Aims. It is not clear whether
The clinical diagnosis of a partial tear of the
anterior cruciate ligament (ACL) is still subject to debate. Little
is known about the contribution of each ACL bundle during the Lachman
test. We investigated this using six fresh-frozen cadaveric lower
limbs. Screws were placed in the femora and tibiae as fixed landmarks
for digitisation of the bone positions. The femur was secured horizontally
in a clamp. A metal hook was screwed to the tibial tubercle and
used to apply a load of 150 N directed anteroposteriorly to the
tibia to simulate the Lachman test. The knees then received constant
axial compression and 3D knee kinematic data were collected by digitising
the screw head positions in 30° flexion under each test condition.
Measurements of tibial translation and rotation were made, first with
the ACL intact, then after sequential cutting of the ACL bundles,
and finally after complete division of the ACL. Two-way analysis
of variance analysis was performed. During the Lachman test, in all knees and in all test conditions,
lateral tibial translation exceeded that on the medial side. With
an intact ACL, both
The purpose of this study was to test the hypothesis that patella alta leads to a less favourable situation in terms of patellofemoral contact force, contact area and contact pressure than the normal patellar position, and thereby gives rise to
Excessive foot pronation has been considered to be related to
Mechanical failure because of wear or fracture of the polyethylene tibial post in posteriorly-stabilised total knee replacements has been extensively described. In this study of 12 patients with a clinically and radiologically successful NexGen LPS posteriorly-stabilised prosthesis impingement of the
Out of a total of 623 patients who, over a ten-year period, underwent primary total knee replacement (TKR) without patellar resurfacing, 20 underwent secondary resurfacing for chronic
The biomechanical function of the anteromedial
(AM) and posterolateral (PL) bundles of the
Anterior cruciate ligament (ACL) reconstruction
is commonly performed and has been for many years. Despite this, the
technical details related to ACL anatomy, such as tunnel placement,
are still a topic for debate. In this paper, we introduce the flat
ribbon concept of the anatomy of the ACL, and its relevance to clinical
practice. Cite this article:
We examined the association of graft type with
the risk of early revision of primary anterior cruciate ligament reconstruction
(ACLR) in a community-based sample. A retrospective analysis of
a cohort of 9817 ACLRs recorded in an ACLR Registry was performed.
Patients were included if they underwent primary ACLR with bone–patellar tendon–bone
autograft, hamstring tendon autograft or allograft tissue. Aseptic
failure was the main endpoint of the study. After adjusting for
age, gender, ethnicity, and body mass index, allografts had a
3.02 times (95% confidence interval (CI) 1.93 to 4.72) higher risk
of aseptic revision than bone–patellar tendon–bone autografts (p
<
0.001). Hamstring tendon autografts had a 1.82 times (95% CI
1.10 to 3.00) higher risk of revision compared with bone–patellar
tendon–bone autografts (p = 0.019). For each year increase in age,
the risk of revision decreased by 7% (95% CI 5 to 9). In gender-specific
analyses a 2.26 times (95% CI 1.15 to 4.44) increased risk of hamstring
tendon autograft revision in females was observed compared with
bone–patellar tendon–bone autograft. We conclude that allograft
tissue, hamstring tendon autografts, and younger age may all increase
the risk of early revision surgery after ACLR. Cite this article:
To examine the rates of hamstring graft salvage with arthroscopic
debridement of infected anterior cruciate ligament (ACL) reconstruction
as reported in the literature and discuss functional outcomes. A search was performed without language restriction on PubMed,
EMBASE, Ovid, CINAHL and Cochrane Register of Controlled Trials
(CENTRAL) databases from their inception to April 2015. We identified
147 infected hamstring grafts across 16 included studies. Meta-analysis
was performed using a random-effects model to estimate the overall
graft salvage rate, incorporating two different definitions of graft
salvage.Aims
Materials and Methods
The aim of this study was to investigate the long-term clinical
and radiological outcome of patients who suffer recurrent injuries
to the anterior cruciate ligament (ACL) after reconstruction and
require revision surgery. From a consecutive series of 200 patients who underwent primary
reconstruction following rupture of the ACL, we identified 36 who
sustained a further rupture, 29 of whom underwent revision surgery.
Patients were reviewed prospectively at one, two, seven, 15 and
about 20 years after their original surgery. Primary outcome measures
were the number of further ruptures, the posterior tibial slope
(PTS), and functional and radiological outcomes. These were compared
with a gender and age matched cohort of patients who underwent primary
ACL reconstruction only.Aims
Patients and Methods
Loss of proprioception following an anterior
cruciate ligament (ACL) injury has been well documented. We evaluated
proprioception in both the injured and the uninjured limb in 25 patients
with ACL injury and in 25 healthy controls, as assessed by joint
position sense (JPS), the threshold for the detection of passive
movement (TDPM) and postural sway during single-limb stance on a
force plate. There were significant proprioceptive deficits in both ACL-deficient
and uninjured knees compared with control knees, as assessed by
the angle reproduction test (on JPS) and postural sway on single
limb stance. The degree of loss of proprioception in the ACL-deficient
knee and the unaffected contralateral knee joint in the same patient
was similar. The TDPM in the injured knee was significantly higher
than that of controls at 30° and 70° of flexion. The TDPM of the
contralateral knee joint was not significantly different from that
in controls. Based on these findings, the effect of proprioceptive training
of the contralateral uninjured knee should be explored. Cite this article:
We investigated the role of a functional brace worn for four months in the treatment of patients with an acute isolated tear of the posterior cruciate ligament to determine whether reduction of the posterior tibial translation during the healing period would give an improved final position of the tibia. The initial and follow-up stability was tested by Rolimeter arthrometry and radiography. The clinical outcome was evaluated using the Lysholm score, the Tegner score and the International Knee Documentation Committee scoring system at follow-up at one and two years. In all, 21 patients were studied, 21 of whom had completed one-year and 17 a two-year follow-up. The initial mean posterior sag (Rolimeter measurement) of 7.1 mm (5 to 10) was significantly reduced after 12 months to a mean of 2.3 mm (0 to 6, p <
0.001) and to a mean of 3.2 mm (2 to 7, p = 0.001) after 24 months. Radiological measurement gave similar results. The mean pre-injury Lysholm score was normal at 98 (95 to 100). At follow-up, a slight decrease in the mean values was observed to 94.0 (79 to 100, p = 0.001) at one year and 94.0 (88 to 100, p = 0.027, at two years). We concluded that the posterior cruciate ligament has an intrinsic healing capacity and, if the posteriorly translated tibia is reduced to a physiological position, it can heal with less attentuation. The applied treatment produces a good to excellent functional result.
We investigated whether strontium-enriched calcium
phosphate cement (Sr-CPC)-treated soft-tissue tendon graft results
in accelerated healing within the bone tunnel in reconstruction
of the anterior cruciate ligament (ACL). A total of 30 single-bundle
ACL reconstructions using tendo Achillis allograft were performed
in 15 rabbits. The graft on the tested limb was treated with Sr-CPC,
whereas that on the contralateral limb was untreated and served
as a control. At timepoints three, six, nine, 12 and 24 weeks after
surgery, three animals were killed for histological examination.
At six weeks, the graft–bone interface in the control group was
filled in with fibrovascular tissue. However, the gap in the Sr-CPC
group had already been completely filled in with new bone, and there
was evidence of the early formation of Sharpey fibres. At 24 weeks,
remodelling into a normal ACL–bone-like insertion was found in the
Sr-CPC group. Coating of Sr-CPC on soft tissue tendon allograft
leads to accelerated graft healing within the bone tunnel in a rabbit
model of ACL reconstruction using Achilles tendon allograft. Cite this article:
Aims. This systematic review and meta-analysis aimed to compare the influence of patellar resurfacing following cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA) on the incidence of
Aims. The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). Methods. A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years. Results. The BCR-TKA demonstrated a kinematic pattern comparable to the natural knee’s screw-home mechanism in the step-up task. In the lunge task, the medial CP of the BCR-TKA was more
Aims. The surgical target for optimal implant positioning in robotic-assisted total knee arthroplasty remains the subject of ongoing discussion. One of the proposed targets is to recreate the knee’s functional behaviour as per its pre-diseased state. The aim of this study was to optimize implant positioning, starting from mechanical alignment (MA), toward restoring the pre-diseased status, including ligament strain and kinematic patterns, in a patient population. Methods. We used an active appearance model-based approach to segment the preoperative CT of 21 osteoarthritic patients, which identified the osteophyte-free surfaces and estimated cartilage from the segmented bones; these geometries were used to construct patient-specific musculoskeletal models of the pre-diseased knee. Subsequently, implantations were simulated using the MA method, and a previously developed optimization technique was employed to find the optimal implant position that minimized the root mean square deviation between pre-diseased and postoperative ligament strains and kinematics. Results. There were evident biomechanical differences between the simulated patient models, but also trends that appeared reproducible at the population level. Optimizing the implant position significantly reduced the maximum observed strain root mean square deviations within the cohort from 36.5% to below 5.3% for all but the anterolateral ligament; and concomitantly reduced the kinematic deviations from 3.8 mm (SD 1.7) and 4.7° (SD 1.9°) with MA to 2.7 mm (SD 1.4) and 3.7° (SD 1.9°) relative to the pre-diseased state. To achieve this, the femoral component consistently required translational adjustments in the
Aims. A fracture of the medial tibial plateau is a serious complication of Oxford mobile-bearing unicompartmental knee arthroplasty (OUKA). The risk of these fractures is reportedly lower when using components with a longer keel-cortex distance (KCDs). The aim of this study was to examine how slight varus placement of the tibial component might affect the KCDs, and the rate of tibial plateau fracture, in a clinical setting. Methods. This retrospective study included 255 patients who underwent 305 OUKAs with cementless tibial components. There were 52 males and 203 females. Their mean age was 73.1 years (47 to 91), and the mean follow-up was 1.9 years (1.0 to 2.0). In 217 knees in 187 patients in the conventional group, tibial cuts were made orthogonally to the tibial axis. The varus group included 88 knees in 68 patients, and tibial cuts were made slightly varus using a new osteotomy guide.
Aims. The aims of this study were to investigate the ability to kneel after total knee arthroplasty (TKA) without patellar resurfacing, and its effect on patient-reported outcome measures (PROMs). Secondary aims included identifying which kneeling positions were most important to patients, and the influence of radiological parameters on the ability to kneel before and after TKA. Methods. This prospective longitudinal study involved 209 patients who underwent single radius cruciate-retaining TKA without patellar resurfacing. Preoperative EuroQol five-dimension questionnaire (EQ-5D), Oxford Knee Score (OKS), and the ability to achieve four kneeling positions were assessed including a single leg kneel, a double leg kneel, a high-flexion kneel, and a praying position. The severity of radiological osteoarthritis (OA) was graded and the pattern of OA was recorded intraoperatively. The flexion of the femoral component, posterior condylar offset, and
Aims. Anterior cruciate ligament (ACL) rupture commonly leads to post-traumatic osteoarthritis, regardless of surgical reconstruction. This study uses standing MRI to investigate changes in contact area, contact centroid location, and tibiofemoral alignment between ACL-injured knees and healthy controls, to examine the effect of ACL reconstruction on these parameters. Methods. An upright, open MRI was used to directly measure tibiofemoral contact area, centroid location, and alignment in 18 individuals with unilateral ACL rupture within the last five years. Eight participants had been treated nonoperatively and ten had ACL reconstruction performed within one year of injury. All participants were high-functioning and had returned to sport or recreational activities. Healthy contralateral knees served as controls. Participants were imaged in a standing posture with knees fully extended. Results. Participants’ mean age was 28.4 years (SD 7.3), the mean time since injury was 2.7 years (SD 1.6), and the mean International Knee Documentation Subjective Knee Form score was 84.4 (SD 13.5). ACL injury was associated with a 10% increase (p = 0.001) in contact area, controlling for compartment, sex, posture, age, body mass, and time since injury. ACL injury was associated with a 5.2% more posteriorly translated medial centroid (p = 0.001), equivalent to a 2.6 mm posterior translation on a representative tibia with mean posteroanterior width of 49.4 mm. Relative to the femur, the tibiae of ACL ruptured knees were 2.3 mm more