Eight-plates are used to correct varus-valgus deformity (VVD) or limb-length discrepancy (LLD) in children and adolescents. It was reported that these implants might create a bony deformity within the knee joint by change of the roof angle (RA) after epiphysiodesis of the proximal tibia following a radiological assessment limited to anteroposterior (AP) radiographs. The aim of this study was to analyze the RA, complemented with lateral knee radiographs, with focus on the tibial slope (TS) and the degree of deformity correction. A retrospective, single-centre study was conducted. The treatment group (n = 64 knees in 44 patients) was subclassified according to the implant location in two groups: 1) medial hemiepiphysiodesis; and 2) lateral hemiepiphysiodesis. A third control group consisted of 25 untreated knees. The limb axes and RA were measured on long standing AP leg radiographs. Lateral radiographs of 40 knees were available for TS analysis. The mean age of the patients was 10.6 years (4 to 15) in the treatment group and 8.4 years (4 to 14) in the control group. Implants were removed after a mean 1.2 years (0.5 to 3).Aims
Methods
We describe three cases of infantile tibia vara
resulting from an atraumatic slip of the proximal tibial epiphysis
upon the metaphysis. There appears to be an association between
this condition and severe obesity. Radiologically, the condition
is characterised by a dome-shaped metaphysis, an open growth plate
and disruption of the continuity between the lateral borders of
the epiphysis and metaphysis, with inferomedial translation of the
proximal tibial epiphysis. All patients were treated by realignment
of the proximal tibia by distraction osteogenesis with an external
circulator fixator, and it is suggested that this is the optimal
method for correction of this complex deformity. There are differences
in the radiological features and management between conventional
infantile Blount’s disease and this ‘slipped upper tibial epiphysis’
variant.