Advertisement for orthosearch.org.uk
Results 1 - 19 of 19
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 478 - 484
1 Apr 2020
Daniels AM Wyers CE Janzing HMJ Sassen S Loeffen D Kaarsemaker S van Rietbergen B Hannemann PFW Poeze M van den Bergh JP

Aims. Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture. Methods. Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The observers were asked to determine the presence of a scaphoid or other fracture and to classify the scaphoid fracture based on the Herbert classification system. Fleiss kappa statistics were used to calculate the interobserver agreement for the diagnosis of a fracture. Intraclass correlation coefficients (ICCs) were used to assess the agreement for the classification of scaphoid fracture. Results. A total of nine (29%) scaphoid fractures and 12 (39%) other fractures were diagnosed in 20 patients (65%) using HR-pQCT across the four observers. The interobserver agreement was 91% for the identification of a scaphoid fracture (95% confidence interval (CI) 0.76 to 1.00) and 80% for other fractures (95% CI 0.72 to 0.87). The mean ICC for the classification of a scaphoid fracture in the seven patients diagnosed with scaphoid fracture by all four observers was 73% (95% CI 0.42 to 0.94). Conclusion. We conclude that the diagnosis of scaphoid and other fractures is reliable when using HR-pQCT in patients with a clinically-suspected fracture. Cite this article: Bone Joint J 2020;102-B(4):478–484


Aims. The aim of this study was to compare patient-reported outcome measures (PROMs) and the Single Assessment Numerical Evaluation (SANE) score in patients treated with a volar locking plate for a distal radial fracture. Methods. This study was a retrospective review of a prospective database of 155 patients who underwent internal fixation with a volar locking plate for a distal radial fracture between August 2014 and April 2017. Data which were collected included postoperative PROMs (Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH) and Patient-Rated Wrist Evaluation (PRWE)), and SANE scores at one month (n = 153), two months (n = 155), three months (n = 144), six months (n = 128), and one year (n = 73) after operation. Patients with incomplete data were excluded from this study. Correlation and agreement between PROMs and SANE scores were evaluated. Subgroup analyses were carried out to identify correlations according to variables such as age, the length of follow-up, and subcategories of the PRWE score. Results. The Pearson correlation coefficient (r) between PROMs and SANE scores was -0.76 (p < 0.001) for DASH and -0.72 (p < 0.001) for PRWE, respectively. Limits of agreement between PROMs and ‘100-SANE’ scores were met for at least 93% of the data points. In subgroup analysis, there were significant negative correlations between PROMs and SANE scores for all age groups and for follow-up of more than six months. The correlation coefficient between PRWE subcategories and SANE score was -0.67 (p < 0.001) for PRWE pain score and -0.69 (p < 0.001) for PRWE function score, respectively. Conclusion. We found a significant correlation between postoperative SANE and PROMs in patients treated with a volar locking plate for a distal radial fracture. The SANE score is thus a reliable indicator of outcome for patients who undergo surgical treatment for a radial fracture. Cite this article: Bone Joint J 2020;102-B(6):744–748


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1257 - 1262
1 Nov 2024
Nowak LL Moktar J Henry P Dejong T McKee MD Schemitsch EH

Aims

We aimed to compare reoperations following distal radial fractures (DRFs) managed with early fixation versus delayed fixation following initial closed reduction (CR).

Methods

We used administrative databases in Ontario, Canada, to identify DRF patients aged 18 years or older from 2003 to 2016. We used procedural and fee codes within 30 days to determine which patients underwent early fixation (≤ seven days) or delayed fixation following CR. We grouped patients in the delayed group by their time to definitive fixation (eight to 14 days, 15 to 21 days, and 22 to 30 days). We used intervention and diagnostic codes to identify reoperations within two years. We used multivariable regression to compare the association between early versus delayed fixation and reoperation for all patients and stratified by age (18 to 60 years and > 60 years).


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 993 - 999
1 Sep 2023
van Delft EAK van Bruggen SGJ van Stralen KJ Bloemers FW Sosef NL Schep NWL Vermeulen J

Aims

There is no level I evidence dealing with the optimal period of immobilization for patients with a displaced distal radial fracture following closed reduction. A shorter period might lead to a better functional outcome due to less stiffness and pain. The aim of this study was to investigate whether this period could be safely reduced from six to four weeks.

Methods

This multicentre randomized controlled trial (RCT) included adult patients with a displaced distal radial fracture, who were randomized to be treated with immobilization in a cast for four or six weeks following closed reduction. The primary outcome measure was the Patient-Rated Wrist Evaluation (PRWE) score after follow-up at one year. Secondary outcomes were the abbreviated version of the Disability of Arm, Shoulder and Hand (QuickDASH) score after one year, the functional outcome at six weeks, 12 weeks, and six months, range of motion (ROM), the level of pain after removal of the cast, and complications.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1142 - 1147
3 Oct 2022
van den Berg C van der Zwaard B Halperin J van der Heijden B

Aims

The aim of this retrospective study was to evaluate the rate of conversion to surgical release after a steroid injection in patients with a trigger finger, and to analyze which patient- and trigger finger-related factors affect the outcome of an injection.

Methods

The medical records of 500 patients (754 fingers) treated for one or more trigger fingers with a steroid injection or with surgical release, between 1 January 2016 and 1 April 2020 with a follow-up of 12 months, were analyzed. Conversion to surgical release was recorded as an unsuccessful treatment after an injection. The effect of patient- and trigger finger-related characteristics on the outcome of an injection was assessed using stepwise manual backward multivariate logistic regression analysis.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1380 - 1385
2 Aug 2021
Kim Y Ryu J Kim JK Al-Dhafer BAA Shin YH

Aims

The aim of this study was to assess arthritis of the basal joint of the thumb quantitatively using bone single-photon emission CT/CT (SPECT/CT) and evaluate its relationship with patients’ pain and function.

Methods

We retrospectively reviewed 30 patients (53 hands) with symptomatic basal joint arthritis of the thumb between April 2019 and March 2020. Visual analogue scale (VAS) scores for pain, grip strength, and pinch power of both hands and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores were recorded for all patients. Basal joint arthritis was classified according to the modified Eaton-Glickel stage using routine radiographs and the CT scans of SPECT/CT, respectively. The maximum standardized uptake value (SUVmax) from SPECT/CT was measured in the four peritrapezial joints and the highest uptake was used for analysis.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1697 - 1702
1 Dec 2020
Schormans PMJ Kooijman MA Ten Bosch JA Poeze M Hannemann PFW

Aims

Fixation of scaphoid nonunion with a volar locking plate and cancellous bone grafting has been shown to be a successful technique in small series. Few mid- or long-term follow-up studies have been reported. The aim of this study was to report the mid-term radiological and functional outcome of plate fixation for scaphoid nonunion.

Methods

Patients with a scaphoid nonunion were prospectively enrolled and treated with open reduction using a volar approach, debridement of the nonunion, and fixation using a locking plate and cancellous bone grafting, from the ipsilateral iliac crest. Follow-up included examination, functional assessment using the patient-rated wrist/hand evaluation (PRWHE), and multiplanar reformation CT scans at three-month intervals until union was confirmed.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 711 - 717
1 Apr 2021
Feitz R van der Oest MJW van der Heijden EPA Slijper HP Selles RW Hovius SER

Aims

Patients with a triangular fibrocartilage complex (TFCC) injury report ulnar-sided wrist pain and impaired function. The surgical procedure of TFCC reinsertion aims to improve function in patients with this injury in whom conservative treatment has failed. The purpose of this study was to investigate the outcomes of open TFCC reinsertion.

Methods

The study involved 274 patients who underwent open repair of the TFCC between December 2013 and December 2018. The patients completed the Patient-Rated Wrist Evaluation (PRWE) questionnaire, and scored pain and function using a visual analogue scale (VAS). Range of motion (ROM) was assessed by experienced hand therapists.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1200 - 1209
14 Sep 2020
Miyamura S Lans J He JJ Murase T Jupiter JB Chen NC

Aims

We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations.

Methods

We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1542 - 1548
2 Nov 2020
Stirling PHC Oliver WM Ling Tan H Brown IDM Oliver CW McQueen MM Molyneux SG Duckworth AD

Aims

The primary aim of this study was to describe patient satisfaction and health-related quality of life (HRQoL) following corrective osteotomy for a symptomatic malunion of the distal radius.

Methods

We retrospectively identified 122 adult patients from a single centre over an eight-year period who had undergone corrective osteotomy for a symptomatic malunion of the distal radius. The primary long-term outcome was the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes included the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, the EQ-5D-5L score, complications, and the Net Promoter Score (NPS). Multivariate regression analysis was used to determine factors associated with the PRWE score.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 874 - 880
1 Jul 2020
Langerhuizen DWG Bergsma M Selles CA Jaarsma RL Goslings JC Schep NWL Doornberg JN

Aims

The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging.

Methods

A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 749 - 754
1 Jun 2020
Jung H Park MJ Won Y Lee GY Kim S Lee JS

Aims

The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear.

Methods

Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1508 - 1514
1 Nov 2017
Park JH Jang WY Kwak DH Park JW

Aims

Positive ulnar variance is an established risk factor for idiopathic ulnar impaction syndrome (UIS). However, not all patients with positive ulnar variance develop symptomatic UIS and other factors, including the morphology of the lunate, may be involved. The aim of this study was to clarify the relationship between lunate morphology and idiopathic UIS.

Patients and Methods

A cohort of 95 patients with idiopathic UIS (UIS group) was compared with 95 asymptomatic controls with positive ulnar variance. The shape of the lunate was measured using the capitate-triquetrum distance (CTD), ulnar coverage ratio (UCR), radiolunate distance and radiolunate angle. The association of radiographic parameters and lunate types with the development of UIS was investigated in univariable and multivariable analyses. Receiver operating characteristic curves were used to estimate a cutoff for any statistically significant variables.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 369 - 375
1 Mar 2017
Ross M Wiemann M Peters SE Benson R Couzens GB

Aims

The aims of this study were: firstly, to investigate the influence of the thickness of cartilage at the sigmoid notch on the inclination of the distal radioulnar joint (DRUJ), and secondly, to compare the sensitivity and specificity of MRI with plain radiographs for the assessment of the inclination of the articular surface of the DRUJ in the coronal plane.

Patients and Methods

Contemporaneous MRI images and radiographs of 100 wrists from 98 asymptomatic patients (mean age 43 years, (16 to 67); 52 male, 53%) with no history of a fracture involving the wrist or surgery to the wrist, were reviewed. The thickness of the cartilage at the sigmoid notch, inclination of the DRUJ and Tolat Type of each DRUJ were determined.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 94 - 99
1 Jan 2017
Kim JM Zimmerman RM Jones CM Muhit AA Higgins JP Means Jr KR

Aims

Our purpose was to determine the quality of current randomised controlled trials (RCTs) in hand surgery using standardised metrics.

Materials and Methods

Based on five-year mean impact factors, we selected the six journals that routinely publish studies of upper extremity surgery. Using a journal-specific search query, 62 RCTs met our inclusion criteria. Then three blinded reviewers used the Jadad and revised Coleman Methodology Score (RCMS) to assess the quality of the manuscripts.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1069 - 1073
1 Aug 2016
Stirling E Jeffery J Johnson N Dias J

Aims

The degree of displacement of a fracture of the distal radius is an important factor which can be assessed using simple radiographic measurements. Our aim was to investigate the reliability and reproducibility of these measurements and to determine if they should be used clinically.

Patients and Methods

A 10% sample was randomly generated from 3670 consecutive adult patients who had presented to University Hospitals of Leicester NHS Trust between 2007 and 2010 with a fracture of the distal radius. Radiographs of the 367 patients were assessed by two independent reviewers. Four measurements of displacement of the fracture were recorded and the inter-observer correlation assessed using the intra-class correlation coefficient.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 818 - 823
1 Jun 2015
Plant CE Hickson C Hedley H Parsons NR Costa ML

We conducted an observational radiographic study to determine the inter- and intra-observer reliability of the AO classification of fractures of the distal radius. Plain posteroanterior and lateral radiographs of 456 patients with an acute fracture of the distal radius were classified by a consultant orthopaedic hand specialist and two specialist trainees, and the k coefficient for the inter- and intra-observer reliability of the type, group and subgroup classification was calculated.

Only the type of fracture (A, B or C) was found to provide substantial intra-observer reliability (k type 0.65). The inclusion of ‘group’ and ‘subgroup’ into the classification reduced the inter-observer reliability to fair (kgroup 0.29, ksubgroup = 0.28) and the intra-observer reliability to moderate (kgroup 0.53, ksubgroup 0.49). Disagreement was found to arise between specific subgroups, which may be amenable to clarification.

Cite this article: Bone Joint J 2015; 97-B:818–23.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1070 - 1076
1 Aug 2014
Hannemann PFW van Wezenbeek MR Kolkman KA Twiss ELL Berghmans CHJ Dirven PAMGM Brink PRG Poeze M

We hypothesised that the use of pulsed electromagnetic field (PEMF) bone growth stimulation in acute scaphoid fractures would significantly shorten the time to union and reduce the number of nonunions in a randomised, double-blind, placebo-controlled multicentre trial. A total of 102 patients (78 male, 24 female; mean age 35 years (18 to 77)) from five different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly allocated to PEMF (n = 51) or placebo (n = 51) and assessed with regard to functional and radiological outcomes (multiplanar reconstructed CT scans) at 6, 9, 12, 24 and 52 weeks. The overall time to clinical and radiological healing did not differ significantly between the active PEMF group and the placebo group. We concluded that the addition of PEMF bone growth stimulation to the conservative treatment of acute scaphoid fractures does not accelerate bone healing.

Cite this article: Bone Joint J 2014; 96-B:1070–6.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1370 - 1376
1 Oct 2015
Jordan RW Saithna A

This article is a systematic review of the published literature about the biomechanics, functional outcome and complications of intramedullary nailing of fractures of the distal radius.

We searched the Medline and EMBASE databases and included all studies which reported the outcome of intramedullary (IM) nailing of fractures of the distal radius. Data about functional outcome, range of movement (ROM), strength and complications, were extracted. The studies included were appraised independently by both authors using a validated quality assessment scale for non-controlled studies and the CONSORT statement for randomised controlled trials (RCTs).

The search strategy revealed 785 studies, of which 16 were included for full paper review. These included three biomechanical studies, eight case series and five randomised controlled trials (RCTs).

The biomechanical studies concluded that IM nails were at least as strong as locking plates. The clinical studies reported that IM nailing gave a comparable ROM, functional outcome and grip strength to other fixation techniques.

However, the mean complication rate of intramedullary nailing was 17.6% (0% to 50%). This is higher than the rates reported in contemporary studies for volar plating. It raises concerns about the role of intramedullary nailing, particularly when comparative studies have failed to show that it has any major advantage over other techniques. Further adequately powered RCTs comparing the technique to both volar plating and percutaneous wire fixation are needed.

Cite this article: Bone Joint J 2015;97-B:1370–6.