Advertisement for orthosearch.org.uk
Results 1 - 20 of 23
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 271 - 278
1 Feb 2021
Chang JS Ravi B Jenkinson RJ Paterson JM Huang A Pincus D

Aims. Echocardiography is commonly used in hip fracture patients to evaluate perioperative cardiac risk. However, echocardiography that delays surgical repair may be harmful. The objective of this study was to compare surgical wait times, mortality, length of stay (LOS), and healthcare costs for similar hip fracture patients evaluated with and without preoperative echocardiograms. Methods. A population-based, matched cohort study of all hip fracture patients (aged over 45 years) in Ontario, Canada between 2009 and 2014 was conducted. The primary exposure was preoperative echocardiography (occurring between hospital admission and surgery). Mortality rates, surgical wait times, postoperative LOS, and medical costs (expressed as 2013$ CAN) up to one year postoperatively were assessed after propensity-score matching. Results. A total of 2,354 of 42,230 (5.6%) eligible hip fracture patients received a preoperative echocardiogram during the study period. Echocardiography ordering practices varied among hospitals, ranging from 0% to 23.0% of hip fracture patients at different hospital sites. After successfully matching 2,298 (97.6%) patients, echocardiography was associated with significantly increased risks of mortality at 90 days (20.1% vs 16.8%; p = 0.004) and one year (32.9% vs 27.8%; p < 0.001), but not at 30 days (11.4% vs 9.8%; p = 0.084). Patients with echocardiography also had a mean increased delay from presentation to surgery (68.80 hours (SD 44.23) vs 39.69 hours (SD 27.09); p < 0.001), total LOS (19.49 days (SD 25.39) vs 15.94 days (SD 22.48); p < 0.001), and total healthcare costs at one year ($51,714.69 (SD 54,675.28) vs $41,861.47 (SD 50,854.12); p < 0.001). Conclusion. Preoperative echocardiography for hip fracture patients is associated with increased postoperative mortality at 90 days and one year but not at 30 days. Preoperative echocardiography is also associated with increased surgical delay, postoperative LOS, and total healthcare costs at one year. Echocardiography should be considered an urgent test when ordered to prevent additional surgical delay. Cite this article: Bone Joint J 2021;103-B(2):271–278


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 51 - 58
1 Mar 2024
Jenkinson MRJ Meek DRM Tate R Brady A MacMillan S Grant H Currie S

Aims. Elevated blood cobalt levels secondary to metal-on-metal (MoM) hip arthroplasties are a suggested risk factor for developing cardiovascular complications including cardiomyopathy. Clinical studies assessing patients with MoM hips using left ventricular ejection fraction (LVEF) have found conflicting evidence of cobalt-induced cardiomyopathy. Global longitudinal strain (GLS) is an echocardiography measurement known to be more sensitive than LVEF when diagnosing early cardiomyopathies. The extent of cardiovascular injury, as measured by GLS, in patients with elevated blood cobalt levels has not previously been examined. Methods. A total of 16 patients with documented blood cobalt ion levels above 13 µg/l (13 ppb, 221 nmol/l) were identified from a regional arthroplasty database. They were matched with eight patients awaiting hip arthroplasty. All patients underwent echocardiography, including GLS, investigating potential signs of cardiomyopathy. Results. Patients with MoM hip arthroplasties had a mean blood cobalt level of 29 µg/l (495 nmol/l) compared to 0.01 µg/l (0.2 nmol/l) in the control group. GLS readings were available for seven of the MoM cohort, and were significantly lower when compared with controls (-15.5% vs -18% (MoM vs control); p = 0.025)). Pearson correlation demonstrated that GLS significantly correlated with blood cobalt level (r = 0.8521; p < 0.001). However, there were no differences or correlations for other echocardiography measurements, including LVEF (64.3% vs 63.7% (MoM vs control); p = 0.845). Conclusion. This study supports the hypothesis that patients with elevated blood cobalt levels above 13 µg/l in the presence of a MoM hip implant may have impaired cardiac function compared to a control group of patients awaiting hip arthroplasty. It is the first study to use the more sensitive parameter of GLS to assess for any cardiac contractile dysfunction in patients with a MoM hip implant and a normal LVEF. Larger studies should be performed to determine the potential of GLS as a predictor of cardiac complications in patients with MoM arthroplasties. Cite this article: Bone Joint J 2024;106-B(3 Supple A):51–58


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 450 - 455
1 May 1995
Christie J Robinson C Pell A McBirnie J Burnett R

We performed transoesophageal echocardiography in 111 operations (110 patients) which included medullary reaming for fresh fractures of the femur and tibia, pathological lesions of the femur, and hemiarthroplasty of the hip. Embolic events of varying intensity were seen in 97 procedures and measured pulmonary responses correlated with the severity of embolic phenomena. Twenty-four out of the 25 severe embolic responses occurred while reaming pathological lesions or during cemented hemiarthroplasty of the hip and, overall, pathological lesions produced the most severe responses. Paradoxical embolisation occurred in four patients, all with pathological lesions of the femur (21%); two died. In 12 patients large coagulative masses became trapped in the heart. Extensive pulmonary thromboembolism with reamed bone and immature clot was found at post-mortem in two patients; there was severe systemic embolisation of fat and marrow in one who had a patent foramen ovale and widespread mild systemic fat embolisation in the other without associated foraminal defect. Sequential analysis of blood from the right atrium in five patients showed considerable activation of clotting cascades during reaming


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 409 - 412
1 May 1994
Christie J Burnett R Potts H Pell A

We performed transoesophageal echocardiography on 20 patients with femoral neck fractures randomly treated with an uncemented Austin-Moore or cemented Hastings hemiarthroplasty. Cemented arthroplasty caused greater and more prolonged embolic cascades than did uncemented arthroplasty. Some emboli were more than 3 cm in length. In some patients the cascades were associated with pulmonary hypertension, diminished oxygen tension and saturation, and the presence of fat and marrow in aspirates from the right atrium


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 921 - 925
1 Nov 1993
Pell A Christie J Keating J Sutherland G

We performed transoesophageal echocardiography on 24 patients during reamed intramedullary nailing of 17 tibial and seven femoral fractures. In 14 patients there was only minimal evidence of emboli passing through the heart, but in six copious showers of small emboli (< 10 mm maximum dimension) were observed. In four other patients, there were also multiple large emboli (> 10 mm maximum dimension). Three of these patients developed fat embolism syndrome postoperatively and one died. Earlier nailing was associated with smaller quantities of emboli


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 854 - 855
1 Sep 1996
ABRAHAM P MILLOT JR PIDHORZ L SAUMET JL


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 481 - 485
1 Apr 2007
Church JS Scadden JE Gupta RR Cokis C Williams KA Janes GC

Systemic emboli released during total knee replacement have been implicated as a cause of peri-operative morbidity and neurological dysfunction. We undertook a prospective, double-blind, randomised study to compare the cardiac embolic load sustained during computer-assisted and conventional, intramedullary-aligned, total knee replacement, as measured by transoesophageal echocardiography. There were 26 consecutive procedures performed by a single surgeon at a single hospital. The embolic load was scored using the modified Mayo grading system for echogenic emboli. Fourteen patients undergoing computer-assisted total knee replacement had a mean embolic score of 4.89 (3 to 7) and 12 undergoing conventional total knee replacement had a mean embolic score of 6.15 (4 to 8) on release of the tourniquet. Comparison of the groups using a two-tailed t-test confirmed a highly significant difference (p = 0.004). This study demonstrates that computer-assisted knee replacement results in the release of significantly fewer systemic emboli than the conventional procedure using intramedullary alignment


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 696 - 702
1 Jun 2022
Kvarda P Puelacher C Clauss M Kuehl R Gerhard H Mueller C Morgenstern M

Aims

Periprosthetic joint infections (PJIs) and fracture-related infections (FRIs) are associated with a significant risk of adverse events. However, there is a paucity of data on cardiac complications following revision surgery for PJI and FRI and how they impact overall mortality. Therefore, this study aimed to investigate the risk of perioperative myocardial injury (PMI) and mortality in this patient cohort.

Methods

We prospectively included consecutive patients at high cardiovascular risk (defined as age ≥ 45 years with pre-existing coronary, peripheral, or cerebrovascular artery disease, or any patient aged ≥ 65 years, plus a postoperative hospital stay of > 24 hours) undergoing septic or aseptic major orthopaedic surgery between July 2014 and October 2016. All patients received a systematic screening to reliably detect PMI, using serial measurements of high-sensitivity cardiac troponin T. All-cause mortality was assessed at one year. Multivariable logistic regression models were applied to compare incidence of PMI and mortality between patients undergoing septic revision surgery for PJI or FRI, and patients receiving aseptic major bone and joint surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 90 - 94
1 Jan 2003
Takahashi S Kitagawa H Ishii T

Intraoperative pulmonary fat and bone-marrow embolism is a serious complication of bone and joint surgery. We have investigated the occurrence and incidence of intraoperative embolism in patients undergoing elective lumbar spinal surgery with or without instrumentation. Sixty adult patients with lumbar degenerative disease were examined by intraoperative transoesophageal echocardiography while undergoing posterior lumbar surgery. Of these, 40 underwent surgery with instrumentation and 20 without. Moderate to severe (grade 2 or 3 according to the grading scale of Pitto et al) embolic events were seen in 80% of the instrumented patients but in none of the non-instrumented patients (p < 0.001). The insertion of pedicle screws was particularly associated with large numbers of pulmonary emboli, while the surgical approach, laminectomy, disc removal and bone harvesting were associated with small numbers of emboli. We consider that, as in arthroplasty and intramedullary fixation of fractures, these embolic events are relevant to the development of potentially fatal fat embolism during spinal surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 456 - 459
1 May 1995
Christie J Robinson C Singer B Ray D

We randomised 24 patients before they had a cemented hemiarthroplasty for hip fracture to receive either thorough or minimal saline lavage of the femoral canal. We then determined the effect in each group on the thromboembolic and cardiopulmonary responses to the pressurised insertion of cement, using transoesophageal echocardiography to show the echogenic embolic response. We found a statistically significant reduction in both the duration of the response and the number of large emboli in patients who had had thorough lavage as compared with the control group with minimal lavage. There was also less disturbance of pulmonary function, as assessed by the change in end-tidal CO2 levels and oxygen saturation, in patients who had thorough lavage. Three patients had a significant fall in blood pressure during cement insertion; all had only minimal lavage. We consider that thorough lavage should be an essential part of the preparation of the proximal femur before cement insertion


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 963 - 973
1 Sep 2001
Robinson CM Ludlam CA Ray DC Swann DG Christie J

We measured the changes during operation in seven markers of coagulation in a prospective series of 84 patients with fractures of the tibia or femur who were undergoing reamed intramedullary nailing. All patients were also continually monitored using transoesophageal echocardiography to assess marrow embolism. In a subset of 40 patients, intraoperative cardiopulmonary function was monitored, using pulmonary and systemic arterial catheterisation. The procedure produced a significant increase in prothrombin time, activated partial thromboplastin time, the level of prothrombin fragments F. 1+2. and D-dimers, and a decrease in the fibrinogen level, suggesting activation of both the coagulation and fibrinolytic pathways. There was evidence of both platelet hyper-reactivity and depletion, as estimated by an increase in β-thromboglobulin levels and a decrease in the platelet count. In the patients who had invasive monitoring there was an incremental increase in mean pulmonary arterial pressure, with the changes being greatest during insertion of the guide-wire and reaming. The change in markers of coagulation, pulmonary artery pressure and arterial oxygen partial pressures correlated with the intraoperative embolic response. Greater changes in these parameters were observed during stabilisation of pathological fractures and in those patients in whom surgery had been delayed for more than 48 hours. Seven patients with pathological fractures developed more severe hypoxic episodes during reaming, which were associated with significantly greater arterial hypoxaemia, a fall in the right ventricular ejection fraction and an increase in the mean pulmonary artery pressure, pulmonary capillary wedge pressure, central venous pressure and the pulmonary vascular resistance index. These changes suggested that the patients had transient intraoperative right heart strain. Eight patients developed significant postoperative respiratory compromise. They all had severe intraoperative embolic responses and, in the three who had invasive monitoring, there was a significantly greater increase in pulmonary artery pressure and alveolar-arterial oxygen gradient, and a fall in the ratio of arterial partial pressure of oxygen to the inspired oxygen concentration. Operative delay, intraoperative paradoxical embolisation and the scores for the severity of the coagulative and embolic responses were predictive of the development of postoperative respiratory complications on univariate logistic regression analysis. On multivariate analysis, however, only the embolic and coagulative scores were significant independent predictors of respiratory complications


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 205 - 206
1 Feb 2021
Haddad FS


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 540 - 546
1 May 2019
Juneau D Grammatopoulos G Alzahrani A Thornhill R Inacio JR Dick A Vogel KI Dobransky J Beaulé PE Dwivedi G

Aims

Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied.

Patients and Methods

In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1129 - 1137
1 Sep 2019
Leer-Salvesen S Engesæter LB Dybvik E Furnes O Kristensen TB Gjertsen J

Aims

The aim of this study was to investigate mortality and risk of intraoperative medical complications depending on delay to hip fracture surgery by using data from the Norwegian Hip Fracture Register (NHFR) and the Norwegian Patient Registry (NPR).

Patients and Methods

A total of 83 727 hip fractures were reported to the NHFR between 2008 and 2017. Pathological fractures, unspecified type of fractures or treatment, patients less than 50 years of age, unknown delay to surgery, and delays to surgery of greater than four days were excluded. We studied total delay (fracture to surgery, n = 38 754) and hospital delay (admission to surgery, n = 73 557). Cox regression analyses were performed to calculate relative risks (RRs) adjusted for sex, age, American Society of Anesthesiologists (ASA) classification, type of surgery, and type of fracture. Odds ratio (OR) was calculated for intraoperative medical complications. We compared delays of 12 hours or less, 13 to 24 hours, 25 to 36 hours, 37 to 48 hours, and more than 48 hours.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1405 - 1410
1 Oct 2015
Fu J Song K Zhang YG Zheng GQ Zhang GY Liu C Wang Y

Cardiac disease in patients with ankylosing spondylitis (AS) has previously been studied but not in patients with a kyphosis or in those who have undergone an operation to correct it.

The aim of this study was to measure the post-operative changes in cardiac function of patients with an AS kyphosis after pedicle subtraction osteotomy (PSO).

The original cohort consisted of 39 patients (33 men, six women). Of these, four patients (two men, two women) were lost to follow-up leaving 35 patients (31 men, four women) to study. The mean age of the remaining patients was 37.4 years (22.3 to 47.8) and their mean duration of AS was 17.0 years (4.6 to 26.4). Echocardiographic measurements, resting heart rate (RHR), physical function score (PFS), and full-length standing spinal radiographs were obtained before surgery and at the two-year follow-up.

The mean pre-operative RHR was 80.2 bpm (60.6 to 112.3) which dropped to a mean of 73.7 bpm (60.7 to 90.6) at the two-year follow-up (p = 0.0000). Of 15 patients with normal ventricular function pre-operatively, two developed mild left ventricular diastolic dysfunction (LVDD) at the two-year follow-up. Of 20 patients with mild LVDD pre-operatively only five had this post-operatively. Overall, 15 patients had normal LV diastolic function before their operation and 28 patients had normal LV function at the two-year follow-up.

The clinical improvement was 15 out of 20 (75.0%): cardiac function in patients with AS whose kyphosis was treated by PSO was significantly improved.

Cite this article: Bone Joint J 2015;97-B:1405–10.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 536 - 539
1 Apr 2009
Edmundson SP Hirpara KM Ryan RS O’Malley T O’Grady P

We report a 30-year-old patient who was involved in a high-velocity road traffic accident and developed a left-sided hemiparesis, which was noted in the post-operative period following bilateral femoral intramedullary nailing. CT scanning of the brain revealed infarcts in the right frontal and parietal lobes in the distribution of the right middle cerebral artery. CT angiography showed occlusion of the right internal carotid artery consistent with internal carotid artery dissection. He was anticoagulated and nine months later was able to walk independently.

An awareness of this injury is needed to diagnose blunt trauma to the internal carotid artery. Even in the absence of obvious neck trauma, carotid artery dissection should be suspected in patients with a neurological deficit in the peri-operative period.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 77 - 79
1 Jan 2007
Von Meibom N Gilson N Dhapre A Davis B

We undertook a simultaneous prospective two-centre study to examine why patients with fractures of the proximal femur experience a delay in undergoing surgery.

At centre 1, 23 of 105 patients (22%) suffered an avoidable delay, 18 (78%) because of a lack of theatre capacity while at centre 2, 71 of 130 patients (55%) had an avoidable delay, with 54 (76%) because of this cause. Miscellaneous reasons such as poor ward management, co-existing medical conditions, and lack of equipment were responsible for the remainder of the delays.

Without a substantial increase in operating capacity for acute trauma, it will not be possible to comply with guidelines which recommend surgical treatment within 24 hours in elderly and vulnerable patients.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 94 - 99
1 Jan 2014
Evans S Ramasamy A Marks DS Spilsbury J Miller P Tatman A Gardner AC

The management of spinal deformity in children with univentricular cardiac pathology poses significant challenges to the surgical and anaesthetic teams. To date, only posterior instrumented fusion techniques have been used in these children and these are associated with a high rate of complications. We reviewed our experience of both growing rod instrumentation and posterior instrumented fusion in children with a univentricular circulation.

Six children underwent spinal corrective surgery, two with cavopulmonary shunts and four following completion of a Fontan procedure. Three underwent growing rod instrumentation, two had a posterior fusion and one had spinal growth arrest. There were no complications following surgery, and the children undergoing growing rod instrumentation were successfully lengthened. We noted a trend for greater blood loss and haemodynamic instability in those whose surgery was undertaken following completion of a Fontan procedure. At a median follow-up of 87.6 months (interquartile range (IQR) 62.9 to 96.5) the median correction of deformity was 24.2% (64.5° (IQR 46° to 80°) vs 50.5° (IQR 36° to 63°)).

We believe that early surgical intervention with growing rod instrumentation systems allows staged correction of the spinal deformity and reduces the haemodynamic insult to these physiologically compromised children. Due to the haemodynamic changes that occur with the completed Fontan circulation, the initial scoliosis surgery should ideally be undertaken when in the cavopulmonary shunt stage.

Cite this article: Bone Joint J 2014;96-B:94–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 570 - 573
1 Apr 2012
Whittingham-Jones P Mann B Coward P Hart AJ Skinner JA

Fracture of a ceramic component in total hip replacement is a rare but potentially catastrophic complication. The incidence is likely to increase as the use of ceramics becomes more widespread. We describe such a case, which illustrates how inadequate initial management will lead to further morbidity and require additional surgery. We present the case as a warning that fracture of a ceramic component should be revised to another ceramic-on-ceramic articulation in order to minimise the risk of further catastrophic wear.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 31 - 37
1 Jan 2013
Zywiel MG Brandt J Overgaard CB Cheung AC Turgeon TR Syed KA

Symptomatic cobalt toxicity from a failed total hip replacement is a rare but devastating complication. It has been reported following revision of fractured ceramic components, as well as in patients with failed metal-on-metal articulations. Potential clinical findings include fatigue, weakness, hypothyroidism, cardiomyopathy, polycythaemia, visual and hearing impairment, cognitive dysfunction, and neuropathy. We report a case of an otherwise healthy 46-year-old patient, who developed progressively worsening symptoms of cobalt toxicity beginning approximately six months following synovectomy and revision of a fractured ceramic-on-ceramic total hip replacement to a metal-on-polyethylene bearing. The whole blood cobalt levels peaked at 6521 µg/l. The patient died from cobalt-induced cardiomyopathy. Implant retrieval analysis confirmed a loss of 28.3 g mass of the cobalt–chromium femoral head as a result of severe abrasive wear by ceramic particles embedded in the revision polyethylene liner. Autopsy findings were consistent with heavy metal-induced cardiomyopathy.

We recommend using new ceramics at revision to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components.

Cite this article: Bone Joint J 2013;95-B:31–7.