Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1595 - 1602
1 Dec 2013
Modi CS Beazley J Zywiel MG Lawrence TM Veillette CJH

The aim of this review is to address controversies in the management of dislocations of the acromioclavicular joint. Current evidence suggests that operative rather than non-operative treatment of Rockwood grade III dislocations results in better cosmetic and radiological results, similar functional outcomes and longer time off work. Early surgery results in better functional and radiological outcomes with a reduced risk of infection and loss of reduction compared with delayed surgery. Surgical options include acromioclavicular fixation, coracoclavicular fixation and coracoclavicular ligament reconstruction. Although non-controlled studies report promising results for arthroscopic coracoclavicular fixation, there are no comparative studies with open techniques to draw conclusions about the best surgical approach. Non-rigid coracoclavicular fixation with tendon graft or synthetic materials, or rigid acromioclavicular fixation with a hook plate, is preferable to fixation with coracoclavicular screws owing to significant risks of loosening and breakage. The evidence, although limited, also suggests that anatomical ligament reconstruction with autograft or certain synthetic grafts may have better outcomes than non-anatomical transfer of the coracoacromial ligament. It has been suggested that this is due to better restoration horizontal and vertical stability of the joint. Despite the large number of recently published studies, there remains a lack of high-quality evidence, making it difficult to draw firm conclusions regarding these controversial issues. Cite this article: Bone Joint J 2013;95-B:1595–1602


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1657 - 1661
1 Dec 2015
Taranu R Rushton PRP Serrano-Pedraza I Holder L Wallace WA Candal-Couto JJ

Dislocation of the acromioclavicular joint is a relatively common injury and a number of surgical interventions have been described for its treatment. Recently, a synthetic ligament device has become available and been successfully used, however, like other non-native solutions, a compromise must be reached when choosing non-anatomical locations for their placement. This cadaveric study aimed to assess the effect of different clavicular anchorage points for the Lockdown device on the reduction of acromioclavicular joint dislocations, and suggest an optimal location. We also assessed whether further stability is provided using a coracoacromial ligament transfer (a modified Neviaser technique). The acromioclavicular joint was exposed on seven fresh-frozen cadaveric shoulders. The joint was reconstructed using the Lockdown implant using four different clavicular anchorage points and reduction was measured. The coracoacromial ligament was then transferred to the lateral end of the clavicle, and the joint re-assessed. If the Lockdown ligament was secured at the level of the conoid tubercle, the acromioclavicular joint could be reduced anatomically in all cases. If placed medial or 2 cm lateral, the joint was irreducible. If the Lockdown was placed 1 cm lateral to the conoid tubercle, the joint could be reduced with difficulty in four cases. Correct placement of the Lockdown device is crucial to allow anatomical joint reduction. Even when the Lockdown was placed over the conoid tubercle, anterior clavicle displacement remained but this could be controlled using a coracoacromial ligament transfer. Cite this article: Bone Joint J 2015;97-B:1657–61


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 512 - 518
1 Apr 2016
Spencer HT Hsu L Sodl J Arianjam A Yian EH

Aims. To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries. . Patients and Methods. We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (. sd. ) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis. . Results. Radiographic failure occurred in 33/154 cases (21.4%), with the lowest rate in Technique 4 (2/42 4.8%, p = 0.001). Half the failures occurred by six weeks, and the Kaplan-Meier survivorship at 24 months was 94.4% (95% confidence interval (CI) 79.6 to 98.6) for Technique 4 and 69.9% (95% CI 59.4 to 78.3) for the other techniques when combined. In multivariable survival analysis, Technique 4 had better survival than other techniques (Hazard Ratio 0.162, 95% CI 0.039 to 0.068, p = 0.013). Among 155 patients with a minimum of six months post-operative insurance coverage, re-operation occurred in 9.7% (15 patients). However, in multivariable logistic regression, Technique 4 did not reach a statistically significant lower risk for re-operation (odds ratio 0.254, 95% CI 0.05 to 1.3, p = 0.11). Conclusion. In this retrospective series, anatomical CC ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. . Take home message: Anatomical coracoclavicular ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. Cite this article: Bone Joint J 2016;98-B:512–18


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 83 - 88
1 Jan 2015
Kocsis G McCulloch TA Thyagarajan D Wallace WA

The LockDown device (previously called Surgilig) is a braided polyester mesh which is mostly used to reconstruct the dislocated acromioclavicular joint. More than 11 000 have been implanted worldwide. Little is known about the tissue reaction to the device nor to its wear products when implanted in an extra-articular site in humans. This is of importance as an adverse immunological reaction could result in osteolysis or damage to the local tissues, thereby affecting the longevity of the implant. We analysed the histology of five LockDown implants retrieved from five patients over the last seven years by one of the senior authors. Routine analysis was carried out in all five cases and immunohistochemistry in one. The LockDown device acts as a scaffold for connective tissue which forms an investing fibrous pseudoligament. The immunological response at the histological level seems favourable with a limited histiocytic and giant cell response to micron-sized wear particles. The connective tissue envelope around the implant is less organised than a native ligament. Cite this article: Bone Joint J 2015;97-B:83–8


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 360 - 364
1 Mar 2020
Jenkins PJ Stirling PHC Ireland J Elias-Jones C Brooksbank AJ

Aims. The aim of this study was to examine the recent trend in delivery of arthroscopic subacromial decompression (ASD) in Scotland and to determine if this varies by geographical location. Methods. Scottish Morbidity Records were reviewed retrospectively between March 2014 and April 2018 to identify records for every admission to each NHS hospital. The Office of Population Censuses and Surveys (OPCS-4) surgical codes were used to identify patients undergoing primary ASD. Patients who underwent acromioclavicular joint excision (ACJE) and rotator cuff repair (RCR) were identified and grouped separately. Procedure rates were age and sex standardized against the European standard population. Results. During the study period the number of ASDs fell by 649 cases (29%) from 2,217 in the first year to 1,568 in the final year. The standardized annual procedure rate fell from 41.6 (95% confidence interval (CI) 39.9 to 43.4) to 28.9 (95% CI 27.4 to 30.3) per 100,000. The greatest reduction occurred between 2017 and 2018. The number of ACJEs rose from 41 to 188 (a 3.59-fold increase). The number of RCRs fell from 655 to 560 (-15%). In the year 2017 to 2018 there were four (28.6%) Scottish NHS board areas where the ASD rate was greater than 3 standard deviations (SDs) from the national average, and two (14.3%) NHS boards where the rate was less than 3 SDs from the national average. Conclusion. There has been a clear decline in the rate of ASD in Scotland since 2014. Over the same period there has been an increase in the rate of ACJE. The greatest decline occurred between 2017 and 2018, corresponding to the publication of epidemiological studies demonstrating a rise in ASD, and awareness of studies which questioned the benefit of ASD. This paper demonstrates the potential impact of information from epidemiological studies, referral guidelines, and well-designed large multicentre randomized controlled trials on clinical practice. Cite this article: Bone Joint J 2020;102-B(3):360–364


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 534 - 542
1 May 2023
Makaram NS Khan LAK Jenkins PJ Robinson CM

Aims

The outcomes following nonoperative management of minimally displaced greater tuberosity (GT) fractures, and the factors which influence patient experience, remain poorly defined. We assessed the early patient-derived outcomes following these injuries and examined the effect of a range of demographic- and injury-related variables on these outcomes.

Methods

In total, 101 patients (53 female, 48 male) with a mean age of 50.9 years (19 to 76) with minimally displaced GT fractures were recruited to a prospective observational cohort study. During the first year after injury, patients underwent experiential assessment using the Disabilities of the Arm, Shoulder and Hand (DASH) score and assessment of associated injuries using MRI performed within two weeks of injury. The primary outcome was the one-year DASH score. Multivariate analysis was used to assess the effect of patient demographic factors, complications, and associated injuries, on outcome.


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 401 - 407
1 Mar 2022
Kriechling P Zaleski M Loucas R Loucas M Fleischmann M Wieser K

Aims

The aim of this study was to report the incidence of implant-related complications, further operations, and their influence on the outcome in a series of patients who underwent primary reverse total shoulder arthroplasty (RTSA).

Methods

The prospectively collected clinical and radiological data of 797 patients who underwent 854 primary RTSAs between January 2005 and August 2018 were analyzed. The hypothesis was that the presence of complications would adversely affect the outcome. Further procedures were defined as all necessary operations, including reoperations without change of components, and partial or total revisions. The clinical outcome was evaluated using the absolute and relative Constant Scores (aCS, rCS), the Subjective Shoulder Value (SSV) scores, range of motion, and pain.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 963 - 966
1 Jul 2015
Evans JP Guyver PM Smith CD

Frozen shoulder is a recognised complication following simple arthroscopic shoulder procedures, but its exact incidence has not been reported. Our aim was to analyse a single-surgeon series of patients undergoing arthroscopic subacromial decompression (ASD; group 1) or ASD in combination with arthroscopic acromioclavicular joint (ACJ) excision (group 2), to establish the incidence of frozen shoulder post-operatively. Our secondary aim was to identify associated risk factors and to compare this cohort with a group of patients with primary frozen shoulder.

We undertook a retrospective analysis of 200 consecutive procedures performed between August 2011 and November 2013. Group 1 included 96 procedures and group 2 104 procedures. Frozen shoulder was diagnosed post-operatively using the British Elbow and Shoulder Society criteria. A comparative group from the same institution involved 136 patients undergoing arthroscopic capsular release for primary idiopathic frozen shoulder.

The incidence of frozen shoulder was 5.21% in group 1 and 5.71% in group 2. Age between 46 and 60 years (p = 0.002) and a previous idiopathic contralateral frozen shoulder (p < 0.001) were statistically significant risk factors for the development of secondary frozen shoulder. Comparison of baseline characteristics against the comparator groups showed no statistically significant differences for age, gender, diabetes and previous contralateral frozen shoulder.

These results suggest that the risk of frozen shoulder following simple arthroscopic procedures is just over 5%, with no increased risk if the ACJ is also excised. Patients aged between 46 and 60 years and a previous history of frozen shoulder increase the relative risk of secondary frozen shoulder by 7.8 (95% confidence interval (CI) 2.1 to 28.3)and 18.5 (95% CI 7.4 to 46.3) respectively.

Cite this article: Bone Joint J 2015; 97-B:963–6.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 75 - 81
1 Jan 2014
Kukkonen J Joukainen A Lehtinen J Mattila KT Tuominen EKJ Kauko T Äärimaa V

We have compared three different methods of treating symptomatic non-traumatic tears of the supraspinatus tendon in patients above 55 years of age. A total of 180 shoulders (173 patients) with supraspinatus tendon tears were randomly allocated into one of three groups (each of 60 shoulders); physiotherapy (group 1), acromioplasty and physiotherapy (group 2) and rotator cuff repair, acromioplasty and physiotherapy (group 3). The Constant score was assessed and followed up by an independent observer pre-operatively and at three, six and twelve months after the intervention.

Of these, 167 shoulders were available for assessment at one year (follow-up rate of 92.8%). There were 55 shoulders in group 1 (24 in males and 31 in females, mean age 65 years (55 to 79)), 57 in group 2 (29 male and 28 female, mean age 65 years (55 to 79)) and 55 shoulders in group 3 (26 male and 29 female, mean age 65 years (55 to 81)). There were no between-group differences in the Constant score at final follow-up: 74.1 (sd 14.2), 77.2 (sd 13.0) and 77.9 (sd 12.1) in groups 1, 2 and 3, respectively (p = 0.34). The mean change in the Constant score was 17.0, 17.5, and 19.8, respectively (p = 0.34). These results suggest that at one-year follow-up, operative treatment is no better than conservative treatment with regard to non-traumatic supraspinatus tears, and that conservative treatment should be considered as the primary method of treatment for this condition.

Cite this article: Bone Joint J 2014;96-B:75–81.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1525 - 1529
1 Nov 2014
Thangarajah T Alexander S Bayley I Lambert SM

We report our experience with glenohumeral arthrodesis as a salvage procedure for epilepsy-related recurrent shoulder instability. A total of six patients with epilepsy underwent shoulder fusion for recurrent instability and were followed up for a mean of 39 months (12 to 79). The mean age at the time of surgery was 31 years (22 to 38). Arthrodesis was performed after a mean of four previous stabilisation attempts (0 to 11) in all but one patient in whom the procedure was used as a primary treatment. All patients achieved bony union, with a mean time to fusion of 2.8 months (2 to 7). There were no cases of re-dislocation. One revision was undertaken for loosening of the metalwork, and then healed satisfactorily. An increase was noted in the mean subjective shoulder value, which improved from 37 (5 to 50) pre-operatively to 42 (20 to 70) post-operatively although it decreased in two patients. The mean Oxford shoulder instability score improved from 13 pre-operatively (7 to 21) to 24 post-operatively (13 to 36). In our series, glenohumeral arthrodesis eliminated recurrent instability and improved functional outcome. Fusion surgery should therefore be considered in this patient population. However, since the majority of patients are young and active, they should be comprehensively counselled pre-operatively given the functional deficit that results from the procedure.

Cite this article: Bone Joint J 2014;96-B:1525–9.