Advertisement for orthosearch.org.uk
Results 1 - 20 of 709
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1438 - 1446
1 Nov 2019
Kong X Chai W Chen J Yan C Shi L Wang Y

Aims. This study aimed to explore whether intraoperative nerve monitoring can identify risk factors and reduce the incidence of nerve injury in patients with high-riding developmental dysplasia. Patients and Methods. We conducted a historical controlled study of patients with unilateral Crowe IV developmental dysplasia of the hip (DDH). Between October 2016 and October 2017, intraoperative nerve monitoring of the femoral and sciatic nerves was applied in total hip arthroplasty (THA). A neuromonitoring technician was employed to monitor nerve function and inform the surgeon of ongoing changes in a timely manner. Patients who did not have intraoperative nerve monitoring between September 2015 and October 2016 were selected as the control group. All the surgeries were performed by one surgeon. Demographics and clinical data were analyzed. A total of 35 patients in the monitoring group (ten male, 25 female; mean age 37.1 years (20 to 46)) and 56 patients in the control group (13 male, 43 female; mean age 37.9 years (23 to 52)) were enrolled. The mean follow-up of all patients was 13.1 months (10 to 15). Results. The two groups had no significant differences in preoperative data. In the monitoring group, ten nerve alerts occurred intraoperatively, and no neural complications were detected postoperatively. In the control group, six patients had neural complications. The rate of nerve injury was lower in the monitoring group than in the control group, but this did not achieve statistical significance. The degree of leg lengthening was significantly greater in the monitoring group than in the control group. In further analyses, patients who had previous hip surgery were more likely to have intraoperative nerve alerts and postoperative nerve injury. Conclusion. Nerve injury usually occurred during the processes of exposure and reduction. The use of intraoperative nerve monitoring showed a trend towards reduced nerve injury in THA for Crowe IV DDH patients. Hence, we recommend its routine use in patients undergoing leg lengthening, especially in those with previous hip surgery. Cite this article: Bone Joint J 2019;101-B:1438–1446


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1038 - 1044
1 Oct 2023
Walton TJ Huntley D Whitehouse SL Davies J Wilson MJ Hubble MJW Howell JR Kassam AM

Aims. The aim of this study was to perform a systematic review of the evidence for the use of intraoperative cell salvage in patients undergoing revision hip arthroplasty, and specifically to analyze the available data in order to quantify any associated reduction in the use of allogenic blood transfusion, and the volume which is used. Methods. An electronic search of MEDLINE (PubMed), Embase, Scopus, and the Cochrane Library was completed from the date of their inception to 24 February 2022, using a search strategy and protocol created in conjunction with the PRISMA statement. Inclusion criteria were patients aged > 18 years who underwent revision hip arthroplasty when cell salvage was used. Studies in which pre-donated red blood cells were used were excluded. A meta-analysis was also performed using a random effects model with significance set at p = 0.05. Results. Of the 283 studies which were identified, 11 were included in the systematic review, and nine in the meta-analysis. There was a significant difference (p < 0.001) in the proportion of patients requiring allogenic transfusion between groups, with an odds ratio of 0.331 (95% confidence interval (CI) 0.165 to 0.663) associated with the use of cell salvage. For a total of 561 patients undergoing revision hip arthroplasty who were treated with cell salvage, 247 (44.0%) required allogenic transfusion compared with 418 of 643 patients (65.0%) who were treated without cell salvage. For those treated with cell salvage, the mean volume of allogenic blood which was required was 1.95 units (390 ml) per patient (0.7 to 4.5 units), compared with 3.25 units (650 ml) per patient (1.2 to 7.0 units) in those treated without cell salvage. The mean difference of -1.91 units (95% CI -4.0 to 0.2) in the meta-analysis was also significant (p = 0.003). Conclusion. We found a a significant reduction in the need for allogenic blood transfusion when cell salvage was used in patients undergoing revision hip arthroplasty, supporting its routine use in these patients. Further research is required to determine whether this effect is associated with types of revision arthroplasty of differing complexity. Cite this article: Bone Joint J 2023;105-B(10):1038–1044


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 118 - 124
1 May 2024
Macheras GA Argyrou C Tzefronis D Milaras C Tsivelekas K Tsiamtsouris KG Kateros K Papadakis SA

Aims. Accurate diagnosis of chronic periprosthetic joint infection (PJI) presents a significant challenge for hip surgeons. Preoperative diagnosis is not always easy to establish, making the intraoperative decision-making process crucial in deciding between one- and two-stage revision total hip arthroplasty (THA). Calprotectin is a promising point-of-care novel biomarker that has displayed high accuracy in detecting PJI. We aimed to evaluate the utility of intraoperative calprotectin lateral flow immunoassay (LFI) in THA patients with suspected chronic PJI. Methods. The study included 48 THAs in 48 patients with a clinical suspicion of PJI, but who did not meet European Bone and Joint Infection Society (EBJIS) PJI criteria preoperatively, out of 105 patients undergoing revision THA at our institution for possible PJI between November 2020 and December 2022. Intraoperatively, synovial fluid calprotectin was measured with LFI. Cases with calprotectin levels ≥ 50 mg/l were considered infected and treated with two-stage revision THA; in negative cases, one-stage revision was performed. At least five tissue cultures were obtained; the implants removed were sent for sonication. Results. Calprotectin was positive (≥ 50 mg/l) in 27 cases; out of these, 25 had positive tissue cultures and/or sonication. Calprotectin was negative in 21 cases. There was one false negative case, which had positive tissue cultures. Calprotectin showed an area under the curve of 0.917, sensitivity of 96.2%, specificity of 90.9%, positive predictive value of 92.6%, negative predictive value of 95.2%, positive likelihood ratio of 10.6, and negative likelihood ratio of 0.04. Overall, 45/48 patients were correctly diagnosed and treated by our algorithm, which included intraoperative calprotectin measurement. This yielded a 93.8% concordance with postoperatively assessed EBJIS criteria. Conclusion. Calprotectin can be a valuable tool in facilitating the intraoperative decision-making process for cases in which chronic PJI is suspected and diagnosis cannot be established preoperatively. Cite this article: Bone Joint J 2024;106-B(5 Supple B):118–124


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 604 - 612
1 May 2022
MacDessi SJ Wood JA Diwan A Harris IA

Aims. Intraoperative pressure sensors allow surgeons to quantify soft-tissue balance during total knee arthroplasty (TKA). The aim of this study was to determine whether using sensors to achieve soft-tissue balance was more effective than manual balancing in improving outcomes in TKA. Methods. A multicentre randomized trial compared the outcomes of sensor balancing (SB) with manual balancing (MB) in 250 patients (285 TKAs). The primary outcome measure was the mean difference in the four Knee injury and Osteoarthritis Outcome Score subscales (ΔKOOS. 4. ) in the two groups, comparing the preoperative and two-year scores. Secondary outcomes included intraoperative balance data, additional patient-reported outcome measures (PROMs), and functional measures. Results. There was no significant difference in ΔKOOS. 4. between the two groups at two years (mean difference 0.4 points (95% confidence interval (CI) -4.6 to 5.4); p = 0.869), and multiple regression found that SB was not associated with a significant ΔKOOS. 4. (0.2-point increase (95% CI -5.1 to 4.6); p = 0.924). There were no significant differences between groups in other PROMs. Six-minute walking distance was significantly increased in the SB group (mean difference 29 metres; p = 0.015). Four-times as many TKAs were unbalanced in the MB group (36.8% MB vs 9.4% SB; p < 0.001). Irrespective of group assignment, no differences were found in any PROM when increasing ICPD thresholds defined balance. Conclusion. Despite improved quantitative soft-tissue balance, the use of sensors intraoperatively did not differentially improve the clinical or functional outcomes two years after TKA. These results question whether a more precisely balanced TKA that is guided by sensor data, and often achieved by more balancing interventions, will ultimately have a significant effect on clinical outcomes. Cite this article: Bone Joint J 2022;104-B(5):604–612


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 193 - 199
1 Feb 2022
Wang Q Wang H A G Xiao T Kang P

Aims. This study aimed to use intraoperative free electromyography to examine how the placement of a retractor at different positions along the anterior acetabular wall may affect the femoral nerve during total hip arthroplasty (THA) when undertaken using the direct anterior approach (THA-DAA). Methods. Intraoperative free electromyography was performed during primary THA-DAA in 82 patients (94 hips). The highest position of the anterior acetabular wall was defined as the “12 o’clock” position (middle position) when the patient was in supine position. After exposure of the acetabulum, a retractor was sequentially placed at the ten, 11, 12, one, and two o’clock positions (right hip; from superior to inferior positions). Action potentials in the femoral nerve were monitored with each placement, and the incidence of positive reactions (defined as explosive, frequent, or continuous action potentials, indicating that the nerve was being compressed) were recorded as the primary outcome. Secondary outcomes included the incidence of positive reactions caused by removing the femoral head, and by placing a retractor during femoral exposure; and the incidence of femoral nerve palsy, as detected using manual testing of the strength of the quadriceps muscle. Results. Positive reactions were significantly less frequent when the retractor was placed at the ten (15/94; 16.0%), 11 (12/94; 12.8%), or 12 o’clock positions (19/94; 20.2%), than at the one (37/94; 39.4%) or two o’clock positions (39/94; 41.5%) (p < 0.050). Positive reactions also occurred when the femoral head was removed (28/94; 29.8%), and when a retractor was placed around the proximal femur (34/94; 36.2%) or medial femur (27/94; 28.7%) during femoral exposure. After surgery, no patient had reduced strength in the quadriceps muscle. Conclusion. Placing the anterior acetabular retractor at the one or two o’clock positions (right hip; inferior positions) during THA-DAA can increase the rate of electromyographic signal changes in the femoral nerve. Thus, placing a retractor in these positions may increased the risk of the development of a femoral nerve palsy. Cite this article: Bone Joint J 2022;104-B(2):193–199


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 5 - 10
1 Jan 2020
Cawley DT Rajamani V Cawley M Selvadurai S Gibson A Molloy S

Aims. Intraoperative 3D navigation (ION) allows high accuracy to be achieved in spinal surgery, but poor workflow has prevented its widespread uptake. The technical demands on ION when used in patients with adolescent idiopathic scoliosis (AIS) are higher than for other more established indications. Lean principles have been applied to industry and to health care with good effects. While ensuring optimal accuracy of instrumentation and safety, the implementation of ION and its associated productivity was evaluated in this study for AIS surgery in order to enhance the workflow of this technique. The aim was to optimize the use of ION by the application of lean principles in AIS surgery. Methods. A total of 20 consecutive patients with AIS were treated with ION corrective spinal surgery. Both qualitative and quantitative analysis was performed with real-time modifications. Operating time, scan time, dose length product (measure of CT radiation exposure), use of fluoroscopy, the influence of the reference frame, blood loss, and neuromonitoring were assessed. Results. The greatest gains in productivity were in avoiding repeat intraoperative scans (a mean of 248 minutes for patients who had two scans, and a mean 180 minutes for those who had a single scan). Optimizing accuracy was the biggest factor influencing this, which was reliant on incremental changes to the operating setup and technique. Conclusion. The application of lean principles to the introduction of ION for AIS surgery helps assimilate this method into the environment of the operating theatre. Data and stakeholder analysis identified a reproducible technique for using ION for AIS surgery, reducing operating time, and radiation exposure. Cite this article: Bone Joint J. 2020;102-B(1):5–10


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1303 - 1309
1 Oct 2018
Nodzo SR Chang C Carroll KM Barlow BT Banks SA Padgett DE Mayman DJ Jerabek SA

Aims. The aim of this study was to evaluate the accuracy of implant placement when using robotic assistance during total hip arthroplasty (THA). Patients and Methods. A total of 20 patients underwent a planned THA using preoperative CT scans and robotic-assisted software. There were nine men and 11 women (n = 20 hips) with a mean age of 60.8 years (. sd. 6.0). Pelvic and femoral bone models were constructed by segmenting both preoperative and postoperative CT scan images. The preoperative anatomical landmarks using the robotic-assisted system were matched to the postoperative 3D reconstructions of the pelvis. Acetabular and femoral component positions as measured intraoperatively and postoperatively were evaluated and compared. Results. The system reported accurate values for reconstruction of the hip when compared to those measured postoperatively using CT. The mean deviation from the executed overall hip length and offset were 1.6 mm (. sd. 2.9) and 0.5 mm (. sd. 3.0), respectively. Mean combined anteversion was similar and correlated between intraoperative measurements and postoperative CT measurements (32.5°, . sd. 5.9° versus 32.2°, . sd. 6.4°; respectively; R. 2. = 0.65; p < 0.001). There was a significant correlation between mean intraoperative (40.4°, . sd. 2.1°) acetabular component inclination and mean measured postoperative inclination (40.12°, . sd. 3.0°, R. 2. = 0.62; p < 0.001). There was a significant correlation between mean intraoperative version (23.2°, . sd. 2.3°), and postoperatively measured version (23.0°, . sd. 2.4°; R. 2. = 0.76; p < 0.001). Preoperative and postoperative femoral component anteversion were significantly correlated with one another (R. 2. = 0.64; p < 0.001). Three patients had CT scan measurements that differed substantially from the intraoperative robotic measurements when evaluating stem anteversion. Conclusion. This is the first study to evaluate the success of hip reconstruction overall using robotic-assisted THA. The overall hip reconstruction obtained in the operating theatre using robotic assistance accurately correlated with the postoperative component position assessed independently using CT based 3D modelling. Clinical correlation during surgery should continue to be practiced and compared with observed intraoperative robotic values. Cite this article: Bone Joint J 2018;100-B:1303–9


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 372 - 377
1 Apr 2019
Zagra L Villa F Cappelletti L Gallazzi E Materazzi G De Vecchi E

Aims. Leucocyte esterase (LE) has been shown to be an accurate marker of prosthetic joint infection (PJI), and has been proposed as an alternative to frozen section (FS) histology for intraoperative diagnosis. In this study, the intraoperative assessment of LE was compared with FS histology for the diagnosis of prosthetic hip infection. Patients and Methods. A total of 119 patients undergoing revision total hip arthroplasty (THA) between June 2015 and December 2017 were included in the study. There were 56 men and 63 women with a mean age of 66.2 years (27 to 88). Synovial fluid was collected before arthrotomy for the assessment of LE using enzymatic colourimetric strips. Between five and six samples were stained with haematoxylin and eosin for FS histology, and considered suggestive of infection when at least five polymorphonuclear leucocytes were found in five high-power fields. Results. The sensitivity and specificity of the LE assay were 100% and 93.8%, respectively; the positive (PPV) and the negative (NPV) predictive values were 79.3% and 100%, respectively. The mean time between the collection of the sample and the result being known was 20.1 minutes (. sd. 4.4). The sensitivity and specificity of FS histology were 78.3% and 96.9%, respectively; the PPV and the NPV were 85.7% and 94.9%, respectively. The mean time between the collection of the sample and the result being known was 27.2 minutes (. sd. 6.9). Conclusion. The sensitivity of LE assay was higher, with similar specificity and diagnostic accuracy, compared with FS histology. The faster turnaround time, its ease of use, and low costs make LE assay a valuable alternative to FS histology. We now use it routinely for the intraoperative diagnosis of PJI. Cite this article: Bone Joint J 2019;101-B:372–377


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1129 - 1137
1 Sep 2019
Leer-Salvesen S Engesæter LB Dybvik E Furnes O Kristensen TB Gjertsen J

Aims. The aim of this study was to investigate mortality and risk of intraoperative medical complications depending on delay to hip fracture surgery by using data from the Norwegian Hip Fracture Register (NHFR) and the Norwegian Patient Registry (NPR). Patients and Methods. A total of 83 727 hip fractures were reported to the NHFR between 2008 and 2017. Pathological fractures, unspecified type of fractures or treatment, patients less than 50 years of age, unknown delay to surgery, and delays to surgery of greater than four days were excluded. We studied total delay (fracture to surgery, n = 38 754) and hospital delay (admission to surgery, n = 73 557). Cox regression analyses were performed to calculate relative risks (RRs) adjusted for sex, age, American Society of Anesthesiologists (ASA) classification, type of surgery, and type of fracture. Odds ratio (OR) was calculated for intraoperative medical complications. We compared delays of 12 hours or less, 13 to 24 hours, 25 to 36 hours, 37 to 48 hours, and more than 48 hours. Results. Mortality remained unchanged when total delay was less than 48 hours. Total delay exceeding 48 hours was associated with increased three-day mortality (RR 1.69, 95% confidence interval (CI) 1.23 to 2.34; p = 0.001) and one-year mortality (RR 1.06, 95% CI 1.04 to 1.22; p = 0.003). More intraoperative medical complications were reported when hospital delay exceeded 24 hours. Conclusion. Hospitals should operate on patients within 48 hours after fracture to reduce mortality and intraoperative complications. Cite this article: Bone Joint J 2019;101-B:1129–1137


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1358 - 1366
2 Aug 2021
Wei C Quan T Wang KY Gu A Fassihi SC Kahlenberg CA Malahias M Liu J Thakkar S Gonzalez Della Valle A Sculco PK

Aims. This study used an artificial neural network (ANN) model to determine the most important pre- and perioperative variables to predict same-day discharge in patients undergoing total knee arthroplasty (TKA). Methods. Data for this study were collected from the National Surgery Quality Improvement Program (NSQIP) database from the year 2018. Patients who received a primary, elective, unilateral TKA with a diagnosis of primary osteoarthritis were included. Demographic, preoperative, and intraoperative variables were analyzed. The ANN model was compared to a logistic regression model, which is a conventional machine-learning algorithm. Variables collected from 28,742 patients were analyzed based on their contribution to hospital length of stay. Results. The predictability of the ANN model, area under the curve (AUC) = 0.801, was similar to the logistic regression model (AUC = 0.796) and identified certain variables as important factors to predict same-day discharge. The ten most important factors favouring same-day discharge in the ANN model include preoperative sodium, preoperative international normalized ratio, BMI, age, anaesthesia type, operating time, dyspnoea status, functional status, race, anaemia status, and chronic obstructive pulmonary disease (COPD). Six of these variables were also found to be significant on logistic regression analysis. Conclusion. Both ANN modelling and logistic regression analysis revealed clinically important factors in predicting patients who can undergo safely undergo same-day discharge from an outpatient TKA. The ANN model provides a beneficial approach to help determine which perioperative factors can predict same-day discharge as of 2018 perioperative recovery protocols. Cite this article: Bone Joint J 2021;103-B(8):1358–1366


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1199 - 1208
1 Oct 2019
Lamb JN Matharu GS Redmond A Judge A West RM Pandit HG

Aims. We compared implant and patient survival following intraoperative periprosthetic femoral fractures (IOPFFs) during primary total hip arthroplasty (THA) with matched controls. Patients and Methods. This retrospective cohort study compared 4831 hips with IOPFF and 48 154 propensity score matched primary THAs without IOPFF implanted between 2004 and 2016, which had been recorded on a national joint registry. Implant and patient survival rates were compared between groups using Cox regression. Results. Ten-year stem survival was worse in the IOPFF group (p < 0.001). Risk of revision for aseptic loosening increased 7.2-fold following shaft fracture and almost 2.8-fold after trochanteric fracture (p < 0.001). Risk of periprosthetic fracture of the femur revision increased 4.3-fold following calcar-crack and 3.6-fold after trochanteric fracture (p < 0.01). Risk of instability revision was 3.6-fold after trochanteric fracture and 2.4-fold after calcar crack (p < 0.001). Risk of 90-day mortality following IOPFF without revision was 1.7-fold and 4.0-fold after IOPFF with early revision surgery versus uncomplicated THA (p < 0.001). Conclusion. IOPFF increases risk of stem revision and mortality up to ten years following surgery. The risk of revision depends on IOPFF subtype and mortality risk increases with subsequent revision surgery. Surgeons should carefully diagnose and treat IOPFF to minimize fracture progression and implant failure. Cite this article: Bone Joint J 2019;101-B:1199–1208


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 532 - 540
2 May 2022
Martin H Robinson PG Maempel JF Hamilton D Gaston P Safran MR Murray IR

There has been a marked increase in the number of hip arthroscopies performed over the past 16 years, primarily in the management of femoroacetabular impingement (FAI). Insights into the pathoanatomy of FAI, and high-level evidence supporting the clinical effectiveness of arthroscopy in the management of FAI, have fuelled this trend. Arthroscopic management of labral tears with repair may have superior results compared with debridement, and there is now emerging evidence to support reconstructive options where repair is not possible. In situations where an interportal capsulotomy is performed to facilitate access, data now support closure of the capsule in selective cases where there is an increased risk of postoperative instability. Preoperative planning is an integral component of bony corrective surgery in FAI, and this has evolved to include computer-planned resection. However, the benefit of this remains controversial. Hip instability is now widely accepted, and diagnostic criteria and treatment are becoming increasingly refined. Instability can also be present with FAI or develop as a result of FAI treatment. In this annotation, we outline major current controversies relating to decision-making in hip arthroscopy for FAI.

Cite this article: Bone Joint J 2022;104-B(5):532–540.


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 751 - 759
1 Jul 2023
Lu V Andronic O Zhang JZ Khanduja V

Aims

Hip arthroscopy (HA) has become the treatment of choice for femoroacetabular impingement (FAI). However, less favourable outcomes following arthroscopic surgery are expected in patients with severe chondral lesions. The aim of this study was to assess the outcomes of HA in patients with FAI and associated chondral lesions, classified according to the Outerbridge system.

Methods

A systematic search was performed on four databases. Studies which involved HA as the primary management of FAI and reported on chondral lesions as classified according to the Outerbridge classification were included. The study was registered on PROSPERO. Demographic data, patient-reported outcome measures (PROMs), complications, and rates of conversion to total hip arthroplasty (THA) were collected.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 90 - 94
1 Jan 2003
Takahashi S Kitagawa H Ishii T

Intraoperative pulmonary fat and bone-marrow embolism is a serious complication of bone and joint surgery. We have investigated the occurrence and incidence of intraoperative embolism in patients undergoing elective lumbar spinal surgery with or without instrumentation. Sixty adult patients with lumbar degenerative disease were examined by intraoperative transoesophageal echocardiography while undergoing posterior lumbar surgery. Of these, 40 underwent surgery with instrumentation and 20 without. Moderate to severe (grade 2 or 3 according to the grading scale of Pitto et al) embolic events were seen in 80% of the instrumented patients but in none of the non-instrumented patients (p < 0.001). The insertion of pedicle screws was particularly associated with large numbers of pulmonary emboli, while the surgical approach, laminectomy, disc removal and bone harvesting were associated with small numbers of emboli. We consider that, as in arthroplasty and intramedullary fixation of fractures, these embolic events are relevant to the development of potentially fatal fat embolism during spinal surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 731 - 733
1 Sep 1997
Haddad FS Harper GD Hill RA

We performed intraoperative arthrography of the knee in 12 children with congenital short femur, Blount’s disease or Ollier’s disease in whom the Ilizarov technique was used for correction of deformity, leg lengthening or both. In each case, arthrography revealed a joint surface considerably different from that assumed from plain radiographs, and resulted in a change in the placement of our reference wires before application of the frame. This gave significant improvement in the mechanical axis obtained at the time of removal of the frame. The technique is safe, cheap and easy to perform. It is a useful adjunct to the application of the Ilizarov frame when used for complex lengthening and correction of deformity in the leg


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 518 - 520
1 May 2002
Kakiuchi M

The systemic arterial pressure has been used as a guide for determining the susceptibility to surgical bleeding during controlled hypotensive anaesthesia. Arterial hypotension is not, however, necessarily accompanied by venous or intraosseous hypotension. The main source of bleeding during posterior spinal surgery is the bone and is venous rather than arterial. The intraoperative blood loss, the intraosseous pressure (IOP) within the first thoracic vertebral body, and the systemic arterial pressure were measured in 27 patients during cervical laminoplasty for spondylotic myelopathy. The intraoperative blood loss correlated significantly with the vertebral IOP (p = 0.0073, r = 0.499), but not with systemic arterial pressure, age, or body-weight. The systemic arterial pressure did not correlate with the vertebral IOP. The mean value of the mean arterial pressure throughout the operation varied between 74 and 110 mmHg. The findings suggest that the vertebral IOP parallels surgical bleeding during posterior spinal surgery under normotensive anaesthesia and that patients with a low arterial pressure do not necessarily have a low IOP


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 48 - 49
1 Jan 2000
Mant MJ Russell DB Johnston DWC Donahue PA

The administration of heparin during operation has been reported to enhance the efficacy of thromboprophylaxis in patients undergoing total hip replacement. We have performed a small pilot study in which intraoperative doses of heparin were given in addition to the usual postoperative thromboprophylaxis with enoxaparin in 32 patients undergoing total knee replacement. The primary endpoint was deep-vein thrombosis (DVT) as demonstrated by bilateral venography on 6 ± 2 days after operation. Sixteen patients developed DVT; in two the thrombosis was proximal as well as distal and in one the occurrence was bilateral. There was one major haemorrhage. These results are similar to those obtained with the use of postoperative thromboprophylaxis with enoxaparin alone. They do not provide support for the initiation of a larger randomised trial of this approach to management


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 776 - 776
1 Jul 2000
GUTOW A


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 886 - 889
1 Sep 1999
Davis N Curry A Gambhir AK Panigrahi H Walker CRC Wilkins EGL Worsley MA Kay PR

All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1075 - 1081
1 Sep 2002
Bull AMJ Earnshaw PH Smith A Katchburian MV Hassan ANA Amis AA

Our objectives were to establish the envelope of passive movement and to demonstrate the kinematic behaviour of the knee during standard clinical tests before and after reconstruction of the anterior cruciate ligament (ACL). An electromagnetic device was used to measure movement of the joint during surgery.

Reconstruction of the ACL significantly reduced the overall envelope of tibial rotation (10° to 90° flexion), moved this envelope into external rotation from 0° to 20° flexion, and reduced the anterior position of the tibial plateau (5° to 30° flexion) (p < 0.05 for all). During the pivot-shift test in early flexion there was progressive anterior tibial subluxation with internal rotation. These subluxations reversed suddenly around a mean position of 36 ± 9° of flexion of the knee and consisted of an external tibial rotation of 13 ± 8° combined with a posterior tibial translation of 12 ± 8 mm. This abnormal movement was abolished after reconstruction of the ACL.