Results 1 - 20 of 131
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1210 - 1217
1 Sep 2007
Peyser A Weil YA Brocke L Sela Y Mosheiff R Mattan Y Manor O Liebergall M

Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, controlled study was to compare the outcome of patients operated on using these two devices. We randomised 104 patients with intertrochanteric fractures (AO/OTA 31.A1–A2) to surgical treatment with either the PCCP or CHS and followed them for one year postoperatively. The mean operating blood loss was 161.0 ml (8 to 450) in the PCCP group and 374.0 ml (11 to 980) in the CHS group (Student’s t-test, p < 0.0001). The pain score and ability to bear weight were significantly better in the PCCP group at six weeks post-operatively. Analysis of the radiographs in a proportion of the patients revealed a reduced amount of medial displacement in the PCCP group (two patients, 4%) compared with the CHS group (10 patients, 18.9%); Fisher’s exact test, p < 0.02. The PCCP device was associated with reduced intra-operative blood loss, less postoperative pain and a reduced incidence of collapse of the fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 245 - 250
1 Feb 2011
Wilson J Bajwa A Kamath V Rangan A

Compression and absolute stability are important in the management of intra-articular fractures. We compared tension band wiring with plate fixation for the treatment of fractures of the olecranon by measuring compression within the fracture. Identical transverse fractures were created in models of the ulna. Tension band wires were applied to ten fractures and ten were fixed with Acumed plates. Compression was measured using a Tekscan force transducer within the fracture gap. Dynamic testing was carried out by reproducing cyclical contraction of the triceps of 20 N and of the brachialis of 10 N. Both methods were tested on each sample. Paired t-tests compared overall compression and compression at the articular side of the fracture. The mean compression for plating was 819 N (. sd. 602, 95% confidence interval (CI)) and for tension band wiring was 77 N (. sd. 19, 95% CI) (p = 0.039). The mean compression on the articular side of the fracture for plating was 343 N (. sd. 276, 95% CI) and for tension band wiring was 1 N (. sd. 2, 95% CI) (p = 0.038). During simulated movements, the mean compression was reduced in both groups, with tension band wiring at −14 N (. sd. 7) and for plating −173 N (. sd. 32). No increase in compression on the articular side was detected in the tension band wiring group. Pre-contoured plates provide significantly greater compression than tension bands in the treatment of transverse fractures of the olecranon, both over the whole fracture and specifically at the articular side of the fracture. In tension band wiring the overall compression was reduced and articular compression remained negligible during simulated contraction of the triceps, challenging the tension band principle


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1208 - 1212
1 Sep 2009
Laflamme GY Delisle J Rouleau D Uzel A Leduc S

A total of 30 patients with lateral compression fractures of the pelvis with intra-articular extension into the anterior column were followed for a mean of 4.2 years (2 to 6), using the validated functional outcome tools of the musculoskeletal function assessment and the short-form health survey (SF-36). The functional outcome was compared with that of a series of patients who had sustained type-B1 and type-C pelvic fractures. The lateral-compression group included 20 men and ten women with a mean age of 42.7 years (13 to 84) at the time of injury. Functional deficits were noted for the mental component summary score (p = 0.008) and in the social function domain (p < 0.05) of the SF-36. There was no evidence of degenerative arthritis in the lateral-compression group. However, they had high functional morbidity including greater emotional and psychological distress


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 387 - 390
1 May 1996
Lunsjö K Ceder L Stigsson L Hauggaard A

The Medoff sliding plate (MSP) is a new device used to treat intertrochanteric and subtrochanteric fractures. There are three options for sliding; either along the shaft or the neck of the femur, or a combination of both. In a prospective series of 108 consecutive displaced intertrochanteric fractures we used combined dynamic compression. The patients were followed clinically and radiologically for one year. All fractures healed during the follow-up period. The only postoperative technical failure was one lag-screw penetration. Combined compression of the MSP gives increased dynamic capacity which reduces the risk of complications. The low rate of technical failure in our series compares favourably with that of the sliding hip screw or the Gamma nail but randomised trials comparing the MSP with other hip screw systems are necessary to find the true role of the MSP with its various sliding modes


We evaluated the outcome of treatment of nonunion of an intracapsular fracture of the femoral neck in young patients using two cannulated screws and a vascularised bone graft. A total of 32 patients (15 women and 17 men, with a mean age of 36.5 years; 20 to 50) with failed internal fixation of an intracapsular fracture were included in the study. Following removal of the primary fixation, two cannulated compression screws were inserted with a vascularised iliac crest bone graft based on the ascending branch of the lateral femoral circumflex artery. At a mean follow-up of 6.8 years (4 to 10), union was achieved in 27 hips (84%). A total of five patients with a mean age of 40.5 years (35 to 50) had a persistent nonunion and underwent total hip arthroplasty as also did two patients whose fracture united but who developed osteonecrosis of the femoral head two years post-operatively. Statistical analysis showed that younger patients achieved earlier and more reliable union (p < 0.001). The functional outcome, as assessed by the Harris Hip score, was better in patients aged < 45 years compared with those aged > 45 years (p < 0.001). . These findings suggest that further fixation using two cannulated compression screws and a vascularised iliac crest bone graft is an effective salvage treatment in patients aged <  45 years, in whom osteosynthesis of a displaced intracapsular fractures of the femoral neck has failed. Cite this article: Bone Joint J 2015; 97-B:988–91


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 3 | Pages 336 - 339
1 Apr 2000
McCormack RG Brien D Buckley RE McKee MD Powell J Schemitsch EH

We randomised prospectively 44 patients with fractures of the shaft of the humerus to open reduction and internal fixation by either an intramedullary nail (IMN) or a dynamic compression plate (DCP). Patients were followed up for a minimum of six months. There were no significant differences in the function of the shoulder and elbow, as determined by the American Shoulder and Elbow Surgeons’ score, the visual analogue pain score, range of movement, or the time taken to return to normal activity. There was a single case of shoulder impingement in the DCP group and six in the IMN group. Of these six, five occurred after antegrade insertion of an IMN. In the DCP group three patients developed complications, compared with 13 in the IMN group. We had to perform secondary surgery on seven patients in the IMN group, but on only one in the DCP group (p = 0.016). Our findings suggest that open reduction and internal fixation with a DCP remains the best treatment for unstable fractures of the shaft of the humerus. Fixation by IMN may be indicated for specific situations, but is technically more demanding and has a higher rate of complications


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 19 - 22
1 Jan 2002
Kosygan KP Mohan R Newman RJ

We performed a randomised, prospective trial in 111 patients with intertrochanteric fractures of the hip comparing the use of the Gotfried percutaneous compression plate (PCCP) with that of the classic hip screw (CHS). Blood loss and transfusion requirement were less in the PCCP group but the operating time was significantly longer. The complication rate after operation was similar in both groups, and at a minimum follow-up of six months there was no difference in the rates of fracture healing or implant failure. The PCCP gives results which are similar to those obtained with a conventional device. Its suggested advantages seem to be theoretical rather than practical and, being a fixed-angle implant, it is not universally applicable


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 294 - 298
1 Feb 2021
Hadeed MM Prakash H Yarboro SR Weiss DB

Aims. The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. Methods. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals. Results. The spiral and oblique fracture patterns withstood simulated weight-bearing with minimal displacement. The multifragmented model had early implant failure with breaking of the distal locking screws. The spiral fracture model shortened by a mean of 0.3 mm (SD 0.2), and developed a mean coronal angulation of 2.0° (SD 1.9°) and a mean sagittal angulation of 1.2° (SD 1.1°). On average, 88% of the shortening, 74% of the change in coronal alignment, and 75% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. The oblique fracture model shortened by a mean of 0.2 mm (SD 0.1) and developed a mean coronal angulation of 2.4° (SD 1.6°) and a mean sagittal angulation of 2.6° (SD 1.4°). On average, 44% of the shortening, 39% of the change in coronal alignment, and 79% of the change in sagittal alignment occurred in the first 2,500 cycles. No late acceleration of displacement was noted. Conclusion. For spiral and oblique fracture patterns, simulated weight-bearing resulted in a clinically acceptable degree of displacement. Most displacement occurred early in the test period, and the rate of displacement decreased over time. Based on this model, we offer evidence that early weight-bearing appears safe for well reduced oblique and spiral fractures, but not in multifragmented patterns that have poor bone contact. Cite this article: Bone Joint J 2021;103-B(2):294–298


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 634 - 639
1 May 2018
Davda K Heidari N Calder P Goodier D

Aims. The management of a significant bony defect following excision of a diaphyseal atrophic femoral nonunion remains a challenge. We present the outcomes using a combined technique of acute femoral shortening, stabilized with a long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis with a temporary monolateral fixator. Patients and Methods. Eight men and two women underwent the ‘rail and nail’ technique between 2008 and 2016. Proximal locking of the nail and removal of the external fixator was undertaken once the length of the femur had been restored and prior to full consolidation of the regenerate. Results. The mean lengthening was 7 cm (3 to 11). The external fixator was removed at a mean of 127 days (57 to 220). The mean bone healing index was 28 days/cm and the mean external fixation index was 20 days/cm (11 to 18). There were no superficial or deep infections. Conclusion. This small retrospective study shows encouraging results for a combined technique, enabling compression of the femoral osteotomy, alignment, and controlled lengthening. Removal of the fixator and proximal locking of the nail reduces the risk of complications and stabilizes the femur with the maximum working length of the nail. Cite this article: Bone Joint J 2018;100-B:634–9


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 984 - 988
1 Jul 2010
Guo JJ Tang N Yang HL Tang TS

We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients’ age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively). After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score, but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 994 - 999
1 Sep 2024
El-Khaldi I Gude MH Gundtoft PH Viberg B

Aims

Pneumatic tourniquets are often used during the surgical treatment of unstable traumatic ankle fractures. The aim of this study was to assess the risk of reoperation after open reduction and internal fixation of ankle fractures with and without the use of pneumatic tourniquets.

Methods

This was a population-based cohort study using data from the Danish Fracture Database with a follow-up period of 24 months. Data were linked to the Danish National Patient Registry to ensure complete information regarding reoperations due to complications, which were divided into major and minor. The relative risk of reoperations for the tourniquet group compared with the non-tourniquet group was estimated using Cox proportional hazards modelling.


The Bone & Joint Journal
Vol. 107-B, Issue 2 | Pages 204 - 212
1 Feb 2025
Trouwborst NM Oldhoff MGE ten Duis K van Helden SH Hermans E Jaarsma RL van Lieshout EMM Reininga IHF Tromp TN Verhofstad MHJ de Vries JPM Wijffels MME Meesters AML IJpma FFA

Aims

The aim of the study was to apply 3D measurements for fracture displacement in minimally to moderately displaced acetabular fractures treated nonoperatively, and to evaluate whether this measurement can be used to estimate the likelihood of conversion to total hip arthroplasty (THA) at follow-up.

Methods

A multicentre, cross-sectional study was performed on 144 patients who were treated nonoperatively for an acetabular fracture in four level 1 trauma centres between January 2000 and December 2020. For each patient, fracture displacement was measured on CT-based 3D models. The 3D gap area represents fracture displacement (mm2) between all fracture fragments. A receiver operating characteristic curve was generated to determine a 3D gap area threshold representing the optimal sensitivity and specificity to predict conversion to THA. Native hip survival was reported using Kaplan-Meier curves. Predictors of conversion to THA were determined using Cox regression analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 613 - 622
1 Jun 2024
Shen J Wei Z Wu H Wang X Wang S Wang G Luo F Xie Z

Aims

The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes.

Methods

Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1020 - 1029
1 Sep 2023
Trouwborst NM ten Duis K Banierink H Doornberg JN van Helden SH Hermans E van Lieshout EMM Nijveldt R Tromp T Stirler VMA Verhofstad MHJ de Vries JPPM Wijffels MME Reininga IHF IJpma FFA

Aims

The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures.

Methods

A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis.


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 72 - 81
1 Jan 2023
Stake IK Ræder BW Gregersen MG Molund M Wang J Madsen JE Husebye EE

Aims

The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients.

Methods

In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable AO/OTA type 44-B fracture of the ankle were randomized to fixation with either a nail or a plate and followed for 24 months after surgery. The primary outcome measure was the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot score. Secondary outcome measures were the Manchester-Oxford Foot Questionnaire, the Olerud and Molander Ankle score, the EuroQol five-dimension questionnaire, a visual analogue score for pain, complications, the quality of reduction of the fracture, nonunion, and the development of osteoarthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1117 - 1122
1 Aug 2005
Fuchs S Heyse T Rudofsky G Gosheger G Chylarecki C

There is a high risk of venous thromboembolism when patients are immobilised following trauma. The combination of low-molecular-weight heparin (LMWH) with graduated compression stockings is frequently used in orthopaedic surgery to try and prevent this, but a relatively high incidence of thromboembolic events remains. Mechanical devices which perform continuous passive motion imitate contractions and increase the volume and velocity of venous flow. In this study 227 trauma patients were randomised to receive either treatment with the Arthroflow device and LMWH or only with the latter. The Arthroflow device passively extends and plantarflexes the feet. Patients were assessed initially by venous-occlusion plethysmography, compression ultrasonography and continuous wave Doppler, which were repeated weekly without knowledge of the category of randomisation. Those who showed evidence of deep-vein thrombosis underwent venography for confirmation. The incidence of deep-vein thrombosis was 25% in the LMWH group compared with 3.6% in those who had additional treatment with the Arthroflow device (p < 0.001). There were no substantial complications or problems of non-compliance with the Arthroflow device. Logistic regression analysis of the risk factors of deep-vein thrombosis showed high odds ratios for operation (4.1), immobilisation (4.3), older than 40 years of age (2.8) and obesity (2.2)


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1263 - 1268
1 Sep 2013
Savaridas T Wallace RJ Salter DM Simpson AHRW

Fracture repair occurs by two broad mechanisms: direct healing, and indirect healing with callus formation. The effects of bisphosphonates on fracture repair have been assessed only in models of indirect fracture healing. A rodent model of rigid compression plate fixation of a standardised tibial osteotomy was used. Ten skeletally mature Sprague–Dawley rats received daily subcutaneous injections of 1 µg/kg ibandronate (IBAN) and ten control rats received saline (control). Three weeks later a tibial osteotomy was rigidly fixed with compression plating. Six weeks later the animals were killed. Fracture repair was assessed with mechanical testing, radiographs and histology. The mean stress at failure in a four-point bending test was significantly lower in the IBAN group compared with controls (8.69 Nmm. -2. (. sd. 7.63) vs 24.65 Nmm. -2. (. sd. 6.15); p = 0.017). On contact radiographs of the extricated tibiae the mean bone density assessment at the osteotomy site was lower in the IBAN group than in controls (3.7 mmAl (. sd. 0.75) vs 4.6 mmAl (. sd. 0.57); p = 0.01). In addition, histological analysis revealed progression to fracture union in the controls but impaired fracture healing in the IBAN group, with predominantly cartilage-like and undifferentiated mesenchymal tissue (p = 0.007). . Bisphosphonate treatment in a therapeutic dose, as used for risk reduction in fragility fractures, had an inhibitory effect on direct fracture healing. We propose that bisphosphonate therapy not be commenced until after the fracture has united if the fracture has been rigidly fixed and is undergoing direct osteonal healing. Cite this article: Bone Joint J 2013;95-B:1263–8


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 955 - 962
1 Nov 1999
Lindahl J Hirvensalo E Böstman O Santavirta S

We reviewed 110 patients with an unstable fracture of the pelvic ring who had been treated with a trapezoidal external fixator after a mean follow-up of 4.1 years. There were eight open-book (type B1, B3-1) injuries, 62 lateral compression (type B2, B3-2) and 40 rotationally and vertically unstable (type C1-C3) injuries. The rate of complications was high with loss of reduction in 57%, malunion in 58%, nonunion in 5%, infection at the pin site in 24%, loosening of the pins in 2%, injury to the lateral femoral cutaneous nerve in 2%, and pressure sores in 3%. The external fixator failed to give and maintain a proper reduction in six of the eight open-book injuries, in 20 of the 62 lateral compression injuries, and in 38 of the 40 type-C injuries. Poor functional results were usually associated with failure of reduction and an unsatisfactory radiological appearance. In type-C injuries more than 10 mm of residual vertical displacement of the injury to the posterior pelvic ring was significantly related to poor outcome. In 14 patients in this unsatisfactory group poor functional results were also affected by associated nerve injuries. In lateral compression injuries the degree of displacement of fractures of the pubic rami caused by internal rotation of the hemipelvis was an important prognostic factor. External fixation may be useful in the acute phase of resuscitation but it is of limited value in the definitive treatment of an unstable type-C injury and in type-B open-book injuries. It is usually unnecessary in minimally displaced lateral compression injuries


The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 283 - 289
1 Feb 2022
Cerbasi S Bernasconi A Balato G Dimitri F Zingaretti O Orabona G Pascarella R Mariconda M

Aims

The aims of this study were to assess the pre- and postoperative incidence of deep vein thrombosis (DVT) using routine duplex Doppler ultrasound (DUS), to assess the incidence of pulmonary embolism (PE) using CT angiography, and to identify the factors that predict postoperative DVT in patients with a pelvic and/or acetabular fracture.

Methods

All patients treated surgically for a pelvic and/or acetabular fracture between October 2016 and January 2020 were enrolled into this prospective single-centre study. The demographic, medical, and surgical details of the patients were recorded. DVT screening of the lower limbs was routinely performed using DUS before and at six to ten days after surgery. CT angiography was used in patients who were suspected of having PE. Age-adjusted univariate and stepwise multiple logistic regression analysis were used to determine the association between explanatory variables and postoperative DVT.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1403 - 1408
1 Oct 2012
Hannemann PFW Göttgens KWA van Wely BJ Kolkman KA Werre AJ Poeze M Brink PRG

The use of pulsed electromagnetic fields (PEMF) to stimulate bone growth has been recommended as an alternative to the surgical treatment of ununited scaphoid fractures, but has never been examined in acute fractures. We hypothesised that the use of PEMF in acute scaphoid fractures would accelerate the time to union by 30% in a randomised, double-blind, placebo-controlled, multicentre trial. A total of 53 patients in three different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly assigned to receive either treatment with PEMF (n = 24) or a placebo (n = 29). The clinical and radiological outcomes were assessed at four, six, nine, 12, 24 and 52 weeks. A log-rank analysis showed that neither time to clinical and radiological union nor the functional outcome differed significantly between the groups. The clinical assessment of union indicated that at six weeks tenderness in the anatomic snuffbox (p = 0.03) as well as tenderness on longitudinal compression of the scaphoid (p = 0.008) differed significantly in favour of the placebo group. We conclude that stimulation of bone growth by PEMF has no additional value in the conservative treatment of acute scaphoid fractures