Aims. The benefit of MRI in the preoperative assessment of scaphoid proximal fragment vascularity remains controversial. The purpose of this study is to compare preoperative MRI findings to intraoperative bleeding of the proximal scaphoid. Methods. A retrospective review of 102 patients who underwent surgery for scaphoid nonunion between January 2000 and December 2020 at a single institution were identified. Inclusion criteria were: isolated scaphoid nonunion; preoperative MRI assessing the proximal fragment vascularity; and operative details of the vascularity of the proximal fragment with the tourniquet deflated. MRI results and intraoperative findings were dichotomized as either ‘yes’ or ‘no’ for the presence of vascularity. A four-fold contingency table was used to analyze the utility of preoperative MRI with 95% confidence intervals. Relative risk was calculated for subgroups to analyze the association between variables and MRI accuracy. Results. Preoperative MRI identified 55 proximal scaphoid fragments with ischaemia and 47 with vascularized proximal fragments. After the proximal fragment was prepared, the tourniquet was deflated and assessed for bleeding; 63 proximal fragments had no bleeding and 39 demonstrated bleeding. MRI was not reliable or accurate in the assessment of proximal fragment vascularity when compared with intraoperative assessment of bleeding. No patient or MRI factors were identified to have a statistical impact on MRI accuracy. Conclusion. Current preoperative MRI protocols and diagnostic criteria do not provide a high degree of correlation with observed intraoperative assessment of proximal fragment bleeding. While preoperative MRI may assist in surgical planning, intraoperative assessment remains the best means for assessing proximal fragment vascularity in scaphoid nonunion.
It is not clear which type of casting provides the best initial treatment in adults with a distal radial fracture. Given that between 32% and 64% of adequately reduced fractures redisplace during immobilization in a cast, preventing redisplacement and a disabling malunion or secondary surgery is an aim of treatment. In this study, we investigated whether circumferential casting leads to fewer fracture redisplacements and better one-year outcomes compared to plaster splinting. In a pragmatic, open-label, multicentre, two-period cluster-randomized superiority trial, we compared these two types of casting. Recruitment took place in ten hospitals. Eligible patients aged ≥ 18 years with a displaced distal radial fracture, which was acceptably aligned after closed reduction, were included. The primary outcome measure was the rate of redisplacement within five weeks of immobilization. Secondary outcomes were the rate of complaints relating to the cast, clinical outcomes at three months, patient-reported outcome measures (PROMs) (using the numerical rating scale (NRS), the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores), and adverse events such as the development of compartment syndrome during one year of follow-up. We used multivariable mixed-effects logistic regression for the analysis of the primary outcome measure.Aims
Methods
The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.Aims
Methods
We aimed to compare reoperations following distal radial fractures (DRFs) managed with early fixation versus delayed fixation following initial closed reduction (CR). We used administrative databases in Ontario, Canada, to identify DRF patients aged 18 years or older from 2003 to 2016. We used procedural and fee codes within 30 days to determine which patients underwent early fixation (≤ seven days) or delayed fixation following CR. We grouped patients in the delayed group by their time to definitive fixation (eight to 14 days, 15 to 21 days, and 22 to 30 days). We used intervention and diagnostic codes to identify reoperations within two years. We used multivariable regression to compare the association between early versus delayed fixation and reoperation for all patients and stratified by age (18 to 60 years and > 60 years).Aims
Methods
To analyze the short-term outcome of two types of total wrist arthroplasty (TWA) in terms of wrist function, migration, and periprosthetic bone behaviour. A total of 40 patients suffering from non-rheumatoid wrist arthritis were enrolled in a randomized controlled trial comparing the ReMotion and Motec TWAs. Patient-rated and functional outcomes, radiological changes, blood metal ion levels, migration measured by model-based radiostereometric analysis (RSA), bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA), complications, loosening, and revision rates at two years were compared.Aims
Methods
The aim of the Scaphoid Waist Internal Fixation for Fractures Trial (SWIFFT) was to determine the optimal treatment for adults with a bicortical undisplaced or minimally displaced fracture of the waist of the scaphoid, comparing early surgical fixation with initial cast immobilization, with immediate fixation being offered to patients with nonunion. A cost-effectiveness analysis was conducted to assess the relative merits of these forms of treatment. The differences in costs to the healthcare system and quality-adjusted life years (QALYs) of the patients over the one-year follow-up of the trial in the two treatment arms were estimated using regression analysis.Aims
Methods
Patients with a triangular fibrocartilage complex (TFCC) injury report ulnar-sided wrist pain and impaired function. The surgical procedure of TFCC reinsertion aims to improve function in patients with this injury in whom conservative treatment has failed. The purpose of this study was to investigate the outcomes of open TFCC reinsertion. The study involved 274 patients who underwent open repair of the TFCC between December 2013 and December 2018. The patients completed the Patient-Rated Wrist Evaluation (PRWE) questionnaire, and scored pain and function using a visual analogue scale (VAS). Range of motion (ROM) was assessed by experienced hand therapists.Aims
Methods
With novel promising therapies potentially limiting progression of Dupuytren’s disease (DD), better patient stratification is needed. We aimed to quantify DD development and progression after seven years in a population-based cohort, and to identify factors predictive of disease development or progression. All surviving participants from our previous prevalence study were invited to participate in the current prospective cohort study. Participants were examined for presence of DD and Iselin’s classification was applied. They were asked to complete comprehensive questionnaires. Disease progression was defined as advancement to a further Iselin stage or surgery. Potential predictive factors were assessed using multivariable regression analyses. Of 763 participants in our original study, 398 were available for further investigation seven years later.Aims
Methods
We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves.Aims
Methods
In the UK, fasciectomy for Dupuytren’s contracture is generally performed under general or regional anaesthetic, with an arm tourniquet and in a hospital setting. We have changed our practice to use local anaesthetic with adrenaline, no arm tourniquet, and perform the surgery in a community setting. We present the outcome of a consecutive series of 30 patients. Prospective data were collected for 30 patients undergoing open fasciectomy on 36 digits (six having two digits affected), over a one-year period and under the care of two surgeons. In total, 10 ml to 20 ml volume of 1% lidocaine with 1:100,000 adrenaline was used. A standard postoperative rehabilitation regime was used. Preoperative health scores, goniometer measurements of metacarpophalangeal (MCP), proximal interphalangeal (PIP) contractures, and Unité Rheumatologique des Affections de la Main (URAM) scores were measured pre- and postoperatively at six and 12 weeks.Aims
Methods
The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging. A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.Aims
Methods
Base of thumb osteoarthritis (BTOA) is a common age-related disease which has a significant negative impact upon quality of life. Our aim was to assess current UK practice in secondary care with regard to the nature of non-surgical treatments, the surgical procedures most commonly performed, and factors influencing the surgical decision-making process. Ten consecutive patients undergoing surgery for BTOA between March 2017 and May 2019 were prospectively identified in 15 UK centres. Demographic details, duration of symptoms, radiological grade, non-surgical management strategies, and surgery conducted were recorded. A supplementary consultant questionnaire consisting of four multiple-choice-questions (MCQ) based on hypothetical clinical scenarios was distributed.Aims
Methods
Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture. Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The observers were asked to determine the presence of a scaphoid or other fracture and to classify the scaphoid fracture based on the Herbert classification system. Fleiss kappa statistics were used to calculate the interobserver agreement for the diagnosis of a fracture. Intraclass correlation coefficients (ICCs) were used to assess the agreement for the classification of scaphoid fracture.Aims
Methods
Carpal malalignment after a distal radial fracture occurs due to loss of volar tilt. Several studies have shown that this has an adverse influence on function. We aimed to investigate the magnitude of dorsal tilt that leads to carpal malalignment, whether reduction of dorsal tilt will correct carpal malalignment, and which measure of carpal malalignment is the most useful. Radiographs of patients with a distal radial fracture were prospectively collected and reviewed. Measurements of carpal malalignment were recorded on the initial radiograph, the radiograph following reduction of the fracture, and after a further interval. Linear regression modelling was used to assess the relationship between dorsal tilt and carpal malalignment. Receiver operating characteristic (ROC) analysis was used to identify which values of dorsal tilt led to carpal malalignment.Aims
Methods
The aim of this study was to test the null hypothesis that there
is no difference, from the payer perspective, in the cost of treatment
of a distal radial fracture in an elderly patient, aged >
65 years,
between open reduction and internal fixation (ORIF) and closed reduction (CR). Data relating to the treatment of these injuries in the elderly
between January 2007 and December 2015 were extracted using the
Humana and Medicare Advantage Databases. The primary outcome of
interest was the cost associated with treatment. Secondary analysis included
the cost of common complications. Statistical analysis was performed
using a non-parametric Aims
Materials and Methods
We performed a systematic review of the current literature regarding
the outcomes of unconstrained metacarpophalangeal joint (MCPJ) arthroplasty. We initially identified 1305 studies, and 406 were found to be
duplicates. After exclusion criteria were applied, seven studies
were included. Outcomes extracted included pre- and post-operative
pain visual analogue scores, range of movement (ROM), strength of
pinch and grip, satisfaction and patient reported outcome measures
(PROMs). Clinical and radiological complications were recorded.
The results are presented in three groups based on the design of
the arthroplasty and the aetiology (pyrocarbon-osteoarthritis (pyro-OA),
pyrocarbon-inflammatory arthritis (pyro-IA), metal-on-polyethylene
(MoP)).Aims
Materials and Methods
We conducted a study to determine whether radiological parameters
correlate with patient reported functional outcome, health-related
quality of life and physical measures of function in patients with
a fracture of the distal radius. The post-operative palmar tilt and ulnar variance at six weeks
and 12 months were correlated with the Patient Rated Wrist Evaluation,
Disabilities of the Arm, Shoulder and Hand, and EuroQol scores,
grip strength, pinch strength and range of movement at three, six
and 12 months for 50 patients (mean age 57 years; 26 to 85) having surgical
fixation, with either percutaneous pinning or reconstruction with
a volar plate, for a fracture of the distal radius.Aims
Patients and Methods
The aim of this study was to compare the Push Ortho Thumb Brace
CMC and a custom-made orthosis in the treatment of patients with
primary osteoarthritis of the carpometacarpal joint of the thumb.
Our outcome measures were pain scores, tests of hand function, patient
satisfaction and patient preference. A multicentre crossover randomised controlled trial was conducted
which included 63 patients (44 women) with primary osteoarthritis
of the carpometacarpal joint of the thumb. Of these, 59 patients
with a mean age of 60.1 years (standard deviation 8.2), completed
the study. Patients used both orthoses for two weeks with a two-week washout
period in-between. Pain was measured on a 10-cm visual analogue
scale. Hand function was assessed using the Jebsen Taylor Hand Function
test, Nine Hole Peg Test, key grip, pinch grip and Functional Index
for Hand Osteoarthritis. Patient preference was assessed using the
Dutch version of the Quebec User Evaluation of Satisfaction with
Assistive Technology score.Aims
Patients and Methods
Our purpose was to determine the quality of current randomised
controlled trials (RCTs) in hand surgery using standardised metrics. Based on five-year mean impact factors, we selected the six journals
that routinely publish studies of upper extremity surgery. Using
a journal-specific search query, 62 RCTs met our inclusion criteria.
Then three blinded reviewers used the Jadad and revised Coleman Methodology
Score (RCMS) to assess the quality of the manuscripts.Aims
Materials and Methods
We present an economic evaluation using data
from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare
the relative cost effectiveness of percutaneous Kirschner wire (K-wire)
fixation and volar locking-plate fixation for patients with dorsally-displaced
fractures of the distal radius. The cost effectiveness analysis (cost per quality-adjusted life
year; QALY) was derived from a multi-centre, two-arm, parallel group,
assessor-blind, randomised controlled trial which took place in
18 trauma centres in the United Kingdom. Data from 460 patients
were available for analysis, which includes both a National Health
Service cost perspective including costs of surgery, implants and
healthcare resource use over a 12-month period after surgery, and
a societal perspective, which includes the cost of time off work
and the need for additional private care. There was only a small difference in QALYs gained for patients
treated with locking-plate fixation over those treated with K-wires.
At a mean additional cost of £714 (95% confidence interval 588 to
865) per patient, locking-plate fixation presented an incremental
cost effectiveness ratio (ICER) of £89 322 per QALY within the first
12 months of treatment. Sensitivity analyses were undertaken to
assess the ICER of locking-plate fixation compared with K-wires.
These were greater than £30 000. Compared with locking-plate fixation, K-wire fixation is a ‘cost
saving’ intervention, with similar health benefits. Cite this article: