Aims. Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis
Aims. The consensus is that bipolar hemiarthroplasty (BHA) in allograft-prosthesis
We retrospectively studied 14 patients with proximal and diaphyseal tumours and disappearing bone (Gorham’s) disease of the humerus treated with wide resection and reconstruction using an allograft-resurfacing
Autogenous bone graft which has been either autoclaved or irradiated is commonly used in oriental countries as an alternative to allograft. We started to use the technique of extracorporeal irradiation of the resected specimen and reimplantation (ECIR) in 1991. There was, however, a high incidence of fracture of the irradiated bone and loss of articular cartilage. In an attempt to reduce these complications, we combined the irradiated autograft with a conventional arthroplasty. Between 1995 and 1998, 14 patients underwent limb salvage by this method. Seven had an osteosarcoma, two bony metastases, three a chondrosarcoma, one a malignant fibrous histiocytoma, and one a leiomyosarcoma. Ten tumours were located in the proximal femur, two in the proximal humerus, and two in the distal femur. One patient who had a solitary metastasis in the proximal part of the left femur died from lung metastases 13 months after operation. The remaining 13 patients were alive and without evidence of local recurrence or distant metastases at a mean follow-up of 43 months (28 to 72). Postoperative palsy of the sciatic nerve occurred in one patient, but no complications such as wound infection, fracture, or nonunion were seen. All host-irradiated bone junctions healed uneventfully within eight months. Using the Enneking functional evaluation system, the mean postoperative score for all 14 patients was 80% (57 to 93). The use of irradiated autograft prosthesis
Giant cell tumour is the most common aggressive
benign tumour of the musculoskeletal system and has a high rate of
local recurrence. When it occurs in proximity to the hip, reconstruction
of the joint is a challenge. Options for reconstruction after wide
resection include the use of a megaprosthesis or an allograft-prosthesis
composite. We performed a clinical and radiological study to evaluate
the functional results of a proximal femoral allograft-prosthesis
composite in the treatment of proximal femoral giant cell tumour
after wide resection. This was an observational study, between 2006
and 2012, of 18 patients with a mean age of 32 years (28 to 42)
and a mean follow-up of 54 months (18 to 79). We achieved excellent
outcomes using Harris Hip Score in 13 patients and a good outcome
in five. All allografts united. There were no complications such
as infection, failure, fracture or resorption of the graft, or recurrent
tumour. Resection and reconstruction of giant cell tumours with
proximal femoral allograft–prosthesis
Aims. We present a retrospective review of patients treated with extracorporeally
irradiated allografts for primary and secondary bone tumours with
the mid- and long-term survivorship and the functional and radiographic
outcomes. Patients and Methods. A total of 113 of 116 (97.4%) patients who were treated with
extracorporeally irradiated allografts between 1996 and 2014 were
followed up. Forms of treatment included reconstructions, prostheses
and
Intra-articular (IA) tumours around the knee are treated with extra-articular (EA) resection, which is associated with poor functional outcomes. We aim to evaluate the accuracy of MRI in predicting IA involvement around the knee. We identified 63 cases of high-grade sarcomas in or around the distal femur that underwent an EA resection from a prospectively maintained database (January 1996 to April 2020). Suspicion of IA disease was noted in 52 cases, six had IA pathological fracture, two had an effusion, two had prior surgical intervention (curettage/IA intervention), and one had an osseous metastasis in the proximal tibia. To ascertain validity, two musculoskeletal radiologists (R1, R2) reviewed the preoperative imaging (MRI) of 63 consecutive cases on two occasions six weeks apart. The radiological criteria for IA disease comprised evidence of tumour extension within the suprapatellar pouch, intercondylar notch, extension along medial/lateral retinaculum, and presence of IA fracture. The radiological predictions were then confirmed with the final histopathology of the resected specimens.Aims
Methods
The scapula is a rare site for a primary bone tumour. Only a small number of series have studied patient outcomes after treatment. Previous studies have shown a high rate of recurrence, with functional outcomes determined by the preservation of the glenohumeral joint and deltoid. The purpose of the current study was to report the outcome of patients who had undergone tumour resection that included the scapula. We reviewed 61 patients (37 male, 24 female; mean age 42 years (SD 19)) who had undergone resection of the scapula. The most common resection was type 2 (n = 34) according to the Tikhoff-Linberg classification, or type S1A (n = 35) on the Enneking classification.Aims
Methods
This study aimed to analyze the accuracy and errors associated with 3D-printed, patient-specific resection guides (3DP-PSRGs) used for bone tumour resection. We retrospectively reviewed 29 bone tumour resections that used 3DP-PSRGs based on 3D CT and 3D MRI. We evaluated the resection amount errors and resection margin errors relative to the preoperative plans. Guide-fitting errors and guide distortion were evaluated intraoperatively and one month postoperatively, respectively. We categorized each of these error types into three grades (grade 1, < 1 mm; grade 2, 1 to 3 mm; and grade 3, > 3 mm) to evaluate the overall accuracy.Aims
Methods
In 1999, we developed a technique for biological
reconstruction after excision of a bone tumour, which involved using
autografts of the bone containing the tumour treated with liquid
nitrogen. We have previously reported the use of this technique
in 28 patients at a mean follow up of 27 months (10 to 54). In this study, we included 72 patients who underwent reconstruction
using this technique. A total of 33 patients died and three were
lost to follow-up, at a mean of 23Â months (2 to 56) post-operatively,
leaving 36 patients available for a assessment at a mean of 101
months 16 to 163) post-operatively. The methods of reconstruction included
an osteo-articular graft in 16, an intercalary in 13 and, a composite
graft with prosthesis in seven. Post-operative function was excellent in 26 patients (72.2%),
good in seven (19.4%), and fair in three (8.3%) according to the
functional evaluation system of Enneking. No recurrent tumour occurred
within the grafts. The autografts survived in 29 patients (80.6%),
and the rates of survival at five and ten years were 86.1% and 80.6
%, respectively. Seven of 16Â osteo-articular grafts (44%) failed
because of fracture or infection, but all the
The aim of this study was to investigate the feasibility of application of a 3D-printed megaprosthesis with hemiarthroplasty design for defects of the distal humerus or proximal ulna following tumour resection. From June 2018 to January 2020, 13 patients with aggressive or malignant tumours involving the distal humerus (n = 8) or proximal ulna (n = 5) were treated by en bloc resection and reconstruction with a 3D-printed megaprosthesis with hemiarthroplasty, designed in our centre. In this paper, we summarize the baseline and operative data, oncological outcome, complication profiles, and functional status of these patients.Aims
Methods
The modified Glasgow Prognostic Score (mGPS) uses preoperative CRP and albumin to calculate a score from 0 to 2 (2 being associated with poor outcomes). mGPS is validated in multiple carcinomas. To date, its use in soft-tissue sarcoma (STS) is limited, with only small cohorts reporting that increased mGPS scores correlates with decreased survival in STS patients. This retrospective multicentre cohort study identified 493 STS patients using clinical databases from six collaborating hospitals in three countries. Centres performed a retrospective data collection for patient demographics, preoperative blood results (CRP and albumin levels and neutrophil, leucocyte, and platelets counts), and oncological outcomes (disease-free survival, local, or metastatic recurrence) with a minimum of two years' follow-up.Aims
Methods
Hip reconstruction after resection of a periacetabular chondrosarcoma is complex and associated with a high rate of complications. Previous reports have compared no reconstruction with historical techniques that are no longer used. The aim of this study was to compare the results of tantalum acetabular reconstruction to both historical techniques and no reconstruction. We reviewed 66 patients (45 males and 21 females) with a mean age of 53 years (24 to 81) who had undergone acetabular resection for chondrosarcoma. A total of 36 patients (54%) underwent acetabular reconstruction, most commonly with a saddle prosthesis (n = 13; 36%) or a tantalum total hip arthroplasty (THA) (n = 10; 28%). Mean follow-up was nine years (SD 4).Aims
Methods
We describe a method of reconstruction using tumour-bearing autograft treated by liquid nitrogen in 28 patients. The operative technique consisted of en bloc excision of the tumour, removal of soft tissue, curettage of the tumour, drilling and preparation for internal fixation or prosthetic replacement before incubation for 20 minutes in liquid nitrogen, thawing at room temperature for 15 minutes, thawing in distilled water for ten minutes, and internal fixation with an intramedullary nail, plate or
We have evaluated the survivorship, outcomes, and failures of an interlocking, reconstruction-mode stem-sideplate implant used to preserve the native hip joint and achieve proximal fixation when there is little residual femur during large endoprosthetic reconstruction of the distal femur. A total of 14 patients underwent primary or revision reconstruction of a large femoral defect with a short remaining proximal femur using an interlocking, reconstruction-mode stem-sideplate for fixation after oncological distal femoral and diaphyseal resections. The implant was attached to a standard endoprosthetic reconstruction system. The implant was attached to a standard endoprosthetic reconstruction system. None of the femoral revisions were amenable to standard cemented or uncemented stem fixation. Patient and disease characteristics, surgical history, final ambulatory statusAims
Methods
The use of frozen tumour-bearing autograft combined with a vascularized fibular graft (VFG) represents a new technique for biological reconstruction of massive bone defect. We have compared the clinical outcomes between this technique and Capanna reconstruction. From June 2011 to January 2016 a retrospective study was carried out of patients with primary osteosarcoma of lower limbs who underwent combined biological intercalary reconstruction. Patients were categorized into two groups based on the reconstructive technique: frozen tumour-bearing autograft combined with concurrent VFG (Group 1) and the Capanna method (Group 2). Demographics, operating procedures, oncological outcomes, graft union, limb function, and postoperative complications were compared.Aims
Methods
Iliac wing (Type I) and iliosacral (Type I/IV) pelvic resections for a primary bone tumour create a large segmental defect in the pelvic ring. The management of this defect is controversial as the surgeon may choose to reconstruct it or not. When no reconstruction is undertaken, the residual ilium collapses back onto the remaining sacrum forming an iliosacral pseudarthrosis. The aim of this study was to evaluate the long-term oncological outcome, complications, and functional outcome after pelvic resection without reconstruction. Between 1989 and 2015, 32 patients underwent a Type I or Type I/IV pelvic resection without reconstruction for a primary bone tumour. There were 21 men and 11 women with a mean age of 35 years (15 to 85). The most common diagnosis was chondrosarcoma (50%, n = 16). Local recurrence-free, metastasis-free, and overall survival were assessed using the Kaplan-Meier method. Patient function was evaluated using the Musculoskeletal Tumour Society (MSTS) and Toronto Extremity Salvage Score (TESS).Aims
Methods
The purpose of this study was to report the long-term results of extendable endoprostheses of the humerus in children after the resection of a bone sarcoma. A total of 35 consecutive patients treated with extendable endoprosthetic replacement of the humerus in children were included. There were 17 boys and 18 girls in the series with a median age at the time of initial surgery of nine years (interquartile range (IQR) 7 to 11).Aims
Methods
For paediatric and adolescent patients with growth potential, preservation of the physiological joint by transepiphyseal resection (TER) of the femur confers definite advantages over arthroplasty procedures. We hypothesized that the extent of the tumour and changes in its extent after neoadjuvant chemotherapy are essential factors in the selection of this procedure, and can be assessed with MRI. The oncological and functional outcomes of the procedure were reviewed to confirm its safety and efficacy. We retrospectively reviewed 16 patients (seven male and nine female, mean age 12.2 years (7 to 16)) with osteosarcoma of the knee who had been treated by TER. We evaluated the MRI scans before and after neoadjuvant chemotherapy for all patients to assess the extent of the disease and the response to treatment.Aims
Methods
Aseptic loosening is a major cause of failure in cemented endoprosthetic reconstructions. This paper presents the long-term outcomes of a custom-designed cross-pin fixation construct designed to minimize rotational stress and subsequent aseptic loosening in selected patients. The paper will also examine the long-term survivorship and modes of failure when using this technique. A review of 658 consecutive, prospectively collected cemented endoprosthetic reconstructions for oncological diagnoses at a single centre between 1980 and 2017 was performed. A total of 51 patients were identified with 56 endoprosthetic implants with cross-pin fixation, 21 of which were implanted following primary resection of tumour. Locations included distal femoral (n = 36), proximal femoral (n = 7), intercalary (n = 6), proximal humeral (n = 3), proximal tibial (n = 3), and distal humeral (n = 1).Aims
Patients and Methods