Advertisement for orthosearch.org.uk
Results 1 - 20 of 183
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 29 - 34
1 Jan 2023
Fransen BL Bengoa FJ Neufeld ME Sheridan GA Garbuz DS Howard LC

Aims. Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up. Methods. We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear. Results. Overall survival rate for all-cause revision was 94.5% (95% confidence interval (CI) 81.7% to 97.2%) at a mean follow-up of 12.8 years (10.9 to 18.7). Three patients were revised, none for liner wear, fracture, or dissociation. A total of 22 patients were included in the radiological analysis (mean follow-up 9.9 years (7.5 to 13.7)). Mean linear liner wear was 0.085 mm (95% CI -0.086 to 0.257) and the volumetric wear rate was 11.097 mm. 3. /year (95% CI -6.5 to 28.7). Conclusion. Using HXLPE liners with 36 mm heads in 52 mm acetabular components or smaller is safe, with excellent survival and low rates of linear and volumetric wear at medium-term follow-up. Patients did not require revision surgery for liner complications such as fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads outweigh the potential risks of using thin HXLPE liners. Cite this article: Bone Joint J 2023;105-B(1):29–34


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 301 - 306
1 Mar 2023
Jennison T Ukoumunne O Lamb S Sharpe I Goldberg AJ

Aims. Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. Methods. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018. Results. Overall, 5,562 primary ankle arthroplasties were recorded in the NJR. Linked data show a one-year survivorship of 98.8% (95% confidence interval (CI) 98.4% to 99.0%), five-year survival in 2,725 patients of 90.2% (95% CI 89.2% to 91.1%), and ten-year survival in 199 patients of 86.2% (95% CI 84.6% to 87.6%). The five-year survival for fixed-bearing implants was 94.3% (95% CI 91.3% to 96.3%) compared to 89.4% (95% CI 88.3% to 90.4%) for mobile-bearing implants. A Cox regression model for all implants with over 100 implantations using the implant with the best survivorship (Infinity) as the reference, only the STAR (hazard ratio (HR) 1.60 (95% CI 0.87 to 2.96)) and INBONE (HR 0.38 (95% CI 0.05 to 2.84)) did not demonstrate worse survival at three and five years. Conclusion. Ankle arthroplasties in the UK have a five-year survival rate of 90.2%, which is lower than recorded on the NJR, because we have shown that approximately one-third of ankle arthroplasty failures are not reported to the NJR. There are statistically significant differences in survival between different implants. Fixed-bearing implants appear to demonstrate higher survivorship than mobile-bearing implants. Cite this article: Bone Joint J 2023;105-B(3):301–306


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1571 - 1577
1 Oct 2021
Schelde AB Petersen J Jensen TB Gromov K Overgaard S Olesen JB Jimenez-Solem E

Aims. The aim of this study is to compare the effectiveness and safety of thromboprophylactic treatments in patients undergoing primary total knee arthroplasty (TKA). Methods. Using nationwide medical registries, we identified patients with a primary TKA performed in Denmark between 1 January 2013 and 31 December 2018 who received thromboprophylactic treatment. We examined the 90-day risk of venous thromboembolism (VTE), major bleeding, and all-cause mortality following surgery. We used a Cox regression model to compute hazard ratios (HRs) with 95% confidence intervals (CIs) for each outcome, pairwise comparing treatment with dalteparin or dabigatran with rivaroxaban as the reference. The HRs were both computed using a multivariable and a propensity score matched analysis. Results. We identified 27,736 primary TKA patients who received thromboprophylactic treatment (rivaroxaban (n = 18,846); dalteparin (n = 5,767); dabigatran (n = 1,443); tinzaparin (n = 1,372); and enoxaparin (n = 308)). In the adjusted multivariable analysis and compared with rivaroxaban, treatment with dalteparin (HR 0.68 (95% CI 0.49 to 0.92)) or dabigatran (HR 0.31 (95% CI 0.13 to 0.70)) was associated with a decreased risk of VTE. No statistically significant differences were observed for major bleeding or all-cause mortality. The propensity score matched analysis yielded similar results. Conclusion. Treatment with dalteparin or dabigatran was associated with a decreased 90-day risk of VTE following primary TKA surgery compared with treatment with rivaroxaban. Cite this article: Bone Joint J 2021;103-B(10):1571–1577


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1184 - 1188
1 Nov 2023
Jennison T Ukoumunne OC Lamb S Goldberg AJ Sharpe I

Aims. The number of revision total ankle arthroplasties (TAAs) which are undertaken is increasing. Few studies have reported the survival after this procedure. The primary aim of this study was to analyze the survival of revision ankle arthroplasties using large datasets. Secondary aims were to summarize the demographics of the patients, the indications for revision TAA, further operations, and predictors of survival. Methods. The study combined data from the National Joint Registry and NHS Digital to report the survival of revision TAA. We have previously reported the failure rates and risk factors for failure after TAA, and the outcome of fusion after a failed TAA, using the same methodology. Survival was assessed using life tables and Kaplan Meier graphs. Cox proportional hazards regression models were fitted to compare failure rates. Results. A total of 228 patients underwent revision TAA. The mean follow-up was 2.6 years (SD 2.0). The mean time between the initial procedure and revision was 2.3 years (SD 1.8). The most commonly used implant was the Inbone which was used in 81 patients. A total of 29 (12.7%) failed; nine (3.9%) patients underwent a further revision, 19 (8.3%) underwent a fusion, and one (0.4%) had an amputation. The rate of survival was 95.4% (95% confidence interval (CI) 91.6 to 97.5) at one year, 87.7% (95% CI 81.9 to 91.7; n = 124) at three years and 77.5% (95% CI 66.9 to 85.0; n = 57) at five years. Revision-specific implants had a better survival than when primary implants were used at revision. A total of 50 patients (21.9%) had further surgery; 19 (8.3%) underwent reoperation in the first 12 months. Cox regression models were prepared. In crude analysis the only significant risk factors for failure were the use of cement (hazard ratio (HR) 3.02 (95% CI 1.13 to 8.09)) and the time since the primary procedure (HR 0.67 (95% CI 0.47 to 0.97)). No risk factors for failure were identified in multivariable Cox regression modelling. Conclusion. Revision TAAs have good medium term survival and low rates of further surgery. New modular revision implants appear to have improved the survival compared with the use of traditional primary implants at revision. Cite this article: Bone Joint J 2023;105-B(11):1184–1188


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 775 - 782
1 Jul 2023
Koper MC Spek RWA Reijman M van Es EM Baart SJ Verhaar JAN Bos PK

Aims. The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate. Methods. A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model. Results. We found that an increase of one part per billion (ppb) in serum Co and Cr levels correlated significantly with worsening of the HHS in the following year. This significant correlation was also true for the HOOS-Pain and HOOS-quality of life sub scores. The overall ten-year survival rate in our cohort was 65% (95% confidence interval (CI) 52.5 to 77.6). Cox regression analysis showed a significant hazard ratio (HR) of 1.08 (95% CI 1.01 to 1.15; p = 0.028) for serum Co level. No significance was found with sex or inclination angle. Conclusion. This study shows that increasing serum Co and Cr levels measured in patients with an ASR-HRA are predictive for deterioration in HHS and HOOS subscales in the following year. Increasing serum Co and Cr should forewarn both surgeon and patient that there is a heightened risk of failure. Continued and regular review of patients with an ASR-HRA implant by measurement of serum Co/Cr levels and PROMs remains essential. Cite this article: Bone Joint J 2023;105-B(7):775–782


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 603 - 612
1 Jun 2024
Ahmad A Egeland EH Dybvik EH Gjertsen J Lie SA Fenstad AM Matre K Furnes O

Aims. This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days. Methods. We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH). Results. In unadjusted analyses, there was no significant difference between IMN and SHS patient survival at 30 days (91.8% vs 91.1%; p = 0.083) or 90 days (85.4% vs 84.5%; p = 0.065), but higher one-year survival for IMNs (74.5% vs 73.3%; p = 0.031) compared with SHSs. After adjustments, no significant difference in 30-day mortality was found (hazard rate ratio (HRR) 0.94 (95% confidence interval (CI) 0.86 to 1.02(; p = 0.146). IMNs exhibited higher mortality at 0 to 1 days (HRR 1.63 (95% CI 1.13 to 2.34); p = 0.009) compared with SHSs, with a NNH of 556, but lower mortality at 8 to 30 days (HRR 0.89 (95% CI 0.80 to 1.00); p = 0.043). No differences were observed in mortality at 2 to 7 days (HRR 0.94 (95% CI 0.79 to 1.11); p = 0.434), 90 days (HRR 0.95 (95% CI 0.89 to 1.02); p = 0.177), or 365 days (HRR 0.97 (95% CI 0.92 to 1.02); p = 0.192). Conclusion. This study found no difference in 30-day mortality between IMNs and SHSs. However, IMNs were associated with a higher mortality at 0 to 1 days and a marginally lower mortality at 8 to 30 days compared with SHSs. The observed differences in mortality were small and should probably not guide choice of treatment. Cite this article: Bone Joint J 2024;106-B(6):603–612


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 977 - 984
1 Sep 2023
Kamp T Gademan MGJ van Zon SKR Nelissen RGHH Vliet Vlieland TPM Stevens M Brouwer S

Aims. For the increasing number of working-age patients undergoing total hip or total knee arthroplasty (THA/TKA), return to work (RTW) after surgery is crucial. We investigated the association between occupational class and time to RTW after THA or TKA. Methods. Data from the prospective multicentre Longitudinal Leiden Orthopaedics Outcomes of Osteoarthritis Study were used. Questionnaires were completed preoperatively and six and 12 months postoperatively. Time to RTW was defined as days from surgery until RTW (full or partial). Occupational class was preoperatively assessed and categorized into four categories according to the International Standard Classification of Occupations 2008 (blue-/white-collar, high-/low-skilled). Cox regression analyses were conducted separately for THA and TKA patients. Low-skilled blue-collar work was used as the reference category. Results. A total of 360 THA and 276 TKA patients, preoperatively employed, were included. Patients were mainly high-skilled (THA 57%; TKA 41%) or low-skilled (THA 24%; TKA 38%) white-collar workers. Six months post-THA, RTW rates were 78% of low-skilled blue-collar workers compared to 83% to 86% within other occupational classes, increasing after 12 months to 87% to 90% in all occupational classes. Six months post-TKA, RTW rates were 58% of low-skilled and 64% of high-skilled blue-collar workers compared to 80% to 89% of white-collar workers, and after 12 months 79% of low-skilled blue-collar workers compared to 87% to 92% within other occupational classes. High-skilled white-collar workers (THA: hazard ratio (HR) 2.12 (95% confidence interval (CI) 1.32 to 3.40); TKA: HR 2.31 (95% CI 1.34 to 4.00)) and low-skilled white-collar workers (TKA: HR 1.82 (95% CI 1.04 to 3.18)) had a higher hazard to RTW within six months postoperatively. Conclusion. Clear differences existed in time to RTW among both THA and TKA patients in each of the groups studied. These findings may help guide tailored patient-specific information during preoperative consultation and advice postoperatively, as well as to create awareness among workers and their employers. Cite this article: Bone Joint J 2023;105-B(9):977–984


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1020 - 1029
1 Sep 2023
Trouwborst NM ten Duis K Banierink H Doornberg JN van Helden SH Hermans E van Lieshout EMM Nijveldt R Tromp T Stirler VMA Verhofstad MHJ de Vries JPPM Wijffels MME Reininga IHF IJpma FFA

Aims. The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures. Methods. A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis. Results. Of 170 patients, 22 (13%) subsequently received a THA. Native hip survival in patients with a step-off ≤ 2 mm, > 2 to 4 mm, or > 4 mm differed at five-year follow-up (respectively: 94% vs 70% vs 74%). Native hip survival in patients with a gap ≤ 2 mm, > 2 to 4 mm, or > 4 mm differed at five-year follow-up (respectively: 100% vs 84% vs 78%). Step-off displacement > 2 mm (> 2 to 4 mm hazard ratio (HR) 4.9, > 4 mm HR 5.6) and age > 60 years (HR 2.9) were independent predictors for conversion to THA at follow-up. Conclusion. Patients with minimally displaced acetabular fractures who opt for nonoperative fracture treatment may be informed that fracture displacement (e.g. gap and step-off) up to 2 mm, as measured on CT images, results in limited risk on conversion to THA. Step-off ≥ 2 mm and age > 60 years are predictors for conversion to THA and can be helpful in the shared decision-making process. Cite this article: Bone Joint J 2023;105-B(9):1020–1029


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1313 - 1322
1 Dec 2022
Yapp LZ Clement ND Moran M Clarke JV Simpson AHRW Scott CEH

Aims. The aim of this study was to assess factors associated with the estimated lifetime risk of revision surgery after primary knee arthroplasty (KA). Methods. All patients from the Scottish Arthroplasty Project dataset undergoing primary KA during the period 1 January 1998 to 31 December 2019 were included. The cumulative incidence function for revision and death was calculated up to 20 years. Adjusted analyses used cause-specific Cox regression modelling to determine the influence of patient factors. The lifetime risk was calculated as a percentage for patients aged between 45 and 99 years using multiple-decrement life table methodology. Results. The estimated lifetime risk of revision ranged between 32.7% (95% confidence interval (CI) 22.6 to 47.3) for patients aged 45 to 49 years and 0.6% (95% CI 0.1 to 4.5) for patients aged over 90 years. At 20 years, the overall cumulative incidence of revision (6.8% (95% CI 6.6 to 7.0)) was significantly less than that of death (66.3% (95% CI 65.4 to 67.1)). Adjusted analyses demonstrated converse effect of increasing age on risk of revision (hazard ratio (HR) 0.5 (95% CI 0.5 to 0.6)) and death (HR 3.6 (95% CI 3.4 to 3.7)). Male sex was associated with increased risks of revision (HR 1.1 (95% CI 1.1 to 1.2); p < 0.001) and death (HR 1.4 (95% CI 1.3 to 1.4); p < 0.001). Compared to patients undergoing primary KA for osteoarthritis, patients with inflammatory arthropathy had a higher risk of death (HR 1.7 (95% CI 1.7 to 1.8); p < 0.001), but were less likely to be revised (HR 0.9 (95% CI 0.7 to 1.0); p < 0.001). Patients with a greater number of comorbidities (HR 1.4 (95% CI 1.3 to 1.4)) and greater levels of socioeconomic deprivation (HR 1.4 (95% CI 1.4 to 1.5)) were at increased risk of death, but neither increased the risk of revision. Conclusion. The estimated lifetime risk of revision KA varied depending on patient sex, age, and underlying diagnosis. Patients aged between 45 and 49 years had a one in three risk of undergoing revision surgery within their lifetime, which decreased with age to one in 159 in those aged 90 years or more. Cite this article: Bone Joint J 2022;104-B(12):1313–1322


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1392 - 1398
3 Oct 2020
Zhao Y Tang X Yan T Ji T Yang R Guo W

Aims. There is a lack of evidence about the risk factors for local recurrence of a giant cell tumour (GCT) of the sacrum treated with nerve-sparing surgery, probably because of the rarity of the disease. This study aimed to answer two questions: first, what is the rate of local recurrence of sacral GCT treated with nerve-sparing surgery and second, what are the risk factors for its local recurrence?. Methods. A total of 114 patients with a sacral GCT who underwent nerve-sparing surgery at our hospital between July 2005 and August 2017 were reviewed. The rate of local recurrence was determined, and Kaplan-Meier survival analysis carried out to evaluate the mean recurrence-free survival. Possible risks factors including demographics, tumour characteristics, adjuvant therapy, operation, and laboratory indices were analyzed using univariate analysis. Variables with p < 0.100 in the univariate analysis were further considered in a multivariate Cox regression analysis to identify the risk factors. Results. The rate of local recurrence of sacral GCT treated with nerve-sparing surgery was 28.95% (33/114). Multivariate Cox regression analysis showed that large tumour size (> 8.80 cm) (hazard ratio (HR) 3.16; 95% confidence interval (CI) 1.27 to 7.87; p = 0.014), high neutrophil-to-lymphocyte ratio (NLR) (> 2.09) (HR 3.13; 95% CI 1.28 to 7.62; p = 0.012), involvement of a sacroiliac joint (HR 3.09; 95% CI 1.06 to 9.04; p = 0.039), and massive intraoperative blood loss (> 1,550 ml) (HR 2.47; 95% CI 1.14 to 5.36; p = 0.022) were independent risk factors for local recurrence. Conclusion. Patients with a sacral GCT who undergo nerve-sparing surgery have a local recurrence rate of 29%. Large tumour size, high NLR, involvement of a sacroiliac joint, and massive intraoperative blood loss are independent risk factors. Cite this article: Bone Joint J 2020;102-B(10):1392–1398


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 679 - 687
1 Jun 2023
Lou Y Zhao C Cao H Yan B Chen D Jia Q Li L Xiao J

Aims. The aim of this study was to report the long-term prognosis of patients with multiple Langerhans cell histiocytosis (LCH) involving the spine, and to analyze the risk factors for progression-free survival (PFS). Methods. We included 28 patients with multiple LCH involving the spine treated between January 2009 and August 2021. Kaplan-Meier methods were applied to estimate overall survival (OS) and PFS. Univariate Cox regression analysis was used to identify variables associated with PFS. Results. Patients with multiple LCH involving the spine accounted for 15.4% (28/182 cases) of all cases of spinal LCH: their lesions primarily involved the thoracic and lumbar spines. The most common symptom was pain, followed by neurological dysfunction. All patients presented with osteolytic bone destruction, and 23 cases were accompanied by a paravertebral soft-tissue mass. The incidence of vertebra plana was low, whereas the oversleeve-like sign was a more common finding. The alkaline phosphatase was significantly higher in patients with single-system multifocal bone LCH than in patients with multisystem LCH. At final follow-up, one patient had been lost to follow-up, two patients had died, three patients had local recurrence, six patients had distant involvement, and 17 patients were alive with disease. The median PFS and OS were 50.5 months (interquartile range (IQR) 23.5 to 63.1) and 60.5 months (IQR 38.0 to 73.3), respectively. Stage (hazard ratio (HR) 4.324; p < 0.001) and chemotherapy (HR 0.203; p < 0.001) were prognostic factors for PFS. Conclusion. Pain is primarily due to segmental instability of the spine from its destruction by LCH. Chemotherapy can significantly improve PFS, and radiotherapy has achieved good results in local control. The LCH lesions in some patients will continue to progress. It may initially appear as an isolated or single-system LCH, but will gradually involve multiple sites or systems. Therefore, long-term follow-up and timely intervention are important for patients with spinal LCH. Cite this article: Bone Joint J 2023;105-B(6):679–687


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 884 - 893
1 Jul 2022
Kjærvik C Gjertsen J Stensland E Saltyte-Benth J Soereide O

Aims. This study aimed to identify risk factors (patient, healthcare system, and socioeconomic) for mortality after hip fractures and estimate their relative importance. Further, we aimed to elucidate mortality and survival patterns following fractures and the duration of excess mortality. Methods. Data on 37,394 hip fractures in the Norwegian Hip Fracture Register from January 2014 to December 2018 were linked to data from the Norwegian Patient Registry, Statistics Norway, and characteristics of acute care hospitals. Cox regression analysis was performed to estimate risk factors associated with mortality. The Wald statistic was used to estimate and illustrate relative importance of risk factors, which were categorized in modifiable (healthcare-related) and non-modifiable (patient-related and socioeconomic). We calculated standardized mortality ratios (SMRs) comparing deaths among hip fracture patients to expected deaths in a standardized reference population. Results. Mean age was 80.2 years (SD 11.4) and 67.5% (n = 25,251) were female. Patient factors (male sex, increasing comorbidity (American Society of Anesthesiologists grade and Charlson Comorbidity Index)), socioeconomic factors (low income, low education level, living in a healthcare facility), and healthcare factors (hip fracture volume, availability of orthogeriatric services) were associated with increased mortality. Non-modifiable risk factors were more strongly associated with mortality than modifiable risk factors. The SMR analysis suggested that cumulative excess mortality among hip fracture patients was 16% in the first year and 41% at six years. SMR was 2.48 for the six-year observation period, most pronounced in the first year, and fell from 10.92 in the first month to 3.53 after 12 months and 2.48 after six years. Substantial differences in median survival time were found, particularly for patient-related factors. Conclusion. Socioeconomic, patient-, and healthcare-related factors all contributed to excess mortality, and non-modifiable factors had stronger association than modifiable ones. Hip fractures contributed to substantial excess mortality. Apparently small survival differences translate into substantial disparity in median survival time in this elderly population. Cite this article: Bone Joint J 2022;104-B(7):884–893


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 729 - 735
1 Jun 2022
Craxford S Marson BA Nightingale J Forward DP Taylor A Ollivere B

Aims. The last decade has seen a marked increase in surgical rib fracture fixation (SRF). The evidence to support this comes largely from retrospective cohorts, and adjusting for the effect of other injuries sustained at the same time is challenging. This study aims to assess the impact of SRF after blunt chest trauma using national prospective registry data, while controlling for other comorbidities and injuries. Methods. A ten-year extract from the Trauma Audit and Research Network formed the study sample. Patients who underwent SRF were compared with those who received supportive care alone. The analysis was performed first for the entire eligible cohort, and then for patients with a serious (thoracic Abbreviated Injury Scale (AIS) ≥ 3) or minor (thoracic AIS < 3) chest injury without significant polytrauma. Multivariable logistic regression was performed to identify predictors of mortality. Kaplan-Meier estimators and multivariable Cox regression were performed to adjust for the effects of concomitant injuries and other comorbidities. Outcomes assessed were 30-day mortality, length of stay (LoS), and need for tracheostomy. Results. A total of 86,838 cases were analyzed. The rate of SRF was 1.2%. SRF significantly reduced risk of mortality (odds ratio (OR) 0.27 (95 confidence interval (CI) 0.128 to 0.273); p < 0.001) and need for tracheostomy (OR 0.22 (95% CI 0.191 to 0.319); p < 0.001) after adjustment for other covariables across the whole cohort. SRF remained protective in patients with a serious chest injury (hazard ratio (HR) 0.24 (95% CI 0.13 to 0.45); p < 0.001). The benefit in more minor chest injury was less clear. Mean LoS for patients who survived was longer in the SRF group (24.29 days (SD 26.54) vs 16.60 days (SD 26.35); p < 0.001). Conclusion. SRF reduces mortality after significant chest trauma associated with both major and minor polytrauma. The rate of fixation in the UK is low and potentially underused as a treatment for severe chest wall injury. Cite this article: Bone Joint J 2022;104-B(6):729–735


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 274 - 282
1 Feb 2022
Grønhaug KML Dybvik E Matre K Östman B Gjertsen J

Aims. The aim of this study was to investigate if there are differences in outcome between sliding hip screws (SHSs) and intramedullary nails (IMNs) with regard to fracture stability. Methods. We assessed data from 17,341 patients with trochanteric or subtrochanteric fractures treated with SHS or IMN in the Norwegian Hip Fracture Register from 2013 to 2019. Primary outcome measures were reoperations for stable fractures (AO Foundation/Orthopaedic Trauma Association (AO/OTA) type A1) and unstable fractures (AO/OTA type A2, A3, and subtrochanteric fractures). Secondary outcome measures were reoperations for A2, A3, and subtrochanteric fractures individually, one-year mortality, quality of life (EuroQol five-dimension three-level index score), pain (visual analogue scale (VAS)), and satisfaction (VAS) for stable and unstable fractures. Hazard rate ratios (HRRs) for reoperation were calculated using Cox regression analysis with adjustments for age, sex, and American Society of Anesthesiologists score. Results. Reoperation rate was lower after surgery with IMN for unstable fractures one year (HRR 0.82, 95% confidence interval (CI) 0.70 to 0.97; p = 0.022) and three years postoperatively (HRR 0.86, 95% CI 0.74 to 0.99; p = 0.036), compared with SHS. For individual fracture types, no clinically significant differences were found. Lower one-year mortality was found for IMN compared with SHS for stable fractures (HRR 0.87; 95% CI 0.78 to 0.96; p = 0.007), and unstable fractures (HRR 0.91, 95% CI 0.84 to 0.98; p = 0.014). Conclusion. This national register-based study indicates a lower reoperation rate for IMN than SHS for unstable trochanteric and subtrochanteric fractures, but not for stable fractures or individual fracture types. The choice of implant may not be decisive to the outcome of treatment for stable trochanteric fractures in terms of reoperation rate. One-year mortality rate for unstable and stable fractures was lower in patients treated with IMN. Cite this article: Bone Joint J 2022;104-B(2):274–282


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 203 - 211
1 Feb 2024
Park JH Won J Kim H Kim Y Kim S Han I

Aims. This study aimed to compare the performance of survival prediction models for bone metastases of the extremities (BM-E) with pathological fractures in an Asian cohort, and investigate patient characteristics associated with survival. Methods. This retrospective cohort study included 469 patients, who underwent surgery for BM-E between January 2009 and March 2022 at a tertiary hospital in South Korea. Postoperative survival was calculated using the PATHFx3.0, SPRING13, OPTIModel, SORG, and IOR models. Model performance was assessed with area under the curve (AUC), calibration curve, Brier score, and decision curve analysis. Cox regression analyses were performed to evaluate the factors contributing to survival. Results. The SORG model demonstrated the highest discriminatory accuracy with AUC (0.80 (95% confidence interval (CI) 0.76 to 0.85)) at 12 months. In calibration analysis, the PATHfx3.0 and OPTIModel models underestimated survival, while the SPRING13 and IOR models overestimated survival. The SORG model exhibited excellent calibration with intercepts of 0.10 (95% CI -0.13 to 0.33) at 12 months. The SORG model also had lower Brier scores than the null score at three and 12 months, indicating good overall performance. Decision curve analysis showed that all five survival prediction models provided greater net benefit than the default strategy of operating on either all or no patients. Rapid growth cancer and low serum albumin levels were associated with three-, six-, and 12-month survival. Conclusion. State-of-art survival prediction models for BM-E (PATHFx3.0, SPRING13, OPTIModel, SORG, and IOR models) are useful clinical tools for orthopaedic surgeons in the decision-making process for the treatment in Asian patients, with SORG models offering the best predictive performance. Rapid growth cancer and serum albumin level are independent, statistically significant factors contributing to survival following surgery of BM-E. Further refinement of survival prediction models will bring about informed and patient-specific treatment of BM-E. Cite this article: Bone Joint J 2024;106-B(2):203–211


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1725 - 1730
1 Nov 2021
Baumber R Gerrand C Cooper M Aston W

Aims. The incidence of bone metastases is between 20% to 75% depending on the type of cancer. As treatment improves, the number of patients who need surgical intervention is increasing. Identifying patients with a shorter life expectancy would allow surgical intervention with more durable reconstructions to be targeted to those most likely to benefit. While previous scoring systems have focused on surgical and oncological factors, there is a need to consider comorbidities and the physiological state of the patient, as these will also affect outcome. The primary aim of this study was to create a scoring system to estimate survival time in patients with bony metastases and to determine which factors may adversely affect this. Methods. This was a retrospective study which included all patients who had presented for surgery with metastatic bone disease. The data collected included patient, surgical, and oncological variables. Univariable and multivariable analysis identified which factors were associated with a survival time of less than six months and less than one year. A model to predict survival based on these factors was developed using Cox regression. Results. A total of 164 patients were included with a median survival time of 1.6 years (interquartile range 0.5 to 3.1) after surgery. On multivariable analysis, a higher American Society of Anesthesiologists grade (p < 0.001), a high white cell count (p = 0.002), hyponatraemia (p = 0.001), a preoperative resting heart rate of > 100 bpm (p = 0.052), and the type of primary cancer (p = 0.026) remained significant predictors of reduced survival time. The predictive model developed showed good discrimination and calibration to predict both six- and 12-month survival in patients with metastatic bone disease. Conclusion. In addition to surgical and oncological factors, the level of comorbidity and physiological state of the patient has a significant impact on survival in patients with metastatic bone disease. These factors should be considered when assessing the appropriateness of surgical intervention. This is the first study to examine other patient factors alongside surgical and oncological data to identify a relationship between these and survival. Cite this article: Bone Joint J 2021;103-B(11):1725–1730


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 522 - 528
1 May 2019
Medellin MR Fujiwara T Clark R Stevenson JD Parry M Jeys L

Aims. The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR). Patients and Methods. In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors. Results. The revision-free survival of the implant was 71% at five years and 63.3% at ten years. Three prostheses reached 15 years without revision. The mean Musculoskeletal Tumor Society score in the group was 26 (23 to 28). The mechanisms of failure were infection in 18%, structural failures in 6%, tumour progression in 5%, aseptic loosening in 2%, and soft-tissue failures in 1%. Prostheses used for primary reconstruction after oncological resections had lower infection rates than revision implants (8% vs 25%; p = 0.001). The rates of infection in silver-coated and non-silver-coated prosthesis were similar (17.4% vs 19.%; p = 0.869). The incidence of hip dislocation was 10%. Rotating hinge prosthesis had a lower failure rate than fixed hinge prosthesis (5.3% vs 11%). After Cox regression, the independent factors associated with failures were the history of previous operations (hazard ratio (HR) 3.7; p = 0.041), and the associated arthroplasty of the proximal tibia (HR 3.8; p = 0.034). At last follow-up, 11 patients (13%) required amputation. Conclusion. TFEPR offers a reliable reconstruction option for massive bone loss of the femur, with a good survival when the prosthesis is used as a primary implant. The use of a rotating hinge at the knee and dual mobility bearing at the hip may be adequate to reduce the risk of mechanical and soft-tissue failures. Infection remains the main concern and there is insufficient evidence to support the routine use of silver-coated endoprosthesis. Cite this article: Bone Joint J 2019;101-B:522–528


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 277 - 283
1 Mar 2023
Gausden EB Puri S Chiu Y Figgie MP Sculco TP Westrich G Sculco PK Chalmers BP

Aims. The purpose of this study was to assess mid-term survivorship following primary total knee arthroplasty (TKA) with Optetrak Logic components and identify the most common revision indications at a single institution. Methods. We identified a retrospective cohort of 7,941 Optetrak primary TKAs performed from January 2010 to December 2018. We reviewed the intraoperative findings of 369 TKAs that required revision TKA from January 2010 to December 2021 and the details of the revision implants used. Kaplan-Meier analysis was used to determine survivorship. Cox regression analysis was used to examine the impact of patient variables and year of implantation on survival time. Results. The estimated survivorship free of all-cause revision was 98% (95% confidence interval (CI) 97% to 98%), 95% (95% CI 95% to 96%), and 86% (95% CI 83% to 88%) at two, five, and ten years, respectively. In 209/369 revisions there was a consistent constellation of findings with varying severity that included polyethylene wear and associated synovitis, osteolysis, and component loosening. This failure mode, which we refer to as aseptic mechanical failure, was the most common revision indication. The mean time from primary TKA to revision for aseptic mechanical failure was five years (5 months to 11 years). Conclusion. In this series of nearly 8,000 primary TKAs performed with a specific implant, we identified a lower-than-expected mid-term survivorship and a high number of revisions with a unique presentation. This study, along with the recent recall of the implant, confirms the need for frequent monitoring of patients with Optetrak TKAs given the incidence of polyethylene failure, osteolysis, and component loosening. Cite this article: Bone Joint J 2023;105-B(3):277–283


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 172 - 179
1 Feb 2023
Shimizu T Kato S Demura S Shinmura K Yokogawa N Kurokawa Y Yoshioka K Murakami H Kawahara N Tsuchiya H

Aims. The aim of this study was to investigate the incidence and characteristics of instrumentation failure (IF) after total en bloc spondylectomy (TES), and to analyze risk factors for IF. Methods. The medical records from 136 patients (65 male, 71 female) with a mean age of 52.7 years (14 to 80) who underwent TES were retrospectively reviewed. The mean follow-up period was 101 months (36 to 232). Analyzed factors included incidence of IF, age, sex, BMI, history of chemotherapy or radiotherapy, tumour histology (primary or metastasis; benign or malignant), surgical approach (posterior or combined), tumour location (thoracic or lumbar; junctional or non-junctional), number of resected vertebrae (single or multilevel), anterior resection line (disc-to-disc or intravertebra), type of bone graft (autograft or frozen autograft), cage subsidence (CS), and local alignment (LA). A survival analysis of the instrumentation was performed, and relationships between IF and other factors were investigated using the Cox regression model. Results. A total of 44 patients (32.4%) developed IF at a median of 31 months (interquartile range 23 to 74) following TES. Most IFs were rod fractures preceded by a mean CS of 6.1 mm (2 to 18) and LA kyphotic enhancement of 10.8° (-1 to 36). IF-free survival rates were 75.8% at five years and 56.9% at ten years. The interval from TES to IF peaked at two to three years postoperatively and continued to occur over a period of time thereafter; the early IF-developing group had greater CS at one month postoperatively (CS1M) and more lumbar TES. CS1M ≥ 3 mm and sole use of frozen autografts were identified as independent risk factors for IF. Conclusion. IF is a common complication following TES. We have demonstrated that robust spinal reconstruction preventing CS, and high-quality bone grafting are necessary for successful reconstruction. Cite this article: Bone Joint J 2023;105-B(2):172–179


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1156 - 1167
1 Oct 2022
Holleyman RJ Khan SK Charlett A Inman DS Johansen A Brown C Barnard S Fox S Baker PN Deehan D Burton P Gregson CL

Aims. Hip fracture commonly affects the frailest patients, of whom many are care-dependent, with a disproportionate risk of contracting COVID-19. We examined the impact of COVID-19 infection on hip fracture mortality in England. Methods. We conducted a cohort study of patients with hip fracture recorded in the National Hip Fracture Database between 1 February 2019 and 31 October 2020 in England. Data were linked to Hospital Episode Statistics to quantify patient characteristics and comorbidities, Office for National Statistics mortality data, and Public Health England’s SARS-CoV-2 testing results. Multivariable Cox regression examined determinants of 90-day mortality. Excess mortality attributable to COVID-19 was quantified using Quasi-Poisson models. Results. Analysis of 102,900 hip fractures (42,630 occurring during the pandemic) revealed that among those with COVID-19 infection at presentation (n = 1,120) there was a doubling of 90-day mortality; hazard ratio (HR) 2.09 (95% confidence interval (CI) 1.89 to 2.31), while the HR for infections arising between eight and 30 days after presentation (n = 1,644) the figure was greater at 2.51 (95% CI 2.31 to 2.73). Malnutrition (1.45 (95% CI 1.19 to 1.77)) and nonoperative treatment (2.94 (95% CI 2.18 to 3.95)) were the only modifiable risk factors for death in COVID-19-positive patients. Patients who had tested positive for COVID-19 more than two weeks prior to hip fracture initially had better survival compared to those who contracted COVID-19 around the time of their hip fracture; however, survival rapidly declined and by 365 days the combination of hip fracture and COVID-19 infection was associated with a 50% mortality rate. Between 1 January and 30 June 2020, 1,273 (99.7% CI 1,077 to 1,465) excess deaths occurred within 90 days of hip fracture, representing an excess mortality of 23% (99.7% CI 20% to 26%), with most deaths occurring within 30 days. Conclusion. COVID-19 infection more than doubles the rate of early hip fracture mortality. Those contracting infection between 8 and 30 days after initial presentation are at even higher mortality risk, signalling the potential for targeted interventions during this period to improve survival. Cite this article: Bone Joint J 2022;104-B(10):1156–1167