2014 at two centres was undertaken. Pre, intraoperative and postoperative characteristics were evaluated. A total of 336 children were included in the study. Their mean age at the time of injury was 5.8 years (0 to 15) with a male:female patient ratio of 3:2. A total of 243 (72%) had a Milch II fracture and the fracture was displaced by > 2 mm in 228 (68%). In all, 235 patients underwent K-wire fixation and 101 had screw fixation. . Results. There was a higher rate of nonunion with K-wire fixation (p = 0.02). There was no difference in Baumann’s angle, carrying angle or the rate of major complications between the two groups. No benefit was obtained by immobilizing the elbow for more than four weeks in either group. No short-term complications were seen when fixation crossed the lateral ossific nucleus. Conclusions. Fixation of lateral condylar humeral fractures in children using either K-wires or screws gives satisfactory results. Proponents of both techniques may find justification of their methods in our data, but prospective, randomized trials with long-term follow-up are required to confirm the findings, which suggest a higher rate of nonunion with K-wire fixation. Cite this article: Bone Joint J 2018;100-B:387–95


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 939 - 945
1 May 2021
Kakar S Logli AL Ramazanian T Gaston RG Fowler JR

Aims. The purpose was to evaluate early clinical, patient-reported, and radiological outcomes of the scapholunate ligament 360° tenodesis (SL 360) technique for treatment of scapholunate (SL) instability. Methods. We studied the results of nine patients (eight males and one female with a mean age of 44.7 years (26 to 55)) who underwent the SL 360 procedure for reducible SL instability between January 2016 and June 2019, and who were identified from retrospective review of electronic medical records. Final follow-up of any kind was a mean of 33.7 months (12.0 to 51.3). Clinical, radiological, and patient-reported outcome data included visual analogue scale (VAS) for pain, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), Mayo Wrist Score (MWS), and Patient-Rated Wrist Examination (PRWE). Means were analyzed using paired t-test. Results. Before surgery, patients with SL instability were significantly impaired with respect to wrist flexion, extension, and grip strength (mean flexion, 51° (20° to 85°) vs 73° (45° to 90°); mean extension, 46° (15° to 70°) vs 66° (45° to 80°); mean grip strength, 25 kg (20 to 31) vs 50 kg (35 to 68) compared to the unaffected side). The mean SL gap (4.9 mm (2.3 to 7.3) vs 2.1 mm (1.6 to 2.9)) and mean SL angle (71° (59° to 105°) vs 50° (38° to 64°) were also significantly greater in the affected wrist. At final follow-up, there was mean improvement regarding clinical, radiological, and functional outcomes comparing preoperative to final postoperative values for the VAS for pain scale, QuickDASH, MWS, PRWE, and SL gap and SL angle. Conclusion. In our small series, the SL 360 procedure for reducible SL instability has favourable early clinical, patient-reported, and radiological outcomes at a mean of 33.7 months (12.0 to 51.3). The suture tape and tendon construct confers robust stability, permitting earlier mobilization without the inherent disadvantages of Kirschner wire stabilization. Cite this article: Bone Joint J 2021;103-B(5):939–945


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1160 - 1167
1 Sep 2019
Wang WT Li YQ Guo YM Li M Mei HB Shao JF Xiong Z Li J Canavese F Chen SY

Aims. The aim of this study was to clarify the factors that predict the development of avascular necrosis (AVN) of the femoral head in children with a fracture of the femoral neck. Patients and Methods. We retrospectively reviewed 239 children with a mean age of 10.0 years (. sd. 3.9) who underwent surgical treatment for a femoral neck fracture. Risk factors were recorded, including age, sex, laterality, mechanism of injury, initial displacement, the type of fracture, the time to reduction, and the method and quality of reduction. AVN of the femoral head was assessed on radiographs. Logistic regression analysis was used to evaluate the independent risk factors for AVN. Chi-squared tests and Student’s t-tests were used for subgroup analyses to determine the risk factors for AVN. Results. We found that age (p = 0.006) and initial displacement (p = 0.001) were significant independent risk factors. Receiver operating characteristic (ROC) curve analysis indicated that 12 years of age was the cut-off for increasing the rate of AVN. Severe initial displacement (p = 0.021) and poor quality of reduction (p = 0.022) significantly increased the rate of AVN in patients aged 12 years or greater, while in those aged less than 12 years, the rate of AVN significantly increased only with initial displacement (p = 0.048). A poor reduction significantly increased the rate of AVN in patients treated by closed reduction (p = 0.026); screw and plate fixation was preferable to cannulated screw or Kirschner wire (K-wire) fixation for decreasing the rate of AVN in patients treated by open reduction (p = 0.034). Conclusion. The rate of AVN increases with age, especially in patients aged 12 years or greater, and with the severity of displacement. In patients treated by closed reduction, anatomical reduction helps to decrease the rate of AVN, while in those treated by open reduction, screw and plate fixation was preferable to fixation using cannulated screws or K-wires. Cite this article: Bone Joint J 2019;101-B:1160–1167


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 410 - 413
1 Mar 2016
Costa ML Jameson SS Reed MR

Aims. Our aim, using English Hospital Episode Statistics data before during and after the Distal Radius Acute Fracture Fixation Trial (DRAFFT), was to assess whether the results of the trial affected clinical practice. Patients and Methods. Data were grouped into six month intervals from July 2005 to December 2014. All patient episodes in the National Health Service involving emergency surgery for an isolated distal radial fracture were included. Results. Clinical practice in England had not changed in the five years before DRAFFT: 75% of patients were treated with plate fixation versus 12% with Kirschner (K)-wires. After the publication of the trial, the proportion of patients having K-wire fixation rose to 42% with a concurrent fall in the proportion having fixation with a plate to 48%. The proportion of ‘other’ procedures stayed the same. Take home message. It appears that surgeons in the United Kingdom do change their practice in response to large, pragmatic, multicentre clinical trials in musculoskeletal trauma. Cite this article: Bone Joint J 2016;98-B:410–13


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 413 - 417
1 Apr 2002
McLauchlan GJ Cowan B Annan IH Robb JE

In a prospective, randomised controlled trial, 68 children who had a completely displaced metaphyseal fracture of the distal radius were treated either by manipulation (MUA) and application of an above-elbow cast alone or by the additional insertion of a percutaneous Kirschner (K-) wire. Full radiological follow-up to union was obtained in 65 children and 56 returned for clinical evaluation three months after injury. Maintenance of reduction was significantly better in the K-wire group and fewer follow-up radiographs were required. There was no significant difference in the clinical outcome measured three months after injury. Seven of 33 patients in the MUA group had to undergo a second procedure because of an unacceptable position compared with none of the 35 in the K-wire group (chi-squared test, p < 0.01). One patient in the K-wire group required exploration for recovery of a migrated wire. We conclude that the use of a percutaneous K-wire to augment the reduction of the fracture in children who have a completely displaced metaphyseal fracture of the distal radius is a safe and reliable way of maintaining alignment of the fracture