A consecutive series of 235 total knee arthroplasties using the PFC system was followed prospectively for at least ten years in 186 patients. The operation was for osteoarthritis in 150 knees, for rheumatoid arthritis in 83, and for Paget’s disease and femoral osteonecrosis in one knee each. At the latest review 56 patients had died, fi ve were too ill to assess and three could not be traced. The PFC knee replacement utilised was a nonconforming posterior-cruciate-retaining prosthesis with a polyethylene insert which is fl at in the sagittal plane. The patella was resurfaced using a metal-backed component in 170 cases, but later in the series we used an
Fungal peri-prosthetic infections of the knee
and hip are rare but likely to result in devastating complications.
In this study we evaluated the results of their management using
a single-stage exchange technique. Between 2001 and 2011, 14 patients
(ten hips, four knees) were treated for a peri-prosthetic fungal
infection. One patient was excluded because revision surgery was
not possible owing to a large acetabular defect. One patient developed
a further infection two months post-operatively and was excluded
from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients
were available for follow-up. One patient, undergoing revision replacement
of the hip, had a post-operative dislocation. Another patient, undergoing
revision replacement of the knee, developed a wound infection and
required revision 29 months post-operatively following a peri-prosthetic femoral
fracture. The mean Harris hip score increased to 74 points (63 to 84; p
<
0.02) in those undergoing revision replacement of the hip,
and the mean Hospital for Special Surgery knee score increased to
75 points (70 to 80; p <
0.01) in those undergoing revision replacement
of the knee. A single-stage revision following fungal peri-prosthetic infection
is feasible, with an acceptable rate of a satisfactory outcome. Cite this article:
Between 1988 and 1998 we implanted 318 total hip replacements (THRs) in 287 patients using the Plasmacup (B. Braun Ltd, Sheffield, United Kingdom) and a conventional metal-on-polyethylene articulation. The main indications for THR were primary or secondary osteoarthritis. At follow-up after a mean 11.6 years (7.6 to 18.4) 17 patients had died and 20 could not be traced leaving a final series of 280 THRs in 250 patients. There were 62 revisions (22.1%) in 59 patients. A total of 43 acetabular shells (15.4%) had been revised and 13 (4.6%) had undergone exchange of the liner. The most frequent indications for revision were osteolysis and aseptic loosening, followed by polyethylene wear. The mean Kaplan-Meier survival of the Plasmacup was 91% at ten years and 58% at 14 years. Osteolysis was found around 36 (17.1%) of the 211 surviving shells. The median annual rate of linear wear in the surviving shells was 0.12 mm/year and 0.25 mm/year in those which had been revised (p <
0.001). Polyethylene wear was a strong independent risk factor for osteolysis and aseptic loosening. The percentage of patients with osteolysis increased proportionately with each quintile of wear-rate. There is a high late rate of failure of the Plasmacup. Patients with the combination of this prosthesis and bearing should be closely monitored after ten years.