Redisplacement of unstable
Displaced fractures of the forearm in children are often treated conservatively, but there is a relatively high incidence of redisplacement, malunion and consequent limitation of function. We have performed percutaneous Kirschner (K) wire fixation in 72 such children under the age of 14 years, of which 57 were reviewed for our study. Both the radius and ulna were fractured in 45 (79%), the radius only in eight and the ulna only in four. The mean initial angulation was 19° in the lateral plane and 9° in the anteroposterior plane for the radius and 15° and 9°, respectively, for the ulna. In 42 patients (74%) we performed closed reduction. In the remaining 15 (26%) closed reduction failed and an open reduction, through a minimal approach, was required before K wiring. At a mean follow-up of 20 months all patients had good functional results with an excellent range of movement. Only five had angulation of from 10° to 15° and none had nonunion, premature epiphyseal closure or deep infection. Percutaneous intramedullary K wiring for
We identified 25 children (10 girls and 15 boys) who had been treated with single bone intramedullary fixation for diaphyseal fractures of both forearm bones. Their mean age was 10.75 years (4.6 to 15.9). All had a good functional outcome. We conclude that in selected children, single bone intramedullary nailing is a suitable method of treatment for diaphyseal fractures of both bones of the forearm.
Fractures of the proximal forearm in young children may be unstable with the elbow flexed but stable with it in extension. Fifteen such fractures were managed by immobilisation in long-arm casts with the elbow extended. Only one patient had more than 15 degrees angulation at the time of bony union. All obtained normal elbow movement at two weeks and full forearm rotation at follow-up. No casts fell off. The extended elbow cast is awkward but it provides an alternative to internal fixation for some unstable fractures.
Fractures of the forearm (radius or ulna or both)
in children have traditionally been immobilised in plaster of Paris (POP)
but synthetic cast materials are becoming more popular. There have
been no randomised studies comparing the efficacy of these two materials.
The aim of this study was to investigate which cast material is
superior for the management of these fractures. We undertook a single-centre
prospective randomised trial involving 199 patients with acute fractures
of the forearm requiring general anaesthesia for reduction. Patients
were randomised by sealed envelope into either a POP or synthetic
group and then underwent routine closed reduction and immobilisation
in a cast. The patients were reviewed at one and six weeks. A satisfaction
questionnaire was completed following the removal of the cast. All
clinical complications were recorded and the cast indices were calculated.
There was an increase in complications in the POP group. These complications
included soft areas of POP requiring revision and loss of reduction
with some requiring re-manipulation. There was an increased mean
padding index in the fractures that lost reduction. Synthetic casts
were preferred by the patients. This study indicates that the clinical outcomes and patient satisfaction
are superior using synthetic casts with no reduction in safety. Cite this article:
Aims. The aim of this study was to describe the incidence of refractures among children, following fractures of all long bones, and to identify when the risk of refracture decreases. Methods. All patients aged under 16 years with a fracture that had occurred in a bone with ongoing growth (open physis) from 1 May 2015 to 31 December 2020 were retrieved from the Swedish Fracture Register. A new fracture in the same segment within one year of the primary fracture was regarded as a refracture. Fracture localization, sex, lateral distribution, and time from primary fracture to refracture were analyzed for all long bones. Results. Of 40,090 primary fractures, 348 children (0.88%) sustained a refracture in the same long bone segment. The diaphyseal forearm was the long bone segment most commonly affected by refractures (n = 140; 3.4%). The median time to refracture was 147 days (interquartile range 82 to 253) in all segments of the long bones combined. The majority of the refractures occurred in boys (n = 236; 67%), and the left side was the most common side to refracture (n = 220; 62%). The data in this study suggest that the risk of refracture decreases after 180 days in the diaphyseal forearm, after 90 days in the distal forearm, and after 135 days in the diaphyseal tibia. Conclusion. Refractures in children are rare. However, different fractured segments run a different threat of refracture, with the highest risk associated with diaphyseal
Aims. This exploratory randomized controlled trial (RCT) aimed to determine the splint-related outcomes when using the novel biodegradable wood-composite splint (Woodcast) compared to standard synthetic fibreglass (Dynacast) for the immobilization of undisplaced upper limb fractures in children. Methods. An exploratory RCT was performed at a tertiary paediatric referral hospital between 1 June 2018 and 30 September 2019. The intention-to-treat population consisted of 170 patients (mean age 8.42 years (SD 3.42); Woodcast (WCG), n = 84, 57 male (67.9%); Dynacast (DNG), n = 86, 58 male (67.4%)). Patients with undisplaced upper limb fractures were randomly assigned to WCG or DNG treatment groups. Primary outcome was the stress stability of the splint material, defined as absence of any deformations or fractures within the splint during study period. Secondary outcomes included patient satisfaction and medical staff opinion. Additionally, biomechanical and chemical analysis of the splint samples was carried out. Results. Of the initial 170 patients, 168 (98.8%) completed at least one follow-up, and were included for analysis of the primary endpoint. Both treatment groups were well-matched regarding to age, sex, and type and localization of the fracture. Splint breakage occurred in three patients (3.6%; 95% confidence interval (CI), 0.007% to 0.102%) in the WCG and in three children (3.5%, 95% CI 0.007% to 0.09%) in the DNG (p > 0.99). The incidence of splint-related adverse events did not differ between the WCG (n = 21; 25.0%) and DNG (n = 24; 27.9%; p = 0.720). Under experimental conditions, the maximal tensile strength of Dynacast samples was higher than those deriving from Woodcast (mean 15.37 N/mm² (SD 1.37) vs 10.75 N/mm² (SD 1.20); p = 0.002). Chemical analysis revealed detection of polyisocyanate-prepolymer in Dynacast and polyester in Woodcast samples. Conclusion. Splint-related adverse events appear similar between WCG and DNG treatment groups during the treatment of undisplaced
The aim of this trial was to assess the cost-effectiveness of a soft bandage and immediate discharge, compared with rigid immobilization, in children aged four to 15 years with a torus fracture of the distal radius. A within-trial economic evaluation was conducted from the UK NHS and personal social services (PSS) perspective, as well as a broader societal point of view. Health resources and quality of life (the youth version of the EuroQol five-dimension questionnaire (EQ-5D-Y)) data were collected, as part of the Forearm Recovery in Children Evaluation (FORCE) multicentre randomized controlled trial over a six-week period, using trial case report forms and patient-completed questionnaires. Costs and health gains (quality-adjusted life years (QALYs)) were estimated for the two trial treatment groups. Regression was used to estimate the probability of the new treatment being cost-effective at a range of ‘willingness-to-pay’ thresholds, which reflect a range of costs per QALY at which governments are typically prepared to reimburse for treatment.Aims
Methods
The aim of this study was to assess whether it is possible to predict the mortality, and the extent and time of neurological recovery from the time of the onset of symptoms and MRI grade, in patients with the cerebral fat embolism syndrome (CFES). This has not previously been investigated. The study included 34 patients who were diagnosed with CFES following trauma between 2012 and 2018. The clinical diagnosis was confirmed and the severity graded by MRI. We investigated the rate of mortality, the time and extent of neurological recovery, the time between the injury and the onset of symptoms, the clinical severity of the condition, and the MRI grade. All patients were male with a mean age of 29.7 years (18 to 70). The mean follow-up was 4.15 years (2 to 8), with neurological recovery being assessed by the Glasgow Outcome Scale and the Mini-Mental State Examination.Aims
Methods
The aim of this study was to assess and compare active rotation of the forearm in normal subjects after the application of a short-arm cast (SAC) in the semisupination position and a long-arm cast (LAC) in the neutral position. A clinical study was also conducted to compare the functional outcomes of using a SAC in the semisupination position with those of using a LAC in the neutral position in patients who underwent arthroscopic triangular fibrocartilage complex (TFCC) foveal repair. A total of 40 healthy right-handed volunteers were recruited. Active pronation and supination of the forearm were measured in each subject using a goniometer. In the retrospective clinical study, 40 patients who underwent arthroscopic foveal repair were included. The wrist was immobilized postoperatively using a SAC in the semisupination position (approximately 45°) in 16 patients and a LAC in 24. Clinical outcomes were assessed using grip strength and patient-reported outcomes. The degree of disability caused by cast immobilization was also evaluated when the cast was removed.Aims
Methods
A study of 79 children with malunion of
We compared the mechanical properties of carbon fibre composite bone plates with those of stainless steel and titanium. The composite plates have less stiffness with good fatigue properties. Tissue culture and small animal implantation confirmed the biocompatibility of the material. We also present a preliminary report on the use of the carbon fibre composite plates in 40
We treated 22 children with a supracondylar fracture of the humerus and an ipsilateral fracture of the forearm by closed reduction and percutaneous fixation. There were four Gartland type-II and 18 Gartland type-III supracondylar fractures of the humerus. There were fractures of both bones of the forearm in 16 and of the radius in six. Both the supracondylar and the distal
1. A simple method of internal fixation of adult
We describe the results of treatment of open fractures of the humerus, radius and ulna in 61 children. Most were due to low-energy trauma and were rarely associated with head or other injuries; 72% were Gustilo type I, 15% type II and 13% type III. Fifteen children (25%) had open diaphyseal, supracondylar or T-shaped fractures of the humerus. Arterial injuries occurred in two (13%) and nerve injuries in 7 (47%). All nerve injuries recovered spontaneously. The long-term results in 13 children were excellent or good in 11 (85%) and fair in two (15%). Forty-six children (75%) had open
Most fractures of the radial head are stable
undisplaced or minimally displaced partial fractures without an associated
fracture of the elbow or forearm or ligament injury, where stiffness
following non-operative management is the primary concern. Displaced
unstable fractures of the radial head are usually associated with other
fractures or ligament injuries, and restoration of radiocapitellar
contact by reconstruction or prosthetic replacement of the fractured
head is necessary to prevent subluxation or dislocation of the elbow
and
The aim of this study was to analyze the results of two radiocapitellar prostheses in a large case series followed prospectively, with medium-term follow-up. A total of 31 patients with a mean age of 54 years (27 to 73) were analyzed; nine had primary osteoarthritis (OA) and 17 had post-traumatic OA, three had capitellar osteonecrosis, and two had a fracture. Overall, 17 Lateral Resurfacing Elbow (LRE) and 14 Uni-Elbow Radio-Capitellum Implant (UNI-E) arthroplasties were performed. Pre- and postoperative assessment involved the Mayo Elbow Performance Score (MEPS), the Quick Disabilities of the Arm, Shoulder and Hand (Q-DASH) score, and the modified American Shoulder Elbow Surgeons (m-ASES) score.Aims
Patients and Methods
We set out to determine if there is a difference in perioperative outcomes between early and delayed surgery in paediatric supracondylar humeral fractures in the absence of vascular compromise through a systematic review and meta-analysis. A literature search was performed, with search outputs screened for studies meeting the inclusion criteria. The groups of early surgery (ES) and delayed surgery (DS) were classified by study authors. The primary outcome measure was open reduction requirement. Meta-analysis was performed in the presence of sufficient study homogeneity. Individual study risk of bias was assessed using the Risk of Bias in Non-Randomised Studies – of Interventions (ROBINS-I) criteria, with the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) criteria used to evaluate outcomes independently.Aims
Materials and Methods