There is increasing popularity in the use of artificial intelligence and machine-learning techniques to provide diagnostic and prognostic models for various aspects of Trauma & Orthopaedic surgery. However, correct
We performed a systematic review of the literature
to evaluate the use and
We obtained information from the Elective Orthopaedic
Centre on 1523 patients with baseline and six-month Oxford hip scores
(OHS) after undergoing primary hip replacement (THR) and 1784 patients
with Oxford knee scores (OKS) for primary knee replacement (TKR)
who completed a six-month satisfaction questionnaire. Receiver operating characteristic curves identified an absolute
change in OHS of 14 points or more as the point that discriminates
best between patients’ satisfaction levels and an 11-point change
for the OKS. Satisfaction is highest (97.6%) in patients with an
absolute change in OHS of 14 points or more, compared with lower
levels of satisfaction (81.8%) below this threshold. Similarly,
an 11-point absolute change in OKS was associated with 95.4% satisfaction
compared with 76.5% below this threshold. For the six-month OHS
a score of 35 points or more distinguished patients with the highest
satisfaction level, and for the six-month OKS 30 points or more identified
the highest level of satisfaction. The thresholds varied according
to patients’ pre-operative score, where those with severe pre-operative
pain/function required a lower six-month score to achieve the highest
levels of satisfaction. Our data suggest that the choice of a six-month follow-up to
assess patient-reported outcomes of THR/TKR is acceptable. The thresholds
help to differentiate between patients with different levels of
satisfaction, but external validation will be required prior to
general implementation in clinical practice.
Aims. The aim of this study was to investigate the agreement in
Aims. Clinical management of open fractures is challenging and frequently requires complex reconstruction procedures. The Gustilo-Anderson classification lacks uniform
Aims. We assessed the value of the Clinical Frailty Scale (CFS) in the prediction of adverse outcome after hip fracture. Methods. Of 1,577 consecutive patients aged > 65 years with a fragility hip fracture admitted to one institution, for whom there were complete data, 1,255 (72%) were studied. Clinicians assigned CFS scores on admission. Audit personnel routinely prospectively completed the Standardised Audit of Hip Fracture in Europe form, including the following outcomes: 30-day survival; in-hospital complications; length of acute hospital stay; and new institutionalization. The relationship between the CFS scores and outcomes was examined graphically and the visual
Aims. The aim of this study was to prepare a scoping review to investigate the use of biologic therapies in the treatment of musculoskeletal injuries in professional and Olympic athletes. Methods. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews and Arksey and O’Malley frameworks were followed. A three-step search strategy identified relevant published primary and secondary studies, as well as grey literature. The identified studies were screened with criteria for inclusion comprising clinical studies evaluating the use of biologic therapies in professional and Olympic athletes, systematic reviews, consensus statements, and conference proceedings. Data were extracted using a standardized tool to form a descriptive analysis and a thematic summary. Results. A total of 202 studies were initially identified, and 35 met criteria for the scoping review; 33 (94.3%) were published within the last eight years, and 18 (51.4%) originated from the USA. Platelet rich plasma was the most studied biologic therapy, being evaluated in 33 (94.3%) studies. Ulnar collateral ligament and hamstring injuries were the conditions most studied (nine (25.7%) studies and seven (20.0%) studies, respectively). Athletes most frequently participated in baseball, soccer, and American football. Only two (5.7%) studies were level 1 evidence, with
Aims. The diagnosis of periprosthetic joint infection (PJI) can be difficult. All current diagnostic tests have problems with accuracy and
Aims. Thresholds of acceptable early migration of the components in total knee arthroplasty (TKA) have traditionally ignored the effects of patient and implant factors that may influence migration. The aim of this study was to determine which of these factors are associated with overall longitudinal migration of well-fixed tibial components following TKA. Methods. Radiostereometric analysis (RSA) data over a two-year period were available for 419 successful primary TKAs (267 cemented and 152 uncemented in 257 female and 162 male patients). Longitudinal analysis of data using marginal models was performed to examine the associations of patient factors (age, sex, BMI, smoking status) and implant factors (cemented or uncemented, the size of the implant) with maximum total point motion (MTPM) migration. Analyses were also performed on subgroups based on sex and fixation. Results. In the overall group, only fixation was significantly associated with migration (p < 0.001). For uncemented tibial components in males, smoking was significantly associated with lower migration (p = 0.030) and BMI approached significance (p = 0.061). For females with uncemented components, smoking (p = 0.081) and age (p = 0.063) approached significance and were both associated with increased migration. The small number of self-reported smokers in this study warrants cautious
Aims. This study explores data quality in operation type and fracture classification recorded as part of a large research study and a national audit with an independent review. Patients and Methods. At 17 centres, an expert surgeon reviewed a randomly selected subset of cases from their centre with regard to fracture classification using the AO system and type of operation performed. Agreement for these variables was then compared with the data collected during conduct of the World Hip Trauma Evaluation (WHiTE) cohort study. Both types of surgery and fracture classification were collapsed to identify the level of detail of reporting that achieved meaningful agreement. In the National Hip Fracture Database (NHFD), the types of operation and fracture classification were explored to identify the proportion of “highly improbable” combinations. Results. The records were reviewed for 903 cases. Agreement for the subtypes of extracapsular fracture was poor; most centres achieved no better than “fair” agreement. When the classification was collapsed to a single option for “extracapsular” fracture, only four centres failed to have at least “moderate” agreement. There was only “moderate” agreement for the subtypes of intracapsular fracture, which improved to “substantial” when collapsed to “intracapsular”. Subtrochanteric fracture types were well reported with “substantial” agreement. There was near “perfect” agreement for internal fixation procedures. “Perfect” or “substantial” agreement was achieved when the type of arthroplasty surgery was reported at the level of “hemiarthroplasty” and “total hip replacement”. When reviewing data submitted to the NHFD, a minimum of 5.2% of cases contained “highly improbable” procedures for the stated fracture classification. Conclusion. The complexity of collecting fracture classification data at a national scale compromises the accuracy with which detailed classification systems can be reported. Data around type of surgery performed show similar tendencies. Data capture, reporting, and
Aims. We aimed to assess the comparability of data in joint replacement
registries and identify ways of improving the comparisons between
registries and the overall monitoring of joint replacement surgery. Materials and Methods. We conducted a review of registries that are full members of
the International Society of Arthroplasty Registries with publicly
available annual reports in English. Of the six registries which
were included, we compared the reporting of: mean age, definitions
for revision and re-operation, reasons for revision, the approach
to analysing revisions, and patient-reported outcome measures (PROMs)
for primary and revision total hip arthroplasty (THA) and hip resurfacing
arthroplasty (HRA). Results. Outcomes were infrequently reported for HRA compared with THA
and all hip arthroplasties. Revisions were consistently defined,
though re-operation was defined by one registry. Implant survival
was most commonly reported as the cumulative incidence of revision
using Kaplan-Meier survival analysis. Three registries reported patient
reported outcome measures. . Conclusion. More consistency in the reporting of outcomes for specific types
of procedures is needed to improve the
Two major complications of hip replacement are loosening and infection. Reliable differentiation between these pathological processes is difficult since both may be accompanied by similar symptoms. Our aim was to assess the diagnostic ability of triple-phase bone scanning (TPBS) and positron-emission tomography (PET) to detect and differentiate these complications in patients with a hip arthroplasty. Both TPBS and PET were performed in 63 patients (92 prostheses). The radiotracer for PET imaging was . 18. F-fluorodeoxyglucose (FDG). Image
Intra-articular (IA) tumours around the knee are treated with extra-articular (EA) resection, which is associated with poor functional outcomes. We aim to evaluate the accuracy of MRI in predicting IA involvement around the knee. We identified 63 cases of high-grade sarcomas in or around the distal femur that underwent an EA resection from a prospectively maintained database (January 1996 to April 2020). Suspicion of IA disease was noted in 52 cases, six had IA pathological fracture, two had an effusion, two had prior surgical intervention (curettage/IA intervention), and one had an osseous metastasis in the proximal tibia. To ascertain validity, two musculoskeletal radiologists (R1, R2) reviewed the preoperative imaging (MRI) of 63 consecutive cases on two occasions six weeks apart. The radiological criteria for IA disease comprised evidence of tumour extension within the suprapatellar pouch, intercondylar notch, extension along medial/lateral retinaculum, and presence of IA fracture. The radiological predictions were then confirmed with the final histopathology of the resected specimens.Aims
Methods
Aims. α-defensin is a biomarker which has been described as having
a high degree of accuracy in the diagnosis of periprosthetic joint
infection (PJI). Current meta-analyses are based on the α-defensin
laboratory-based immunoassay rather than the quick on-table lateral
flow test kit. This study is the first meta-analysis to compare the
accuracy of the α-defensin laboratory-based immunoassay and the
lateral flow test kit for the diagnosis of PJI. Materials and Methods. A systematic review was performed according to the Preferred
Reporting Items for Systematic Reviews and Meta-Analyses guidelines.
Inclusion criteria were all clinical studies where the diagnosis
of PJI was uncertain. All studies selected used the Musculoskeletal
Infection Society (MSIS) or modified MSIS criteria. Two independent
reviewers reviewed the studies and extracted data. A meta-analysis
of results was carried out: pooled sensitivity, specificity, positive
and negative likelihood ratio, heterogeneity and areas under curves
are reported. Results. Ten studies (759 patients) were included. Of these, seven studies
(640 patients) evaluated the laboratory-based α-defensin immunoassay
and three (119 patients) the lateral flow test. The pooled sensitivity
and specificity of the qualitative α-defensin laboratory immunoassay
was 0.953 (95% confidence interval (CI) 0.87 to 0.984) and 0.965 (95%
CI 0.943 to 0.979) respectively. The pooled positive likelihood
ratio (PLR) and negative likelihood ratio (NLR) were 34.86 (95%
CI 19.34 to 62.85) and 0.02 (95% CI 0.00 to 0.11). The pooled sensitivity
and specificity of the lateral flow test were 0.774 (95% CI 0.637
to 0.870) and 0.913 (95% CI 0.828 to 0.958), respectively. The pooled
PLR and NLR were 8.675 (95% CI 4.229 to 17.794) and 0.248 (95% CI
0.147 to 0.418), respectively. Conclusion. The pooled sensitivity and specificity of the lateral flow test
were lower than those of the
α-defensin laboratory-based immunoassay test. Hence, care must be
taken with
Ultrasonography of the hip was performed sequentially by two different examiners in 75 infants. The ultrasound strips were reviewed twice by three paediatric orthopaedic surgeons and classified by the Graf method. The intraobserver and interobserver agreement between the