Advertisement for orthosearch.org.uk
Results 1 - 20 of 36
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 398 - 404
1 Mar 2012
Seide K Aljudaibi M Weinrich N Kowald B Jürgens C Müller J Faschingbauer M

In an interdisciplinary project involving electronic engineers and clinicians, a telemetric system was developed to measure the bending load in a titanium internal femoral fixator. As this was a new device, the main question posed was: what clinically relevant information could be drawn from its application? As a first clinical investigation, 27 patients (24 men, three women) with a mean age of 38.4 years (19 to 66) with femoral nonunions were treated using the system. The mean duration of the nonunion was 15.4 months (5 to 69). The elasticity of the plate-callus system was measured telemetrically until union. Conventional radiographs and a CT scan at 12 weeks were performed routinely, and healing was staged according to the CT scans. All nonunions healed at a mean of 21.5 weeks (13 to 37). Well before any radiological signs of healing could be detected, a substantial decrease in elasticity was recorded. The relative elasticity decreased to 50% at a mean of 7.8 weeks (3.5 to 13) and to 10% at a mean of 19.3 weeks (4.5 to 37). At 12 weeks the mean relative elasticity was 28.1% (0% to 56%). The relative elasticity was significantly different between the different healing stages as determined by the CT scans.

Incorporating load measuring electronics into implants is a promising option for the assessment of bone healing. Future application might lead to a reduction in the need for exposure to ionising radiation to monitor fracture healing.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1232 - 1236
1 Sep 2017
Dahill M McArthur J Roberts GL Acharya MR Ward AJ Chesser TJS

Aims. The anterior pelvic internal fixator is increasingly used for the treatment of unstable, or displaced, injuries of the anterior pelvic ring. The evidence for its use, however, is limited. The aim of this paper is to describe the indications for its use, how it is applied and its complications. Patients and Methods. We reviewed the case notes and radiographs of 50 patients treated with an anterior pelvic internal fixator between April 2010 and December 2015 at a major trauma centre in the United Kingdom. The median follow-up time was 38 months (interquartile range 24 to 51). Results. Three patients were excluded from the analysis leaving 47 patients with complete follow-up data. Of the 47 patients, 46 achieved radiological union and one progressed to an asymptomatic nonunion. Of the remaining patients, 45 required supplementary posterior fixation with percutaneous iliosacral screws, 2 of which required sacral plating. The incidence of injury to the lateral femoral cutaneous nerve (LFCN) was 34%. The rate of infection was 2%. There were no other significant complications. Without this treatment, 44 patients (94%) would have needed unilateral or bilateral open reduction and plate fixation extending laterally to the hip joint. Conclusion. The anterior pelvic internal fixator reduces the need for extensive open surgery and is a useful addition to the armamentarium for the treatment of anterior pelvic injuries. It is associated with injury to the LFCN in a third of patients. Cite this article: Bone Joint J 2017;99-B.1232–6


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 7 - 10
1 Nov 2013
Petrie J Sassoon A Haidukewych GJ

Most hip fractures treated with modern internal fixation techniques will heal. However, failures occasionally occur and require revision procedures. Salvage strategies employed during revision are based on whether the fixation failure occurs in the femoral neck, or in the intertrochanteric region. Patient age and remaining bone stock also influence decision making. For fractures in young patients, efforts are generally focused on preserving the native femoral head via osteotomies and repeat internal fixation. For failures in older patients, some kind of hip replacement is usually selected. Disuse osteopenia, deformity, bone loss, and stress-risers from previous internal fixation devices all pose technical challenges to successful reconstruction. Attention to detail is important in order to minimise complications. In the majority of cases, good outcomes have been reported for the various salvage strategies. Cite this article: Bone Joint J 2013;95-B, Supple A:7–10


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1519 - 1521
1 Nov 2007
Khunda A Stirrat AN Dunlop P

The proximal humerus internal locking system is an internal fixation device consisting of a low-profile plate and locking screws, which is used for the fixation of three- and four-part fractures of the proximal humerus. We describe a case in which the screws cut out of the humeral head causing injury to the axillary artery necessitating urgent removal of the implant


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 208 - 212
1 Mar 1986
Macdonald W Thrum C Hamilton S

Techniques are described by which metal implants can be designed and produced to fit precisely a bony site at a subsequent operation. CT scans and solid modelling were used to produce an accurate three-dimensional representation of the surface of the bone. These techniques were applied to the production of an internal fixation device for shoulder arthrodesis after the resection of a neoplasm of the proximal humerus. The reconstruction utilised a free vascularised fibular graft between the scapula and the distal humeral remnant, fixation being secured with the custom-made implant


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 703 - 708
1 Jun 2022
Najefi A Zaidi R Chan O Hester T Kavarthapu V

Aims

Surgical reconstruction of deformed Charcot feet carries a high risk of nonunion, metalwork failure, and deformity recurrence. The primary aim of this study was to identify the factors contributing to these complications following hindfoot Charcot reconstructions.

Methods

We retrospectively analyzed patients who underwent hindfoot Charcot reconstruction with an intramedullary nail between January 2007 and December 2019 in our unit. Patient demographic details, comorbidities, weightbearing status, and postoperative complications were noted. Metalwork breakage, nonunion, deformity recurrence, concurrent midfoot reconstruction, and the measurements related to intramedullary nail were also recorded.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1611 - 1618
1 Oct 2021
Kavarthapu V Budair B

Aims

In our unit, we adopt a two-stage surgical reconstruction approach using internal fixation for the management of infected Charcot foot deformity. We evaluate our experience with this functional limb salvage method.

Methods

We conducted a retrospective analysis of prospectively collected data of all patients with infected Charcot foot deformity who underwent two-stage reconstruction with internal fixation between July 2011 and November 2019, with a minimum of 12 months’ follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 833 - 839
1 Sep 1998
Oner FC van der Rijt RR Ramos LMP Dhert WJA Verbout AJ

We have studied the intervertebral discs adjacent to fractured vertebral bodies using MRI in 63 patients at a minimum of 18 months after injury. There were 75 thoracolumbar fractures of which 26 were treated conservatively and 37 by posterior reduction and fusion with an AO internal fixator. We identified six different types of disc using criteria based on the morphology and the intensity of the MRI signal. The inter- and intraobserver variability of this system was good. Most of the discs showed predominantly morphological changes with no variation in signal intensity. Some disc types were associated with progressive kyphosis in patients treated conservatively. In those managed by operation, recurrent kyphosis appeared to result from creeping of the disc in the central depression of the bony endplate rather than from disc degeneration. Changes in the disc space after posterior fixation should not be seen as a form of chronic instability but as a redistribution of the disc tissue in the changed morphology of the space after fractures of the endplate


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 249 - 256
1 Feb 2005
Trebse R Pisot V Trampuz A

We have prospectively studied the outcome of infections associated with implants which were retained and treated using a standardised antimicrobial protocol. Over a period of four years, we studied 24 consecutive patients who had symptoms of infection for less than one year, a stable implant, no sinus tract and a known pathogen which was susceptible to recommended antimicrobial agents. The infections involved hip prostheses (14), knee prostheses (5), an internal fixation device (4), and an ankle prosthesis (1). Twenty patients had a successful outcome at a median follow-up of 3.7 years (1.8 to 4.7); four had failure of the implant after a median follow-up of 1.2 years (0.3 to 2.5). The probability of survival without failure of treatment was 96% at one year (95% confidence interval (CI) 88 to 100), 92% at two years (95% CI 80 to 100) and 86% at three years (95% CI 72 to 100). Patients with a short-term infection but with a stable implant, no sinus tract and a known pathogen may be successfully treated by retention of the implant and the use of a standardised regimen of antimicrobial treatment


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 359 - 367
1 Mar 2022
Deere K Matharu GS Ben-Shlomo Y Wilkinson JM Blom AW Sayers A Whitehouse MR

Aims

A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database.

Methods

Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined.


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 427 - 484
1 Aug 1981
Uhthoff H Bardos D Liskova-Kiar M

An experimental study is reported of fracture healing in the femora of 36 Beagle dogs, comparing the results of using stainless steel plates with those of using less rigid titanium alloy plates. The alloy plates led to the appearance of a small amount of periosteal callus without any histological evidence of fracture instability, thus allowing the radiological assessment of fracture union. This also produced less bone loss during the remodelling phase. Radiological measurements 24 weeks after osteotomy showed cortical thickness to be reduced by six per cent under titanium alloy and by 19 per cent under stainless steel, while histological measurements showed a total bone loss of 3.7 per cent under titanium alloy and of 11 per cent under stainless steel plates. Removal of the titanium alloy plates after eight weeks followed by a recovery period of 16 weeks produced an increase of cortical thickness of 69 per cent and a gain in total bone mass of 30 per cent. Titanium alloy plates also produced less soft-tissue reaction than stainless steel plates. It is concluded that this alloy is a promising material for internal fixation devices


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 959 - 966
1 Sep 2000
Gopal S Majumder S Batchelor AGB Knight SL De Boer P Smith RM

We performed a retrospective review of the case notes of 84 consecutive patients who had suffered a severe (Gustilo IIIb or IIIc) open fracture of the tibia after blunt trauma between 1990 and 1998. All had been treated by a radical protocol which included early soft-tissue cover with a muscle flap by a combined orthopaedic and plastic surgery service. Our ideal management is a radical debridement of the wound outside the zone of injury, skeletal stabilisation and early soft-tissue cover with a vascularised muscle flap. All patients were followed clinically and radiologically to union or for one year. After exclusion of four patients (one unrelated death and three patients lost to follow-up), we reviewed 80 patients with 84 fractures. There were 67 men and 13 women with a mean age of 37 years (3 to 89). Five injuries were grade IIIc and 79 grade IIIb; 12 were site 41, 43 were site 42 and 29 were site 43. Debridement and stabilisation of the fracture were invariably performed immediately. In 33 cases the soft-tissue reconstruction was also completed in a single stage, while in a further 30 it was achieved within 72 hours. In the remaining 21 there was a delay beyond 72 hours, often for critical reasons unrelated to the limb injury. All grade-IIIc injuries underwent immediate vascular reconstruction, with an immediate cover by a flap in two. All were salvaged. There were four amputations, one early, one mid-term and two late, giving a final rate of limb salvage of 95%. Overall, nine pedicled and 75 free muscle flaps were used; the rate of flap failure was 3.5%. Stabilisation of the fracture was achieved with 19 external and 65 internal fixation devices (nails or plates). Three patients had significant segmental defects and required bone-transport procedures to achieve bony union. Of the rest, 51 fractures (66%) progressed to primary bony union while 26 (34%) required a bone-stimulating procedure to achieve this outcome. Overall, there was a rate of superficial infection of the skin graft of 6%, of deep infection at the site of the fracture of 9.5%, and of serious pin-track infection of 37% in the external fixator group. At final review all patients were walking freely on united fractures with no evidence of infection. The treatment of these very severe injuries by an aggressive combined orthopaedic and plastic surgical approach provides good results; immediate internal fixation and healthy soft-tissue cover with a muscle flap is safe. Indeed, delay in cover (> 72 hours) was associated with most of the problems. External fixation was associated with practical difficulties for the plastic surgeons, a number of chronic pin-track infections and our only cases of malunion. We prefer to use internal fixation. We recommend primary referral to a specialist centre whenever possible. If local factors prevent this we suggest that after discussion with the relevant centre, initial debridement and bridging external fixation, followed by transfer, is the safest procedure


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 345 - 351
1 Mar 2020
Pitts C Alexander B Washington J Barranco H Patel R McGwin G Shah AB

Aims

Tibiotalocalcaneal (TTC) fusion is used to treat a variety of conditions affecting the ankle and subtalar joint, including osteoarthritis (OA), Charcot arthropathy, avascular necrosis (AVN) of the talus, failed total ankle arthroplasty, and severe deformity. The prevalence of postoperative complications remains high due to the complexity of hindfoot disease seen in these patients. The aim of this study was to analyze the relationship between preoperative conditions and postoperative complications in order to predict the outcome following primary TTC fusion.

Methods

We retrospectively reviewed the medical records of 101 patients who underwent TTC fusion at the same institution between 2011 and 2019. Risk ratios (RRs) associated with age, sex, diabetes, cardiovascular disease, smoking, preoperative ankle deformity, and the use of bone graft during surgery were related to the postoperative complications. We determined from these data which pre- and perioperative factors significantly affected the outcome.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 755 - 760
1 Jun 2018
Lou T Hamushan M Li H Wang C Chai Y Han P

Aims

The aim of this study was to describe the technique of distraction osteogenesis followed by arthrodesis using internal fixation to manage complex conditions of the ankle, and to present the results of this technique.

Patients and Methods

Between 2008 and 2014, distraction osteogenesis followed by arthrodesis using internal fixation was performed in 12 patients with complex conditions of the ankle due to trauma or infection. There were eight men and four women: their mean age was 35 years (23 to 51) at the time of surgery. Bone healing and functional recovery were evaluated according to the criteria described by Paley. Function was assessed using the ankle-hindfoot scale of the American Orthopedic Foot and Ankle Society (AOFAS).


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 973 - 983
1 Jul 2018
Schmal H Froberg L S. Larsen M Südkamp NP Pohlemann T Aghayev E Goodwin Burri K

Aims

The best method of treating unstable pelvic fractures that involve the obturator ring is still a matter for debate. This study compared three methods of treatment: nonoperative, isolated posterior fixation and combined anteroposterior stabilization.

Patients and Methods

The study used data from the German Pelvic Trauma Registry and compared patients undergoing conservative management (n = 2394), surgical treatment (n = 1345) and transpubic surgery, including posterior stabilization (n = 730) with isolated posterior osteosynthesis (n = 405) in non-complex Type B and C fractures that only involved the obturator ring anteriorly. Calculated odds ratios were adjusted for potential confounders. Outcome criteria were intraoperative and general short-term complications, the incidence of nerve injuries, and mortality.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 283 - 288
1 Feb 2017
Hughes A Heidari N Mitchell S Livingstone J Jackson M Atkins R Monsell F

Aims

Computer hexapod assisted orthopaedic surgery (CHAOS), is a method to achieve the intra-operative correction of long bone deformities using a hexapod external fixator before definitive internal fixation with minimally invasive stabilisation techniques.

The aims of this study were to determine the reliability of this method in a consecutive case series of patients undergoing femoral deformity correction, with a minimum six-month follow-up, to assess the complications and to define the ideal group of patients for whom this treatment is appropriate.

Patients and Methods

The medical records and radiographs of all patients who underwent CHAOS for femoral deformity at our institution between 2005 and 2011 were retrospectively reviewed. Records were available for all 55 consecutive procedures undertaken in 49 patients with a mean age of 35.6 years (10.9 to 75.3) at the time of surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 11 | Pages 1575 - 1580
1 Nov 2005
Böstman OM Laitinen OM Tynninen O Salminen ST Pihlajamäki HK

Despite worldwide clinical use of bio-absorbable devices for internal fixation in orthopaedic surgery, the degradation behaviour and tissue replacement of these implants are not fully understood.

In a long-term experimental study, we have determined the patterns of tissue restoration 36 and 54 months after implantation of polyglycolic acid and poly-laevo-lactic acid screws in the distal femur of the rabbit.

After 36 months in the polyglycolic acid group the specimens showed no remaining polymer and loose connective tissue occupied 80% of the screw track. Tissue restoration remained poor at 54 months, the amounts of trabecular bone and haematopoietic elements being significantly lower than those in the intact control group. The amount of trabecular bone within the screw track at 54 months in the polyglycolic acid group was less than in the empty drill holes (p = 0.04). In the poly-laevo-lactic acid group, polymeric material was present in abundance after 54 months, occupying 60% of the cross-section of the core area of the screw track.

When using absorbable internal fixation implants we should recognise that the degradation of the devices will probably not be accompanied by the restoration of normal trabecular bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 897 - 903
1 Jul 2011
Bachhal V Sankhala SS Jindal N Dhillon MS

We report the outcome of 32 patients (37 knees) who underwent hemicallostasis with a dynamic external fixator for osteoarthritis of the medial compartment of the knee. There were 16 men (19 knees) and 16 women (18 knees) with a mean age at operation of 54.6 years (27 to 72). The aim was to achieve a valgus overcorrection of 2° to 8° or mechanical axis at 62.5% (± 12.5%). At a mean follow-up of 62.8 months (51 to 81) there was no change in the mean range of movement, and no statistically significant difference in the Insall-Salvati index or tibial slope (p = 0.11 and p = 0.15, respectively). The mean hip-knee-ankle angle changed from 190.6 (183° to 197°) to 176.0° (171° to 181°), with a mean final position of the mechanical axis of 58.5% (35.1% to 71.2%).

The desired alignment was attained in 31 of 37 (84%) knees. There were 21 excellent, 13 good, two fair and one poor result according to the Oxford knee score with no correlation between age and final score. This score was at its best at one year with a statistically significant deterioration at two years (p = 0.001) followed by a small but not statistically significant deterioration until the final follow-up (p = 0.17). All the knees with Ahlback grade 1 osteoarthritis had excellent or good results. Complications included pin tract infections involving 16.4% of all pins used, delayed union in two, knee stiffness in four, fracture of the lateral cortex in one and ring sequestrum in one.

In conclusion, hemicallostasis provides precision in attaining the desired alignment without interfering with tibial slope or patellar height, and is relatively free of serious complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 159 - 163
1 Jan 2010
Aykut S Öztürk A Özkan Y Yanik K İlman AA Özdemir RM

We studied the effects of coating titanium implants with teicoplanin and clindamycin in 30 New Zealand White rabbits which were randomly assigned to three groups. The intramedullary canal of the left tibia of each rabbit was inoculated with 500 colony forming units of Staphylococcus aureus. Teicoplanin-coated implants were implanted into rabbits in group 1, clindamycin-coated implants into rabbits in group 2, and uncoated implants into those in group 3. All the rabbits were killed one week later. The implants were removed and cultured together with pieces of tibial bone and wound swabs. The rate of colonisation of the organisms in the three groups was compared.

Organisms were cultured from no rabbits in group 1, one in group 2 but from all in group 3. There was no significant difference between groups 1 and 2 (p = 1.000). There were significant differences between groups 1 and 3 and groups 2 and 3 (p < 0.001). Significant protection against bacterial colonisation and infection was found with teicoplanin- and clindamycin-coated implants in this experimental model.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 76 - 82
1 Jan 2015
Siebachmeyer M Boddu K Bilal A Hester TW Hardwick T Fox TP Edmonds M Kavarthapu V

We report the outcomes of 20 patients (12 men, 8 women, 21 feet) with Charcot neuro-arthropathy who underwent correction of deformities of the ankle and hindfoot using retrograde intramedullary nail arthrodesis. The mean age of the patients was 62.6 years (46 to 83); their mean BMI was 32.7 (15 to 47) and their median American Society of Anaesthetists score was 3 (2 to 4). All presented with severe deformities and 15 had chronic ulceration. All were treated with reconstructive surgery and seven underwent simultaneous midfoot fusion using a bolt, locking plate or a combination of both. At a mean follow-up of 26 months (8 to 54), limb salvage was achieved in all patients and 12 patients (80%) with ulceration achieved healing and all but one patient regained independent mobilisation. There was failure of fixation with a broken nail requiring revision surgery in one patient. Migration of distal locking screws occurred only when standard screws had been used but not with hydroxyapatite-coated screws. The mean American Academy of Orthopaedic Surgeons Foot and Ankle (AAOS-FAO) score improved from 50.7 (17 to 88) to 65.2 (22 to 88), (p = 0.015). The mean Short Form (SF)-36 Health Survey Physical Component Score improved from 25.2 (16.4 to 42.8) to 29.8 (17.7 to 44.2), (p = 0.003) and the mean Euroqol EQ‑5D‑5L score improved from 0.63 (0.51 to 0.78) to 0.67 (0.57 to 0.84), (p = 0.012).

Single-stage correction of deformity using an intramedullary hindfoot arthrodesis nail is a good form of treatment for patients with severe Charcot hindfoot deformity, ulceration and instability provided a multidisciplinary care plan is delivered.

Cite this article: Bone Joint J 2015;97-B:76–82.